• Title/Summary/Keyword: Plastic artifacts

Search Result 10, Processing Time 0.022 seconds

Study on the Basic Survey and Materials Properties for Conservation of Plastic Artifacts: 'A Bag of Alice - a Fish without Eyes' (플라스틱 작품의 기초조사 및 보존처리 재료 연구: 이인희 '앨리스의 가방 - 눈 없는 물고기'를 중심으로)

  • Han, Ye Bin;Kim, Jung Heum;Beom, Dae Geon
    • Journal of Conservation Science
    • /
    • v.34 no.5
    • /
    • pp.379-385
    • /
    • 2018
  • This study examined the condition of degraded plastic artifacts and conducted materials assessments for conservation treatment. The properties and bond characteristics of five types of adhesives(EVA, PVAc, Cyanoacrylate) were evaluated to select the adhesive most suitable for conservation treatment. The degradation of plastic artifacts caused cracks, peelings, and surface warping. According to the FT-IR analysis, the synthetic resin used in the artifact was estimated to EVA type. The properties of the adhesives were evaluated through acidity, and hardness measurements. The results showed that acidity varies with the type of adhesive, and that the hardness of PVAc was higher than those of EVA. On comparing the bond characteristics of the samples after artificial degradation, it was found that PVAc and Cyanoacrylate increased the chromaticity and hardness of the samples, while EVA was the most stable with relatively little change. Thus, EVA was confirmed to be the most suitable materials for conservation treatment of degraded plastic artifacts. In this study, as the experiment of treatment materials based on actual artifact, it is expected that it could be used a basis research for conservation treatment of plastic artifacts.

Gold-wire artifacts on diagnostic radiographs: A case report

  • Keestra, Johan Anton Jochum;Jacobs, Reinhilde;Quirynen, Marc
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.81-84
    • /
    • 2014
  • This report described a case in which diagnostic radiographs showed irregular dense radiopaque strings and curved lines in the head and neck area. These artifacts could lead to misinterpretation since they may obscure anatomical structures and/or mask critical structures/pathologies. A more detailed history of the patient indicated that these strings originated from a facelift procedure in which a gold-wire technique was used. Considering that such intervention may cause a radiodiagnostic burden, it should be included in the anamnesis prior to radiography.

Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model

  • Dae Joong Kim;Kun Hwang;Hun Kim;Jang Gyu Cha;Hyungseok Jang;Ju-Yong Park;Yeo Ju Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.782-791
    • /
    • 2021
  • Objective: To evaluate the signal intensity of the periosteum using ultrashort echo time pulse sequence with three-dimensional cone trajectory (3D UTE) with or without fat suppression (FS) to distinguish from artifacts in porcine tibias. Materials and Methods: The periosteum and overlying soft tissue of three porcine lower legs were partially peeled away from the tibial cortex. Another porcine tibia was prepared as three segments: with an intact periosteum outer and inner layer, with an intact periosteum inner layer, and without periosteum. Axial T1 weighted sequence (T1 WI) and 3D UTE (FS) were performed. Another porcine tibia without periosteum was prepared and subjected to 3D UTE (FS) and T1 WI twice, with positional changes. Two radiologists analyzed images to reach a consensus. Results: The three periosteal tissues that were partially peeled away from the cortex showed a high signal in 3D UTE (FS) and low signal on T1 WI. 3D UTE (FS) showed a high signal around the cortical surface with an intact outer and inner periosteum, and subtle high signals, mainly around the upper cortical surfaces with the inner layer of the periosteum and without periosteum. T1 WI showed no signal around the cortical surfaces, regardless of the periosteum state. The porcine tibia without periosteum showed changes in the high signal area around the cortical surface as the position changed in 3D UTE (FS). No signal was detected around the cortical surface in T1 WI, regardless of the position change. Conclusion: The periosteum showed a high signal in 3D UTE and 3D UTE FS that overlapped with artifacts around the cortical bone.

A study on aging characteristics of epoxy resins for conservation treatment of cultural heritage by adding UV stabilizer (자외선 안정제 첨가에 따른 문화재 보존처리용 에폭시계수지의 노화특성 연구)

  • Jeong, Se-Ri;Cho, Nam-Chul
    • Analytical Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.336-344
    • /
    • 2011
  • The study attempted to find out any effect to prevent photo aging of epoxy resin used for conservation by way of adding UV stabilizer, one of plastic additives. Specimens were made by adding HALS and UVA UV stabilizer as each concentration to 3 kinds of epoxy resin, which are most frequently used for artifacts joining and restoration process, and aging effects were investigated through Color change, SEM, contact angle, FTIR analysis during UV aging experiments. Last, usage suitability was checked when UV stabilizer was added through Universal Tensile strength tester. In result, it is impossible to prevent decomposition of chemical structure in spite of adding UV stabilizer but in the case of epoxy A and R, it is believed that photo aging such as yellowing or crack can be minimized without giving a big influence to adhesive strength of epoxy resin through adding less than 0.1% of UVA. It is expected that above will solve photo aging problem of epoxy resin used for joining and restoration of artifacts and will extend its life as joining and restoration materials.

Preservation Values and Effects on Cleaning and Adhesive Agents for Plastic Artifacts (플라스틱 작품의 보존 가치 및 세척제와 접착제의 효능 평가)

  • Chung, Yong Jae;Yu, Ji A;Kang, Dai Ill
    • Journal of Conservation Science
    • /
    • v.29 no.2
    • /
    • pp.127-138
    • /
    • 2013
  • Plastic, widely used as a material for contemporary art, get damaged as directly exposed to temperature, humidity, ultra violet, etc. And it is very quickly damaged in early time, once damaged, it can't recover into original state. But like this characteristics, there is a few advanced research in Korea. So this study deal with a rising value of plastic artifacts in other country, United Kingdom and France, current conservation state, identification and cleaning method. Also 5 types of cleaners(distilled water, ethanol, acetone, eraser) and adhesives(cyanoacrylate, epoxy, acrylic, chloroprene rubber) were evaluated by produced plastics(PVC, PE, PP, PS, PU). As a result of experiment, ethanol and acetone that were previous evaluated in other research performed in other country are the best cleaner. Result of degradation after adhesive, cyanoacrylate and epoxy resin showed better performance and stability. As a basic research, this study is expected that can be used in future researches.

CT Number Measurement of Residual Foreign Bodies in Face (안면부에 잔류된 다양한 이물질을 측정한 CT 계수)

  • Wee, Syeo Young;Choi, Hwan Jun;Kim, Mi Sun;Choi, Chang Yong
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.423-430
    • /
    • 2008
  • Purpose: Computed tomography theoretically should improve detection of foreign bodies and provide more information of adjacent soft tissues. And the CT scanner and PACS program proved to be an excellent instrument for detection and localization of most facial foreign bodies above certain minimum levels of detectability. The severity of injury in penetrating trauma to the face, it is often underestimated by physical examination. Diagnosis of a retained foreign object is always critical. Methods: From March, 2005 to February 2008 a study was done with 200 patients who had facial trauma. Axial and coronal CT images were obtained with a General Electric(Milwaukee, Wis) 9800 CT scanner at 130 kV, 90 mA, with a 2-mm section thickness and a $512{\times}512$ matrix. Results: Axial and coronal CT images at various window widths should be used as the first imaging modality to detect facial foreign bodies. The attenuation coefficients for the metallic and nonmetallic foreign bodies ranged from -437 to +3071 HU. As a general rule, metallic foreign bodies produced more Hounsfield artifacts than nonmetallic foreign bodies, thus providing a clue to their composition. All of the metallic foreign bodies were represented by a single peak and had a maximum attenuation coefficient of +3071 HU. Of the nonmetallic foreign bodies, glass had an attenuation coefficient that ranged from +105 to +2039, while plastic had a much lower coefficient that ranged from -62 to -35. wood had the lowest range of attenuation coefficients: -491 to -437. Conclusion: The PACS program allows one to distinguish metallic from nonmetallic foreign bodies and to individually identify the specific composition of many nonmetallic foreign bodies. This program does not, however, allow identification of the specific composition of a metallic foreign body. We recommend this type of software program for CT scanning of any patient with an injury to the face in which a foreign body is suspected.

Determination of Phthalates Compounds in the Ambient Atmosphere (II) - Evaluation of Experimental Artifacts and Sample Clean-up Procedures - (환경대기 중 프탈레이트 화합물의 농도 측정 (II) - 실험재료 전처리 및 시료정제과정 평가 -)

  • Park, Young-Hwa;Hwang, Yoon-Jung;Seo, Young-Kyo;Baek, Sung-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.455-460
    • /
    • 2010
  • This study was carried out to find out any inherent problems occurring in the sampling and analytical procedures, and to suggest the relevant solutions to the problems. In addition, an optimal condition of clean-up process was developed, which was based on a method using silica glass column. As a result of experiments to test any artificial contamination of blank samples such as glassware and collection media, artifacts of DBP and DEHP appeared to be detected in various kinds of laboratory tools and apparatuses used in the sampling and analytical works. Therefore, it is necessary to investigate a degree of contamination before laboratory works by conducting a prior check any possible contaminations in all experimental tools and apparatus. It is also necessary to devise a method to avoid a tool, if possible, or to use a substitute of phthalate free. If the use of any plastic tool to cause contamination is inevitable, it should be properly corrected with a blank level, as is equally treated as the sample. The clean-up process demonstrated in this study can give us a significant benefit in terms of the quantity and quality of a target compound by GC/MS analysis.

Evaluation of image quality for metal artifact using protocol parameters in the MRI (자기공명영상에서 프로토콜 변화를 이용한 금속인공물의 영상평가)

  • Lee, Su-Hyun;Kim, Do-Gyoung;Kim, Yo-Han;Yeum, Hyei-Jeong;Lee, Heon-Jun;Lim, Ju-Yeon;Choi, Woo-Jeon;Kim, Dong-hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.582-585
    • /
    • 2015
  • In the aging society, TKRA is steadily increased because of joint diseases. Artificial joint used in TKRA generates metal artifacts in the MRI. Metal artifact may affect diagnosis. In study, We are going to minimize the effect of metal artifact to improve the value of diagnosis by changing the sequence and the type of artificial joint(Co-Cr, Ni-Ti). 1.5T AVANTO, plastic containers and each of the artificial joint (Normal, Co-Cr, NiTi) were used. After the artificial joints fixed in a paper cup was inserted in a plastic container of cylindrical, Signal intensity was measured. To obtain strong and uniform signal intensity, the plastic container was filled with water. We changed Sequences(T1 TSE, T2 TSE, PD TSE) and obtained an Axial image. After excepting the maximum and minimum values, We calculated the average of SNR, CNR and PSNR. Consequently, The SNR, CNR value of PD TSE are measured higher than these of T1 TSE, T2 TSE and The PSNR of Co-Cr is higher than this of Ni-Ti. The SNR of Co-Cr is similar to the SNR of normal comparing this of Ni-Ti. As a result, Using sequence of PD Tse and Co-Cr alloy is considered to be useful.

  • PDF

EFFECT OF RHPDGF-BB AND RHBMP-2 ON OSSEOINTEGRATION OF TITANIUM IMPLANTS AT PERIIMPLANT BONE DEFECTS GRAFTED WITH HYDROXYAPATITE: MICRO-CT AND HISTOLOGIC ANALYSIS (Hydroxyapatite를 이식한 임플란트 주위 골결손부에서 rhPDGF-BB와 rhBMP-2가 골내 임플란트 osseointegration에 미치는 영향: Micro-CT 분석과 조직학적 평가)

  • Park, Jee-Hyun;Hwang, Sun-Jung;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.6
    • /
    • pp.461-468
    • /
    • 2009
  • Purpose: Platelet derived growth factor(PDGF)-BB and bone morphogenetic protein(BMP)-2 are well-known representative growth factors. The purposes of this study were to investigate the effect of rhPDGFBB and rhBMP-2 on osseointegration of titanium implants at periimplant bone defects grafted with hydroxyapatite and to evaluate the feasibility of imaging bone structures around screw-type titanium implant with micro-CT. Materials and Methods: The first molar and all premolars in the mandible region of four beagle dogs were extracted. Following a healing period of 4 months, three $8{\times}8{\times}6mm$-sized bony defects were formed and screw-type titanium implants were placed with hydroxyapatite(HA) block and growth factors; Control group, PDGF group and BMP group. Two months post-implantation, the mandible was harvested. Bone volume(BV), bone-to-implant contact(BIC) and bone mineral density(BMD) were analyzed with micro-CT and histology. Results: According to micro-CT analysis, BV and BMD measures of PDGF and BMP group were significantly higher than control group(BV; PDGF group: $p{\fallingdotseq}0.011$, BMP group: $p{\fallingdotseq}0.006$/BMD; PDGF group: $p{\fallingdotseq}0.020$, BMP group: $p{\fallingdotseq}0.011$) and BIC measures of BMP group were significantly higher than PDGF group($p{\fallingdotseq}0.015$). In histologic evaluation, BIC measures of BMP group was significantly higher than PDGF group($p{\fallingdotseq}0.048$). The values of BV in histologic sections were higher than in micro-CT images and the values of BIC in micro-CT images were higher than in histologic sections. Conclusion: The findings of this experimental study indicates that the use of rhPDGF-BB and rhBMP-2 can increase new bone formation in a large bony defect around titanium implant, and rhBMP-2 is more effective than rhPDGF-BB. Micro-CT can be considered useful for assessment as a rapid and nondestructive method for 3-dimensional measurement of bone healing around implants. Further study is necessary, however, to remove metal artifacts around titanium implant and to standardize the method.

The Question of 'State and Art' with regard to Soviet Socialist Realism (소련 사회주의 리얼리즘에 관하여: '국민과 예술'의 문제)

  • Alexander, Morozov
    • The Journal of Art Theory & Practice
    • /
    • no.7
    • /
    • pp.125-163
    • /
    • 2009
  • The artworks of Socialist Realism of the former Soviet Union, with the beginning of the 21st century, are gaining a new attention from art collectors. One reason for this might consist in the fact that relevant art pieces exemplify the ways in which they visualize ideas on the basis of their high-profile art tradition and also in which they integrate their utopian ideals with mysticism. These aspects of the Soviet art goes far beyond the wide-spread assumption that their art, as a means of propaganda, principally represents a political allegiance to the system. With Stalin coming into power in the 1930s, the artistic trend of Socialist Realism obtained a nationwide sympathy and support from people, giving birth to a new art which essentially corresponded to the demands of the political power. An official art current of the USSR over the period from the 1930s to 1950s, Socialist Realism was in tandem with the Communist commitment to the party and popularity, symbolizing a loyalty to the cause. It was thus characterized by plainness and lucidity so that ordinary people could gain easy access to art. Its salient feature, over an entire range of art, was an optimistic pursuit of a utopian dream. Therefore, it tallied with the popular sentiment for a Communist paradise, giving form to their beliefs in human agency working at the materialist world and also to such abstract concepts as force, fitness, and beauty by adding even mythical ideals. Its main subject matter includes harvest feasts of collective farms, imaginary socialist cities, grand marches of heroic laborers and in this way it served as a propaganda for a sacred utopia of socialist totalitarianism. On the other end of the spectrum, however, rose the second camp of art, which put an emphasis on bona-fide artistic activities of plastic art and on an artist's personal expression and freedom, as opposed to the surface optimism of Socialist Realism. Central to the Russian Avant Garde art, which prized the above-mentioned values, were Malevich's Geometric Abstraction and A. Rodchenko's Constructivism. Furthermore, in the transitional era of the late 20th century and the 21st century it was recognized that film art or electronic media art, rather than traditional genre of paintings, would function as a more efficient way of propaganda. These new genres were made possible by ridiculing the stereotypes of the Russian lifestyle and also by ignoring ethical or professional dimensions of artworks. That is, they reinvented themselves into a sort of field art, seemingly degrading the quality of artworks and transforming them into artifacts or simulacres in the very sense of post-modernism. The advent of the new era brought about the formation and occupation of pop culture of the younger generations, calling into question the idea of art as the class-determined. It also increased the attention to field art, which extensively found way to modern art centers, galleries, and exhibition projects. It can be stated that this was a natural outcome of human nature.

  • PDF