• Title/Summary/Keyword: Plastic damage

Search Result 824, Processing Time 0.036 seconds

Impact Damage on Brittle Materials with Small Spheres (I) (취성재료의 소구충돌에 의한 충격손상 (I))

  • U, Su-Chang;Kim, Mun-Saeng;Sin, Hyeong-Seop;Lee, Hyeon-Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.11
    • /
    • pp.93-100
    • /
    • 2001
  • Brittle materials are very weak for impact because of typical characteristics which happen to be easily fractured with low fracture toughness and crack sensitivity. When brittle materials are subjected to impact due to small spheres, high contact pressure is occurred to impact surface and then local damage on specimen is developed, since there are little plastic deformations due to contact pressure compared to metals. This local damage is a dangerous factor which gives rise to final fracture of structures. In this research, the crack propagation process of soda lime glass by impact of small sphere is explained and the effects of the constraint conditions of impact spheres and materials for the material damage were studied by using soda-lime glass. that is the effects for the materials and sizes of impact ball, thickness of specimen and residual strength. Especially, this research has focused on the damage behavior of ring crack, cone crack and several kinds of cracks.

  • PDF

Investigations on Inundation Damage in Greenhouse Complex Established at Lowlands on the Geumgang Riverside (금강변 저지대 시설원예단지의 침수피해 실태와 개선방안 조사연구)

  • Nam, Sang-Woon;Kim, Tae-Cheol;Kim, Dae-Sik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.3
    • /
    • pp.47-55
    • /
    • 2010
  • Investigations on the inundation damage and improvement measures were carried out centering around the protected horticultural complex concentrated in lowlands on the side of Geum river, in Nonsan and Buyeo, Chungnam. Most greenhouses were single-span plastic houses in this area, and tomato, strawberry and watermelon were cultivated mainly. 45.8 % of whole farmhouse were experienced in damage by inundation, and a frequency of the damage was average once in 11 years. The most urgent problem at the greenhouse culture in this area was showed in order of drainage improvement, irrigation water resources and energy saving. Consideration items in drainage improvement project for protected horticulture were showed in order of extending drain pumps, extending drain canals, using concrete flume in drain ditch. It needs to consider systematic plans that can restrain new establishment of greenhouses on the lowland paddy field in drainage area. It is difficult to remove greenhouses which are already established or prohibit cultivation. Therefore we should impose minimum duty items so that greenhouse tillers can cope with inundation. And it is thought that managing agency need to minimize farmers damage by improving drainage ability and introducing maintenance pattern that is different from rice cropping.

Modeling of time-varying stress in concrete under axial loading and sulfate attack

  • Yin, Guang-Ji;Zuo, Xiao-Bao;Tang, Yu-Juan;Ayinde, Olawale;Ding, Dong-Nan
    • Computers and Concrete
    • /
    • v.19 no.2
    • /
    • pp.143-152
    • /
    • 2017
  • This paper has numerically investigated the changes of loading-induced stress in concrete with the corrosion time in the sulfate-containing environment. Firstly, based on Fick's law and reaction kinetics, a diffusion-reaction equation of sulfate ion in concrete is proposed, and it is numerically solved to obtain the spatial and temporal distribution of sulfate ion concentration in concrete by the finite difference method. Secondly, by fitting the existed experimental data of concrete in sodium sulfate solutions, the chemical damage of concrete associated with sulfate ion concentration and corrosion time is quantitatively presented. Thirdly, depending on the plastic-damage mechanics, while considering the influence of sulfate attack on concrete properties, a simplified chemo-mechanical damage model, with stress-based plasticity and strain-driven damage, for concrete under axial loading and sulfate attack is determined by introducing the chemical damage degree. Finally, an axially compressed concrete prism immersed into the sodium sulfate solution is regarded as an object to investigate the time-varying stress in concrete subjected to the couplings of axial loading and sulfate attack.

Usefulness of Venous Graft in Hand Injury (수부 손상에서 정맥이식의 유용성)

  • Lee, Hak-Sung;Kim, Youn-Hwan;Kim, Chang-Yeon;Kim, Jeong-Tae;Ahn, Hee-Chang
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.396-399
    • /
    • 2010
  • Purpose: In hand injury, pedicle is usually damaged by avulsion injury or crushing injury. Because of postoperative pedicle obliteration, it is often hard to save the injured hand and fingers, even after successful replantation. The author introduces three cases of extensive hand injury, and successful results after applicatoin of multiple venous grafts to these patients. Methods: In all cases there was no circulation in any finger. In the first case, some vessels were extracted, so venous graft was applied to two sites of severely damaged venous sites. In the second case, venous grafts were applied to all four digital arteries of all fingers except thumb which got severely crushed, and two sites of dorsal veins. In the third case, venous graft was applied to all four digital arteries of all five fingers, and two sites of dorsal veins and palmar veins each. Results: In all cases, survival of hands and fingers was successful. In the second case, however, amputation in thumb and little finger at DIP joint level was inevitable, because of its severe damage, and the large dorsal defect on index finger was filled with DIEP free flap. Thumb was reconstructed with toe-to-thumb free flap, and additional debulking procedures and contracture release is furtherly needed. In the first case, additional surgery was done, as FDP tendon got re-ruptured, but in long term follow-up, satisfactory range of motion was attained. In the third case, FTSG on dorsal skin region was planned. as flap on dorsal area got partial necrosis. Conclusion: In hand injury, there are many structures to be repaired, but sometimes venous graft is avoided for its long operating time. Even though the length of damaged vessel is enough for anastomosis, the endothelium is often damaged (zone of injury). In extensive hand injury, successful reconstruction would be possible with active venous graft to all vessels suspicious for damage.

Analysis on Usefulness of Various Free Flaps for Primary Reconstruction on Fourth Degree Burn (4도 화상에서 다양한 유리피판술을 이용한 1차 재건 방법의 유용성 고찰)

  • Lee, Ju Ho;Shin, Se Ho;Kim, Hyeon Jo;Lee, Seong Joo;Kim, Seong Hwan;Suh, In Suck;Kim, Jae Hyun
    • Journal of the Korean Burn Society
    • /
    • v.23 no.2
    • /
    • pp.54-59
    • /
    • 2020
  • Purpose: A fourth degree burn is a full-thickness burn of the skin usually accompanied by damage to deep structures and commonly results in extensive damage to surrounding tissues which makes the treatment of the wound difficult. Coverage of these wound using free flap is known to effective but not commonly used. The purpose of our study is to review our experience and suggest early application of free flap surgery. Methods: A retrospective review was performed from 2010 to 2019, on a total of 34 fourth degree burn patients undergone free flap surgery as primary treatment in our hospital. We reviewed the location of the injury, etiology, TBSA (%), Presence of osteomyelitis, flap choice, complications, period of injury to surgery and healing. Results: Using free flap as a primary reconstrcuction, the outcome is satisfactory. The treatment period was shortened, and there was less loss of function due to complications. Also the incidence of osteomyelitis and amputation was significantly low. Conclusion: Applying free flap surgery as soon as possible in fourth degree burns is effective, such as reducing complications such as infection, reducing amputation, shortening treatment period, and preventing severe sequelae.

Evaluation Method of Plastic Pipe for High-Strength Water Supply (고강도 수도용 PVC관의 성능평가 연구)

  • Park, Jong-II;Lee, Chang Suck
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.1
    • /
    • pp.44-49
    • /
    • 2018
  • High-strength plastic water supply pipe evaluation method was evaluated in this study. Up to date, high strength water supply pipes that we install are mostly ductile cast iron pipes. Sometimes, a few PVC pipes are installed. Metal pipes have rust problem on the surface, causing serious damage to metal pipes and reducing the expected life span of water piping system. Nowadays, depending on technology development, some companies have improved properties of general PVC pipe performance with remarkable properties that exceed KS and ASTM standard. Here, we suggest a new method of performance evaluation for high-strength water plastic pipes.

Effect of Elastic/Plastic Mismatch on the Contact Crack Initiation in Asymmetric Layered Composite (층상형 비대칭성 복합재료의 탄성/소성 불일치가 접촉 균열의 개시에 미치는 영향)

  • Kim, Sang-Kyum;Lee, Kee-Sung
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.195-198
    • /
    • 2005
  • The role of elastic/plastic mismatch on the contact crack initiation is investigated for designing desirable surface-coated asymmetric layered composites. Various layered composites such as $Si_3N_4$ ceramics on $Si_3N_4+BN$ composite, soda-lime glass on various substrates with different elastic modulus for the analysis. Spherical indentation is conducted for producing contact cracks from the surface or interface between the coating and the substrate layer. A finite element analysis of the stress fields in the loaded layer composites enables a direct correlation between the damage patterns and the stress distributions. Implications of these conclusions concerning the design of asymmetric layered composites indicate that the elastic modulus mismatch is one of the important parameter for designing layered composite to prevent the initiation of contact cracks.

  • PDF

Discussion: Use of the Fix and Flap Approach to Complex Open Elbow Injury: The Role of the Free Anterolateral Thigh Flap

  • Zhang, Yixin
    • Archives of Plastic Surgery
    • /
    • v.39 no.2
    • /
    • pp.137-137
    • /
    • 2012
  • Fast improvements in microsurgery have opened new strategies in the field of reconstructive trauma surgery that can be applied to severe elbow trauma management. The disadvantages of pedicle flaps can be overcome in the hand of an experienced trauma surgeon by using free flaps based on the perforators. This provides the patient with the best possible wound cover within the optimal time frame and the treatment of underlying additional structural damage. Although the authors presented only a small number of cases, the results of this study are promising and encourage the use of the ALT flap for the treatment of severe elbow trauma.

Injection Mold with Cavity Pressure/Temperature Sensors for Standard Tensile Test Specimen (내압력.온도센서를 갖는 표준 인장시편용 사출금형)

  • Lee, Do-Myoung;Han, Byoung-Kee;Lee, Sung-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.11
    • /
    • pp.84-90
    • /
    • 2007
  • In this study, design and manufacturing of plastic injection mold with cavity pressure/temperature sensors were performed fur tensile test specimen. International standard system for plastic tensile specimen was applied to design an injection molding system. Cavity pressure and temperature sensors were placed on the side of fixed platen of the injection mold to prevent them from external impact damage. Injection molding experiments with variations of injection speed and melt temperature were performed and then tensile test of the manufactured polycarbonate specimens was also performed. It was shown that injection molding processing parameters can have effect on the mechanical properties of the plastic injection molded part.

Groundwater and Soil Environment of Plastic Film House Fields around Middle Korea (우리나라 중부지방 시설원예지 토양 및 지하수 환경)

  • Kim, Jin-Ho;Ryu, Jong-Soo;Kwun, Soon-Kuk
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.479-483
    • /
    • 2001
  • This Study was carried out to know the soil properties and the quality of shallow groundwater in the plastic film house fields around mid-Korea. This study was conducted at 11 sites in Suweon, Pyungtaek, Yongin, and Chunchen on May, June, July and August in 1999. The the average concentration of nitrate-nitrogen was 19.1 mg/L, it reached almost to the limiting level, 20 mg/L. Moreover about 36.4% of survey sites exceeded limiting level to agricultural groundwater quality. And Sulfur concentrations also at some sites exceeded to agricultural groundwater quality limit level (50 mg/L), which could make damage to the crop. Nitrate-nitrogen, which is one of the most important factors in the groundwater quality, It has highly positive correlation with any other ion in groundwater. This result showed that groundwater quality management practices should be taken for the agricultural production as well as for environment at the plastic film house areas.

  • PDF