• Title/Summary/Keyword: Plate height

Search Result 639, Processing Time 0.029 seconds

A Study of Laminated Evaporator Performance Characteristics through Numerical Analysis (전산해석을 이용한 적층형 증발기 성능특성 연구)

  • 시종민;한창섭;김재훈;우승길
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.3
    • /
    • pp.210-219
    • /
    • 2003
  • A laminated evaporator performance simulation software has been developed and the performance characteristics have been examined with variation of important design parameters, number of plate ( $P_{N}$), plate inner height ( $P_{h}$), Plate thickness ( $p_{t}$) and plate wetted Perimeter ( $P_{wl}$ ). To confirm the program, performance experiment was carried out for two different evaporators. The simulation results matched with experiments within $\pm$10%. Through the parametric studies, $P_{N}$ was shown to be most influential. The $P_{N}$, $P_{h}$ and $P_{wl}$ had a maximum cooling capacity point in the calculation range. In case of $P_{t}$, the smaller was the better.ter.etter.ter.

Experimental Investigation of Wedge Slamming Impact (쐐기 슬래밍에 관한 실험적 연구)

  • Di, Ren;Ahn, Gang-Su;Kwon, Sun-Hong
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.2
    • /
    • pp.163-168
    • /
    • 2015
  • This paper presents the results of experimental work on the wedge slamming impact problem. An experiment was done with a wedge model. The deadrise angle of the wedge was $4^{\circ}$. The model was made in two parts: the outside part was made of a 5-mm-thick steel plate that could be assumed to be a rigid body, and the inside part was made of a thin SUS plate that could be assumed to be an elastic body. Thin SUS plate thicknesses of 2 mm and 3 mm were used to determine the effect of plate rigidity. The drop height was varied from 0.25 m to 1 m to determine the effect of a large deformation.

The Experimental Study of Radiant Cooling Test System under Different Covers (복사냉각 시스템에서 커버의 영향)

  • Byun, Ki-Hong;Smith, Theodore F.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.797-802
    • /
    • 2007
  • The effects of window cover on the performance of the plate type radiant cooling test system are studied. The cover materials tested are 2mm, 1mm, 0.7mm glass, Cokin 007 filter, and PVC film. The measurements are performed during the September nights of 2005 at the rooftop of the building in Seoul. The equivalent height of the building is about a building with twelve floors. The radiant cooling performance of the black painted and aluminum film coated plate are compared under no cover condition. Also the results are compared when the system has cover over the plate. In general, the covers reduce the radiant cooling temperature differences during the nighttime. Among these covers, the PVC film cover shows the best performance. In some cases, the plate with PVC film cover shows lower temperatures than the system without cover.

Seismic Verification of Nuclear Power Plant Equipment Anchorage (원전 기기 정착부의 내진검증 기법 사례연구)

  • 서용표
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.215-223
    • /
    • 2000
  • In this study, the effect of stiffness ratio between base frame and anchorgae is evaluated and the seismic verification of nuclear power plant equipment anchorage is performed for typical equipment. The stiffness ratio between base frame and anchorage is mainly controlled by the effective height of side wall plate. And, the change of that stiffness ratio cause the large shift or ovreturning axis of equipment base. This shift of overturning axis of equipment base is able to reduce the factor of safety about 10%. Therefore, the adequate method for evaluating of effective height of side wall is required as further study.

  • PDF

Static and free vibration behaviour of orthotropic elliptic paraboloid shells

  • Darilmaz, Kutlu
    • Steel and Composite Structures
    • /
    • v.23 no.6
    • /
    • pp.737-746
    • /
    • 2017
  • In this paper the influence of aspect ratio, height ratio and material angle on static and free vibration behaviour of orthotropic elliptic paraboloid shells is studied by using a four-node hybrid stress finite element. The formulation of the element is based on Hellinger-Reissner variational principle. The element is developed by combining a hybrid plane stress element and a hybrid plate element. A parametric study is carried out for static and free vibration response of orthotropic elliptic paraboloid shells with respect to displacements, internal forces, fundamental frequencies and mode shapes by varying the aspect and height ratios, and material angle.

Fatigue Strength Assessment and Improvement of Butt Welding Bead (피로해석을 통한 버트 용접 부위 비드 개선)

  • Suk Yongsuk;Han Sangmin
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2005.06a
    • /
    • pp.192-197
    • /
    • 2005
  • A welding bead height is closely related to the efficiency of welding work, and the height of 3mm is used in the conventional practice of butt welding. in the present paper, the modification of bead height from 3mm to 6mm is considered to increase the efficiency and work productivity of butt welding on bottom plate (of BONGA FPSO actually built in SHI shipyard). Therefore, fatigue analysis has been carried out using simplified method based on the DNV Rules. It is found that the minimum fatigue life is about 594 years and the butt welding details with 6mm bead height has sufficient strength and resistance against fatigue.

  • PDF

A SUTDY ABOUT THE SHAPE OF THE FRAMEWORK OF THE FIXED BONE ANCHORED BRIDGE USING DENIAL IMPLANTS (임프란트를 이용한 고정성 계속가공의치의 FRAMEWORK 형태에 관한 연구)

  • Kim, Te-Gyun;Lee, Young-Soo;Yoo, Kwang-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.104-119
    • /
    • 1998
  • The purpose of this study was pertinent design of the framework of the fixed bone anchored bridge using implants in the edentulous mandible through analysis of stress distribution by the three dimensional finite element analysis method. The results were as follows: 1. The L-shaped framework was favorable in restoring the edentulous mandible by implants and fixed bone anchored bridge. 2. The structure of the framework should be designed to endure the occlusal load because of stress concentration at the most distal abutment of the framework. 3. The stress at the distal implant where cantilever starts was twice as much as that of other portions. 4. Compressive stress was generated on the framework of the mesial side of the distal implant and extrusive force was induced to the mesially positioned implants. 5. The height of vertical plate was high as possible as can be to distribute stresses concentrating bucco-lingually and labio-lingually in the framework between abutments, 6. Reinforcement of the horizontal plate thickness was needed because stress was loaded more on the horizontal plate than on the vertical plate of the framework. 7. Lengthening of the vertical plate can compensate for any limitations in horizontal plate width.

  • PDF

Cooling Characteristics of a Hot Steel Plate by a Circular Impinging Liquid Jet (원형수직 충돌 수분류에 의한 고온강판의 냉각특성 연구)

  • 오승묵;이상준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.6
    • /
    • pp.1150-1155
    • /
    • 1992
  • The cooling characteristics of a hot steel plate by a laminar impinging water bar were investigated experimentally. The dynamic parameters investigated were nozzle height L between nozzle and the hot plate, flow rate Q, and initial cooling temperature. Because the boiling phenomena on a hot steel plate are unsteady and change discontinuously, it is difficult to analyze the cooling characteristics directly. In this study the cooling efficiency was estimated by using the temperature decay rates and expansion speed of the water cooling zone. Temperature in the water cooling zone decreased rapidly and the radius of the water cooling zone expanded nearly in proportion to square root of the cooling time. With increasing initial temperature of a hot steel plate, the cooling efficiency became descendent. The cooling curve in the case of L/D = 30 showed the largest temperature decay rate and excellent cooling performance.

Reduction Characteristics of Electromagnetic Penetration through a Slit in a Conducting Screen by a Loaded Triangle Plate (삼각형 도체판 장하에 의한 무한 도체 평판 슬릿의 침투 전자파 저감 특성)

  • Cho, Byung-Ho;Lee, Seung-Ik;Kim, Hyo-Kyun;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.7
    • /
    • pp.767-773
    • /
    • 2014
  • This paper presents the reduction characteristics of electromagnetic penetration through a slit in conducting screen by loaded plate. The FDTD method is used in theoretical analysis. And the characteristics of penetrated electric fields are calculated in terms of length, width, shape, position, and height of the loaded plate to find out how the geometry of plate influences the reduction characteristics of the electromagnetic penetration and shielding effectiveness. The results show that the characteristics of penetrated electric field and shielding effectiveness depend on the geometry of loaded plate. In particular, the optimal geometry of loaded plate which minimize penetrated electric field are verified.