• 제목/요약/키워드: Plate height

검색결과 641건 처리시간 0.028초

Energy Modeling of a Supertall Building Using Simulated 600 m Weather File Data

  • Irani, Ali;Leung, Luke;Sedino, Marzia
    • 국제초고층학회논문집
    • /
    • 제8권2호
    • /
    • pp.101-106
    • /
    • 2019
  • Assessing the energy performance of supertall buildings often does not consider variations in energy consumption due to the change of environmental conditions such as temperature, pressure, and wind speed associated with differing elevations. Some modelers account for these changing conditions by using a conventional temperature lapse rate, but not many studies confirm to the appropriateness of applying it to tall buildings. This paper presents and discusses simulated annual energy consumption results from a 600 m tall skyscraper floor plate located in Dubai, UAE, assessed using ground level weather data, a conventional temperature lapse rate of $6.5^{\circ}C/km$, and more accurate simulated 600 m weather data. A typical office floorplate, with ASHRAE 90.1-2010 standards and systems applied, was evaluated using the EnergyPlus engine through the OpenStudio graphical user interface. The results presented in this paper indicate that by using ground level weather data, energy consumption at the top of the building can be overestimated by upwards of 4%. Furthermore, by only using a lapse rate, heating energy is overestimated by up to 96% due to local weather phenomenon such as temperature inversion, which can only be conveyed using simulated weather data. In addition, sizing and energy consumption of fans, which are dependent both on wind and atmospheric pressure, are not accurately captured using a temperature lapse rate. These results show that that it is important, with the ever increasing construction of supertall buildings, to be able to account for variations in climatic conditions along the height of the building. Adequately modeling these conditions using simulated weather data will help designers and engineers correctly size mechanical systems, potentially decreasing overall building energy consumption, and ensuring that these systems are able to provide the necessary indoor conditions to maintain occupant comfort levels.

달리기 시 인솔의 굽힘 강성 증가에 따른 발목과 중족골 관절의 운동학적 변인 및 관절 협응에 미치는 영향 (The Effects on Kinematics and Joint Coordination of Ankle and MTP Joint as Bending Stiffness Increase of Shoes during Running)

  • Kim, Sungmin;Moon, Jeheon
    • 한국운동역학회지
    • /
    • 제31권3호
    • /
    • pp.205-213
    • /
    • 2021
  • Objective: The aim of this study was to analyze body stability Joint coordination pattern though as bending stiffness of shoes during stance phase of running. Method: 47 male subjects (Age: 26.33 ± 2.11 years, Height: 177.32 ± 4.31 cm, Weight: 65.8 ± 3.87 kg) participated in this study. All subjects tested wearing the same type of running shoes by classifying bending stiffness (A shoes: 3.2~4.1 N, B shoes: 9.25~10.53 N, C shoes: 20.22~21.59 N). They ran 10 m at 3.3 m/s (SD ±3%) speed, and the speed was monitored by installing a speedometer at 3 m intervals between force plate, and the measured data were analyzed five times. During running, ankle joint, MTP joint, coupling angle, inclination angle (anterior-posterior, medial-lateral) was collected and analyzed. Vector coding methods were used to calculate vector angle of 2 joint couples during running: MTP-Ankle joint frontal plane. All analyses were performed with SPSS 21.0 and for repeated measured ANOVA and Post-hoc was Bonferroni. Results: Results indicated that there was an interaction between three shoes and phases for MTP (Metatarsalphalangeal) joint angle (p = .045), the phases in the three shoes showed difference with heel strike~impact peak (p1) (p = .000), impact peak~active peak (p2) (p = .002), from active peak to half the distance to take-off until take-off (p4) (p = .032) except for active peak~from active peak to half the distance to take-off (p3) (p = .155). ML IA (medial-lateral inclination angle) for C shoes was increased than other shoes. The coupling angle of ankle angle and MTP joint showed that there was significantly difference of p2 (p = .005), p4 (p = .045), and the characteristics of C shoes were that single-joint pattern (ankle-phase, MTP-phase) was shown in each phase. Conclusion: In conclusion, by wearing high bending stiffness shoes, their body instability was increased during running.

Comparison of Vertical Ground Reaction Forces during Jump between Elderly and Young Adults using Nintendo Wii Balance Board

  • Lim, Jiyoung;Yu, Deokhyeon;Kim, Chaeyoung;Park, Daesung
    • Physical Therapy Rehabilitation Science
    • /
    • 제10권2호
    • /
    • pp.161-166
    • /
    • 2021
  • Objective: The purpose of this study was to quantitatively evaluate the Wii Balance Board (WBB)-based jump performance for the elderly and to confirm the difference in jump performance according to age. Design: Cross-sectional study. Methods: 40 young adults (aged 22.5±2.2 years) and 33 elderly (aged 75.1±5.2 years) without orthopedics disease participated in this study. Standing on the WBB then, with the signal "start," jump vertically to the maximum height at which you can jump, land on the force plate after jump and keep it standing on both feet. All subjects were required to practice the jump sufficiently before starting the measurement, each measuring three times, and the mean values were used. A one-minute break was provided between each trial. Evaluators waited within 1meter for every test to prepare for fall. Results: The vertical ground reaction force of elderly and young adults when jumping using WBB showed a significant difference (p<0.05) and demonstrated discriminant validity. Between two groups, there were significant differences in overall jump time (p<0.05), maximum value (p<0.05), minimum value (p<0.05), center of pressure (COP) pathlength (p<0.05), and flight time p<0.05). Conclusions: This study found that performing the vertical jump, the elderly showed longer jump time, lower vertical ground reaction force, COP pathlength and shorter flight phase than healthy young adults using WBB and demonstrated that as a measurement tool, WBB discriminated vertical jump performance between elderly and young adults.

Root proximity of the anchoring miniscrews of orthodontic miniplates in the mandibular incisal area: Cone-beam computed tomographic analysis

  • Jeong, Do-Min;Oh, Song Hee;Choo, HyeRan;Choi, Yong-Suk;Kim, Seong-Hun;Lee, Jin-Suk;Hwang, Eui-Hwan
    • 대한치과교정학회지
    • /
    • 제51권4호
    • /
    • pp.231-240
    • /
    • 2021
  • Objective: This outcome analysis study evaluated the actual positions of the orthodontic miniplate and miniplate anchoring screws (MPASs) and the risk factors affecting adjacent anatomic structures after miniplate placement in the mandibular incisal area. Methods: Cone-beam computed tomographic images of 97 orthodontic miniplates and their 194 MPASs (diameter, 1.5 mm; length, 4 mm) in patients whose miniplates provided sufficient clinical stability for orthodontic treatment were retrospectively reviewed. For evaluating the actual positions of the miniplates and analyzing the risk factors, including the effects on adjacent roots, MPAS placement height (PH), placement depth (PD), plate angle (PA), mental fossa angle (MA), and root proximity were assessed using the paired t-test, analysis of variance, and generalized linear model and regression analyses. Results: The mean PDs of MPASs at positions 1 (P1) and 2 (P2) were 2.01 mm and 2.23 mm, respectively. PA was significantly higher in the Class III malocclusion group than in the other groups. PH was positively correlated with MA and PD at P1. Of the 97 MPASs at P1, 49 were in the no-root area and 48 in the dentulous area; moreover, 19 showed a degree of root contact (19.6%) without root perforation. All MPASs at P2 were in the no-root area. Conclusions: Positioning the miniplate head approximately 1 mm lower than the mucogingival junction is highly likely to provide sufficient PH for the P1-MPASs to be placed in the no-root area.

Development and feasibility test of sit-to-stand transfer assistive device

  • Ha, SinHo;Jeong, SeYeon;Hong, SoungKyun;Choi, Wonjae;Lee, Kwangkook;Park, Donghwan;Son, SangJun;Shin, HyeonHui;Lee, GyuChang
    • 대한물리치료과학회지
    • /
    • 제29권1호
    • /
    • pp.41-46
    • /
    • 2022
  • Background: The purpose of this study was to develop a sit-to-stand transfer assistive device, and to conduct a feasibility test. Design: A technical note. Methods and results: In this study, we developed a sit-to-stand transfer assistive device for the elderly and the disabled who have difficulty standing up independently from sitting positions. The sit-to-stand transfer assistive device allows the user to transfer the weight from a sitting position to a standing position while shifting the weight forward by grabbing and pulling a support stand. Ten healthy adults participated in the feasibility test of the device. Each participant used the developed sit-to-stand transfer assistive device and investigated supplementation through a brief interview. As a result of the feasibility test, the opinion was that the device could assist the sit-to-stand transfer to some extent. There were opinions that it needed a function to adjust the height of the knee protective plate in the sitting position according to the user's physical characteristics. Because of the inconvenience of operating the lock device for fixing the position and adjusting inclination, there was an opinion that the improvement for a locking device is needed. There were opinions that it would be better to reduce the size of the device due to its inconvenience of portability. Conclusion: In this study, we developed the sit-to-stand transfer assistive device for the elderly and the disabled who have difficulty standing up independently from sitting positions. In addition, it is considered that the upgrade of the device is necessary for the future since there are supplementary opinions on some points.

A modified method of augmented distal clavicle fracture osteosynthesis with a Fibertape coracoclavicular cerclage

  • Wu, ChengHan;Teo, Timothy Wei Wen;Wee, Andy Teck Huat;Toon, Dong Hao
    • Clinics in Shoulder and Elbow
    • /
    • 제25권3호
    • /
    • pp.230-235
    • /
    • 2022
  • Background: Unstable distal clavicles experience high non-union rates, prompting surgeons to recommend surgery for more predictable outcomes. There is a lack of consensus on the optimal method of surgical fixation, with an array of techniques described in the literature. We describe an alternative method of fixation involving the use of a distal clavicular anatomical locking plate with Fibertape cerclage augmentation in our series of patients. Methods: Nine patients (8 males and 1 female), with a mean age of 36 years, who sustained unstable fracture of the distal clavicle in our institution were treated with our described technique. Postoperative range of motion, functional and pain scores, and time to radiographic union were measured over a mean follow-up period of 10 months. Incidences of postoperative complications were also recorded. Results: At the last patient consult, the mean visual analog scale score was 0.88±0.35, with a mean Disabilities of the Arm, Shoulder, and Hand (DASH) score of 1.46±0.87 and American Shoulder and Elbow Surgeons (ASES) score of 94.1±3.57. The mean range of motion achieved was forward flexion at 173°±10.6°, abduction at 173°±10.6°, and external rotation at 74.4°±10.5°. All patients achieved internal rotation at a vertebral height of at least L2 with radiographical union at a mean of 10 weeks. No removal of implants was required. Conclusions: Our described technique of augmented fixation of the distal clavicle is effective, produces good clinical outcomes, and has minimal complications.

초전도 부상자석을 이용한 동적 및 정지형 반발식 자기부상 시험기의 수치해석 (Numerical Analysis of Moving Type and Static Type Electrodynamic Suspension Simulator with Superconducting Levitation Magnet)

  • 이응로;배덕권;정윤도;윤용수;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권1호
    • /
    • pp.49-54
    • /
    • 2009
  • This paper presents the numerical simulation results on the moving type electrodynamic suspension (EDS) simulator and static type EDS simulator using high-Tc superconducting (HTS) levitation magnet. The levitation force of the EDS system is formed by the reaction between the moving magnet and the fixed ground conductor. The possible two ways to simulate the EDS system were simulated in this paper by using finite element method (FEM). The first way was the moving type simulator which consists of the fixed HTS magnet and the moving ground conductor. The second way was the static type simulator which consists of the fixed magnet, the fixed ground conductor and the ac current supply system. To verify the characteristics of high speed EDS system with the moving type simulator heavy, large and fast moving ground conductor is needed. The static type simulator can get the characteristics of the high speed EDS system by applying equivalent ac current to velocity, therefore it does not need large moving part. The static type EDS simulator, which can consist of an HTS magnet, the fixed ground conductor(s), an AC power supply and the measuring devices, also test the effect of the shape of the ground conductor easily. The plate type ground conductor made stronger levitation force than ring type ground conductor. Although the outer diameter 335 mm ring type ground conductor (Ring3) was larger than the outer diameter 235 mm ground conductor (Ring2), the levitation force by Ring2 was stronger than that by Ring3. From the calculation results on this paper, the consideration of the magnetic flux distribution according to the levitation height should be included in the process of the ground conductor design.

유공강판 전단연결재의 인발저항성능 평가 (Pull-out Resistance Capacity Evaluation of Perfobond Rib Shear Connector)

  • 김영호;구현본
    • 대한토목학회논문집
    • /
    • 제28권6A호
    • /
    • pp.853-859
    • /
    • 2008
  • 본 연구에서는 유공강판 전단연결재를 강관말뚝머리 연결부의 결합용 구조 요소로 활용하기 위한 연구의 일환으로 유공강판 전단연결재의 홀 형상, 홀 직경, 홀 관통철근, 매입깊이 등에 따른 구조적 성능 및 거동 특성을 실험적으로 규명하였으며, 그 결과 유공강판 전단연결재가 충분한 인발저항성능을 확보하기 위해서는 콘크리트 다웰 효과가 충분히 발현될 수 있도록 확보가능한 만큼의 다수의 홀을 가공 배치하되, 각 홀의 직경은 전단연결재 높이의 절반 정도임과 동시에 관통철근 배근 후에도 콘크리트의 완전한 충전이 가능할 만큼의 홀 내 여유 공간을 충분히 확보하는 것이 바람직하며, 아울러 유공강판 전단연결재가 강관말뚝머리 연결부의 결합용 구조 요소로서의 제기능을 발휘할 수 있도록 충분한 정착성능을 확보할 필요가 있다.

편광 기반 주파수 스캐닝 간섭 시스템 및 병렬 프로그래밍 기반 측정 고속화 (A Polarization-based Frequency Scanning Interferometer and the Measurement Processing Acceleration based on Parallel Programing)

  • 이승현;김민영
    • 전자공학회논문지
    • /
    • 제50권8호
    • /
    • pp.253-263
    • /
    • 2013
  • 광학측정기법 중 주파수 스캐닝 간섭계는 기존 3차원 측정기법과 비교하여 광학 하드웨어 구조가 측정과정동안 고정되어 있어, 대물렌즈나 대상물체의 수직 스캐닝 없이 단지 광원의 주파수만 특정한 주파수 밴드내에서 스캐닝 하여 대상물체에 주사되므로, 우수한 광학 측정 성능을 보인다. 광원의 주파수를 변경하여 간섭계를 통해 간섭 영상을 획득한 후, 밝기 영상 데이터를 주파수 영역 데이터로 변환하고, 고속 푸리에 변환을 통한 주파수 분석을 이용하여 대상 물체의 높이 정보를 계측한다. 하지만, 대상물체의 광학적 특성에 기인한 광학노이즈와 주파수 스캐닝동안 획득되는 영상의 수에 따라 증가하는 영상처리시간은 여전히 주파수 스캐닝 간섭계의 문제이다. 이를 위해, 1) 편광기반 주파수 스캐닝 간섭계가 광학 노이즈에 대한 강인성을 확보하기 위해 제안되어진다. 시스템은 주파수 변조 레이저, 참조 거울 앞단의 ${\lambda}/4$ 판, 대상 물체 앞단의 ${\lambda}/4$ 판, 편광 광분배기, 이미지 센서 앞단의 편광기, 광섬유 광원 앞단의 편광기, 편광 광분배기와 광원의 편광기 사이에 위치하는 ${\lambda}/2$ 판으로 구성된다. 제안된 시스템을 이용하여, 편광을 기반으로한 간섭이미지의 대조대비를 조절할 수 있다. 2) 신호처리 고속화 방법이 간섭계 시스템을 위해 제안되며, 이는 그래픽 처리 유닛(GPU)과 같은 병렬처리 하드웨어와 계산 통합 기기 구조(CUDA)와 같은 프로그래밍 언어로 구현된다. 제안된 방법을 통해 신호처리 시간은 실시간 처리가 가능한 작업시간을 얻을 수 있었다. 최종적으로 다양한 실험을 통해 제안된 시스템을 정확도와 신호처리 시간의 관점으로 평가하였고, 실험결과를 통해 제안한 시스템이 광학측정기법의 실적용을 위해 효율적임을 보였다.

국립중앙박물관 소장 포천 출토 철조여래좌상에 대한 소고 (An Inquiry into the Iron Seated Buddha Excavated from Pocheon in the National Museum of Korea)

  • 강건우
    • 미술자료
    • /
    • 제96권
    • /
    • pp.209-223
    • /
    • 2019
  • 국립중앙박물관 소장 철조여래좌상은 한동안 미등록 상태로 박물관 수장고에 보관되어 있었다가 최근 본관9976으로 유물번호가 새롭게 변경되었다. 이 철조여래좌상은 '포천 철불'로 불리는 철조여래좌상(본관9975)과 함께 경기도 포천군 이동면 백운리 흥룡사 일대에서 발견된 불상이다. 필자는 일제강점기 조선총독부박물관 공문서와 유리건판 사진 등을 비교·검토하여 두 구의 철조여래좌상이 동일한 절차를 거쳐 1925년 12월 17일에 조선총독부박물관으로 이관되었음을 확인할 수 있었다. 철조여래좌상은 높이가 105cm, 어깨폭은 57cm, 무릎폭은 77cm에 이르고, 편단우견(偏袒右肩)의 착의법에 옷주름은 물결무늬식으로 새겨서 유려하다. 철조여래좌상의 얼굴은 타원형으로 이목구비의 묘사가 잘 남아있다. 양감 있는 볼에 넓게 타원형을 그린 안와, 수직으로 길게 뻗은 눈, 짧은 코와 도툼한 입술은 9세기에 제작된 전라북도 남원 실상사(實相寺) 철조여래좌상, 경북 예천 한천사(寒天寺) 철조여래좌상, 강원도 동해시 삼화사(三和寺) 철조여래좌상 등과 유사하다. 또한 결가부좌한 다리와 편단우견의 착의법, 물결무늬식 옷주름은 8세기 석굴암 본존불을 연상시킬 만큼 조각수법이 우수하다고 생각된다. 철조여래좌상의 존명은 유리건판 사진(원판번호 M442-2, M442-7)을 통해 알 수 있다. 유리건판 사진을 보면 오른쪽 손바닥은 위를 향하고, 왼쪽 손바닥으로 약기(藥器)를 받치고 있다. 지금까지 원주 출토 철조약사좌상(본관1970)만이 철로 만든 유일한 약사불상으로 알려져 있었는데, 이번에 약기를 든 철조약사여래좌상을 새롭게 확인할 수 있었다. 철조여래좌상은 혜철의 제자 도선(道詵)(827~898)이 밀교신앙의 영향을 받아 사찰을 보호하고 국토를 비보(裨補)하기 위해 9세기경에 조성했을 가능성이 있다. 흥룡사의 전신인 내원사에는 도선이 백운산 등 중요한 세 곳을 택하여 비보사원을 세우고 다시 약사여래삼존상을 조성한 후 사원에 봉안했다는 기록이 남아있다. 또한 「선암사중수비」에는 도선이 비보를 위해 도량을 세우고 철불 등을 조성했다고 전한다. 흥룡사가 소재한 경기도 포천시 이동면 도평리에 고려시대에 약사(藥寺)라는 사찰이 창건되었다는 점에서, 이 일대는 약사도량과 관련된 지역이었던 것으로 생각된다.