• Title/Summary/Keyword: Plastic film type

Search Result 104, Processing Time 0.023 seconds

Experimental and Analytical Study on High Stress of Tensile Membrane Structures by Stretch Fabrication Using ETFE Film (ETFE필름의 연신성형에 의한 장력막구조의 고내력화 실험 및 해석적 연구)

  • Jeong, Eul-Seok;Kawabata, Masaya;Kim, Seung-Deog
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.3
    • /
    • pp.85-92
    • /
    • 2014
  • Most of the structural forms in which ETFE film is used are the cushion(pneumatic membrane structures) and tension type(tensile membrane structures), which have been generally accepted to be the most efficient forms. Tensile membrane structures are pulled outward from the exterior to introduce initial stress. And such structures offer the advantage of a natural shape formed by tensile stress and eliminate the need for blast air. Recently, the number of tension type structures is increasing. However, there are problems of creep and relaxation of ETFE films under long-term stresses. In this paper, the stretch fabrication method is proposed for stretching the film into the plastic region during initial tensioning as a way to increase its strength. And its effectiveness is confirmed by investigating experimental and analytical test using ETFE films.

Development of Thermal Storage System in Plastic Greenhouse (I) -Development of Air-Water Heat Exchange System- (플라스틱 온실(溫室)의 열저장(熱貯藏) 시스템 개발(開發)에 관(關)한 연구(硏究)(I) -수막식(水膜式) 열교환(熱交換) 시스템의 개발(開發)-)

  • Kim, Y.H.;Koh, H.K.;Kim, M.K.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.1
    • /
    • pp.14-22
    • /
    • 1990
  • For efficient use of solar energy in plastic greenhouse, thermal storage system was developed. The system was constructed with the counter-flow type air-water heat exchanger using a thin polyethylene film as a medium of heat exchange parts. Experiments were carried out to investigate the heat exchange rate, optimum water flow rate, overall heat transfer coefficient, and the effectiveness of the counter-flow type air-water heat exchanger with polyethylene film bags. Mathematical model to predict air temperature leaving heat exchanger was developed. The results obtained in the present study are summarized as follows. 1. Heat exchange rate in the counter-flow type air-water heat exchanger with polyethylene film bags was compared to that of polyethylene film. Heat exchange rate was almost identical at air velocity of 0.5m/s on polyethylene film surface. But, heat exchange rate of heat exchanger with polyethylene film bag was $32{\sim}55KJ/m^2$ hr higher than that of polyethylene film at air velocity of 1.0m/s. 2. Considering the formation of uniform water film and the sufficient heat exchange rate of polyethylene film bags, optimum water flow rate in polyethylene film bags was $3.0{\sim}6.0{\ell}/m^2$ min. 3. The overall heat transfer coefficient of polyethylene film bags was found to be $35.0{\sim}130.0KJ/m^2\;hr\;^{\circ}C$ corresponding to the air velocity ranging 0.5 to 4.0 m/s on polyethylene film surface. And the overall heat transfer coefficient showed almost linearly increasing tendency to the variation of air velocity. 4. Mathematical model to predict air temperature leaving the heat exchanger was developed, resulting in a good agreement between the experimental and predicted values. But, the experimental results were a little lower than predicted. 5. Effectiveness of heat exchanger for the experiment was found to be 0.40~0.81 corresponding to the number of transfer units due to the variation of air velocity ranging 0.6 to 1.7 m/s.

  • PDF

Study about high temperature operating test result For Thin Film-Transistor Electro Phoretic Display on plastic

  • Kim, Sun-Young;Lee, Woo-Jae;Yi, Jun-Sin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.962-964
    • /
    • 2007
  • A 14.1-inch reflective type Thin Film Transistor-Electric Phoretic Display was developed at the esolution of 1280 x 900 lines on plastic substrate. All of the processes of TFT were carried out below $100\;^{\circ}C$ on PES plastic films. The process conditions of TFT were optimized for large area TFT-LCD on plastic substrate. At $60^{\circ}C$ high temperature during 160hours, TFT does not delaminate and IV characteristic is also satisfied.

  • PDF

An Experimental Study on the Performance of a Cross-Flow-Type, Indirect Evaporative Cooler Made of Paper/Plastic Film (종이와 플라스틱 필름의 이종 재질로 구성된 직교류형 간접증발소자의 성능에 대한 실험적 연구)

  • Kwon, Mi-Hye;Go, Min-Geon;Kim, Nae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.475-483
    • /
    • 2015
  • In Korea, a typically hot and humid summer means that air-conditioners consume a large quantity of electricity; accordingly, the simultaneous usage of an indirect evaporative cooler may reduce the sensible-heat level and save the amount of electricity that is consumed. In this study, the heat-transfer and pressure-drop characteristics of an indirect evaporative cooler made of paper/plastic film were investigated under both dry and wet conditions; for the purpose of comparison, an indirect evaporative cooler made of plastic film was also tested. Our results show that the indirect evaporative efficiencies under a wet condition are greater than those under a dry condition, and the efficiencies of the paper/plastic sample (109% to 138%) are greater than those (67% to 89%) of the plastic sample; in addition, the wet-surface, indirect evaporative efficiencies of the paper/plastic sample are 32% to 36% greater than those of the plastic sample. Further, the wet-surface pressure drops of the paper/plastic sample are 13% to 23% larger than those of the plastic sample, and this might have been caused by the surface roughness of the samples. A rigorous heat-transfer analysis revealed that, for the plastic sample, 30% to 37% of the wet channels remained dry, whereas all of the channels were wet for the paper/plastic sample.

Prevention of thin film failures for 5.0-inch TFT arrays on plastic substrates

  • Seo, Jong-Hyun;Jeon, Hyung-Il;Nikulin, Ivan;Lee, Woo-Jae;Rho, Soo-Guy;Hong, Wang-Su;Kim, Sang-Il;Hong, Munpyo;Chung, Kyuha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.700-702
    • /
    • 2005
  • A 5.0-inch transmissive type plastic TFT arrays were successfully fabricated on a plastic substrate at the resolution of $400{\times}3{\times}300$ lines (100ppi). All of the TFT processes were carried out below $150^{\circ}C$ on PES plastic films. After thin film deposition using PECVD, thin film failures such as film delamination and cracking often occurred. For successful growth of thin films (about 1um) without their failures, it is necessary to solve the critical problem related to the internal compressive stress (some GPa) leading to delamination at a threshold thickness value of the films. The Griffith's theory explains the failure process by looking at the excess of elastic energy inside the film, which overcomes the cohesive energy between film and substrate. To increase the above mentioned threshold thickness value there are two possibilities: (i) the improvement of the interface adhesion (for example, through surface micro-roughening and/or surface activation), and (ii) the reduction of the internal stress. In this work, reducing a-Si layer film thickness and optimizing a barrier SiNx layer have produced stable CVD films at 150oC, over PES substrates

  • PDF

Fabrication of Flexible Thin Film Diode Devices for Plastics film LCO (플라스틱 필름 LCD용 연성 박막 다이오드 소자 제작)

  • 이찬재;홍성제;한정인;김원근
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.218-221
    • /
    • 2002
  • We have successfully developed the high performance flexible thin film diode device for flexible plastic film LCD. For flexible LCD, TFD device must be normally operated under any deformation state. Two type devices, Ti/Ta$_2$O$\sub$5//Ta and Al/Ta$_2$O$\sub$5//Al were fabricated and the symmetry and reliability of those were estimated under various measurement conditions including severely bending states.

  • PDF

A STUDY OF INTERFACE AND CORROSION BEHAVIOR BETWEEN IMPLANT ABUTMENT AND CASTING GOLD ALLOY (임플랜트 지대주와 주조 금합금과의 접합 및 부식에 관한 연구)

  • Son, Mee-Kyoung;Ma, Jang-Seon;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.672-686
    • /
    • 1999
  • The purpose of this study was to compare the casting problem and corrosion behavior in two types of HL Hexed abutments of the Steri-Oss system ; gold/plastic coping and gold coping. The anodic Polarization behavior, the galvanic corrosion between abutments and Type III gold alloys, before and after casting were analyzed, and the crevice corrosion of casting samples was analyzed with the CPPT test and the SEM. The results are as follows : 1. Anodic polarization behavior of samples ; Before casting, gold/plastic coping and gold coping was shown to have a similar corrosion pat-terns. Type III casting gold alloy was shown to have a lower corrosion potential and passivation film. Corrosion potential of the case of gold/plastic coping after casting was higher than that of gold coping, but the region of passivation film for gold/plastic coping was smaller than that of gold coping. 2. Galvanic corrosion behavior of samples ; Contact current density between casting gold alloys and gold/plastic before casting was higher than that between gold coping and casting gold alloy Galvanic corrosion of samples after casting was shown to have similar contact current density 3. Crevice corrosion behavior of samples ; Crevice corrosion resistance of casting sample using gold coping was lower than that of cast-ing sample using gold/plastic coping, and a severe corrosion pattern was observed at the abutment-casting gold alloy interface by the SEM.

  • PDF

Image of Plastic Surgeons and Plastic Surgery Illustrated in Korean Movies and TV Dramas (한국 영화와 드라마에 나타난 성형외과 의사와 성형수술의 이미지)

  • Kim, Han Joon;Hwang, Kun
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.2
    • /
    • pp.95-98
    • /
    • 2012
  • Nowadays, plastic surgical operations are increasingly being performed in Korea. We have gained added interest in this because some professional pictures contain plastic surgery in their venue. In the films, we intend to see the recognition of society for plastic surgeons and which field of plastic surgery. The list of movies for analysis were 'Plastic Beauty (1975)', 'Penthouse Elephant (2005)', '200 Pounds Beauty (2006)', 'Cinderella (2006)', and 'Time (2006)'. The TV dramas were 'She is looking (2005)', 'Lovers (2006-2007)', and 'Before & After Plastic Surgery Clinic (2008)'. Films were analyzed according to the following: the chief complaints and names of the operations, character of plastic surgeons, result of the operation and its possibility in reality, and its effect of plastic surgery on the life of the patients. Most of the film contained facial transplantation or the change of the face or body different from the original shape. Character type of the plastic surgeons was mostly medical realism, rather than ideal humanism. Most of the plastic surgeons have capability as a doctor; however, some of them had extramarital affairs. The surgery was successful in most of the cases, but were the patients happy with the results? This was not the case in the movies. In only one movie, '200 Pounds Beauty', the patient became happy; rest of them were eminently unhappy with the outcome. Why the discrepancy? It is difficult to analyze the minds of the people in the films, but considering that the majority of the characters in the films were rather unsavory, one may deduce that a crooked mind functions differently. Perhaps it is too much to hope for a day that will come when we will see a film that portrays the mental anguish that accompanies each and every procedure the Korean plastic surgeons make.

Preparation of a thin film type of plastic scintillation detector for beta-ray detection (얇은 필름 형태의 베타선 측정용 플라스틱 섬광검출기 제조)

  • Seo, Bum-Kyoung;Kim, Gye-Hong;Woo, Zu-Hee;Oh, Won-Zin;Lee, Kune-Woo;Han, Myeong-Jin
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.495-499
    • /
    • 2005
  • Notwithstanding antipathies against radiation, radiations are extensively used in various fields with development of the radiation technology. In order to safely manage such radiation it is necessary for development of the radiation measurement materials. In this paper a thin film type of plastic scintillator using in the contamination measurement devices was prepared. The plastic organic scintillator was prepared by simple solvent methods. It was possible to prepare in easy way and in various forms. The polysulfone which has high transparency and solubility was chosen. As the radiation measurement scintillator, the optical properties and radiation detection abilities were estimated.

An Experimental Study on Biaxial Tensile Characteristics of ETFE Film and Stress Relaxation of Tension Typed Membrane Structures (ETFE 필름의 2축 인장특성 및 텐션방식 막구조물의 응력완화 거동에 관한 실험적 연구)

  • Kim, Seung-Deog;Jeong, Eul-Seok;Kawabata, Masaya
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.1
    • /
    • pp.35-42
    • /
    • 2016
  • Until recently, almost all ETFE film structures that have been erected is the cushion type because there are problems at lower allowable strength under elastic range and viscosity behaviour such as creep and relaxation of ETFE films under long-term stresses. But the number of tension type structures is currently increasing. This paper proposes the stretch fabrication of ETFE film to verify the applicability of ETFE films to tensile membrane structures. First of all, to investigate the possibility of application on tensile membrane structures, the stretch fabrication test is carried out, and it is verified that it is possible to increase the yield strength of the film membrane structures. After simulating the experiment also carries out an analytical investigation, and the effectiveness of the elasto-plastic analysis considering the viscous behavior of the film is investigated. Finally, post-aging tension measurement is conducted at the experimental facilities, and the viscosity behavior resulting from relaxation is investigated with respect to tensile membrane structures.