• 제목/요약/키워드: Plastic tube

검색결과 385건 처리시간 0.031초

심용접 튜브를 사용한 벌지 성형에서의 터짐불량 예측 (Numerical prediction of bursting failure in bulge forming using a seamed tube)

  • Kim, J.;Kim, Y.W;B.S. Kang
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 춘계학술대회논문집
    • /
    • pp.240-243
    • /
    • 2003
  • Finite element analyses for bursting failure prediction in bulge forming under combined internal pressure and independent axial feeding are carried out. By means of the FEM combined with Oyane's ductile fracture criterion based on Hills quadratic plastic potential, the forming limit and bursting pressure level are investigated for a seamed tube that comprises of weldment, heat affected zone(HAZ) and base material parts. Especially, in order to determine the material property of HAZ tensile tests for the base material and the weld metal are executed based on iso-strain approach. Finally, through a series of bulge forming simulations with consideration of the weldment and HAZ it is concluded that the proposed method would be able to predict the bursting pressure and fracture initiation site more realistically, so the approach can be extended to a wide range of practical bulge forming processes.

  • PDF

두 개의 비대칭 축방향 관통균열이 존재하는 증기발생기 세관의 소성붕괴압력 평가 (Evaluation of Plastic Collapse Pressure for Steam Generator Tube with Non-Aligned Two Axial Through-Wall Cracks)

  • 문성인;장윤석;이진호;송명호;최영환;김영진
    • 대한기계학회논문집A
    • /
    • 제29권8호
    • /
    • pp.1070-1077
    • /
    • 2005
  • The $40\%$ of wall thickness criterion which has been used as a plugging rule is applicable only to a single cracked steam generator tubes. In the previous studies performed by authors, several failure prediction models were introduced to estimate the plastic collapse pressures of steam generator tubes containing collinear or parallel two adjacent axial through-wall cracks. The objective of this study is to examine the failure prediction models and propose optimum ones for non-aligned two axial through-wall cracks in steam generator tubes. In order to determine the optimum ones, a series of plastic collapse tests and finite element analyses were carried out for steam generator tubes with two machined non-aligned axial through-wall cracks. Thereby, either the plastic zone contact model or COD based model was selected as the optimum one according to axial distance between two clacks. Finally, the optimum failure prediction model was used to demonstrate the conservatism of flaw characterization rules for various multiple flaws according to ASME code.

Failure analysis of tubes under multiaxial proportional and non-proportional loading paths

  • Mohammad Hossein Iji;Ali Nayebi
    • Steel and Composite Structures
    • /
    • 제47권2호
    • /
    • pp.289-296
    • /
    • 2023
  • The failure of a thin-walled tube was studied in this paper based on three failure models. Both proportional and non-proportional loading paths were applied. Proportional loading consisted of combined tension-torsion. Cyclic non-proportional loading was also applied. It was a circular out-of-phase axial-shear stress loading path. The third loading path was a combination of a constant internal pressure and a bending moment. The failure models under study were equivalent plastic strain, modified Mohr-Coulomb (Bai-Wierzbicki) and Tearing parameter models. The elasto-plastic analysis was conducted using J2 criterion and nonlinear kinematic hardening. The return mapping algorithm was employed to numerically solve the plastic flow relations. The effects of the hydrostatic stress on the plastic flow and the stress triaxiality parameter on the failure were discussed. Each failure model under study was utilized to predict failure. The failure loads obtained from each model were compared with each other. The equivalent plastic strain model was independent from the stress triaxiality parameter, and it predicted the highest failure load in the bending problem. The modified Mohr-Coulomb failure model predicted the lowest failure load for the range of the stress triaxiality parameter and Lode's angle.

국부충격하중을 받는 원관의 삭성변형에 관한 고찰 (Study on the plastic deformation of a cylinder subjected to localized impulsive pressure)

  • 김천욱;주영우
    • 대한기계학회논문집
    • /
    • 제5권2호
    • /
    • pp.131-138
    • /
    • 1981
  • The effect of axial stress on the plastic deformation of rigid-perfectly plastic cylindrical tube under the impulsive band pressure is investigated. It is assumed that the tube is constructed with the material of Tresca's yield criterion. A closed from sloution is obtained for a rectangular pulse shape of uniform band pressure by using the circumscribed yield surface. The analysis shows that the effect ot exial stress is negligible when the dimensionless axial stress(n$\sub$x/= N$\sub$x/.delta.$\sub$y/H) is less than 0.2 or the dimensionless whdth of band pressure(.xi.=C/.root.RH) is greater than 2, but the effect of axial stress is of considerable importance when the axial stress is greater than 0.3 and the width of band pressure is less than 1.

자동차용 브레이크 튜브 및 플레어 너트의 제조에 관한 연구 (A Study on the Manufacturing of Brake tube and Flare nut for Automobiles)

  • 한규택
    • 한국공작기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.113-119
    • /
    • 2008
  • The purpose of the present paper is to investigate the optimal shape of the brake tube-end and flare nut for automobiles using the $DEFORM^{TM}-3D$, finite element code. A flare nut is a small and important part used to join a brake tube-end in automobiles. In this instance, we studied the optimal forging processes for the tube-end and flare nut. Finite element analysis has been carried out to predict an optimal shape of the tube-end and flare nut. Also the simulation results were reflected to the forging processes design for the tube-end and flare nut. The shape of the tube-end and flare nut is in agreement with the finite element simulation and the test results.

Clinical Factors Associated with the Non-Operative Airway Management of Patients with Robin Sequence

  • Albino, Frank P.;Wood, Benjamin C.;Han, Kevin D.;Yi, Sojung;Seruya, Mitchel;Rogers, Gary F.;Oh, Albert K.
    • Archives of Plastic Surgery
    • /
    • 제43권6호
    • /
    • pp.506-511
    • /
    • 2016
  • Background The indications for surgical airway management in patients with Robin sequence (RS) and severe airway obstruction have not been well defined. While certain patients with RS clearly require surgical airway intervention and other patients just as clearly can be managed with conservative measures alone, a significant proportion of patients with RS present with a more confusing and ambiguous clinical course. The purpose of this study was to describe the clinical features and objective findings of patients with RS whose airways were successfully managed without surgical intervention. Methods The authors retrospectively reviewed the medical charts of infants with RS evaluated for potential surgical airway management between 1994 and 2014. Patients who were successfully managed without surgical intervention were included. Patient demographics, nutritional and respiratory status, laboratory values, and polysomnography (PSG) findings were recorded. Results Thirty-two infants met the inclusion criteria. The average hospital stay was 16.8 days (range, 5-70 days). Oxygen desaturation (<70% by pulse oximetry) occurred in the majority of patients and was managed with temporary oxygen supplementation by nasal cannula (59%) or endotracheal intubation (31%). Seventy-five percent of patients required a temporary nasogastric tube for nutritional support, and a gastrostomy tube placed was placed in 9%. All patients continued to gain weight following the implementation of these conservative measures. PSG data (n=26) demonstrated mild to moderate obstruction, a mean apneahypopnea index (AHI) of $19.2{\pm}5.3events/hour$, and an oxygen saturation level <90% during only 4% of the total sleep time. Conclusions Nonsurgical airway management was successful in patients who demonstrated consistent weight gain and mild to moderate obstruction on PSG, with a mean AHI of <20 events/hour.

노출된 영구 심박조율기의 치험례 (Clinical Experience of Exposed Pacemakers)

  • 오득영;김태형;이종원;이백권;한기택;안상태;최윤석
    • Archives of Plastic Surgery
    • /
    • 제32권6호
    • /
    • pp.753-756
    • /
    • 2005
  • In the cases of severe arrythmia and conduction failure, a permanent implanted pacemaker is considered an essential treatment modality with less complication rate, broad indications and low morbidity. However, some pacemakers needs to be removed or replaced due to infection, in need of a lead upgrade, elective replacement, conduction failure or insulation failure. The most common indication for pacemaker extraction is infection. Conservative treatments such as administration of intravenous antibiotics and limitation of debridement are not effective and the removal of the entire pacing system is considered to be the best approach to pacemaker pocket infection. Although a locking stylet, a laser sheath and other newer methods of transvenous lead extraction have been proven to be effective, all leads cannot be removed. Moreover, major complications such as, cardiac tamponade and respiratory arrest during leads extraction procedure should not be ignored. We experienced two cases of exposed pacemakers in the subclavicular region. After removing the pacemaker body, exposed proximal lead was pulled out and cut off. The end of remnant external insulation tube was tied to prevent infection propagation between external insulation tube and inner metalic coil. Wounds were covered by local flap coverage. No other problems were detected during the one-year follow-up. Since there are few reports on lead-preserving method of treating limited infection of exposed pacemakers, we would like to present our new method for treating exposed pacemakers.

알루미늄/GFRP 혼성튜브의 굽힘붕괴 특성 (The characteristics of bending collapse of aluminum/GFRP hybrid tube)

  • 송민철;이정주
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 추계학술발표대회 논문집
    • /
    • pp.84-87
    • /
    • 2000
  • Square tubes used for vehicle structure components have an important role on keeping its stiffness and preserving occupant safety in vehicle collision and rollover in which it experience axial collapse, bending collapse or both. Bending collapse, which absorbs kinetic energy of the impact and retains a survival space for the occupant, is a dominant failure mode in oblique collision and rollover. Thus, in this paper, the bending collapse characteristics such as the maximum bending moment and energy absorption capacity of the square tube replaced by light-weight material were evaluated and presented. The bending test of cantilever tubes which were fabricated with aluminum, GFRP and aluminum/ GFRP hybrid by co-curing process was performed. Then the maximum bending moment and the energy absorption capacity from the moment-angle curve were evaluated. Based on the test results, it was found that aluminum/ GFRP hybrid tube can show better specific energy absorption capacity compared to the pure aluminum or GFRP tube and can convert unstable collapse mode which may occur in pure GFRP tube to stable collapse mode like a aluminum tube in which plastic hinge is developed.

  • PDF

비골골절치료에서 기도 튜브 머로셀®의 유용성 (The Usefulness of Airway Tube Merocel® on Treatment of Nasal Bone Fracture)

  • 정연주;최영웅;남상현;윤길용
    • 대한두개안면성형외과학회지
    • /
    • 제10권1호
    • /
    • pp.14-18
    • /
    • 2009
  • Purpose: Nasal packing materials are almost inserted at the end stage of closed reduction of nasal bone for postoperative bleeding control and stabilization of nasal bone. Conventionally, vaseline gauze was used for packing of nasal cavity. These days, Surgeons have tried to apply $Merocel^{(R)}$ into the nasal cavity more easily. It is difficult for patients to continue keeping the nasal packs for more than a week due to breathing difficulty. Moreover, nasal packing itself can also cause headache, dry mouth, stuffiness, etc. Methods: We performed a prospective study from March 1, 2008 to July 31, 2008. One hundred patients were divided into "$Merocel^{(R)}$ packing group" and "$Merocel^{(R)}$ and Airway Tube $Merocel^{(R)}$ packing group". Using two kinds of materials to each group after closed reduction, we observed and compared the amount of bleeding between two groups. We recorded patient's uncomfortable symptoms which were divided into four groups each 6, 24, 48 hours after nasal packing. Results: The result of the bleeding amount of Air Tube $Merocel^{(R)}$ group after 6 hours of nasal packing is that 3 people belong to mild group, 38 people moderate group, and 9 people severe group. After 6 hours of nasal packing, 11 patients have no complains. 16 patients were mild, 21 patients were moderate, 2 patients were severe. After 24 hours of nasal packing, no complain(18 patients), mild(24 patients), moderate(6 patients), severe(0 patient). After 48 hours of nasal packing, no complain(25 patients), mild(20 patients), moderate(5 patients), severe(0 patient). Conclusion: Regarding the amount of bleeding, there are no difference between two groups. In case of Air Tube $Merocel^{(R)}$ group, patient's discomfort is gradually improved after 24 hours of nasal packing, After 48 hours of nasal packing, most of the patients do not experience headache, dry mouth, stuffiness, etc. Therefore, Air Tube $Merocel^{(R)}$ can be useful for bleeding control. Moreover, it helps patients to breathe through nose more easily and reduce discomfort.