• Title/Summary/Keyword: Plate fixation

Search Result 343, Processing Time 0.026 seconds

Comparison of Mechanical Stability between Fibular Free Flap Reconstruction versus Locking Mandibular Reconstruction Plate Fixation

  • Chung, Jae-Hyun;Yoon, Eul-Sik;Park, Seung-Ha;Lee, Byung-Il;Kim, Hyon-Surk;You, Hi-Jin
    • Archives of Craniofacial Surgery
    • /
    • v.15 no.2
    • /
    • pp.75-81
    • /
    • 2014
  • Background: The fibular free flap has been used as the standard methods of segmental mandibular reconstruction. The objective of mandibular reconstruction not only includes restored continuity of the mandible but also the recovery of optimal function. This paper emphasizes the advantage of the fibular free flap reconstruction over that of locking mandibular reconstruction plate fixation. Methods: The hospital charts of all patients (n=20) who had a mandibular reconstruction between 1994 and 2013 were retrospectively reviewed. Eight patients had plateonly fixation of the mandible, and the remaining 12 had vascularized fibular free flap reconstruction. Complications and outcomes were reviewed and compared between the 2 groups via statistical analysis. Results: Overall complication rates were significantly lower in the fibular flap group (8.3%) than in the plate fixation group (87.5%; p =0.001). Most (7/8) patients in the plate fixation group had experienced plate-related late complications, including plate fracture or exposure. In the fibular flap group, no complications were observed, except for a single case of donor-site wound dehiscence (1/12). Conclusion: The fibular free flap provides a more stable support and additional soft tissue support for the plate, thereby minimizing the risk of plate-related complications. Fibular free flap is the most reliable option for mandibular reconstruction, and we believe that the flap should be performed primarily whenever possible.

Open Reduction and Internal Fixation (ORIF) of Trapdoor Orbital Floor Blowout Fracture with Absorbable Mesh Plate (뚜껑문 안와저 골절에 있어서 망상 흡수성 판을 이용한 관혈적 정복술 및 내고정술)

  • Kwon, Yu-Jin;Kim, Ji-Hoon;Hwang, Jae-Ha;Kim, Kwang-Seog;Lee, Sam-Yong
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.619-625
    • /
    • 2010
  • Purpose: Trapdoor orbital blowout fracture is most common in orbital blowout fracture. Various materials have been used to reconstruct orbital floor blowout fracture. Absorbable alloplastic implants are needed because of disadvantages of nonabsorbable alloplastic materials and donor morbidity of autogenous tissue. The aim of the study is to evaluate usefulness of absorbable mesh plate as a reconstructive material for orbital blowout fractures. Methods: From December 2008 to October 2009, 18 trapdoor orbital floor blowout fracture patients were treated using elevator fixation, depressor fixation, or elevatordepressor fixation techniques with absorbable mesh plates and screw, depending on degree of orbital floor reduction, because absorbable mesh plates are less rigid than titanium plates and other artificial substitutes. Results: Among 18 patients, 5 elevator fixation, 4 depressor fixation, and 9 elevator and depressor fixation technique were performed. In all patients, postoperative computed tomographic (CT) scan showed complete reduction of orbital contents and orbital floor, and no displacement of bony fragment and mesh plate. Mean follow-up was 10 months. There were no significant intraoperative or postoperative complications. Conclusion: Three different techniques depending on the degree of orbital floor reduction are useful for open reduction and internal fixation of trapdoor orbital floor blowout fracture with absorbable mesh plates.

Acromion Fracture after Hook Plate Fixation for Distal Clavicle Injury: A Report of 2 Cases

  • Kang, Suk;Lee, Ho Min;Back, In Hwa
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.3
    • /
    • pp.168-171
    • /
    • 2016
  • Fractures at the lateral end of the clavicle inevitably require surgical treatment as there is high potential for delayed union or nonunion. Acromioclavicular dislocation also requires stable and solid fixation for healing, and surgical treatment is recommended for the maintenance of joint function. The hook plate maintains the biomechanics of the acromioclavicular joint, enabling early range of motion. Therefore, for the past 10 years, the hook plate has been widely used in distal clavicle fractures and acromioclavicular joint injuries. However, the hook plate is associated with several complications, such as proximal clavicle fractures, widening of the hook hole, rotator cuff tear, subacromial impingement, and often acromial fractures. We report on two unusual cases of acromion fracture after hook plate fixation in patients with distal clavicle fracture and acromioclavicular dislocation alongside a literature review.

Can bone marrow aspirate improve mandibular fracture repair in camels (Camelus dromedarius)? A preliminary study

  • Al-Sobayil, Fahd;Sadan, Madeh A.;El-Shafaey, El-Sayed;Ahmed, Ahmed F.
    • Journal of Veterinary Science
    • /
    • v.21 no.6
    • /
    • pp.90.1-90.11
    • /
    • 2020
  • Background: Mandibular fractures are common in camels, leading to considerable economic losses. This study explored methods of improving mandibular fractures repair, adjuvant with interdental wire, or bone plate fixation. Autologous bone marrow (BM) injection enhances osteogenesis and rapid healing. Objectives: To investigate the effect of autologous BM aspirate as an adjuvant treatment for repairing mandibular fractures in camels with interdental wire, or bone plate fixation. Methods: Thirty dromedary camels aged 5-8 years and of both sexes were randomly divided into 4 treatment groups: group 1 (n = 10) treated with stainless steel wire fixation and BM injection at the fracture line, group 2 (n = 10) treated with plate fixation and BM injection at the fracture line, group 3 (n = 5) treated with stainless steel bone wire fixation and placebo saline injection at the fracture line, and group 4 (n = 5) treated with plate fixation and placebo injection at the fracture line. The mandibular fractures were followed weekly for 12 weeks postoperatively to assess improvement and healing based on clinical evaluation, radiographic union scale, and bone turnover markers (i.e., bone alkaline phosphatase, osteocalcin, pyridinoline, and deoxypyridinoline). Results: Compared to other groups, elevated bone turnover markers in group 1 were demonstrated (p < 0.05) on the seventh postoperative day. Likewise, compared to other groups, both clinical findings and radiographic union scale significantly improved (p < 0.05) in group 1 on the 56th postoperative day. Conclusions: BM aspirate has a promising beneficial osteogenic effect on mandibular fracture repair in camels, most notably when combined with interdental wire fixation.

Treatment of Fractures of the Lateral Malleolus using Locking Compression Plate (Locking Compression Plate를 이용한 족근 관절 외과 골절의 치료)

  • Ha, Sung-Sik;Hong, Ki-Do;Chung, Nam-Sik;Sim, Jae-Cheon;Ahn, Sang-Cheon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.1
    • /
    • pp.99-104
    • /
    • 2005
  • Purpose: The purpose of this study was to investigate usefulness of locking compression plate (LCP) as an open reduction technique by evaluating clinical results obtained from the patients with lateral malleolar fracture treated by internal fixation using LCP after open reduction. Materials and Methods: Among the patients with lateral malleolar fracture, the 28 patients who were treated by internal fixation using Locking compression plate after an open reduction and were able to be followed up for more than 6 months were included in this study. Final postoperative evaluation was done based on the Meyer's clinical and radiologic evaluation system. Results: All cases achieved anatomical reduction and fixation of the reduction postoperatively. 28 minutes were taken meaningly from the incision to the fixation of LCP plate after the anatomical reduction. Everage bony union time was 8.2 weaks, and the result was excellent in 23 cases (82%), good in 5 cases (17%) and poor result was abscent according to the criteria of Meyer et al. One case of post traumatic arthritis and one case of superficial infection on the operation site were found, but non-union, delayed union and malunion were not occurred. Conclusion: The internal fixation after open reduction using LCP is an effective treatment method in treating lateral malleolar fracture of the ankle since it offers advantages including easy application and a greater stability due to its capability of maintaining exact anatomical reduction even though the screw does not penetrate the medial cortex of fibular to add the stability and rigidity of the fixation.

  • PDF

Clinical Outcome of a Precontoured Symphysis Pubis Plate with Tension Band Wiring for Traumatic Symphysis Pubis Rupture in Pelvic Fractures

  • Lee, Jeong Moon;Yoon, Sun Jung;Park, Myung Sik;Song, Kyung Jin
    • Journal of Trauma and Injury
    • /
    • v.29 no.1
    • /
    • pp.22-27
    • /
    • 2016
  • Purpose: The optimal method of fixation of symphysis pubis (SP) diastasis in pelvic ring injuries is still controversial. In this study, we investigated the radiological and the clinical results of a precontoured 4.5-mm symphysis pubis (SP) plate with tension band wiring (TBW) after an anterior pelvic injury in pelvic fractures. Methods: We treated 25 patients with traumatic SP diastasis by open reduction and internal fixation with plates and wires. We used a four-hole 4.5-mm precontoured SP plate with a tension band wiring. Results: Patients with a SP with TBW fixation achieved excellent or good results at final follow-up. Post-operative complications included two (8%) patients with metal work movement. The mean symphyseal width was smaller in 4.5 mm SP plate with TBW during 1-year follow up period. Conclusion: A precontoured symphysis pubis plate (4.5 mm) with figure-of-eight fashion tension band wiring shows favorable radiological results, excellent or good clinical outcome, and a lower complication (hardware failure and revision surgery).

Use of a Y-Shaped Plate for Intermaxillary Fixation

  • Kim, Tae Hoon;Yang, Il Hyung;Minn, Kyung Won;Jin, Ung Sik
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.2
    • /
    • pp.96-98
    • /
    • 2015
  • Maxillomandibular fractures usually require intermaxillary fixation as a means to immobilize and stabilize the fracture and to re-establish proper occlusion. Arch bars or intermaxillary fixation screws cannot be used for edentulous patients or for patients who have poor dental health. Here, we present a case of repeated intermaxillary fixation failure in a patient weak alveolar rigidity secondary to multiple dental implants. Because single-point fixation screws were not strong enough to maintain proper occlusion, we have used Y-shaped plates to provide more rigid anchoring points for the intermaxillary wires. We suggest that this method should be considered for patients in whom conventional fixation methods are inappropriate or have failed.

Three-dimensional finite element analysis of the stress distribution and displacement in different fixation methods of bilateral sagittal split ramus osteotomy

  • Yun, Kyoung In;Cho, Young-Gyu;Lee, Jong-Min;Park, Yoon-Hee;Park, Myung-Kyun;Park, Je Uk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.5
    • /
    • pp.271-275
    • /
    • 2012
  • Objectives: This study evaluated a range of fixation methods to determine which is best for the postoperative stabilization of a mandibular osteotomy using three-dimensional finite element analysis of the stress distribution on the plate, screw and surrounding bone and displacement of the lower incisors. Materials and Methods: The model was generated using the synthetic skull scan data, and the surface model was changed to a solid model using software. Bilateral sagittal split ramus osteotomy was performed using the program, and 8 different types of fixation methods were evaluated. A vertical load of 10 N was applied to the occlusal surface of the first molar. Results: In the case of bicortical screws, von-Mises stress on the screws and screw hole and deflection of the lower central incisor were minimal in type 2 (inverted L pattern with 3 bicortical repositioning screws). In the case of plates, von-Mises stress was minimal in type 8 (fixation 5 mm above the inferior border of the mandible with 1 metal plate and 4 monocortical screws), and deflection of the lower central incisor was minimal in types 6 (fixation 5 mm below the superior border of the mandible with 1 metal plate and 4 monocortical screws) and 7 (fixation 12 mm below the superior border of the mandible with 1 metal plate and 4 monocortical screws). Conclusion: Types 2 and 6 fixation methods provide better stability than the others.

Treatment of Acute Acromioclavicular Joint Dislocation: Kirschner's Wire Trans-acromial Fixation versus AO Locking Hook Plate Fixation

  • Kim, Young-Jun;Chun, Yong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.3
    • /
    • pp.149-154
    • /
    • 2016
  • Background: The purpose of this study is to compare clinical and radiological outcomes between trans-acromial fixation with Kirschner's wire (K-wire) and AO locking hook plate fixation for acute acromioclavicular (AC) joint dislocation. Methods: This study included 61 patients who underwent either closed reduction and trans-acromial fixation with K-wire (group A, 23 patients) or open reduction and internal fixation with AO locking hook plate (group B, 38 patients). Pain on a visual analogue scale (VAS) score, the University of California Los Angeles (UCLA) shoulder score, the American Shoulder and Elbow Surgeons (ASES) score, and active range of motion (ROM) were used in the functional evaluation. For radiological evaluation, coracoclavicular distance (CCD) was measured on both clavicular anteroposterior view and compared between groups. Results: At one-year follow-up, no significant differences in VAS pain score, UCLA shoulder score, ASES score, and active ROM were observed between groups, despite five cases (22.7%, 5/23) of complication in group A. The side-to-side difference between normal and affected CCD was $2.4{\pm}2.2mm$ in group A and $0.2{\pm}0.7mm$ in group B. This difference showed a statistical significance between groups (p<0.001). Conclusions: For the treatment of acute AC joint dislocation, the K-wire trans-acromial fixation group showed a significantly greater CCD than the AO locking hook plate group. In addition, during the follow-up period, much higher incidence of complication related to implant was observed in the trans-acromial fixation group. Although clinical outcomes between groups were not significantly different, these results should be interpreted carefully.

Comparison of F Calcaneal Plate and Locking Calcaneal Plate Fixation Using an Lateral Extensile Approach to Intra-articular Calcaneal Fractures (종골의 관절 내 골절에서 외측 광범위 도달법을 이용한 F형 금속판 고정술과 잠김 금속판 고정술의 비교)

  • Lee, Yun-Tae;Oh, Hyun-Cheol;Yoon, Han-Kook;Jang, Jae-Won;Jang, Ki-Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.3
    • /
    • pp.175-180
    • /
    • 2012
  • Purpose: To evaluate the radiological and clinical results after open reduction and internal fixation with calcaneal F plate and locking calcaneal plate using lateral extensile approach in the treatment of intra-articular calcaneal fracture Materials and Methods: This study included 34 cases of 33 patients followed up for at least 6 months postoperatively. F plate was applied in 18 cases (Group 1), locking plate was used in 16 cases (Group 2) and compared radiological and clinical results between two groups. Results: Radiollogically, the mean Bohler angle was improved from $5.5^{\circ}$ preoperatively to $20.1^{\circ}$ postoperatively and $18.8^{\circ}$ at the last follow up in group 1 and $8.6^{\circ}$ preoperatively, $21.4^{\circ}$ postoperatively and $20.3^{\circ}$ at last follow up in group 2. Bone union was observed in all cases and 4 cases of screw loosening were noted in Group 1 with extended fracture to anterior process. At the last follow up, both groups showed clinical results in American orthopedic foot and ankle society ankle hindfoot score, 76(77 in Sanders type II and 75 in type III) in group 1 and 72(73 in type II and 70 in type III) in group 2. Conclusion: F plate and locking plate showed firm fixation and satisfactory clinical results in the treatment of intra-articular calcaneal fracture. We suggest applying locking plate in cases with extended fracture to anterior process, considering screw loosenings in those who were treated with F plate fixation.