• Title/Summary/Keyword: Plate crown

Search Result 47, Processing Time 0.029 seconds

How Can We Improve Crown-Implant Ratio in Reconstructed Mandible with Fibular Free Flap?: A New Surgical Technique Using 3D RP Model and Reconstruction Titanium Plates

  • Kim, Dong-Young;Ahn, Kang-Min
    • Journal of International Society for Simulation Surgery
    • /
    • v.4 no.1
    • /
    • pp.13-16
    • /
    • 2017
  • Fibular free flap reconstruction is the flap of the choice in long-span mandibular bone reconstruction. The most common disadvantage of the fibular flap is short bone height to install dental implant. Double barrel fibular flap has been tried, however, bulky flap in the oral cavity hinder its use. Titanium reconstruction plate has been used simultaneously with the free fibular flap to stabilize occlusion and to fix the fibular flap. In this study, titanium reconstruction plate was fixed in the lower border of the mandible and the fibular free flap was fixed in the superior border of the titanium plate to improve implant-crown ratio. This new technique improved the longevity of the dental prosthodontics with dental implants.

ROENTGENOLOGIC INVESTIGATIONS FOR THE ANTERIOR TOOTH LENGTH (전치장경에 관한 X-선학적 연구)

  • Cho Won Pyo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.2 no.1
    • /
    • pp.53-57
    • /
    • 1972
  • The author measured the length of crown, root and tooth on the films which was taken by intraoral bisecting technic with mesh plate on the films. The films were taken from the dry skulls, dentiform and patients who had to be removed their upper incisors and the other patients who adimitted for dental care. From this serial experiment the results was made as follows: 1. By using the film and mesh plate in the oral cavity, the real tooth length can be measured easily on the film surfaces. 2. It can be avoided the film distortion in the oral cavity when taking the film using the mesh plate and film together. 3. When measuring the film, length of crown was elongated and length of root was shortened. 4. When using the well-trained bisecting technic, the real tooth length can be measured directly on the intraoral film.

  • PDF

A novel retentive type of dental implant prosthesis: marginal fitness of the cementless double crown type implant prosthesis evaluated by bacterial penetration and viability

  • Hong, Seoung-Jin;Kwon, Kung-Rock;Jang, Eun-Young;Moon, Ji-Hoi
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.233-238
    • /
    • 2020
  • PURPOSE. This study aims to compare the marginal fitness of two types of implant-supported fixed dental prosthesis, i.e., cementless fixation (CL.F) system and cement-retained type. MATERIALS AND METHODS. In each group, ten specimens were assessed. Each specimen comprised implant lab analog, titanium abutment fabricated with a 2-degree tapered axial wall, and zirconia crown. The crown of the CL.F system was retained by frictional force between abutment and relined composite resin. In the cement-retained type, zinc oxide eugenol cement was used to set crown and abutment. All specimens were sterilized with ethylene oxide, immersed in Prevotella intermedia culture in a 50 mL tube, and incubated with rotation. After 48 h, the specimens were washed thoroughly before separating the crown and abutment. The bacteria that penetrated into the crown-abutment interface were collected by washing with 500 µL of sterile saline. The bacterial cell number was quantified using the agar plate count technique. The BacTiter-Glo Microbial Cell Viability Assay Kit was used to measure bacterial adenosine triphosphate (ATP)-bioluminescence, which reflects the bacterial viability. The t-test was performed, and the significance level was set at 5%. RESULTS. The number of penetrating bacterial cells assessed by colony-forming units was approximately 33% lower in the CL.F system than in the cement-retained type (P<.05). ATP-bioluminescence was approximately 41% lower in the CL.F system than in the cement-retained type (P<.05). CONCLUSION. The CL.F system is more resistant to bacterial penetration into the abutment-crown interface than the cement-retained type, thereby indicating a precise marginal fit.

Roll deformation and wear analysis of backup roll in heavy plate mill (후판압연의 백업롤 변형해석 및 마모특성 분석)

  • Seo, Jae-Hyung;Gho, Sung-Hyun;Moon, Chang-Ho;Chun, Myung-Sik;Park, Hae-Doo
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.04a
    • /
    • pp.62-64
    • /
    • 2009
  • Control of back-up roll deformation and wear profile in plate rolling is important not only for enhancement of the structural precision of mill, but also for improving the yield and rolling operation. in the heavy plate mill, there have been strong demands for upgrading back up roll operation technology. In order to satisfy these demands, it is essential to develop the backup roll deformation analysis models and wear profile prediction models. This paper gives a general description of the backup roll deformation and wear model, simulation result for deformation analysis and wear profile.

  • PDF

Anchor Plate Efficiency in Postoperative Orthodontic Treatment Following Orthognathic Surgery via Minimal Presurgical Orthodontic Treatment

  • Jeong, Tae-Min;Kim, Yoon-Ho;Song, Seung-Il
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.4
    • /
    • pp.154-160
    • /
    • 2014
  • Purpose: The efficiency of an anchor plate placed during orthognathic surgery via minimal presurgical orthodontic treatment was evaluated by analyzing the mandibular relapse rate and dental changes. Methods: The subjects included nine patients with Class III malocclusion who had bilateral sagittal split osteotomy at the Division of Oral and Maxillofacial Surgery, Department of Dentistry in Ajou University Hospital, after minimal presurgical orthodontic treatment. During orthognathic surgery, anchor plates were placed at both maxillary buttresses. The anchor plates were used to move maxillary teeth backward and for maximum anchorage of Class III elastics to minimize mandibular relapse during the postoperative orthodontic treatment. The lateral cephalometric X-ray was taken preoperatively (T0), postoperatively (T1), and one year after the surgery (T2). Seven measurements (distance from Pogonion to line Nasion-Nasion perpendicular [Pog-N Per.], angle of line B point-Nasion and Nasion-Sella [SNB], angle of line maxilla 1 root-maxilla 1 crown and Nasion-Sella [U1 to SN], distance from maxilla 1 crown to line A point-Nasion [U1 to NA], overbite, overjet, and interincisal angle) were taken. Measurements at T0 to T1 and T1 to T2 were compared and differences tested by standard statistical methods. Results: The mean skeletal change was posterior movement by $13.87{\pm}4.95mm$ based on pogonion from T0 to T1, and anterior movement by $1.54{\pm}2.18mm$ from T1 to T2, showing relapse of about 10.2%. There were significant changes from T0 to T1 for both Pog-N Per. and SNB (P<0.05). However, there were no statistically significant changes from T1 to T2 for both Pog-N Per. and SNB. U1 to NA that represents the anterior-posterior changes of maxillary incisor did not differ from T0 to T1, yet there was a significant change from T1 to T2 (P<0.05). Conclusion: This study found that the anchor plate minimizes mandibular relapse and moves the maxillary teeth backward during the postoperative orthodontic treatment. Thus, we conclude that the anchor plate is clinically very useful.

Interdisciplinary rehabilitation of a root-fractured maxillary central incisor: A 12-year follow-up case report

  • Bonetti, Giulio Alessandri;Parenti, Serena Incerti;Ciocci, Maurizio;Checchi, Luigi
    • The korean journal of orthodontics
    • /
    • v.44 no.4
    • /
    • pp.217-225
    • /
    • 2014
  • Single-tooth implantation has become a common treatment solution for replacement of a root-fractured maxillary incisor in adults, but the long-term esthetic results can be unfavorable due to progressive marginal bone loss, resulting in gingival recession. In this case report, a maxillary central incisor with a root fracture in its apical one-third was orthodontically extruded and extracted in a 21-year-old female. Implant surgery was performed after a 3-month healing period, and the final crown was placed about 12 months after extraction. After 12 years, favorable osseous and gingival architectures were visible with adequate bone height and thickness at the buccal cortical plate, and no gingival recession was seen around the implant-supported crown. Although modern dentistry has been shifting toward simplified, clinical procedures and shorter treatment times, both general dentists and orthodontists should be aware of the possible long-term esthetic advantages of orthodontic extrusion of hopelessly fractured teeth for highly esthetically demanding areas and should educate and motivate patients regarding the choice of this treatment solution, if necessary.

Correlation analysis of periodontal tissue dimensions in the esthetic zone using a non-invasive digital method

  • Kim, Yun-Jeong;Park, Ji-Man;Cho, Hyun-Jae;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.2
    • /
    • pp.88-99
    • /
    • 2021
  • Purpose: Direct intraoral scanning and superimposing methods have recently been applied to measure the dimensions of periodontal tissues. The aim of this study was to analyze various correlations between labial gingival thickness and underlying alveolar bone thickness, as well as clinical parameters among 3 tooth types (central incisors, lateral incisors, and canines) using a digital method. Methods: In 20 periodontally healthy subjects, cone-beam computed tomography images and intraoral scanned files were obtained. Measurements of labial alveolar bone and gingival thickness at the central incisors, lateral incisors, and canines were performed at points 0-5 mm from the alveolar crest on the superimposed images. Clinical parameters including the crown width/crown length ratio, keratinized gingival width, gingival scallop, and transparency of the periodontal probe through the gingival sulcus were examined. Results: Gingival thickness at the alveolar crest level was positively correlated with the thickness of the alveolar bone plate (P<0.05). The central incisors revealed a strong correlation between labial alveolar bone thickness at 1 and 2 mm, respectively, inferior to the alveolar crest and the thickness of the gingiva at the alveolar crest line (G0), whereas G0 and labial bone thickness at every level were positively correlated in the lateral incisors and canines. No significant correlations were found between clinical parameters and hard or soft tissue thickness. Conclusions: Gingival thickness at the alveolar crest level revealed a positive correlation with labial alveolar bone thickness, although this correlation at identical depth levels was not significant. Gingival thickness, at or under the alveolar crest level, was not associated with the clinical parameters of the gingival features, such as the crown form, gingival scallop, or keratinized gingival width.

Prosthetic treatment for patient with congenital bilateral cleft lip and palate to close oro-nasal communication using maxillary double crown and clasp retained removable denture (선천성 양측성 구순구개열 환자의 구비강 연결 폐쇄를 위한 상악 이중관과 고리 유지형 국소의치를 이용한 수복 증례)

  • Doh, Seok-Joo;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.18-23
    • /
    • 2019
  • Patients with cleft lip and palate have several problems such as oro-nasal communication, dental cross-bite caused by the insufficient growth of maxilla, poor pronunciation and esthetic problem. Removable denture with maxillary double crown near cleft palate and with clasp in the posterior teeth was used to solve the problems of the patient with cleft lip and plate. Double crowns make up for the insufficient mucosal support caused by the mucosa and alveolar bone loss in cleft lip and palate. Double crowns also allow easy repair of denture in case of abutment teeth extraction. In this case, 55-year-old female patient had bilateral cleft lip and palate and few remaining teeth on anterior maxilla. Prosthetic treatment was done for patient with bilateral cleft lip and palate to close oro-nasal communication using maxillary double crown and clasp retained removable denture. As a result, oro-nasal communication was effectively closed and the cross-bite was easily corrected by double crown and clasp retained denture. In addition, pronunciation and appearance were also improved.

New Design for Jacket-type Offshore Wind Turbine Support Structure for Southwest Coast of South Korea

  • Choi, Byeong-Ryoel;Jo, Hyo-Jae;Choi, Han-Sik;Ha, Sung-Yeol;Park, Young-Ho
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.3 no.4
    • /
    • pp.184-192
    • /
    • 2017
  • The Korea Offshore Wind Power (KWOP) cooperation is planning to construct offshore wind energy farms with an overall rated power of 2.5 GW along the southwestern coast by 2019. Hitherto, various structural types of support structures for offshore wind turbines have been being proposed, but these structures have lacked economic analysis studies. Therefore, their economical superiority to existing types has been difficult to guarantee. An offshore structure with economic efficiency will have a minimum amount of mobilizing equipment and short offshore construction period because of the application of rapid installation methods. Thus, the development of a new support structure with economic efficiency is generally considered to be necessary. Accordingly, this paper proposes a newly developed and more economical jacket type for the offshore support structure. This study confirmed its structural safety and performance by conducting a structural analysis and eigenvalue analysis. The manufacturing and installation costs were then estimated. As a result, the new jacket type of offshore support structure proposed in this study significantly reduced the manufacturing and installation costs. Therefore, it is expected that the proposed jacket will contribute to reducing construction expenses for new wind power farms and invigorating wind power farm businesses.

Load transfer mechanism due to tunnel excavation in the jointed sandy ground (불연속면을 포함한 사질토 지반에서 터널 굴착에 따른 하중전이)

  • Lee, Sang-Duk;Kim, Yang-Woon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.3
    • /
    • pp.217-226
    • /
    • 2003
  • This study is focused on the finding out load transfer mechanism in the ground near the tunnel during tunnel excavation in the jointed sandy ground. Laboratory model tests were performed on various cases of the overburden heights above tunnel crown, location, and degree of discontinuity planes. For model tests, a movable plate was installed in the midst of the bottom of sandy ground. This plate, moving downwards, was intended to model the stress relaxation during tunnel excavation. The load transfer was measured at the fixed separated bottom plates adjacent to the movable plate. As the result, the loosening zone and the load-transfer form around the tunnelling site were affected by the overburden height and the characteristics of discontinuous planes. And large loosening zone was developed along the discontinuous planes which were close to the tunnel.

  • PDF