Juil Park;Kichang Han;Joon Ho Kwon;Man-Deuk Kim;Jong Yun Won;Sungmo Moon;Gyoung Min Kim
Korean Journal of Radiology
/
제24권12호
/
pp.1241-1248
/
2023
Objective: To evaluate the role of percutaneous pancreatic stent placement in postoperative pancreaticojejunostomy stenosis (PJS). Materials and Methods: This retrospective single-center study included seven procedures in five patients (four males and one female; median age, 63 years) who underwent percutaneous pancreatic stent placement for postoperative PJS between January 2005 and December 2021. The patients were referred to interventional radiology because of unfavorable anatomy or bowel abnormalities. The pancreatic duct was accessed under ultrasound and/or computed tomography guidance. A stent was placed after balloon dilatation of the PJS. Moreover, plastic stents were placed for the first two procedures, whereas bare-metal stents were used for the remaining five procedures. Technical success was defined as the successful placement of stents for the PJS, meanwhile, clinical success was defined as the normalization of pancreatic enzymes without recurrence of pancreatitis. Results: Pancreatic duct access and stent placement were successfully performed in all patients (technical success rate: 100%). All the procedures initially yielded clinical success. However, recurrence of pancreatitis was observed after two procedures that used plastic stents because of stent migration at 0.3 and 3 months after the procedure. In contrast, no instances of recurrent pancreatitis were noted after metal stent placement for a follow-up duration of 1-36 months. No serious procedure-related adverse events were observed. Conclusion: Percutaneous pancreatic stent placement may be a viable option for patients with postoperative PJS in whom an endoscopic approach is not feasible. Metal stents may be considered over plastic stents for the management of PJS, considering the possible lower stent migration and infeasibility of frequent endoscopic stent exchange due to the altered anatomy.
Purpose: In case of facial injury, a canalicular injury is common. Many methods and materials have been used for reconstruction of lacrimal canaliculi. Silicone tube is the most widely used material, generally with pigtail probe or stainless steel probe. But it has still many problems. The authors guess that reconstruction using Mini $Monoka^{(R)}$ will reduce those problems and will be more successful. Methods: From July, 2003 to November, 2006 in 24 patients with canalicular injury, 11 cases were recon- structed with former silicone tube and 13 cases were treated with Mini $Monoka^{(R)}$. Results: The mean follow-up period was 3 months. The results of reconstruction were classified into three groups(Normal, Fair, Poor). In 13 cases with Mini $Monoka^{(R)}$ stent, 10 cases were normal, 3 were fair, and no poor cases. But in 11 cases with bicanaliculus silicone stent, 6 cases were normal, 3 were fair, and 2 were poor. Conclusion: Compared with bicanaliculus silicone stent, Mini $Monoka^{(R)}$ stent is fixed well, has no aesthetic problems, makes less foreign body sensation. And the results were successful.
Purpose: Canalicular laceration is relatively common due to its exposed, vulnerable location in case of facial trauma. Conjunctivodacryocystorhinostomy has been the standard treatment for canalicular obstruction secondary to unrepaired canalicular laceration. In spite of a high rate of relieving tear-duct obstruction, this method is noted to be associated with low rate of patient satisfaction and a number of complications. The goal of this study is to report the good results of delayed lacrimal stent implantation with Mini Monoka$^{(R)}$ for patients whose canaliculi were not repaired by initial surgery. Methods: From May of 2005 to February of 2007, four patients who underwent delayed lacrimal stent implantation using Mini Monoka$^{(R)}$ in canalicular laceration were retrospectively reviewed. First, the previous scar incision was made over the lower lid and we identified the cut end of proximal lacerated canaliculus. The Mini Monoka$^{(R)}$ was passed through the punctum to the cut end of the proximal lacerated canaliculus. We identified the cut end of the distal lacerated canaliculus, whose cut end has rolled white edges after careful excision of the scarred lid tissue. We then passed Mini Monoka$^{(R)}$ through the lacerated inferior canaliculus. Using an operating microscope, we placed three interrupted sutures of 8-0 Ethilon to join the canalicular ends. Silicone stent was left in place for 6 months. The mean age of the patients was 48.5 years (range, 35 to 59 years). The time interval from initial trauma to delayed lacrimal stent implantation was between 3 and 31 days. Follow-up periods ranged from 12 and 20 months. Results: The results of reconstruction were classified into normal, fair and poor. Patent lacrimal drainage systems were achieved in three of the four cases. In one case, epiphora was encountered. No cases of stent displacement, conjunctivitis or granuloma formation were encountered. Conclusion: Even though canalicular reconstruction was delayed for a long time, attempting canalicular reconstruction would be acceptable before considering secondary operations like dacryocystorhinostomy and conjunctivodacryocystorhinostomy.
Bo Kyung Kim;Jung Won Chun;Sang Hyub Lee;Ji Kon Ryu;Yong-Tae Kim;Woo Hyun Paik
Clinical Endoscopy
/
제55권4호
/
pp.564-569
/
2022
A lumen-apposing metal stent (LAMS) is a saddle-shaped stent with large flanges at both ends, thereby preventing stent migration and helping with approximation of the adjacent structures. We report the case of a 25-year-old female with remnant choledochal cyst which was successfully treated with LAMS after initial treatment failure with a plastic stent. Although complete excision of the cyst is the definite treatment of choledochal cysts, endoscopic ultrasonography-guided cystoduodenostomy can be considered in cases wherein surgery is not feasible and dysplasia is not present. LAMS may be preferred to plastic stents for effective resolution of remnant choledochal cyst and prevention of ascending infection.
배경/목적: 담도암에서 플라스틱 스텐트 너비에 따른 스텐트 생존 차이에 대한 데이터는 부족하다. 이번 연구의 목적은 담도암에서 7-프렌치와 10-프렌치 플라스틱 스텐트의 생존 차이를 보고 어떤 인자가 개방성에 영향을 미치는지 확인하고자 한다. 방법: 2010년 1월부터 2014년 10월까지 연세대학교 원주세브란스기독병원에서 담도암으로 담도가 막힌 환자들을 등록하였다. 결과: 총 215명(7-프렌치:10-프렌치 = 89명:126명)의 환자를 후향적으로 등록하였다. 암의 위치는 총담관(111명), 간문부 담관(45명), 바터팽대부(59명)였다. 스텐트 이동이나 폐쇄는 두 군 간에 통계적 차이가 없었다. 중앙 스텐트 생존은 7-프렌치의 경우 3.3개월이었고 10-프렌치의 경우 5.9개월이었다(p = 0.543). 플라스틱 스텐트 너비는 스텐트 생존에 영향을 미치지 않았다(Hazard Ratio: 1.11, 95% CI 0.71-1.73, p = 0.649). 결론: 담도암 치료에 있어 7-프렌치와 10-프렌치 플라스틱 스텐트는 스텐트 이동이나 폐쇄 차이가 없었고 스텐트 생존에 있어 7-프렌치 플라스틱 스텐트가 10-프렌치에 비해 열등하지 않았다.
췌공장문합술 후 췌관 내 스텐트를 삽입하는 것은 수술 후에 췌장루나 췌관 협착의 발생을 예방하기 위해 널리 시행하는 술기이다. 그러나 삽입한 스텐트가 막히거나 이동하는 등 스텐트에 의해서도 다양한 합병증이 발생할 수 있다. 저자들은 췌관에 삽입한 플라스틱 스텐트가 이동하면서 발생된 매우 드문 합병증의 예를 보고하고자 한다. 유문부 보존 췌두부십이지장 절제술 시행 후 췌장 내 삽입한 스텐트는 공장으로 이동하여 스텐트-돌 복합체의 근원으로 작용하여 공장 폐색을 일으켰다. 스텐트-돌 복합체는 탐색적 개복술로 제거되었다.
Cholangiocarcinoma, though very rare in Western countries, is one of the commonest liver malignancies in Southeast Asia, especially in Thailand. More than half of the patients present with advanced stage disease. Given the poor treatment outcomes of adjuvant therapeutic options, many patients undergo only biliary drainage for palliative treatment. Clinical characteristics and treatment outcomes after biliary stenting were here analyzed for a total of 224 uresectable cholangiocarcinoma cases, 58.9% in men. The mean age was 61.5 years. Hilar involvement was the most common location. The patients underwent biliary drainage using plastic and metallic stents equally, early stent occlusion being encountered in 21.4% and 10.7%, respectively. The median survival time was 4.93 months for patients who received plastic and 5.87 months for patients who received metallic stents.
A 44-year-old woman underwent sleeve gastrectomy, which was complicated by a leak. She was treated with two sessions of endoscopic internal drainage using plastic double-pigtail stents. Her clinical evolution was favorable, but four months after the initial stent placement, she became symptomatic, and a gastrobronchial fistula with the proximal end of the stents invading the diaphragm was diagnosed. She was treated with antibiotics, plastic stents were removed, and a partially covered metallic esophageal stent was placed. Eleven weeks later, the esophageal stent was removed with no evidence of fistula. Inappropriate stent size, position, stenting duration, and persistence of low-grade inflammation could explain the patient's symptoms and provide a mechanism for gradual muscle rupture and fistula formation. Although endoscopic internal drainage is usually safe and effective for the management of post-laparoscopic sleeve gastrectomy leaks, close clinical and radiological follow-up is mandatory.
Jad AbiMansour;Veeravich Jaruvongvanich;Saran Velaga;Ryan Law;Andrew C. Storm;Mark Topazian;Michael J. Levy;Ryan Alexander;Eric J. Vargas;Aliana Bofill-Garica;John A. Martin;Bret T. Petersen;Barham K. Abu Dayyeh;Vinay Chandrasekhara
Clinical Endoscopy
/
제57권5호
/
pp.595-603
/
2024
Background/Aims: Coaxial placement of double pigtail plastic stents (DPPS) through lumen-apposing metal stents (LAMSs) is commonly performed to reduce the risk of LAMS obstruction, bleeding, and stent migration when used for the drainage of pancreatic fluid collections (PFCs). A systematic review and meta-analysis were performed to compare the outcomes of LAMS alone and LAMS with coaxial DPPS placement in the management of PFCs. Methods: A systematic review was conducted to identify studies comparing LAMS and LAMS/DPPS for PFC drainage. Primary outcomes included the rate of clinical success, overall adverse events (AEs), bleeding, infection, occlusion, and stent migration. The pooled effect size was summarized using a random-effects model and compared between LAMS and LAMS/DPPS by calculating odds ratios (ORs). Results: Nine studies involving 709 patients were identified (338 on LAMS and 371 on LAMS/DPPS). LAMS/DPPS was associated with a reduced risk of stent obstruction (OR, 0.59; p=0.004) and infection (OR, 0.55; p=0.001). No significant differences were observed in clinical success (OR, 0.96; p=0.440), overall AEs (OR, 0.57; p=0.060), bleeding (OR, 0.61; p=0.120), or stent migration (OR, 1.03; p=0.480). Conclusions: Coaxial DPPS for LAMS drainage of PFCs is associated with a reduced risk of stent occlusion and infection; however, no difference was observed in the overall AE rates or bleeding.
Purpose : The purpose of this study is to develop a surgical stent for dental implant procedure that can be easily applied and affordable by using cone beam computerized tomography (CBCT). Materials and Methods : Aluminum, Teflon-PFA (perfluoroalkoxy), and acetal (polyoxymethylene plastic) were selected as materials for the surgical stent. Among these three materials, the appropriate material was chosen using the CBCT images. The surgical stent, which could be easily placed into an oral cavity, was designed with chosen material. CBCT images of the new surgical stent on mandible were obtained using Alphard-3030 dental CT system (Asahi Roentgen Co., Ltd., Kyoto, Japan). The point of insertion was prescribed on the surgical stent with the multiplanar reconstruction software of OnDemand3D (CyberMed Inc., Seoul, Korea). Guide holes were made at the point of insertion on the surgical stent using newly designed guide jig. CBCT scans was taken for the second time to verify the accuracy of the newly designed surgical stent. Results : Teflon-PFA showed radiologically excellent image characteristics for the surgical stent. High accuracy and reproducibility of implantation were confirmed with the surgical stent. Conclusion : The newly designed surgical stent can lead to the accurate implantation and achieve the clinically predictable result.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.