• Title/Summary/Keyword: Plastic stent

Search Result 32, Processing Time 0.023 seconds

Finite Element Analysis of Stent Expansion Considering Stent-Balloon Interaction (스텐트와 풍선의 상호작용을 고려한 스텐트 팽창의 유한요소해석)

  • Oh Byung-Ki;Cho Hae-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.1 s.232
    • /
    • pp.156-162
    • /
    • 2005
  • Stouts are frequently used throughout the human body, but the most critical areas are in coronary arteries. They open pathways in vessels and supply blood directly to the heart muscle. To simulate behavior of expansion for the coronary stent by balloon, the commercial finite element code LS-DYNA and ANSYS were used in the analysis. The explicit method is used to analyze the expansion of the stent and the implicit method is performed to simulate the springback that developed in a stent after the balloon pressure has been removed. Finally the experimental results for the expansion of the PS153 stents were compared with the FEM results. The springback was measured with the stents subjected to no external pressure to which stents are subjected in vivo. The simulated results were in good agreement with experimental results. Standard mechanical characteristics such as stress, plastic strains, and springback can be derived from the numerical results. These data can be used to determine maximum expansion diameter without fracture and expansion pressure considering elastic recoil.

Single-pigtail plastic stent made from endoscopic nasobiliary drainage tubes in endoscopic ultrasound-guided gallbladder drainage: a retrospective case series

  • Koichi Soga
    • Clinical Endoscopy
    • /
    • v.57 no.2
    • /
    • pp.263-267
    • /
    • 2024
  • Technical failure of endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) is often attributed to device failure. To rectify this problem, we developed a single-pigtail plastic stent (SPPS) for EUS-GBD. We retrospectively reviewed the cases of four patients who underwent EUS-GBD for acute cholecystitis. To prepare the SPPS, a 7.5-Fr endoscopic nasobiliary drainage tube was cut to an appropriate length. The use of SPPS during EUS-GBD was successful from both technical and clinical standpoints. The SPPS spontaneously detached 57 days after the procedure in patient 4 and 412 days after the procedure in patient 1. Patient 1 developed cholecystitis after 426 days and was managed with antibiotics. The other three patients did not develop any complications after surgery. In conclusion, we designed a new SPPS dedicated to EUS-GBD and established its technical feasibility and clinical effectiveness.

Optimal endoscopic drainage strategy for unresectable malignant hilar biliary obstruction

  • Itaru Naitoh;Tadahisa Inoue
    • Clinical Endoscopy
    • /
    • v.56 no.2
    • /
    • pp.135-142
    • /
    • 2023
  • Endoscopic biliary drainage strategies for managing unresectable malignant hilar biliary obstruction differ in terms of stent type, drainage area, and deployment method. However, the optimal endoscopic drainage strategy remains unclear. Uncovered self-expandable metal stents (SEMS) are the preferred type because of their higher functional success rate, longer time to recurrent biliary obstruction (RBO), and fewer cases of reintervention than plastic stents (PS). Other PS subtypes and covered SEMS, which feature a longer time to RBO than PS, can be removed during reintervention for RBO. Bilateral SEMS placement is associated with a longer time to RBO and a longer survival time than unilateral SEMS placement. Unilateral drainage is acceptable if a drainage volume of greater than 50% of the total liver volume can be achieved. In terms of deployment method, no differences were observed in clinical outcomes between side-by-side (SBS) and stent-in-stent deployment. Simultaneous SBS boasts a shorter procedure time and higher technical success rate than sequential SBS. This review of previous studies aimed to clarify the optimal endoscopic biliary drainage strategy for unresectable malignant hilar biliary obstruction.

SURGICAL STENT FABRICATION AND CLINICAL APPLICATION FOR ORTHOGNATHIC SURGERY USING Cone-Beam CT (Cone-Beam CT를 이용한 악교정 수술용 스텐트 제작과 임상 적용)

  • Kim, Yong-Il;Kim, Jong-Ryoul;Kim, Seong-Sik;Son, Woo-Sung;Park, Soo-Byung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.158-166
    • /
    • 2009
  • The application of CT with basis on 3 dimensional-reconstruction is getting more widely practiced. With the data obtained from cone-beam computed tomography(CBCT), not only the diagnosis of the patient with skeletal abnormality but also the virtual simulation of the orthognathic surgery were performed and its application would be popular in orthodontic field. We reported a case, a 19-year old man who was diagnosed mandibular prognathism and required orthognatic surgery. In this case, the virtual orthognathic surgery was simulated and surgical wafer was fabricated by using CBCT data. That wafer was applied the actual orthognathic surgery. After preoperative orthodontic treatment, we prepared surgery as follows. : (l)Acquisition of 3D image data, (2)Reconstruction of 3-dimensional virtual model, (3)Virtual model surgery, (4)Extraction of stere-olithographic image, (5)Check-up for occlusal interference, (6)Fabrication of surgical stent by stereolithography. Bilateral sagittal split ramus osteotomy was operated and used stereolithographic surgical stent. 1 month later, we superimposed CBCT datas of virtual surgery and that of actual surgery, and then compared the result. CT data's application for othognathic surgery yielded satisfactory outcomes.

Correction of Nostril Stenosis with W-plasty, Perialar Flap and Foley Expansion Exercise (W-성형술, 비익변피판 및 도뇨관 훈련을 이용한 비공협착의 교정)

  • Hong, Ki-Yong;Lee, Yoon-Ho
    • Archives of Plastic Surgery
    • /
    • v.37 no.2
    • /
    • pp.143-147
    • /
    • 2010
  • Purpose: Nostril stenosis is an uncommon deformity that develops as a consequence of smallpox, chickenpox, tuberculosis, syphilis, congenital malformations etc. There have been several studies on the surgical techniques to treat it. However, it is difficult to maintain the result for a long time. The goal of this study is to evaluate the use of Wplasty, perialar flap as an operative techniques and expansion exercise using Foley catheter as a method to keep the patency of nostril. Methods: This is a retrospective review of the senior surgeon's (Y.L.) patients who underwent W-plasty and a perialar flap. Patients treated from 2005 to 2009 were reviewed and the postoperative results were evaluated. Average patient age was 24 years, ranged from 1 to 61 years, average follow-up period was 27.5 months, ranged from 3 to 77 months. The mild deformity was released with an incision and expansion by the ballooning of a Foley catheter and corrected by W-plasty only. However, a severe deformity required an additional procedure including perialar flap transposition. During the postoperative period, the patients maintained a nasal stent and exercise using a Foley catheter to prevent recurrence. Results: Five cases of nostril stenosis in four patients were treated using this technique. One case was corrected with W-plasty only, but four cases were more severe and were corrected with W-plasty and a perialar flap. There were no perioperative complications. The patients were satisfied with the results and retained a good shape during the follow-up periods. Conclusion: Nostril stenosis can be corrected with W-plasty and a perialar flap. A perialar flap is added if W-plasty is unable to correct the deformity. A postoperative nasal stent and expansion with a Foley catheter can help in preventing recurrences.

A Study on Optimal Shape of Stent by Finite Element Analysis (유한요소 해석을 이용한 스텐트 최적형상 설계)

  • Lee, Tae-Hyun;Yang, Chulho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.1-6
    • /
    • 2017
  • Stents are widely used as the most common method of treating coronary artery disease with implants in the form of a metal mesh. The blood flow is normalized by inserting a stent into the narrowed or clogged areas of the human body. In this study, the mechanical characteristics of a stent are investigated according to the variations of its design parameters by the Taguchi method and finite element analysis. A stent model of the Palmaz-Schatz type was used for the analysis. In the analysis, an elasto-plastic material model was adopted for the stent and a hyper-elastic model was used for the balloon. The main interest of this study is to investigate the effects of the design parameters which reduce the possibility of restenosis by adjusting the recoil amount. A Taguchi orthogonal array was constructed on the model of the stent. The thickness and length and angle of the slot were selected as the design parameters. The amounts of radial recoil and longitudinal recoil were calculated by finite element analysis. The statistical analysis using the Taguchi method showed that optimizing the shape of the stent could reduce the possibility of restenosis. The optimized shape showed improvements of recoil in the radial and longitudinal directions of ~1% and ~0.1%, respectively, compared to the default model.

In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants

  • Huh, Young-June;Choi, Bo-Ram;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.139-146
    • /
    • 2012
  • Purpose: An individual surgical stent fabricated from computed tomography (CT) data, called a CT-guided stent, would be useful for accurate installation of implants. The purpose of the present study was to introduce a newly developed CT-guided stent with a simple design and evaluate the accuracy of the stent placement. Materials and Methods: A resin template was fabricated from a hog mandible and a specially designed plastic plate, with 4 metal balls inserted in it for radiographic recognition, was attached to the occlusal surface of the template. With the surgical stent applied, CT images were taken, and virtual implants were placed using software. The spatial positions of the virtually positioned implants were acquired and implant guiding holes were drilled into the surgical stent using a specially designed 5-axis drilling machine. The surgical stent was placed on the mandible and CT images were taken again. The discrepancy between the central axis of the drilled holes on the second CT images and the virtually installed implants on the first CT images was evaluated. Results: The deviation of the entry point and angulation of the central axis in the reference plane were $0.47{\pm}0.27$ mm, $0.57{\pm}0.23$ mm, and $0.64{\pm}0.16^{\circ}$, $0.57{\pm}0.15^{\circ}$, respectively. However, for the two different angulations in each group, the $20^{\circ}$ angulation showed a greater error in the deviation of the entry point than did the $10^{\circ}$ angulation. Conclusion: The CT-guided template proposed in this study was highly accurate. It could replace existing implant guide systems to reduce costs and effort.

Influence of biliary stents on the diagnostic outcome of endoscopic ultrasound-guided tissue acquisition from solid pancreatic lesions: a systematic review and meta-analysis

  • Suprabhat Giri;Shivaraj Afzalpurkar;Sumaswi Angadi;Jijo Varghese;Sridhar Sundaram
    • Clinical Endoscopy
    • /
    • v.56 no.2
    • /
    • pp.169-179
    • /
    • 2023
  • Background/Aims: This meta-analysis analyzed the effect of an indwelling biliary stent on endoscopic ultrasound (EUS)-guided tissue acquisition from pancreatic lesions. Methods: A literature search was performed to identify studies published between 2000 and July 2022 comparing the diagnostic outcomes of EUS-tissue acquisition (TA) in patients with or without biliary stents. For non-strict criteria, samples reported as malignant or suspicious for malignancy were included, whereas for strict criteria, only samples reported as malignant were included in the analysis. Results: Nine studies were included in this analysis. The odds of an accurate diagnosis were significantly lower in patients with indwelling stents using both non-strict (odds ratio [OR], 0.68; 95% confidence interval [CI], 0.52-0.90) and strict criteria (OR, 0.58; 95% CI, 0.46-0.74). The pooled sensitivity with and without stents were similar (87% vs. 91%) using non-strict criteria. However, patients with stents had a lower pooled sensitivity (79% vs. 88%) when using strict criteria. The sample inadequacy rate was comparable between groups (OR, 1.12; 95% CI, 0.76-1.65). The diagnostic accuracy and sample inadequacy were comparable between plastic and metal biliary stents. Conclusions: The presence of a biliary stent may negatively affect the diagnostic outcome of EUS-TA for pancreatic lesions.

Portal cavernography during endoscopic retrograde cholangiopancreatography: from bilhemia to hemobilia

  • Rawad A. Yared;Paraskevas Gkolfakis;Arnaud Lemmers;Vincent Huberty;Thierry Degrez;Jacques Deviere;Daniel Blero
    • Clinical Endoscopy
    • /
    • v.56 no.4
    • /
    • pp.521-526
    • /
    • 2023
  • Portobiliary fistulas are rare but may lead to life-threatening complications. Biliary plastic stent-induced portobiliary fistulas during endoscopic retrograde cholangiopancreatography have been described. Herein, we present a case of portal cavernography and recurrent hemobilia after endoscopic retrograde cholangiopancreatography in which a portobiliary fistula was detected in a patient with portal biliopathy. This likely indicates a change in clinical presentation (from bilhemia to hemobilia) after biliary drainage that was successfully treated by placement of a fully covered, self-expandable metallic stent.