• Title/Summary/Keyword: Plate Anchor

Search Result 130, Processing Time 0.02 seconds

An Experimental Study on Simple Tension Connections for Square CFT Column to Beam Using Internal Plate with Holes (내부유공판을 사용한 각형 CFT 기둥-보 단순인장 접합부의 실험적 연구)

  • Lee, Seong Hui;Jung, Hun Mo;Yang, Il Seung;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.6
    • /
    • pp.575-583
    • /
    • 2009
  • As the height of buildings rises, new structural systems are being applied other than theexisting S, RC, and SRC to decrease the weight of buildings and to make their construction more efficient, CFT structureshad been applied in many building construction projects due to their superior structural performance and construction efficiency. CFT structures need a diaphragm to harmoniously transmit the beam flange load to the column and the opponent beam in connections. Especially, on the right and left sides of the column other beams are connected, The establishment of a diaphragm for the lower part flange load delivery of the beam and guarantee for concrete filing capacity difficulty have (What does this mean?). In this paper, connection details are proposed in the form of a welded vertical plate with a circular hole on the CFT column's interior to harmoniously transmit the lower-part beam flange load to the column and the opponent beam. Thesediaphragm details use the concrete anchor effect in the beam flange load delivery, with the concrete-filled CFT column interior piercing the hole of the perforated plate, and a perforated board is established vertically to improve the concrete filling capacity. To analyze the structural performance of the proposed connection details, five simple tension specimens were made with the following parameters: with our without vertical and horizontal perforated plates, shear hole number, concrete filled or not, thickness of the perforated plate, etc. Then experimental tests were performed on these specimens.

A Study on Piping Support Design Process in Plant Piping System (플랜트 배관계에서 배관지지대 설계 기법에 관한 연구)

  • Chung, Chulsup
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.6
    • /
    • pp.14-20
    • /
    • 2014
  • In this study, the stress analysis for the piping support design is performed as per the rules of the ASME Code, Section III, subsection NF-Component Support which provides a simplified method of design analysis for piping support. This method makes use of simple equations and conservative allowable stress limits for design and service loadings. For the base plate, code equation is satisfied within the allowable limits. Both anchor bolts and pipe strap are governed by the their interaction equations. The stresses resulting from various loadings and their combinations are within the allowable limits specified in the above mentioned ASME Code. Thus, it was proved that the structural integrity of the pump assembly was satisfactory.

A Study on the Structural Standard of the Tube and Coupler Scaffold (단관비계의 구조규격에 관한 연구)

  • 이영섭
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.2
    • /
    • pp.66-75
    • /
    • 1990
  • This study is conducted to establish the structural standard of tube and coupler scaffold which is suitable for our present stuation through the comparison analysis for domestic and foreign standards as well as measurement of field survey. The results of this study are as follows : 1) The load is classified by three categories, light-duty(equal and lower than 150kg/m$^2$), medium-duty(150-250 kg/m$^2$), heavy-duty(250-350kg/m$^2$), and the equivalent horizontal length of side posts is each, 1.5-1.8m, 1.2-1.5m, equal and lower than 1.2m, and the equivalent horizontal length between front and rear posts is each 1.2-1.5m, 0.9-1.2m, equal and lower thatn 0.9m, in accordance with the load classification. 2) The height between upper and lower runner is equal and lower than 1.5m, and the brace across the width of scaffold should be installed within 15m in horizontal direction at 45 degree angle. 3) The entire scaffold should be securely tied to the wall of permanent structure with uslng anchor and bolt at intervals not to exceed 6m in case of non-connection and 4.5m in case of connection in both horizontal and vertical direction. 4) The post should be installed on the sound foundation tied to lumber footing with using base plate, and standard platform plank should be produced in the factory and widely used in the construction field.

  • PDF

Response of a steel column-footing connection subjected to vehicle impact

  • Kang, Hyungoo;Kim, Jinkoo
    • Structural Engineering and Mechanics
    • /
    • v.63 no.1
    • /
    • pp.125-136
    • /
    • 2017
  • This study investigated the performance of a steel column standing on a reinforced concrete footing when it was subjected to collision of an eight-ton single unit truck. Finite element analyses of the structure with different connection schemes were performed using the finite element model of the truck, and the results showed that the behavior of the column subjected to the automobile impact depended largely on the column-footing connection detail. Various reinforcement schemes were investigated to mitigate the damage caused by the car impact. The probability of the model reinforced with a certain scheme to reach a given limit state was obtained by fragility analysis, and the effects of the combined reinforcement methods were investigated based on the equivalent fragility scheme. The analysis results showed that the reinforcement schemes such as increase of the pedestal area, decrease of the pedestal height, and the steel plate jacketing of the pedestal were effective in reducing the damage. As the speed of the automobile increased the contribution of the increase in the number of the anchor bolts and the dowel bars became more important to prevent crushing of the pedestal.

Arthroscopic Cannulated Screw Fixation of Avulsion Fracture of the Intercondylar Eminence of the Tibia in a Child -A Case Report- (소아에서 발생한 전방 십자인대 견열 골절에서 유관 나사못을 이용한 관절경적 정복술 -증례보고-)

  • Moon, Kyu Pill;Kim, Kyung Taek;Kang, Min Soo;Park, Won Ro
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.1
    • /
    • pp.62-65
    • /
    • 2012
  • Avulsion fractures of the intercondylar eminence of the tibia are uncommon. This kind of fracture is most commonly found in adolescents, with an increasing incidence for those involved in competitive athletics. Recently, an arthroscopic procedure is preferred to reduce the operation-related morbidity. Screws, K-wires, Suture anchor have been described as fixation devices. Cannulated screw fixation is a simple method, but this instrument has the risk of causing damage to the growth plate. The authors report good results using cannulated screw in arthroscopic treatment for pediatric anterior cruciate ligament avulsion fracture.

  • PDF

Analytical Structural Integrity for Welding Part at Piping Penetration under Seismic Loads (지진하중이 적용되는 배관 관통부의 용접에 대한 구조 건전성 해석)

  • Choi, Heon-Oh;Jung, Hoon-Hyung;Kim, Chae-Sil
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.1
    • /
    • pp.23-29
    • /
    • 2014
  • The purpose of this paper is to assess the structural integrity of piping penetrations for nuclear power plants. A piping qualification analysis describes loads due to deadweight, pressure difference acts normal to the plate, thermal transients, and earthquakes, among other events, on piping penetrations that have been modeled as an anchor. Amodel was analyzed using a commercial finite element program. Apiping penetration analysis model was constructed with an assembly of pipe, head fittings and sleeves. Normally, the design load, thus obtained, will consist of three moments and three forces, referred to a Cartesian coordinate system. When comparing the stress analysis results from each required cutting position, the general membrane stress intensities and local membrane plus bending stress intensities during a structural evaluation cannot exceed the allowable amount of stress for the design loads. Therefore, the piping penetration design satisfies the code requirements.

Comparison of structural foam sheathing and oriented strand board panels of shear walls under lateral load

  • Shadravan, Shideh;Ramseyer, Chris C.;Floyd, Royce W.
    • Advances in Computational Design
    • /
    • v.4 no.3
    • /
    • pp.251-272
    • /
    • 2019
  • This study performed lateral load testing on seventeen wood wall frames in two sections. Section one included eight tests studying structural foam sheathing of shear walls subjected to monotonic loads following the ASTM E564 test method. In this section, the wood frame was sheathed with four different types of structural foam sheathing on one side and gypsum wallboard (GWB) on the opposite side of the wall frame, with Simpson HDQ8 hold down anchors at the terminal studs. Section two included nine tests studying wall constructed with oriented strand board (OSB) only on one side of the wall frame subjected to gradually applied monotonic loads. Three of the OSB walls were tied to the baseplate with Simpson LSTA 9 tie on each stud. From the test results for Section one; the monotonic tests showed an 11 to 27 percent reduction in capacity from the published design values and for Section two; doubling baseplates, reducing anchor bolt spacing, using bearing plate washers and LSTA 9 ties effectively improved the OSB wall capacity. In comparison of sections one and two, it is expected the walls with structural foam sheathing without hold downs and GWB have a lower wall capacity as hold down and GWB improved the capacity.

Experimental and numerical investigation on exposed RCFST column-base Joint

  • Ben, Mou;Xingchen, Yan;Qiyun, Qiao;Wanqiu, Zhou
    • Steel and Composite Structures
    • /
    • v.45 no.5
    • /
    • pp.749-766
    • /
    • 2022
  • This paper investigates the seismic performance of exposed RCFST column-base joints, in which the high-strength steel bars (USD 685) are set through the column and reinforced concrete foundation without any base plate and anchor bolts. Three specimens with different axial force ratios (n = 0, 0.25, and 0.5) were tested under cyclic loadings. Finite element analysis (FEA) models were validated in the basic indexes and failure mode. The hysteresis behavior of the exposed RCFST column-base joints was studied by the parametrical analysis including six parameters: width of column (D), width-thickness ratio (D/t), axial force ratio (n), shear-span ratio (L/D), steel tube strength (fy) and concrete strength (fc). The bending moment of the exposed RCFST column-base joint increased with D, fy and fc. But the D/t and L/D play a little effect on the bending capacity of the new column-base joint. Finally, the calculation formula is proposed to assess the bending moment capacities, and the accuracy and stability of the formula are verified.

Theoretical rotational stiffness of the flexible base connection based on parametric study via the whale optimization algorithm

  • Mahmoud T. Nawar;Ehab B. Matar;Hassan M. Maaly;Ahmed G. Alaaser;Osman Hamdy
    • Structural Engineering and Mechanics
    • /
    • v.88 no.1
    • /
    • pp.43-52
    • /
    • 2023
  • This paper handles the results of an extensive parametric study on the rotational stiffness of the flexible base connection using ABAQUS program. The results of the parametric study show the relation between the applied moment and the relative rotation for 96 different base connections. The configurations of the studied connections considered different numbers, diameters, and spacing of the anchor bolts along with different thicknesses of the base plate to investigate the effect of these parameters on the rotational stiffness behavior. The results of the previous parametric research used through the whale optimization algorithm (WOA) to detect different equation formulation of the moment-rotation (M-Ɵr) equation to detect optimum equation simulates the general nonlinear rotational behavior of the flexible base connection considering all variables used in the parametric study. WOA is a relatively new promising algorithm, which is used in different types of optimization problems. For more verification, the classical genetic algorithm (GA) is used to make a comparison with WOA results. The results show that WOA is capable of getting an optimum equation of the M-Ɵr relation, which can be used to simulate the actual rotational stiffness of the flexible base connections. The rotational stiffness at H/150 can be calculated using WOA (1) method and be used as a design aid for engineering design.

Re-review of the Structure of the Jeongsa-Kisun (Senior Envoy Ship) in the Joseon Dynasty from the Perspective of Professional Shipbuilding Engineering (조선통신사 정사 기선(騎船) 구조의 조선기술 연구)

  • HONG Sunjae
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.4
    • /
    • pp.242-275
    • /
    • 2022
  • This study tries to reveal the structure of the "Kisun"(senior envoy ship) taken by senior envoys for the 10th to 12th visits to Japan from the perspective of professional shipbuilding engineering focusing on the theory of the ship in the travel logs of royal envoys to Japan (Sahaengrok) written by Joseon Tongsinsa that includes 12 visits to Japan for about 200 years from 1607 to 1811. The results of the study showed that the size of Kisun for the 10th to 12th envoy visits was 19 Pa (把) and a half in length and 6 Pa (把) and 2 Cheok (尺) in width. The height of the Sampan was found to be 2 Pa (把) and 1 Cheok (尺) based on records in Gyemisusarok and Jeungjeonggyorinji. The structure of Kisun was different for each visit but, it was found that Kisun was mainly composed of a main deck, bow (bow plate, stem plate), stern (stern plate), Sampan, Meonge (support), Garyong (support), Sinbang, Gungji, deck, two masts and sail, Gurejjak (mast support), Panok, stern Panok, Taru, dodger, anchor reel, stairs, rail, rudder, oar, and anchor. In addition, wood and iron nails were used together for connection. It was also found that the sail was made of herbage and cotton. This study found that Kisun, which was operated for the 10th and 12th envoy visits, was big in terms of length and height among the Joseon Tongsinsa fleet to show the authority and dignity of Joseon and that it had passages outside on the sides of the vessel and paddles were located between the sides and Panok structure and rails were installed on four sides on the Panok, improving stability and linear beauty. The walls of Panok were decorated with the royal Dancheong pattern and fancy murals. In addition, it was found that they wished for a safe voyage by drawing a demon face on the bow. Therefore, it was revealed that Kisun, which was taken by envoys as recorded in travel logs, was made by the state and equipped with structures and functions that enabled international voyages.