Fine blanking is a process of press shearing which makes it possible to produce the thick sheet metal of the finished surface and the close dimensional accuracy over the whole material thickness in the single blanking operation. In this paper, a plate holder of automotive seat recliner is manufactured by FCF(Flow Control Forming) method using the conventional mechanical press instead of the fine blanking press. Main processes for manufacturing of the plate holder by FCF method are embossing, half blanking and trimming processes. Optimal clearance, stripper force and counter force to increase the dimensional accuracy of the plate holder have been investigated by FE-analysis. As a result of FE-analysis, the clearance for both embossing and half blanking processes was -2%t and the forces of stripper and counter were 25ton and 15ton, respectively. After manufacturing the plate holder by FCF method, the measured dimensional characteristics have been compared with the required specifications as the final product. Although the dimensional accuracy of the plate holder manufactured by FCF method was a little inferior to that by fine blanking process, it was satisfactory in a general sense.
Burr generated on plate holder should be removed through additional process, because it has an influence on the function of automotive seat recliner. The process layout to perform simultaneously embossing and half blanking of plate holder has been developed in this study in order to minimize the influence of burr formation. The optimal process condition to satisfy the required dimensional accuracy of plate holder has been determined using Taguchi method and finite element analysis. It has been shown from experimental results that the proposed method is decidedly superior to the previous FCF method from the aspect of sheared surface, roll-over, flatness and burr height.
목적 : 최근의 방사선치료는 정상조직의 장애는 최대한 줄이고 종양조직 선량을 높여 치료효과를 극대화 하기위하여 3차원적으로 발전되어왔으며, 이에 따른 환자 체위고정을 위한 고정기구와 보조기구의 개발이 필수적으로 요구되고 있다. 본원에서는 MR head holder, 개방형 head holder, Plan CT couch plate를 자체 제작하여 그 유용성을 평가하고 분석하였으며, 임상에 적용한 결과를 보고하고자 한다. 대상 및 방법 : MR head holder를 제작하여 진단 MR영상과 치료계획용 MR영상을 CT영상과 fusion하여 두 영상의 일치성과 정확성을 분석하였고, 개방형 head holder를 제작하여 피부선량과 선량감약 정도를 알아보았으며, 6 mm 아크릴판에 스티로폼을 부착하는 CT couch plate를 제작하여 hard plate와 artifact 정도를 비교하였다. 결과 : Head holder를 사용하지 않은 fusion영상보다 2 mm이내의 오차로 정확한 fusion을 할 수 있었고, 개방형 head holder를 사용함에 따라 피부선량을 최대 2배 이상 줄일 수 있었고, $20\%$이상 선량이 감약되는 것을 최소화할 수 있었다. Plan CT couch plate를 사용했을 때는 2단 연결, 부착 식으로 제작하여 사용이 간편하고 artifact를 현저하게 줄일 수 있었다. 결론 : MR 영상에서도 기준 좌표점을 확인할 수 있어 정확한 MR / CT fusion을 시행할 수 있었고, 향후 PET, 초음파 영상의 fusion도 연구되어야 할 것으로 사료되며, 이에 따른 고정기구의 개발도 필수적이라 할 수 있겠다. 개방형 head holder를 사용함으로써 피부선량과 선량 감약을 감소시킬 수 있었다. 이러한 치료보조기구를 자체 제작하여 고가의 외국상품을 대체할 수 있어 비용은 절감할 수 있었지만 견고성에서는 떨어지므로 가볍고 선량 감약이 적으며 강도가 강한 특수 재질의 치료보조기구가 개발되어야 할 것으로 사료된다.
The load characteristics of a piston pump holder due to the squeeze effect are influenced by the surface shape and gap thickness of the holder (cradle). Therefore, the pressure distribution and the load capacity of the piston pump holder due to the squeeze effect are studied by using the CFD software and the surface shape and gap thickness of the piston pump holder are considered. In order to verify the accuracy of numerical results, the load capacities of a circular plate holder are numerically studied, and the accuracy of numerical results is verified by comparing with the theoretical results. Also, the pressure distribution and load capacity of the rectangular plate holder of a piston pump are obtained by using the CFD software. The results show that the load capacity of the square plate holder with grooves is slightly higher at a low gap thickness, but the effects of the number and arrangement of grooves on the load capacity of the holder are weak. We conclude that the load capacity and the maximum pressure are slightly affected due to the existence of grooves on the holder surface, and the fluid storing effect of the holder surface grooves during the operation is likely to prevent the dry-sticking phenomenon.
During the last decade, possibility of flaw occurrences has been rapidly increased world-widely as the increase of operating times of petro-chemical facilities. For instance, from a recent in-service inspection, three different sized surface cracks were detected in welding parts of a spherical oxygen holder in Korea. While API579 code provides corresponding engineering assessment procedures to determine crack driving forces, in the present work, numerical analyses are carried out for the cracked oxygen holder to investigate effects of complex geometry, analysis model and residual stress. With regard to the detailed finite element analysis, stress intensity factors are determined from both the full three-dimensional model and equivalent plate model. Also, as an alternative, stress intensity factors are calculated for equivalent plate model by employing the noted influence stress function technique. Finally, parametric structural integrity evaluation of the cracked oxygen holder is conducted in use of failure assessment diagram method, J/T method and DPFAD method. Effects of the geometry and so forth are examined and key findings from the simulations are fully discussed, which enables to determine practical safety margins of spherical components containing a defect.
지진 및 예기치 못한 외부하중에 의하여 손상된 구조물의 경우, 2차적인 국부손상 및 이로 인한 붕괴가 발생할 수 있어 발파해체공법에 의한 철거가 우선시 고려되고 있다. 특히 철재로 이루어진 교량 및 구조물의 경우 성형폭약을 이용한 발파해체기법이 적용되어 오고 있다. 최근에는 구리판을 드로잉 가공한 성형폭약용기에 상용폭약을 장전하여 두꺼운 철판을 절단하는 발파공법이 제안되었다. 본 연구에서는 LS-DYNA 동해석소프트웨어를 이용하여 드로잉 가공 성형폭약용기와 상용폭약을 적용한 25mm 두께의 철판 절단실험발파를 모사하고 절단형상 및 깊이를 비교분석하여 적용구성모델의 입력변수를 결정하였다. 해석모델을 이용하여 폭약의 종류, 구리 라이너의 두께, 이격거리의 변화에 따른 철판 내 관통깊이 및 관통 폭을 분석하였다.
목적 : 선형가속기를 이용한 방사선 치료시 치료부위의 확인을 위한 하나의 방법으로 port film이 사용되고 있다 서울대학병원에서는 port film 촬영 시 기계적 변수를 port film상에 나타내기 위하여 방향성 표시기(orientation marker)를 갖는 fiduciary plate를 개발하였다. 대상 및 방법 : Fiduciary plate의 제작에는 아크릴 plate와 cerrobend, 수은이 사용되었다. 아크릴 plate의 크기는 $1\;cm{\times}25\;cm{\times}25\;cm$로 그 내부에 두 개의 방향성 표시기가 내재되었고, 선형가속기의 blocking tray slot에 삽입이 가능하도록 제작되었다. Plate 내부에는 2 cm 간격으로 2 mm 두께의 수평과 수직으로 만들어진 cerrobend line이 위치해 있고, 방향성 표시기 내부에는 수은으로 채워져 있다. 결과 : 아크릴 plate의 cerrobend line은 simulation films과 port films간의 치료 영역의 비교를 용이하게 한다. 수은을 이용하여 만들어진 방향성 표시기는 납으로 만들어진 일반적인 표시기가 없이도 전후좌우와 다양한 각도로 경사진 방향을 구분할 수 있게 한다. 또한 방향성 표시기는 film/cassette holder에 부착함으로써 simulation 시에도 이용될 수 있다. 결론: Fiduciary plate는 치료 영역 확인에 유용하고, 수은을 이용한 방향성 표시기내의 혼합액의 기하학적인 모양에 따라 port film의 촬영 parameter를 용이하게 파악할 수 있어 치료과정에서 촬영한 port film 간의 임상정도관리에 유용한 방법이 될 수 있다.
We investigated domains and conoscope under the polarizing microscope and the index of refraction on the c-plate GMO which has the ferroelectric and ferroelastic phase at room temperature. To observed the change of refractive index in connection with domain, we developed an apparatus to obtain the refractive index by measuring the Brewster's angle. The resolution of the minimum rotation angle of this apparatus is $0.001^{\circ}$. To obtain the refractive index map on the sample, the moving distance of XY stage loaded sample holder is 60 mm and the minimum moving distance is 0.002 mm. Also, To obtain the indicatrix for single crystal, vertical turntable with sample holder and XY stage was loading on horizontal turntable. The minimum resolution angle of this vertical turntable is $0.001^{\circ}$. We measured the refractive index of transparent materials such as ferroelectrics. In the case of $Gd_{2}(MoO_{4})_{3}$, the Brewster angle is $62.11^{\circ}$ and then, the refractive index is 1.8895 by using He-Ne Laser. Also the refractive distribution of c-plate GMO was obtained with $400{\mu}m{\times}120{\mu}m$.
Sheanng is one of the most important operating processes in the field of sheet metal manufacturing. Compared with casting, forging and machining, shearing is very economical to obtain the desired shape. In recent years there has been increasing the use of shearing process in the manufacturing of small and light electronic components. In this paper, it has been researched the experimental investigation to examine the mfl uence of shearing process parameters such as clearance and lower holder configuration. Through the experiment results, the more narrow clearance gives the smaller burr height and the removal of lower holder makes the worse sheared surface. And FE simulation of shearing process using DEFORM-2D were camed out and the results compared w~th experimental studies
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.