• 제목/요약/키워드: Plate and screw

검색결과 182건 처리시간 0.02초

Load Sharing Mechanism Across Graft-Bone Interface in Static Cervical Locking Plate Fixation

  • Han, In-Ho;Kuh, Sung-Uk;Chin, Dong-Kyu;Jin, Byung-Ho;Cho, Yang-Eun;Kim, Keun-Su
    • Journal of Korean Neurosurgical Society
    • /
    • 제45권4호
    • /
    • pp.213-218
    • /
    • 2009
  • Objective : This study is a retrospective clinical study over more than 4 years of follow up to understand the mechanism of load sharing across the graft-bone interface in the static locking plate (SLP) fixation compared with non-locking plate (NLP). Methods : Orion locking plates and Top non-locking plates were used for SLP fixation in 29 patients and NLP fixation in 24 patients, respectively. Successful interbody fusion was estimated by dynamic X-ray films. The checking parameters were as follows : screw angle (SA) between upper and lower screw, anterior and posterior height of fusion segment between upper and lower endplate (AH & PH), and upper and lower distance from vertebral endplate to the end of plate (UD & LD). Each follow-up value of AH and PH were compared to initial values. Contributions of upper and lower collapse to whole segment collapse were estimated. Results : Successful intervertebral bone fusion rate was 100% in the SLP group and 92% in the NLP group. The follow-up mean value of SA in SLP group was not significantly changed compared with initial value, but follow-up mean value of SA in NLP group decreased more than those in SLP group (p=0.0067). Statistical analysis did not show a significant difference in the change in AH and PH between SLP and NLP groups (p>0.05). Follow-up AH of NLP group showed more collapse than PH of same group (p=0.04). The upper portion of the vertebral body collapsed more than the lower portion in the SLP fixation (p=0.00058). Conclusion : The fused segments with SLP had successful bone fusion without change in initial screw angle, which was not observed in NLP fixation. It suggests that there was enough load sharing across bone-graft interface in SLP fixation.

경추용 일체형 추간체 유합 보형재의 디자인 변화에 따른 생체역학적 효과 비교 연구 (Comparative Study on Biomechanical Behavior of Various Cervical Stand-Alone Cage Designs)

  • 박광민;정태곤;정승조;이성재
    • 한국정밀공학회지
    • /
    • 제33권11호
    • /
    • pp.943-950
    • /
    • 2016
  • The purpose of this study was to evaluate and compare by finite element analysis the biomechanical performance, in terms of cervical stand-alone cage screw insert angle (Type 3 - 5: 2 Screws) and screw arrangement (Type 6 and 7: 3 Screws / Type 8 and 9: 4 Screws), and the range of motion (ROM) of traditional anterior cervical discectomy of a fusion device (Type 1: Cage / Type 2: Cage + ACP). Our study suggests that the biomechanical behavior of a postoperative cervical spine could indeed be influenced by design features, such as screw angle and number of screws. In particular, ROM and the risk of subsidence were more sensitive during extension about type 5 (Insert Angle $20^{\circ}$). Our study also suggested that the number of screw asymmetries between up and down for type 6 and 7 could result in differences in the risk of screw fracture manifesting in different clinical aspects.

전방 잠금형 금속판을 이용한 요골 원위부 골절수술 후 요골구 접선방향 촬영법의 임상적 유용성 (The Clinical usefulness of the tangential projection view of Radius groove after Distal Radius Fracture operation using the T-type Plat)

  • 서선열;조정희;한만석;김태형;유세종;김용균;한동균
    • 한국산학기술학회논문지
    • /
    • 제14권6호
    • /
    • pp.2760-2766
    • /
    • 2013
  • 서론 : 본 논문은 전방 잠금형 금속판을 이용한 요골 원위부 골절 수술 후 나사못(screw)의 요골구 관통 유무를 확인하기 위한 방법으로 방사선 요골구 접선방향촬영법의 새로운 검사법을 제시하고자 한다. 재료 및 방법 : 요골구 접선방향 촬영 시 요골 원위부 거상 각도는 2.5, 5, 7.5, 10도와 전완골과 방사선 검출기와의 각도를 60, 70, 80도로 각각 변화시켜 촬영한 방사선영상에서 나사못의 요골구 관통유무를 분석하였다. 결과 : 요골구 접선방향 영상에서는 요골구를 관통하지 않은 경우와 요골구 내관통, 요골구 외관통인 경우가 각각 55명(63.95%), 9명(10.47%), 22명(25.58%)으로 분석 되었고, 요골구를 관통한 나사못의 길이는 0.43~2.72mm의 범위로 평균 1.06mm이었다. 요골구가 잘 묘사되는 방사선 촬영법은 요골 거상각도 2.5~7.5도에서 90%이상, 전완골과 방사선 검출기의 각도 70도에서 요골구가 80%이상 잘 묘사되는 것으로 분석 되었다. 결론 : 요골구 접선방향 촬영법은 요골 원위부 거상 각도 5도, 전완골과 검출기의 각도는 70도를 추천 한다.

무지외반증 환자의 근위 갈매기형 절골술에서 생체 흡수성 나사못을 이용한 고정 (Bioabsorbable Screws Used in Hallux Valgus Treatment Using Proximal Chevron Osteotomy)

  • 신우진;정영우;안기용;서재웅
    • 대한족부족관절학회지
    • /
    • 제22권4호
    • /
    • pp.181-183
    • /
    • 2018
  • Hallux valgus is a deformity that causes pain in the first metatarsophalangeal joint. Surgical methods are quite diverse and a range of osteotomies are used at the proximal and distal part of the metatarsal bone and proximal phalange. Fixation methods, such as plate, screw, K-wire, and others have been used in various ways. The fixation device is often removed with various side effects due to the fixation devices. In the case of instruments that are absorbed in vivo, these procedures are not necessary to remove and there is an advantage of not performing the second operation. Three patients were treated, in which a proximal chevron osteotomy was used with a bioabsorbable screw (K-$MET^{TM}$; U&I Corporation).

한국인의 종골 크기 (The Size of Calcaneus in Koreans)

  • 김진수;조훈기;황새민;이근우;양기원;이경태
    • 대한족부족관절학회지
    • /
    • 제17권2호
    • /
    • pp.143-149
    • /
    • 2013
  • Purpose: Open reduction and internal fixation of calcaneal fracture using plate has been used. While numerous plates have been manufactured, most of the conventional plates are designed for westerners, realistically the size is larger for Korean. The domestic products, on the other hand, often have the undesirable screw holes and path. Therefore, we measured the radiologic parameter of Korean calcaneus for providing the plate and screw hole placements. Materials and Methods: We measured the outer lines and angles with over the 20 years old 291 females and 322 males. A: Length of inferior plane of calcaneus, B: Length of anterior plane of calcaneus, C: Length from line A to sinus tarsi, D: Length from line A to posterior point of posterior facet, E: Length from line A to calcaneal tuberosity, F: Length of posterior facet, G: Length from anterior point of line A to C, H: Length from line C to line D, a: Angle between A and B, b: Gissane angle, c: Bohler angle, d: Calcaneal pitch angle using Marosis m-view$^{(R)}$. Results: Mean A, B, C, D, E, F, G, H were 63.6, 26.4, 23.2, 43.7, 40.5, 26.9, 12.8, 18.1 mm. Mean a, b, c, d angle were 105.8, 122.4, 32.4, $20.5^{\circ}$. Male's calcaneus is significantly bigger than female's (p<0.001). Conclusion: AP calcaneus length 63.6 mm, maximal height 43.7 mm is considered to be helpful in making the Korean calcaneal plate.

Risk Factors for Delayed Hinge Fracture after Plate-Augmented Cervical Open-Door Laminoplasty

  • Hur, Junseok W.;Park, Youn-Kwan;Kim, Bum-Joon;Moon, Hong-Joo;Kim, Joo-Han
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권4호
    • /
    • pp.368-373
    • /
    • 2016
  • Objective : Delayed hinge fracture (HF) that develops after cervical open door laminoplasty can be a source of postoperative complications such as axial pain. However, risk factors related to this complication remain unclear. We performed a retrospective clinical series to determine risk factors for delayed HF following plate-only open-door cervical laminoplasty. Methods : Patients who underwent plate-only open-door laminoplasty and had available postoperative computed tomography (CT) scans (80 patients with 270 laminae) were enrolled. Hinge status, hinge gutter location, open location, hinge width, number of screws used, operation level, and open angle were observed in the CT to determine radiographic outcome. Demographic data were collected as well. Radiographic and clinical parameters were analyzed using univariate and multivariate logistic regression analysis to determine the risk factors for HF. Results : Univariate logistic regression analysis results indicated poor initial hinge status, medially placed hinge gutter, double screw fixation on the elevated lamina, upper surgical level, and wide open angle as predictors for HF (p<0.05). Initial hinge status seemed to be the most powerful risk factor for HF (p=0.000) and thus was collinear with other variables. Therefore, multivariate logistic regression analysis was performed excluding initial hinge status, and the results indicated that medially placed hinge gutter, double screw fixation on the elevated lamina, and upper surgical level were risk factors for HF after adjustment for other confounding factors. Conclusion : To prevent HF and to draw a successful postoperative outcome after cervical laminoplasty, surgical and clinical precautions should be considered.

흡수성 고정판이 가토의 악골골절 치유에 미치는 영향 (THE EFFECTS OF RESORBABLE PLATE IN THE HEALING PROCESS OF MANDIBULAR FRACTURE OF THE RABBITS)

  • 박현욱;류동목;이한주;허원실
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제21권2호
    • /
    • pp.131-138
    • /
    • 1999
  • The purpose of this study is to evaluate the effects of resorbable plate in the healing process of mandibular fracture. Reduction and rigid fixation was carried out on the artificial mandibular fracture site of the rabbits, using a resorbable screw, 1.5mm in diameter and 4.0mm in length, and an absorbable plate 1.5mm in thickness(Lactosorb$^{(R)}$). En block tissue specimens with plate were taken from the rabbits at 4, 6, 8, and 10 weeks intervals and specimen were observed with light microscope under the hematoxylin-eosin staining, to observe the inflammatory reaction and tissue healing process. The following conclusions were drawn: 1. The subject displayed good healing with no signs of detachment of the fixation plate. 2. At 4 weeks, the plate was covered by the connective tissue. Then at 6 weeks, bone regeneration was discovered around the plate. 3. During the period of healing, no inflammatory reaction or foreign body reaction, as a result of using resorbable plate, were observed. 4. At 8 weeks, the initial phase of the absorption of the plate was observed. Then at 10 weeks, macrophage were observed around the plate, indicating the absorption phase was in process. From the above results, it can be determined that when the resorbable plate is applied to rabbit, full recuperation occurs naturally in the absence of inflammatory reaction and foreign body reaction. The selected study is clinically valuable in proving this procedure.

  • PDF

볼나사일체형 LM가이드 설계에 관한 연구 (Case Study on the Safety Working Load of a LM-Guide Structure)

  • 윤영식;신동우
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.820-825
    • /
    • 2007
  • A ballscrew-linear motion(LM) guide is well-described by its name: it is a LM guide that runs by ballscrew. It consists of LM rail, LM block, end plate, screw, nut and bearing balls. The ballscrew-LM guide has many advantages compared with conventional LM guide. The high efficiency achieved with rolling contact devices permits the employment of antibacklash methods. The balls provide the only physical contact between nut rail and block and ball screw and nut replacing the sliding friction with a rolling motion. The life of the ballscrew-LM is determinated by the balls. The objective of this paper is to introduce the design of the ballscrew-LM with the safety working load.

  • PDF

Danis-Weber B형 족관절 외과 골절의 고정방법 비교연구 : Antiglide 금속판 고정술 대 외측 금속판 고정술 (Comparative Study for the Fixation Method in the Danis-Weber Type B Lateral Malleolar Fractures: An Antiglide Plate Fixation versus A Lateral Plate Fixation)

  • 신헌규;최재열;강동호
    • 대한족부족관절학회지
    • /
    • 제10권2호
    • /
    • pp.201-206
    • /
    • 2006
  • Purpose: To evaluate the advantages of the antiglide plate fixation procedure for Danis-Weber type B lateral malleolar fractures of ankle compared to other methods of lateral plate fixation. Materials and Methods: We reviewed 70 cases that antiglide plate fixation and lateral plate fixation procedures were performed from Mar. 2001 through Mar. 2006. Of the total 70 cases, they were divided into two groups ; 22 cases were treated with the antiglide plate procedure (Group I) and 48 cases were treated with the lateral plate procedure (Group II). The results of the two groups were analyzed both radiographically and clinically using Ankle-Hindfoot scale of the American Orthopedic Foot and Ankle Society (AOFAS). Results: All fractures were healed at average of 8 weeks both radiographically and clinically. According to the Ankle-Hindfoot scale, all cases of Group I and 48 cases of Group II were above 80 points. 2 cases (9%) in Group I complained of peroneal tendinitis, while 19 cases (39%) in Group II showed skin irritation resulting from the screw or the plate. A total of 6 cases (27%) in Group I and 27 cases (55%) in Group II complained cosmetic problems. Conclusion: we concluded that the antiglide plate fixation for Danis-Weber type B lateral malleolar fractures is one of the good methods. But, further analysis will be need to find a solution for the peroneal tendinitis.

  • PDF

하악각 골절의 치료 방법에 따른 하악골의 응력 분포 및 변위에 관한 삼차원 유한요소법적 연구 (THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND DISPLACEMENT IN MANDIBLE ACCORDING TO TREATMENT MODALITIES OF MANDIBULAR ANGLE FRACTURES)

  • 구제훈;김일규;장재원;양정은;사시카라 바라라만;왕붕
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권3호
    • /
    • pp.207-217
    • /
    • 2010
  • The purpose of this study was to evaluate the effects of the stress distribution and displacement in mandible according to treatment modalities of mandibular angle fractures, using a three dimensional finite element analysis. A mechanical model of an edentulous mandible was generated from 3D scan. A 100-N axial load and four masticatory muscular supporting system were applied to this model. According to the number, location and materials of titanium and biodegradable polymer plates, the experimental groups were divided into five types. Type I had a single titanium plate in the superior border of mandibular angle, type II had two titanium plates in the superior tension border and in the inferior compression border of mandibular angle, type III had a single titanium plate in the ventral area of mandibular angle, type IV had a single biodegradable polymer plate in the superior border of mandibular angle, type V had a single biodegradable polymer plate in the ventral area of mandibular angle. The results obtained from this study were follows: 1. Stress was concentrated on the condylar neck of the fractured side except Type III. 2. The values of von-Mises stress of the screws were the highest in the just-posterior screw of the fracture line, and in the just-anterior screw of Type III. 3. The displacement of mandible in Type III was 0.04 mm, and in Type I, II, IV, and V were 0.10 mm. 4. The plates were the most stable in the ventral area of mandibular angle (Type III, V). In conclusion, the ventral area of mandibular angle is the most stable location in the fixation of mandibular angle fractures, and the just- posterior and/or the just-anterior screws of the fracture line must be longer than the other, and surgeons have to fix accurately these screws, and the biodegradable polymer plate also was suitable for the treatment of mandible angle fracture.