• Title/Summary/Keyword: Platelet transfusion

Search Result 44, Processing Time 0.02 seconds

Association between Transfusion-Related Iron Overload and Liver Fibrosis in Survivors of Pediatric Leukemia: A Cross-Sectional Study

  • Mahsa Sobhani;Naser Honar;Mohammadreza Fattahi;Sezaneh Haghpanah;Nader Shakibazad;Mohammadreza Bordbar
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.27 no.4
    • /
    • pp.215-223
    • /
    • 2024
  • Purpose: Patients who receive frequent blood transfusions are at an elevated risk of developing hepatic fibrosis due to iron overload in the liver. In this study, we evaluated the effectiveness of transient elastography (TE) (FibroScan®) for assessing liver fibrosis in patients with pediatric cancer. Methods: We enrolled 106 consecutive cases of acute leukemia in individuals under 21 years of age. The participants were followed for 2 years. Based on their serum ferritin (SF) levels, the patients were divided into two groups: group 1 (SF≥300 ng/mL) and group 2 (SF<300 ng/mL). A liver FibroScan® was performed, and a p-value of less than 0.05 was considered statistically significant. Results: Among the various parameters in the liver function test (LFT), alkaline phosphatase was significantly higher in a subgroup of patients aged 5-8 years in group 2 compared to those in group 1. The indices of liver fibrosis determined by TE, including the FibroScan score, controlled attenuation parameter score, steatosis percentage, and meta-analysis of histological data in viral hepatitis score, as well as indirect serum markers of liver fibrosis such as the aminotransferase (AST)/alanine aminotransferase (ALT) ratio, Fibrosis 4 score, and AST to platelet ratio index, did not differ significantly between the two groups. The association between the TE results and LFT parameters was only significant for ALT. Conclusion: Transfusion-associated iron overload does not have a significant correlation with severe liver fibrosis. FibroScan® is not a sensitive tool for detecting early stages of fibrosis in survivors of pediatric leukemia.

Effects of Autotransfusion Using Cell Saver in Cardiovascular Surgery (심혈관수술에서 cell saver를 이용한 자가수혈)

  • 구자홍
    • Journal of Chest Surgery
    • /
    • v.26 no.4
    • /
    • pp.255-259
    • /
    • 1993
  • The efficacy of the autotransfusion system is a reducing the need of intraoperative and postoperative transfusion in cardiovascular surgery. Between January 1990 and December 1991, we experienced 23 cases of autotransfusion using Haemonetic Cell Saver in cardiovascular surgery [Experimental group]. Another 13 cases which were taken similiar operations without Cell Saver during same period [Control group]. The amounts of blood transfused are 4.23 1.84 units in Control group, 2.82 1.84 units in Experimental group. Postoperatively, both groups showed decreased platelet counts, mild prolongation of prothrombin and partial thromboplastin time compred to preoperative value [P<0.001], but there were no significant differences between two group [P=NS]. Plasma hemoglobin was markedly increased in Experimental group compared with Control group [p<0.05]. In Experimental group, amount of average processed blood by Cell Saver was 700ml of which composition was hemoglobin 17mg/dl, hematocrit 50.0%, RBC 5,590,000/ml, WBC 7500/ml, and platelet 40,000/ml. The culture of the processed blood revealed no growth of the organisms. Conclusively, Cell Saver autotransfusion system is a simple, safe, and cost effective method especially in the cases associated with massive bleeding. However, it requires familiarity with system, gentle manipulation of suction tip, and careful selection of candidates to obtain maximal benefits .

  • PDF

Plateletpheresis: the Process, Devices, and Indicators of Product Quality (혈소판성분채집술: 채집과정, 장비, 성분채집혈소판 질의 지표들)

  • Jang, Chul-Soo;Kim, Sung-In;Kim, Hyun-Kyung;Kweon, Chang-Oh;Kim, Byung-Won;Kim, Dong-Chan;Kim, Yoon Suk;Rhee, Ki-Jong;Ryu, Jae-Ki
    • Journal of Life Science
    • /
    • v.24 no.9
    • /
    • pp.1030-1038
    • /
    • 2014
  • Platelet products are used to treat hemorrhagic or platelet dysfunction diseases. Plateletpheresis involves collecting the platelet components of blood using an apheresis blood-collection system. Various indicators are available for evaluating the qualities of the apheresis platelets. The productivity of platelet collection is evaluated through both the collection efficiency and collection rates. Platelet storage quality can be evaluated in vitro using several indicators, including visual appearance, metabolic activities, volume, platelet count, white blood cell count, microparticles, and various platelet activation markers. Platelet activation markers have been used as indicators of storage quality in various studies. Post-transfusion platelet quality can be evaluated based on the corrected count increment and the percentage of platelet recovery. Although various studies have investigated the aspects of plateletpheresis, no article has systemically presented assessments of the platelet products obtained from different plateletpheresis devices. The present study provides a review of plateletpheresis, including the specifics of the process, the types of devices employed, the platelet quality, the overall efficacy, and the evaluation indicator qualities. Furthermore, the differences in functionality among the different apheresis devices are discussed. Although adverse reactions to the citrate anti-coagulant have been reported, apheresis processing may provide a safer option for donors who are at a high risk for presyncopal or syncopal reactions related to whole blood collection.

The benefit of platelet-rich plasma injection over institution-based physical therapy program in adhesive capsulitis patients with diabetes mellitus: prospective observational cohort study

  • Barman, Apurba;Mukherjee, Somnath;Sinha, Mithilesh K;Sahoo, Jagannatha;Viswanath, Amrutha
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.4
    • /
    • pp.215-223
    • /
    • 2021
  • Background: The objective of this study was to compare the efficacy of platelet-rich plasma (PRP) injection with an institution-based physical therapy (PT) program for adhesive capsulitis (AC) of the shoulder in patients with diabetes mellitus (DM). Methods: A total of seventy diabetic patients with AC of the shoulder for <6 months were assigned to two groups: PRP group and PT group. In the PRP group, 35 patients were administered a single shot of PRP (4 mL) into the glenohumeral joint. In the PT group, 35 patients were given institution-based PT that included 10 30-minute sessions of planned PT over a 2-week period. After the interventions, all patients were prospectively followed for 12 weeks. Intensity of shoulder pain, function, and range of motion were assessed at baseline and then at 3, 6, and 12 weeks. Results: Thirty-three patients in the PRP group and 32 in the PT group completed the 12-week study. At 12 weeks, patients who received PRP injections showed greater improvement in shoulder pain (p<0.001) than those recruited to the PT group. In the range of motion and shoulder function activities, patients in the PRP group showed significant improvement compared with the institution-based PT group (p<0.001). No significant complications were reported from any groups. Conclusions: In a diabetic population, PRP injections significantly improved shoulder pain and function compared with an institution-based PT program for shoulder AC. Additionally, it is a safe and well-tolerated method for AC management for diabetic patients.

Statistical Analysis of Quality Control Data of Blood Components (혈액성분제제 품질관리 자료의 통계학적인 비교)

  • Kim, Chongahm;Seo, Dong Hee;Kwon, So Yong;Oh, Yuong Chul;Lim, Chae Seung;Jang, Choong Hoon;Kim, Soonduck
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.1
    • /
    • pp.19-26
    • /
    • 2004
  • According to increase of domestic blood components use, the quality control of blood components is necessary to support good products. The purpose of this study is used to provide the producing index of the good product as compared with the accuracy and validity for the distribution of the quality control data. The value of mean, standard deviation, 95% confidence interval and degree of normal distribution of data were calculated by univariate procedure, the value of monthly mean of each blood centers per items were compared by Analysis of Variance(ANOVA) test for the degree of distribution. When there was difference among the mean values, the Duncan's multiple range test was done to confirm the difference. Finally, methods for accessing accuracy and validity of the quality data was done by the Contingency table test. The quality data of five blood centers was showed to the normal distribution and it was in a acceptable range. For each blood centers, the monthly means of Hematocrit(Hct), Platelet(PLT) and pH were not significantly different except Hct of C center, PLT of B, D center and pH of A center. The quality data per items was graded according to quality to six level. As a result of the comparative analysis, the monthly means of Hct of C and E center was significantly different higher than that of D, B and A center. The monthly means of PLT of A center and pH of C center was significantly different higher than that of the others. In the accuracy and validity of the quality control data, C center for Hct, A center for PLT and C center for pH were better than the other. The C blood center was most satisfiable and stable in the quality control for blood component. If the quality control method used in C blood center is adopted in other blood centers, the prepared level of the blood component of the center will be improved partly.

  • PDF

Dental Management in a Patient with Glanzmann's Thrombasthenia : A Case Report (글란즈만 혈소판무력증 환자의 치과적 관리)

  • Han, Miran;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.3
    • /
    • pp.352-358
    • /
    • 2020
  • Glanzmann's thrombasthenia (GT) is a rare, autosomal recessive inherited congenital disorder, characterized by impaired blood coagulation due to platelet dysfunction. It was first reported by the pediatrician Glanzmann in 1918. GT affects both males and females, and it is more common in regions of the Middle East, India, and France, where intermarriage is common. It has an incidence of about 1 in 1,000,000 people. In South Korea, according to the Division of Rare Diseases, Korea Centers for Disease Control and Prevention, around 200 cases have been reported in 2018. Clinical symptoms include petechia, ecchymosis, epistaxis, and gingival bleeding. The spontaneous loss of deciduous teeth can result in excessive bleeding with that blood transfusion should be considered. Preventing hemorrhages and hemostasis are most important factors in dental treatment. Local bleeding can be controlled by compression, but platelet transfusion can be required by prolonged bleeding. Pediatric dentists can minimize the gingival bleeding by control of the oral hygiene to prevent gingivitis and dental caries. The importance of oral hygiene and periodic recall check-up should be emphasized. During dental treatment, the examination and the treatment plan of patient should be modified to prevention of hemorrhages carefully. A 6-year-old girl with GT was referred for the treatment of dental caries, and resin restoration was performed under nitrous oxide inhalation sedation. After treatment, compression was required for the bleeding control.

Clinical Significance of Antibodies Against Platelet HLA Class I in Children with Idiopathic Thrombocytopenic Purpura (소아 특발성 혈소판 감소증에서 항-HLA Class I항체의 임상적 의미)

  • Lee, Hong Jun;Yeom, Jung-Sook;Park, Ji Sook;Park, Eun Sil;Seo, Ji-Hyun;Lim, Jae Young;Park, Chan-Hoo;Woo, Hyang-Ok;Youn, Hee-Shang
    • The Korean Journal of Blood Transfusion
    • /
    • v.24 no.3
    • /
    • pp.233-240
    • /
    • 2013
  • Background: A previous history of transfusion has been known to be associated with production of anti-HLA class I antibodies. However, platelet glycoproteins are the main target of idiopathic thrombocytopenic purpura (ITP). The mechanism of antibody production is known to differ significantly between glycoproteins and anti-HLA class I. The aim of this study was to evaluate the clinical significance of anti-HLA class I antibodies in childhood ITP. Methods: Enrollment for the normal control group targeted 48 people who visited Gyeongsang National University Hospital from 1990 to 2010, and 48 young children with ITP. Anti-glycoproteins and anti-HLA class I antibodies were tested using the Modified Antigen Capture Enzyme-linked immunosorbent assay (MACE) kit. Results: The positive rate of anti-HLA antibodies was significantly different [36/39 (92.3%) vs 29/46 (63%)] [ITP group vs normal control group] (P=0.002). The mean positive S/C ratio of anti-HLA antibodies was also significantly different (3.55 vs 1.51) [ITP group vs normal control group] (P=0.0000). The positive rate of anti-HLA did not differ significantly between the transfused group and the non-transfused group [12/12 (100%) vs 24/27 (88%)] [transfused ITP vs non-transfused ITP]. The mean positive S/C ratio of anti-HLA antibodies did not differ significantly between the transfused ITP group and the non-transfused ITP group (4.30 vs 3.25) [transfused ITP vs non-transfused ITP]. Consecutive testing showed that positive rate and positive S/C ratio of anti-HLA antibodies did not change significantly between sampling times in both groups [transfused ITP vs non-transfused ITP] (P=1.00 and P=0.15). Conclusion: Anti-HLA class I antibodies may be involved in childhood ITP. Transfusion did not affect the course of childhood ITP.

Thrombocytopenia in Moderate- to High-Risk Sutureless Aortic Valve Replacement

  • Thitivaraporn, Puwadon;Chiramongkol, Sarun;Muntham, Dittapol;Pornpatrtanarak, Nopporn;Kittayarak, Chanapong;Namchaisiri, Jule;Singhatanadgige, Seri;Ongcharit, Pat;Benjacholamas, Vichai
    • Journal of Chest Surgery
    • /
    • v.51 no.3
    • /
    • pp.172-179
    • /
    • 2018
  • Background: This study aimed to compare preliminary data on the outcomes of sutureless aortic valve replacement (SU-AVR) with those of aortic valve replacement (AVR). Methods: We conducted a retrospective study of SU-AVR in moderate- to high-risk patients from 2013 to 2016. Matching was performed at a 1:1 ratio using the Society of Thoracic Surgeons predicted risk of mortality score with sex and age. The primary outcome was 30-day mortality. The secondary outcomes were operative outcomes and complications. Results: A total of 277 patients were studied. Ten patients (50% males; median age, 81.5 years) underwent SU-AVR. Postoperative echocardiography showed impressive outcomes in the SU-AVR group. The 30-day mortality was 10% in both groups. In our study, the patients in the SU-AVR group developed postoperative thrombocytopenia. Platelet counts decreased from $225{\times}10^3/{\mu}L$ preoperatively to 94.5, 54.5, and $50.1{\times}10^3/{\mu}L$ on postoperative days 1, 2, and 3, respectively, showing significant differences compared with the AVR group (p=0.04, p=0.16, and p=0.20, respectively). The median amount of platelet transfusion was higher in the AVR group (12.5 vs. 0 units, p=0.052). Conclusion: There was no difference in the 30-day mortality of moderate-to high-risk patients depending on whether they underwent SU-AVR or AVR. Although SU-AVR is associated with favorable cardiopulmonary bypass and cross-clamp times, it may be associated with postoperative thrombocytopenia.

Analysis of Massive Transfusion Blood Product Use in a Tertiary Care Hospital (일개 3차 의료기관의 대량수혈 혈액 사용 분석)

  • Lim, Young Ae;Jung, Kyoungwon;Lee, John Cook-Jong
    • The Korean Journal of Blood Transfusion
    • /
    • v.29 no.3
    • /
    • pp.253-261
    • /
    • 2018
  • Background: A massive blood transfusion (MT) requires significant efforts by the Blood Bank. This study examined blood product use in MT and emergency O Rh Positive red cells (O RBCs) available directly for emergency patients from the Trauma Center in Ajou University Hospital. Methods: MT was defined as a transfusion of 10 or more RBCs within 24 hours. The extracted data for the total RBCs, fresh frozen plasma (FFP), platelets (PLTs, single donor platelets (SDP) and random platelet concentrates (PC)) issued from Blood Bank between March 2016 and November 2017 from Hospital Information System were reviewed. SDP was considered equivalent to 6 units of PC. Results: A total of 345 MTs, and 6233/53268 (11.7%) RBCs, 4717/19376 (24.3%) FFP, and 4473/94166 (4.8%) PLTs were used in MT (P<0.001). For the RBC products in MT and non-MT transfusions, 28.0% and 34.1% were group A; 27.1% and 26.0% were group B; 37.3% and 29.7% were group O, and 7.5% and 10.2% were group AB (P<0.001). The ratios of RBC:FFP:PLT use were 1:0.76:0.72 in MT and 1:0.31:1.91 in non-MT (P<0.001). A total of 461 O RBCs were used in 36.2% (125/345) of MT cases and the number of O RBCs transfused per patient ranged from 1 to 18. Conclusion: RBCs with the O blood group are most used for MT. Ongoing education of clinicians to minimize the overuse of emergency O RBCs in MT is required. A procedure to have thawed plasma readily available in MT appears to be of importance because FFP was used frequently in MT.

Acute Normovolemic Hemodilution Effects on Perioperative Coagulation in Elderly Patients Undergoing Hepatic Carcinectomy

  • Guo, Jian-Rong;Jin, Xiao-Ju;Yu, Jun;Xu, Feng;Zhang, Yi-Wei;Shen, Hua-Chun;Shao, Yi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.8
    • /
    • pp.4529-4532
    • /
    • 2013
  • Background: Acute normovolemic hemodilution (ANH) has been widely used to prevent the massive blood loss during hepatic carcinoma. The influences of ANH on coagulation function are still controversy, especially in elderly patients. The study observed ANH effects on coagulation function and fibrinolysis in elderly patients undergoing the disease. Materials and Methods: Thirty elderly patients (aged 60-70 yr) with liver cancer (ASA I or II) taken hepatic carcinectomy from February 2007 to February 2008 were randomly divided into ANH group (n=15) and control group (n=15). After tracheal intubation, patients in ANH group and control group were infused with 6% hydroxyethyl starch (130/0.4) and Ringer's solution, respectively. Blood samples were drawn from patients in both groups at five different time points: before anesthesia induction (T1), 30 min after ANH (T2), 1 h after start of operation (T3), immediately after operation (T4), and 24 h after operation (T5). Then coagulation function, soluble fibrin monomer complex (SFMC), prothrombin fragment (F1+2), and platelet membrane glycoprotein (CD62P and activated GP IIb/GP IIIa) were measured. Results: The perioperative blood loss and allogeneic blood transfusion were recorded during the surgery. The perioperative blood loss was not significantly different between two groups (p>0.05), but the volume of allogeneic blood transfusion in ANH group was significantly less than in control group ($350.0{\pm}70.7$) mL vs. ($457.0{\pm}181.3$) mL (p<0.01). Compared with the data of T1, the prothrombin time (PT) and activated partial thromboplastin time (APTT) measured after T3 were significantly longer (p<0.05) in both groups, but within normal range. There were no significant changes of thrombin time (TT) and D-dimer between two groups at different time points (p>0.05). SFMC and F1+2 increased in both groups, but were not statistically significant. PAC-1-positive cells and CD62P expressions in patients of ANH group were significantly lower than those at T1 (p<0.05) and T2-T5 (p>0.05). Conclusions: ANH has no obvious impact on fibrinolysis and coagulation function in elderly patients undergoing resection of liver cancer. The study suggested that ANH is safe to use in elderly patients and it could reduce allogeneic blood transfusion.