• Title/Summary/Keyword: Plate Work

Search Result 936, Processing Time 0.038 seconds

Development of Visible-light Responsive $TiO_2$ Thin Film Photocatalysts by Magnetron Sputtering Method and Their Applications as Green Chemistry Materials

  • Matsuoka, Masaya
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.3.1-3.1
    • /
    • 2010
  • Water splitting reaction using photocatalysts is of great interest in the utilization of solar energy [1]. In the present work, visible light-responsive $TiO_2$ thin films (Vis-$TiO_2$) were prepared by a radio frequency magnetron sputtering (RF-MS) deposition method and applied for the separate evolution of $H_2$ and $O_2$ from water as well as the photofuel cell. Special attentions will be focused on the effect of HF treatment of Vis-$TiO_2$ thin films on their photocatalytic activities. Vis-$TiO_2$ thin films were prepared by an RF-MS method using a calcined $TiO_2$ plate and Ar as the sputtering gas. The Vis-$TiO_2$ thin films were then deposited on the Ti foil substrate with the substrate temperature at 873 K (Vis-$TiO_2$/Ti). Vis-$TiO_2$/Ti thin films were immersed in a 0.045 vol% HF solution at room temperature. The effect of HF treatments on the activity of Vis-$TiO_2$/Ti thin films for the photocatalytic water splitting reaction have been investigated. Vis-$TiO_2$/Ti thin films treated with HF solution (HF-Vis-$TiO_2$/Ti) exhibited remarkable enhancement in the photocatalytic activity for $H_2$ evolution from a methanol aqueous solution as well as in the photoelectrochemical performance under visible light irradiation as compared with the untreated Vis-$TiO_2$/Ti thin films. Moreover, Pt-loaded HF-Vis-$TiO_2$/Ti thin films act as efficient and stable photocatalysts for the separate evolution of $H_2$ and $O_2$ from water under visible light irradiation in the presence of chemical bias. Thus, HF treatment was found to be an effective way to improve the photocatalytic activity of Vis-$TiO_2$/Ti thin films. Furthermore, unique separate type photofuel cell was fabricated using a Vis-$TiO_2$ thin film as an electrode, which can generate electrical power under solar light irradiation by using various kinds of biomass derivatives as fuel. It was found that the introduction of an iodine ($I^-/{I_3}^-$) redox solution at the cathode side enables the development of a highly efficient photofuel cell which can utilize a cost-efficient carbon electrode as an alternative to the Pt cathode.

  • PDF

Fabrication and characterization of 3-D porous scaffold by polycaprolactone (폴리카프로락톤을 이용한 3차원 다공성 지지체 제조 및 특성 분석)

  • Kim, Jin-Tae;Bang, Jung Wan;Hyun, Chang-Yong;Choi, Hyo Jeong;Kim, Tae-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.58-65
    • /
    • 2016
  • This study was a preparatory experiment aimed the development of membrane scaffolds for tissue engineering. A PCL composite solution contained sodium chloride(NaCl). PCL porous membrane scaffolds were formed on a glass casting plate using a film applicator and immersed in distilled water to remove the NaCl reaching after drying. NaCl was used as a pore former for a 3 dimensional pore net-work. The dry condition parameters were $4^{\circ}C$, room temperature (RT) and $40^{\circ}C$ for each different temperatures in the drying experiment. SEM revealed the morphology of the pores in the membrane after drying and evaluated the in vitro cytotoxicity for basic bio-compatibility. The macro and micro pores existed together in the scaffold and showed a 3-dimensional pore net-working morphology at RT. The in vitro cytotoxicity test result was "grade 2" in accordance with the criterion for cytotoxicity by ISO 10993-5. The dry condition affected the formation of a 3 dimensional pore network and micro and macro pores. Therefore, these results are expected provide the basic process for the development of porous membrane scaffolds to control degradation and allow drug delivery.

A Study on Perceptions by College Students of Radiology about the Knowledge, Attitudes and Behaviors of Radiation Exposure Management (방사선과 대학생이 방사선피폭관리에 대한 지식, 태도, 행위에 관한 연구)

  • Yeo, Jindong;Ko, Inho;Kim, Hye-Sook
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.2
    • /
    • pp.79-99
    • /
    • 2015
  • Participants of this study were students of radiology who were attending colleges or universities located in Daegu and Gyeongbuk. This researcher conducted a questionnaire survey of those students from Feb. 3rd to 21st, 2014. The findings of the study can be summarized as follows. 1. Concerning the knowledge of radiation exposure management, the respondents' scores were highest in two items, or 'Materials based on lead or concrete may shield X-rays' and 'The sexual gland is very sensitive to radiation' and lowest in the item which says' 'Occupational radiation exposure dose should not exceed 20mSv a year in average on a 5-year period basis'. 2. The participants' scores for the attitudes of radiation exposure management were higher in two items, or 'Health examination should be made regularly in relation to radiation exposure' and 'Those who work within the area of irradiation should wear protective clothes' and lowest in the item which says 'Radiation exposure dose should be regularly measured for the calibration of the radiation system'. 3. For the behaviors of radiation exposure management, the surveyed students showed highest scores in two items, or 'When irradiating the patient, the radiator should be behind the protective barrier(plate)' and 'It is needed to receive the education of radiation exposure management regularly' While, their score for a behavior described in the item saying 'Before using the radiation system, it is needed to check whether the machine works normally.

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

Development of liquid target for beam-target neutron source & two-channel prototype ITER vacuum ultraviolet spectrometer

  • Ahn, B.N.;Lee, Y.M.;Dang, J.J.;Hwang, Y.S.;Seon, C.R.;Lee, H.G.;Biel, W.;Barnsley, R.;Kim, D.E.;Kim, J.G.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.421-422
    • /
    • 2011
  • The first part is about development of a liquid target for a neutron source, which is designed to overcome many of the limitations of traditional beam-target neutron generators by utilizing a liquid target neutron source. One of the most critical aspects of the beam-target neutron generator is the target integrity under the beam exposure. A liquid target can be a good solution to overcome damage to the target such as target erosion and depletion of hydrogen isotopes in the active layer, especially for the one operating at high neutron fluxes with no need for water cooling. There is no inherent target lifetime for the liquid target neutron generator when used with continuous refreshment of the target surface exposed to the energetic beam. In this work, liquid target containing hydrogen has been developed and tested in vacuum environment. Potentially, liquid targets could allow a point neutron source whose spatial extension is on the order of 1 to $10{\mu}m$. And the second is about the vacuum ultraviolet (VUV) spectrometer which is designed as a five-channel spectral system for ITER main plasma measurement. To develop and verify the design, a two-channel prototype system was fabricated with No. 3 (14.4 nm~31.8 nm) and No. 4 (29.0 nm~60.0 nm) among the five channels. For test of the prototype system, a hollow cathode lamp is used as a light source. The system is composed of a collimating mirror to collect the light from source to slit, and two holographic diffraction gratings with toroidal geometry to diffract and also to collimate the light from the common slit to detectors. The two gratings are positioned at different optical distances and heights as designed. To study the appropriate detector for ITER VUV system, two different electronic detectors of the back-illuminated charge coupled device and the micro-channel plate electron multiplier were installed and the performance has been investigated and compared in the same experimental conditions. The overall system performance was verified by measuring the spectrums.

  • PDF

Evaluation of the Level of microbial Contamination in the Processing Company of Nuroong-ji (누룽지 생산시설에 대한 미생물학적 오염도 평가)

  • Do, Yu-No;Choi, Jeong-Sik;Jung, Yu-Kyung;Park, Ji-Hyun;Roh, Kyong-Hwan;Kim, Sung-Soo;Choi, Shin-Young;Lee, Kyoung-Yun;Han, Eui-Jeong
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.4
    • /
    • pp.333-340
    • /
    • 2010
  • This study was conducted to evaluate the microbial contamination levels in the processing company of Nuroong-ji. Microbial contamination levels were examined for sanitary indication bacteria such as aerobic plate count, coliforms and fungi, and pathogenic bacteria such as Escherchia coli O157:H7, Salmonella spp., Staphylococcus aureus, and Listeria monocytogenes. Contamination levels were detected differently according to handling materials and purposing work-space. The equipments and raw materials were not seriously contaminated but there were necessary to attend the cross-contamination. A high contamination level was detected at the process where the interference of the employees was relatively higher than the other process. Standardization of the roasting process (l20~$170^{\circ}C$, about 10 min) could be necessary to control the microbial organism effectively on Nuroong-ji manufacturing process. At small/medium size foodstuff manufacturers, it is the most important to improve the recognition level of individual hygiene but also expand a hygiene facility.

Improvement of Thermal Stability of Optical Current Sensors Based on Polymeric Optical Integrated Circuits for Quadrature Phase Interferometry (사분파장 위상 간섭계 폴리머 광집적회로 기반 광전류센서의 온도 안정성 향상 연구)

  • Chun, Kwon-Wook;Kim, Sung-Moon;Park, Tae-Hyun;Lee, Eun-Su;Oh, Min-Cheol
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.6
    • /
    • pp.249-254
    • /
    • 2019
  • An optical current sensor device that measures electric current by the principle of the Faraday effect was designed and fabricated. The polarization-rotated reflection interferometer and the quadrature phase interferometer were introduced so as to improve the operational stability. Complex structures containing diverse optical components were integrated in a polymeric optical integrated circuit and manufactured in a small size. This structure allows sensing operation without extra bias feedback control, and reduces the phase change due to environmental temperature changes and vibration. However, the Verdet constant, which determines the Faraday effect, still exhibits an inherent temperature dependence. In this work, we tried to eliminate the residual temperature dependence of the optical current sensor based on polarization-rotated reflection interferometry. By varying the length of the fiber-optic wave plate, which is one of the optical components of the interferometer, we could compensate for the temperature dependence of the Verdet constant. The proposed optical current sensor exhibited measurement errors maintained within 0.2% over a temperature range, from 25℃ to 85℃.

Antibacterial Effects of Lactococcus lactis HK-9 Isolated from Feces of a New Born Infant (신생아 태변에서 젖산세균인 Lactococcus lactis HK-9의 분리 및 항균활성)

  • Baek, Hyun;Ahn, Hye-Ran;Cho, Yun-Seok;Oh, Kye-Heon
    • Korean Journal of Microbiology
    • /
    • v.46 no.2
    • /
    • pp.127-133
    • /
    • 2010
  • The purpose of this work was to investigate the antibacterial activity derived from a lactic acid bacterium, Lactococcus lactis HK-9, isolated from the feces of a 2-day newborn infant. We characterized the physiological and biochemical properties of this strain. Both the BIOLOG system and phylogenetic analysis using 16S rRNA sequencing were utilized for identification, and the strain was assigned to the Lactococcus lactis species, designated as L. lactis HK-9, and registered in GenBank as [GU936712]. We monitored growth rate, production of lactic acid and acetic acid as metabolites, and pH during growth. The maximum concentrations of lactic acid and acetic acid reached 495.6 mM and 104.3 mM, respectively, and the initial pH of the cultures decreased from 7.0 to 4.1 after incubating for 60 h. HPLC was used to confirm the production of lactic acid and acetic acid. Significant antibacterial activity of the concentrated supernatant was demonstrated against Gram-positive (e.g., Staphylococcus aureus, Enterococcus faecalis, Listeria monocytogenes, MRSA) and Gram-negative (e.g., Escherichia coli, Salmonella enteritidis, Pseudomonas aeruginosa, Klebsiella pneumoniae, Shigella sonnei) bacteria by the plate diffusion method. The antibacterial activity was sensitive to protease, and the molecular weight of the presumed bacteriocin molecule was estimated to be about 4 kDa by tricine-SDS-PAGE.

An Experimental Study on the Augmentation of Heat Transfer by Impinging Air Jets with Swirl (충돌선회분류(衝突旋回噴流) 열전달증진(熱傳達增進)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Ohu, Su-Cheol;Park, Sung-Soo
    • Solar Energy
    • /
    • v.13 no.1
    • /
    • pp.22-30
    • /
    • 1993
  • This Paper deals with the experimental study of the axisymmetric air jet impinging vertically on the flat heating surface with and without swirl. The purpose of this study is to investigate the characteristics of flow, augmentation of heat transfer rate, turbulent intensity, and the comparison of heat transfer rate, the optimal swirling condition about the swirl and nonswirl axisymmetric air jet. In order to augment the heat transfer on the flat heating surface without introducing any additional power, the technique used in the present work was placement of twisted tape inserted pipe in front of the nozzle exit in order to make a swirl. The effect of swirl degree is investigated in case of S=0., 0.056, 0.111, 0.222 and the velocity of the jet was 14, 20, 26, 32, 38, 44m/s. The distance between the nozle exit and the stagnation point on the impinging plate was the H/D=$1{\sim}14$. In order to analyze of the flow structure which increase heat transfer, the velocity and the turbulent intensity of the axisymmetric jet was measured by a hot wire anemometer according to the swirl number and H/D.

  • PDF

Implementation of Efficient Container Number Recognition System at Automatic Transfer Crane in Container Terminal Yard (항만 야드 자동화크레인(ATC)에서 효율적인 컨테이너번호 인식시스템 개발)

  • Hong, Dong-Hee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.9
    • /
    • pp.57-65
    • /
    • 2010
  • This paper describes the method of efficient container number recognition in colored container image with number plate at ATC(Automatic Transfer Crane) in container terminal yard. At the Sinseondae terminal gate in Busan, the container number recognition system is installed by "intelligent port-logistics system technology development", that is government research and development project. It is the method that it sets up the tunnel structure inside camera on the gate and it recognizes the container number in order to recognize the export container cargo automatically. However, as the automation equipment is introduced to the container terminal and the unmanned of a task is gradually accomplished, the container number recognition system for the confirmation of the object of work is required at ATC in container terminal yard. Therefore, the container number recognition system fitted for it is necessary for ATC in container terminal yard in which there are many intrusive of the character recognition through image including a sunlight, rain, snow, shadow, and etc. unlike the gate. In this paper, hardware components of the camera, illumination, and sensor lamp were altered and software elements of an algorithm were changed. that is, the difference of the brightness of the surrounding environment, and etc. were regulated for recognize a container number. Through this, a shadow problem, and etc. that it is thickly below hung with the sunlight or the cargo equipment were solved and the recognition time was shortened and the recognition rate was raised.