• Title/Summary/Keyword: Plate fixation

Search Result 345, Processing Time 0.024 seconds

A Comparison between Minimally Invasive Percutaneous Plate Osteosynthesis and Plate Fixation in the Treatment of Clavicle Midshaft Fracture (쇄골 간부 골절의 최소 침습적 경피적 금속판 고정술과 관혈적 수술 비교)

  • Yoo, Seong-Ho;Kang, Suk-Woong;Kim, Bu-Hwan;Song, Moo-Ho;Kim, Yeong-Joon;Park, Gyu-Taek;Kwack, Chang-Hun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.52 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Purpose: To retrospectively compare minimally invasive percutaneous plate osteosynthesis (MIPPO) with open plate fixation for the treatment of clavicle midshaft fracture. Materials and Methods: Between November 2011 to May 2014, 40 cases that were followed for more than 1 year-among all cases of MIPPO and open plate fixation-were analyzed. The study population was divided into two groups: group A included 20 cases of MIPPO and group B included 20 open plate fixation cases. The comparative analysis between the two groups was based on the operative time, bone union, functional evaluation (American Shoulder and Elbow Society score), incision length, pain relief (visual analogue scale, VAS), and complication. Results: The bone union was successful for all the cases, and the functional evaluation scores of the shoulder joint were satisfactory for both groups (p>0.05). The operative time was 47.5 minutes and 58.7 minutes for group A and B, respectively (p<0.05). The incision length for group A was 6.2 cm and that for group B was 10.7 cm with statistical significance (p<0.05). Pain relief (VAS) after surgery for group A showed a quick recuperation in the early stages. For complications, there were 2 cases of dysesthesia and 1 case of malunion due to metal fixation failure in group A. There were 6 cases of dysesthesia and 2 cases of cosmetic problem due to hypertrophic scar in group B. Conclusion: Surgical results of clavicle shaft fracture were satisfactory for both groups, but group A had advantages of shorter operative time, minimal incision length, and better pain relief in the early stages compared with group B. However, we need further evaluations with long-term follow-up results and complications, such as malunion and exposure on radiation.

Management of Displaced Intra-articular Calcaneal Fracture (전위된 관절 내 종골 골절의 치료)

  • Lee, Jun Young;Na, Woong Chae
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.4
    • /
    • pp.137-141
    • /
    • 2015
  • Recently, open reduction and internal fixation has been the treatment of choice for displaced intra-articular calcaneal fractures for many orthopaedic surgeons. However controversy still surrounds the optimal treatment with regard to whether displaced intra-articular calcaneal fractures should be treated operatively or conservatively. Conservative treatments include use of splint, rest, leg elevation, icing, use of analgesics and early mobilization. Operative treatment is open reduction and internal fixation, performed through an extensile lateral approach with interfragmentary screws and application of a neutralization plate. We reviewed the question of whether operative treatment by open reduction and internal fixation provides a benefit compared with conservative treatment for displaced intra-articular calcaneal fractures.

Complications Associated with Monocortical Titanium Miniplate used in Rigid Fixation of Mandibular Fractures (하악골 골절의 견고고정에 사용된 monocortical titanium miniplate와 관련된 감염증에 관한 연구)

  • Kim, Young-Kyun;Yeo, Hwan-Ho;Lee, Hyo-Bin;Kim, Kyung-Weon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.4
    • /
    • pp.438-446
    • /
    • 1994
  • Eighty-nine patients with mandibular fracture were treated by open reduction and internal fixation using the monocortical titanium miniplate(Leibinger Co.). Postsurgical intermaxillary fixation was carried out for 2 to 18 days according to the patient's status. Seven patients developed infections postoperatively(7.9%). Five patients were favorably treated by incision and drainage and/or saucerization. But two patients were not controlled by early surgical intervention and should have been followed by plate removal, saucerization and secondary reconstruction including the bone graft. This article reports the postoperative infection associated with miniplate fixation of mandibular fractures and discuss the incidence, cause, treatment and prognosis with careful case analyses.

  • PDF

Comparison of Three Surgical Method Outcomes for Dorsal Communition Distal Radial Fractures: External Fixation, External Fixation with Allogenous Bone Graft (DBM) and Volar Locking Plate Fixation (배측 분쇄가 있는 원위부 요골 관절내 골절의 3가지 수술적 치료 결과 비교: 외고정 기구 단독, 외고정 기구와 동종골이식 및 수장측 잠김 압박 금속판)

  • Choi, Joon-Cheol;Na, Hwa-Yeop;Lee, Young-Sang;Kim, Woo-Sung;Oh, Kyung-Soo;Song, Woo-Suk;Kim, Se-Jun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.2
    • /
    • pp.115-120
    • /
    • 2009
  • Purpose: To evaluate the outcomes of three different surgical approaches in treating a distal radius fracture with dorsal communition. Materials and Methods: From April, 2006 to May, 2009, 49 patients over age of 60years old with unstable dorsal communition distal radius fracture were analyzed. We compared maintainability of reduction by radiological follow-up observations and clinical outcomes using Mayo wrist scores. One-Way ANOVA test was performed to examine the statistical correlation between the methods. Results: All three approaches provided satisfactory post-op reduction results. However, follow-up observations showed significant loss of reduction in the external fixation only group compared to the added bone graft group and the volar anatomical locking plate group (P<0.05). Mayo wrist score was indifferent between the three groups. Conclusion: Treatment of a distal radius fracture with severe dorsal communition using an external fixation only appears to be insufficient in maintaining reduction of a cancellous bone defect.

  • PDF

Ulnar Nerve Injury Caused by the Incomplete Insertion of a Screw Head after Internal Fixation with Dual Locking Plates in AO/OTA Type C2 Distal Humerus Fractures

  • Shin, Jae-Hyuk;Kwon, Whan-Jin;Hyun, Yoon-Suk
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.236-239
    • /
    • 2017
  • After dual plating with a locking compression plate for comminuted intraarticular fractures of the distal humerus, the incidence of ulnar nerve injury after surgery has been reported to be up to 38%. This can be reduced by an anterior transposition of the ulnar nerve but some surgeons believe that extensive handling of the nerve with transposition can increase the risk of an ulnar nerve dysfunction. This paper reports ulnar nerve injuries caused by the incomplete insertion of a screw head in dual plating without an anterior ulnar nerve transposition for AO/OTA type C2 distal humerus fractures. When an anatomical locking plate is applied to a distal humeral fracture, locking screws around the ulnar nerve should be inserted fully without protrusion of the screw because an incompletely inserted screw can cause irritation or injury to the ulnar nerve because the screw head in the locking system usually has a slightly sharp edge because screw head has threads. If the change in insertion angle and resulting protruded head of the screw are unavoidable for firm fixation of fracture, the anterior transposition of the ulnar nerve is recommended over a soft tissue shield.

Minimally Invasive Surgery for Hallux Valgus Deformity Using Intramedullary Low Profile Plate Fixation: A Case Report (소형 금속판의 골수강 내 고정을 통한 최소 침습적 무지 외반증 교정 수술: 증례 보고)

  • Cho, Sung Tan;Suh, Jin Soo;Choi, Jun Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.3
    • /
    • pp.135-138
    • /
    • 2019
  • According to a recent systemic review, hallux valgus deformity has a prevalence rate of about 23% among adults aged 18 to 65 years. To date, more than 100 operative methods have been reported for the correction of hallux valgus deformity. For young female with mild to moderate hallux valgus deformity, minimally invasive surgery can be considered for aesthetic demands. Here, we report a case of a young female patient with mild hallux valgus deformity treated by minimally invasive surgery using intramedullary low profile plate fixation. This can be the favorable method for secure fixation of the osteotomy site and prevention of medial skin irritation symptoms derived from a sharp osteotomy margin.

Dual Plate Fixation for Displaced Transverse Fracture of the Lower Sacrum (전위된 하부 천골 횡골절에 대한 이중 금속판을 이용한 내고정술)

  • Choi, Dong-Hyuk;Park, Ji-Hun;Shim, Seong-Woo;Choi, Yong-Soo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.2
    • /
    • pp.178-182
    • /
    • 2020
  • Isolated fractures of lower sacrum are commonly treated conservatively in most cases because of low energy damage and stable fracture. However, surgical treatment is required in displaced unstable fracture. But the surgical technique is not established and even case reports are not common. We reported a case of displaced transverse fracture of the lower sacrum that was treated with an open reduction and dual plate fixation.

Femoral Shaft Fracture in Klippel-Trenaunay-Weber Syndrome Patients - What to Do to Reduce Bleeding Risk: A Case Report

  • Byung-Chan Cho;Byung-Woo Min;Kyung-Jae Lee
    • Hip & pelvis
    • /
    • v.34 no.4
    • /
    • pp.262-268
    • /
    • 2022
  • A fracture of the affected extremity in patients with Klippel-Trenaunay-Weber syndrome can be fatal due to massive bleeding and show poor results. A 42-year-old male presented with an old fracture of the right femoral shaft with metal failure. We planned an operation to remove the previously fixed plate and to perform re-fixation using an intra-medullary nail. Preoperative angiography was performed and the arteriovenous malformations were embolized in order to reduce the risk of bleeding. After angiography, the previously fixed plate was removed. After the operation, a second angiography was performed immediately and the venous malformation was embolized. One week after the first operation, a second operation was performed in order to reduce the fracture and to perform re-fixation using an intramedullary nail. The patient is being followed without major complication over a period of seven years after surgery. We recommend careful planning of preoperative and postoperative angiography and embolization in order to reduce the risk of bleeding in patients with Klippel-Trenaunay-Weber syndrome.

The Clinical Usefulness of Ultrasound-Aided Fixation Using an Absorbable Plate System in Patients with Zygomatico-Maxillary Fracture

  • Lee, Jong Hun;Park, Jun Hyung
    • Archives of Plastic Surgery
    • /
    • v.40 no.4
    • /
    • pp.330-334
    • /
    • 2013
  • Background Ultrasound-aided fixation is a recently developed alternative method of treatment of zygomatico-maxillary (ZM) fracture, and it can resolve the problems of excessive torsion force and subsequent fractures of screws. We conducted this study to evaluate the clinical usefulness of ultrasound-aided fixation as compared with the conventional fixation method using a drill and an expander in patients with ZM fracture. Methods We conducted a retrospective study in 35 patients with ZM fracture who had been treated at our hospital during a period ranging from March of 2008 to December of 2010. We divided them into two groups: an ultrasound-aided fixation group, comprising 13 patients who underwent ultrasound-aided fixation (SonicWeld Rx, KLS Martin), and a conventional group, comprising 22 patients who underwent conventional fixation (Biosorb FX, Linvatec Biomaterials Ltd.). We compared such variables as sex, direction, age at operation, follow-up period, operation duration, number of fixed holes, and time to discharge between the two groups. Results The ultrasound-aided fixation reduced the operation duration by about 30 minutes as compared with that of conventional fixation. There was no significant difference in follow-up period, number of fixed holes, or time to discharge between the two groups. Furthermore, there were no complications in either group. Conclusions The ultrasound-aided fixation of fractured ZM bone using an absorbable implant system is safe and effective in promptly reducing the bone fracture and providing satisfactory cosmetic outcomes over time.

Implementation of Strength Estimation Algorithm on the Metallic Plate Fixation (금속고정용의 강도 평가 알고리즘 구현)

  • Kin, Jeong-Lae;Kim, Kyo-Ho;Lee, Ki-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.3
    • /
    • pp.45-54
    • /
    • 2009
  • This study was developed the metallic plate for bone fixation in the neurosurgery and general surgery and plates has a finn place in bone operating and treatment. The plates can be realized to bending strength and stiffness for strength estimation. Maximum point of bending curves has a bending point(P) with maximum load which to applied nearly 0.2% offset displacement. The device's sizing has a ${\Phi}13$ and ${\Phi}18$, and algorithm of strength estimation compared a plate(${\Phi}13$, ${\Phi}18$, ${\Phi}13-{\Phi}18$). The bending strength of the curved metallic plate has to evaluate maximum of a 311N, 387N, 410N, 474N. When a displacement preserve with a load, tensile stress through to press a plate is 274N, 324N, 382N, 394N. The algorithm of strength estimation can be used to support estimation of bending strength and stiffness. Their tool bring to settlement in the new basic algorithm for evidence with varied adjustment.

  • PDF