• 제목/요약/키워드: Plastic adhesion

검색결과 212건 처리시간 0.022초

Low-Temperature Chemical Sintered TiO2 Photoanodes Based on a Binary Liquid Mixture for Flexible Dye-Sensitized Solar Cells

  • Md. Mahbubur, Rahman;Hyeong Cheol, Kang;Kicheon, Yoo;Jae-Joon, Lee
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권4호
    • /
    • pp.453-461
    • /
    • 2022
  • A chemically sintered and binder-free paste of TiO2 nanoparticles (NPs) was prepared using a binary-liquid mixture of 1-octanol and CCl4. The 1:1 (v/v) complex of CCl4 and 1-octanol easily interacted chemically with the TiO2 NPs and induced the formation of a highly viscous paste. The as-prepared binary-liquid paste (PBL)-based TiO2 film exhibited the complete removal of the binary-liquid and residuals with the subsequent low-temperature sintering (~150℃) and UV-O3 treatment. This facilitated the fabrication of TiO2 photoanodes for flexible dye-sensitized solar cells (f-DSSCs). For comparison purposes, pure 1-octanol-based TiO2 paste (PO) with moderate viscosity was prepared. The PBL-based TiO2 film exhibited strong adhesion and high mechanical stability with the conducting oxide coated glass and plastic substrates compared to the PO-based film. The corresponding low-temperature sintered PBL-based f-DSSC showed a power conversion efficiency (PCE) of 3.5%, while it was 2.0% for PO-based f-DSSC. The PBL-based low- and high-temperature (500℃) sintered glass-based rigid DSSCs exhibited the PCE of 6.0 and 6.3%, respectively, while this value was 7.1% for a 500℃ sintered rigid DSSC based on a commercial (or conventional) paste.

Clinical experience in managing temporomandibular joint ankylosis: five-year appraisal in a Nigerian subpopulation

  • Braimah, Ramat;Taiwo, Abdurrazaq;Ibikunle, Adebayo;Oladejo, Taoreed;Adeyemi, Mike;Adejobi, Francis;Abubakar, Siddiq
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제44권3호
    • /
    • pp.112-119
    • /
    • 2018
  • Objectives: Temporomandibular joint ankylosis (TMJA) is a joint pathology caused by bony and/or fibrous adhesion of the joint apparatus, resulting in partial or total loss of function. Materials and Methods: This is a retrospective study conducted between 2012 and 2016 in the northwest region of Nigeria. The data retrieved includes gender, age, etiology of ankylosis, duration of ankylosis, laterality of ankylosis, type of imaging technique, type of airway management, types of incision, surgical procedure, mouth opening, interpositional materials used, and complications. Results were presented as simple frequencies and descriptive statistics. Results: Thirty-six patients with TMJA were evaluated during the study period. There were 21 males (58.3%) and 15 females (41.7%), yielding a male:female ratio of 1.4:1. The patients' age ranged from 5 to 33 years with $mean{\pm}standard$ deviation ($13.8{\pm}6.6years$). Thirty-five cases (97.2%) were determined to be true/bony ankylosis, while only 1 case (2.8%) was false/fibrous ankylosis. Most of the TMJA cases (16 cases, 44.4%) were secondary to a fall. In our series, the most commonly utilized incision was the Bramley-Al-Kayat (15 cases, 41.7%). The mostly commonly performed procedures were condylectomies and upper ramus ostectomies (12 cases each, 33.3%), while the most commonly used interpositional material was temporalis fascia (14 cases, 38.9%). The complications that developed included 4 cases (11.1%) of severe hemorrhage, 1 case (2.8%) of facial nerve palsy, and 1 case (2.8%) of re-ankylosis. Conclusion: Plain radiographs, with their shortcomings, still have significant roles in investigating TMJA. Aggressive postoperative physiotherapy for a minimum of 6 months is paramount for successful treatment.

잠재지문 현출용 나노 은 분말의 표면개질에 대한 연구 (A study on surface modification of Ag powder for developing latent fingerprints)

  • 김만기;최미정;전충현;박성우
    • 분석과학
    • /
    • 제23권2호
    • /
    • pp.216-223
    • /
    • 2010
  • Ag 분말 입자형태와 크기에 따른 효율성을 확인한 결과 flake, spherical 형태의 분말은 시판 회색 분말과 현출효율이 유사하였고, nAg (rod, $0.9\;{\mu}m$) 분말의 경우 다양한 잠재지문 현출효율 평가 실험에서 우수한 결과를 보였다. 그러나 1개월간 nAg 분말을 자연조건에서 방치하였을 때 분말의 산화 및 수분의 영향으로 현출효율이 낮게 확인되어 산화 및 수분 흡습 방지를 위한 연구가 제기되었다. 본 연구는 nAg 분말의 산화 및 수분 흡습의 단점을 보완하기위해 nAg 분말에 실리콘 오일을 다양한 수준으로 표면개질하여 비다공성 대상물질 표면인 유리, 플라스틱에서 현출지문의 동일한 영역에서 특징점 수, 이랑과 분말의 흡착정도, 현출지문의 contrast 등으로 nAg 분말과 표면개질 nAg 분말의 현출효율을 평가하여 유리, 플라스틱 대상물질에서 DC200 실리콘 오일 0.5%로 표면개질한 nAg 분말의 우수함과 산화 및 수분 흡습의 단점을 보완할 수 있었다.

A STUDY ON THE ADHESION OF A SOFT LINER CONTAINING 4-META TO THE BASE METAL ALLOY AND ITS VISCOELASTIC PROPERTY

  • Park Hyun-Joo;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제41권6호
    • /
    • pp.732-746
    • /
    • 2003
  • Statement of problem. Soft lining materials, also referred to as tissue conditioning materials, tissue heating materials, relining materials, soft liners or tissue conditioners, were first introduced to dentistry by a plastic manufacturer in 1959. Since the introduction of the materials to the dental field, their material properties have been continually improved through the effort of many researchers. Soft lining materials have become widely accepted, particularly by prosthodontists, because of their numerous clinical advantages and ease of manipulation. Unfortunately, few reports have been issued upon the topic of increasing the bond strength between the base metal alloy used in cast denture bases and PMMA soft liner modified with 4-META, nor upon the pattern of debonding and material change in wet environment like a intra oral situation. Purpose. The purposes of this study were comparing the bond strength between base metal alloy used for the cast denture bases and PMMA soft liner modified with 4-META, and describing the pattern of debonding and material property change in wet environment like the intraoral situation. Material and Methods. This study consisted of four experiments: 1. The in vitro measurement of shear bond strength of the adhesive soft liner. 2. The in vitro measurement of shear bond strength of the adhesive soft liner after 2 weeks of aging. 3. A comparison of debonding patterns. 4. An evaluation the Relation time of modified soft liner. The soft liner used in this study was commercially available as Coe-soft (GC America.IL.,USA), which is provided in forms of powder and liquid. This is a PMMA soft liner commonly used in dental clinics. The metal primer used in this study was 4-META containing primer packed in Meta fast denture base resin (Sun Medical Co., Osaka, Japan). The specimens were formed in a single lap joint desist which is useful for evaluating the apparent shear bond strength of adhesively bonded metal plate by tensile loading. Using the $20{\times}20mm$ transparent grid, percent area of adhesive soft liner remaining on the shear area was calculated to classify the debonding patterns. To evaluate the change of the initial flow of the modified adhesive soft liner, the gelation time was measured with an oscillating rheometer (Haake RS150W/ TC50, Haake Co., Germany). It was a stress control and parallel plate type with the diameter of 35mm. Conclusion. Within the conditions and limitations of this study, the following conclusions were drawn as follows. 1. There was significant increase of bond strength in the 5% 4-META, 10% 4-META containing groups and in the primer coated groups versus the control group(P<0.05). 2. After 2 weeks of aging, no significant increase in bond strength was found except for the group containing 10% 4-META (P<0.05). 3. The gelation times of the modified soft liner were 9.3 minutes for the 5% 4-META containing liner and 11.5 minutes for the 10% 4-META liner. 4. The debonding patterns of the 4-META containing group after 2 weeks of aging were similar to those of immediaely after preparation, but the debonding pattern of the primer group showed more adhesive failure after 2 weeks of aging.

공기결합 초음파탐상에 의한 CFRP 복합재의 흡습 특성 평가 (Characterization of Water Absorption by CFRP Using Air-Coupled Ultrasonic Testing)

  • 이주민;이주성;김용권;박익근
    • 비파괴검사학회지
    • /
    • 제34권2호
    • /
    • pp.155-164
    • /
    • 2014
  • 탄소섬유강화 복합재료(carbon fiber reinforced plastics; 이하 CFRP)는 금속재료에 비해 중량이 가벼우면서도 비강도와 비강성이 높은 재료로 항공기, 자동차, 선박 등의 다양한 분야에서 적용이 증가하고 있다. CFRP는 정적부하에 대해서는 우수한 역학적 특성을 가진 반면에 고온 다습한 환경에서는 우수한 역학적 특성을 기대할 수 없고, 복합재료의 유용한 기계적 성질이 장시간 주위 환경에 놓여 있어도 충분히 유지되어야 하지만 온도, 습도 등과 같은 환경적 요인으로 수분이 복합재료 내로 침투하여 기지의 분자 배열 및 화학적 성질을 변화시키고 복합재료의 계면 특성 및 구성 재질의 기계적 성질을 저하시킨다. 항공기의 경우 운항 시에 CFRP가 고온 다습한 환경조건에 장시간 노출되게 되면 CFRP 내부로 수분이 흡수되게 되는데 CFRP 내부에 흡수된 수분은 체적팽창을 야기시키고 내부 응력상태를 변화시킬 뿐만 아니라 섬유와 기지의 화학적 결합을 분리시킴으로써 접합강도를 급격히 저하시키게 된다. 따라서 CFRP를 사용하는 항공기의 구조 건전성 확보를 위하여 실제 환경에서의 특성 변화를 연구할 필요가 있다. 본 연구에서는 공기결합 초음파탐상검사(air coupled ultrasonic testing; 이하 ACUT) 시스템을 이용하여 흡습된 CFRP의 비파괴적 특성을 평가하고자 하였다. CFRP 시험편을 직접 제작한 후 고온다습한 환경을 설정하기 위해 항온수조를 이용하여 $75^{\circ}C$의 증류수에 30일, 60일, 120일간 침지하였고, ACUT를 이용하여 흡습에 의한 CFRP 시험편의 특성 변화를 초음파 C-scan 이미지와 흡습 전과 후의 신호의 전파시간 변화를 통해 초음파 신호 특성 변화를 고찰하였다. 또한 전단강도 평가를 통해 흡습에 의한 기계적 특성 변화를 실험적으로 검증하였다.

기포제 적용 빛 감성 친화형 콘크리트의 휨 특성 예측 모델 (Prediction Model of Flexural Properties of LEFC using Foaming Agent)

  • 김병일;서승훈
    • 한국건축시공학회지
    • /
    • 제19권1호
    • /
    • pp.9-18
    • /
    • 2019
  • 현대에 가장 널리 쓰이는 건축 재료인 콘크리트는 기술의 지속적인 발전에 따라 고강도화 뿐만 아니라 인성 및 연성의 증가, 경량화와 같은 구조적 성능의 향상이 되었다. 또한 인간의 삶의 질이 향상됨에 따라 감성을 충족시킬 수 있는 것에 대한 수요의 급증으로 건축용 외장패널 그리고 건축의 경계를 넘어 인테리어 소품으로까지 다양하게 쓰이는 추세이다. 국내에서는 플라스틱 봉을 삽입하여 빛과 콘크리트의 결합으로 사용자의 감성을 자극하는 빛 감성친화형콘크리트(LEFC)를 개발하였으나, 높은 단위중량으로 인한 현장에서의 시공성 한계를 보여주었다. 이에 본 연구에서는 LEFC에 기포제를 적용하여 단위중량을 감소시켜 경량화를 달성하고 휨 성능 향상을 위해 두 가지 유기섬유(Nylon Fiber, Polyvinyl Alcohol)를 혼입하여 비교분석하였다. 마지막으로 플라스틱 봉 삽입으로 인한 콘크리트 비표면적 손실 및 봉과의 부착력 감소로 인한 휨 강도 변화를 봉의 직경(5mm, 10mm)과 간격(10mm, 15mm, 20mm)에 따른 변수를 적용한 예측 모델을 제안하고자 한다.

복합소재 사출인서트 알루미늄 바 카울크로스멤버 표면처리 특성에 따른 접합강도 분석 연구 (A Study on the Bonding Strength Analysis according to the Surface Treatment Characteristics of Aluminum Bar-Cowl Cross Member of Composite Material Injection Insert)

  • 손동일;소상우;황현태;최동혁;최완규;김선경;김대일
    • Composites Research
    • /
    • 제33권6호
    • /
    • pp.360-364
    • /
    • 2020
  • 차량의 경량화를 위해 기존의 스틸로 제작된 카울크로스멤버를 마그네슘, 플라스틱으로 연구개발이 진행되었으나, 차량 장착상태의 성능적인 문제로 적용이 어려운 실정이다. 최근 부품양산에 가장 적합한 경량화 부품으로 복합소재 인서트 사출 카울크로스멤버에 대한 연구를 진행하고 있다. 이는 알루미늄 바에 복합소재 브라켓 부품을 인서트 사출하는 제조 공정으로 차량의 장착 상태를 고려할 때, 두 부품의 체결상태가 중요한 요소 중에 하나이다. 본 연구에서는, PA6-GF60 복합소재에 알루미늄 바를 인서트 사출하기 위한 연구로 알루미늄 바의 접합강도가 중요한 요소 중에 하나이다. 이를 위한 연구방법으로 알루미늄 바에 접착제를 분사하는 방식과 널링처리를 한 경우에 대해, 카울크로스멤버의 알루미늄 바와 복합재료 사출부품 형상간의 부분 파트별로 횡방향과 회전방향에 대한 접합강도를 분석 연구하였다.

부식 환경 하에서의 섬유강화복합재료의 마찰 및 마모 특성 연구 (A Study on the Frictional Characteristics of Fiber Reinforced Composites under Corrosive Environment)

  • 박충용;박동현;박수정;김윤해
    • Composites Research
    • /
    • 제36권1호
    • /
    • pp.37-41
    • /
    • 2023
  • 선박의 평형수처리장치 전해조 내부 용액은 해수를 전기분해 시 DSA(Dimension Stable Anode) 전극에서 생성되는 수산화물로 인하여 높은 알칼리성 분위기를 생성한다. 본 연구에서는 기존 평형수처리장치 배관에 사용되어지는 PE 코팅 강관 배관의 취약성을 대체 가능한 복합재료로써 4가지 소재를 선정하였으며, 이들 BRE(Basalt fiber reinforced epoxy), BRP(Basalt fiber reinforced unsaturated polyester), GRE(Glass fiber reinforced epoxy), GRP(Glass fiber reinforced unsaturated polyester)를 강 알칼리성 NaOH 용액에 720시간 침지 후 마찰 및 마모 시험을 통하여 재료 마찰 깊이에 따른 마찰계수와 섬유와 수지 간 계면 결합 거동을 분석하였다. 그 결과, 수지와 섬유 간의 게면 분리 현상에 대한 메커니즘을 도출하였다. 또한, 불포화폴리에스테르와 같이 상대적으로 낮은 계면 결합력의 갖는 소재의 경우, 알칼리성 용액에 침지 시간이 길어질수록 표면에서부터 시작된 열화가 내부로 급격하게 확산되어 마찰 계수의 감소로 이어지는 경향을 나타냈다.

폐결핵환자의 폐포대식세포 및 말초혈액내 단구세포에서 분비하는 과산화음이온의 비교 관찰 (Superoxide Generation by Blood Monocyte and Pulmonary Alveolar Macrophage in Patients with Pulmonary Tuberculosis)

  • 송정섭;이숙영;장지정;김영균;김관형;문화식;박성학
    • Tuberculosis and Respiratory Diseases
    • /
    • 제41권1호
    • /
    • pp.11-19
    • /
    • 1994
  • 연구배경 : 결핵균은 facultative intracellular pathogen으로 대식세포에서 생존 번식할 수 있으며, 결핵균이 체내에서 제거되려면 대식세포와 T 임파구에 의한 효과적인 세포매개성 면역반응이 필요하다. 폐포대식세포에 의한 결핵균 살균은 크게 산소의존성 과정과 산소비의존성 과정으로 구분되는데 산소의존성과정은 NADPH oxidase에 의해 산소가 환원반응으로 과산화음이온을 생성하는 과정으로 시작된다. 저자들은 폐결핵환자의 경우 폐포대식세포의 산소유리기 생성의 이상으로 결핵균이 세포내 오래 생존 번식할 것으로 추정하여 폐결핵환자와 대조군에서 폐포대식세포와 말초혈액 단구세포를 분리하여 분비되는 과산화음이온의 양을 비교하여 보았다. 방법 : 대조군과 폐결핵환자에서 폐포대식세포와 말초혈액내 단구세포를 분리하여 기저상태 및 PMA로 자극한 후 분비되는 과산화음이온의 양을 ferricytochrome-C를 환원시켜 나타나는 발색반응을 이용하여 측정하였고, 단구세포의 경우 결핵환자의 혈청에 의해 어떤 변화를 보이는지 관찰하였다. 결과 : 1) 폐포대식세포에서 분비하는 과산화음이온은 폐결핵환자군와 대조군 사이에 차이가 없었고, PMA로 자극을 했을 때도 두군 사이에 차이가 없이 모두 유의한 증가를 보였다. 2) 말초혈액 단구세포에서 분비하는 과산화음이온은 폐결핵환자군과 대조군 사이에 차이가 없었지만, PMA로 자극을 했을 때 두군에서 모두 유의한 증가를 보였고 폐결핵환자군이 대조군에 비해 높았다. 한편 결핵환자 혈청으로 폐결핵환자군과 대조군의 말초혈액 단구세포를 자극했을 때도 두군에서 모두 유의하게 증가되었다. 결론 : 폐포대식세포와 말초혈액 단구세포에서 분비하는 과산화음이온의 양은 정상인과 폐결핵환자에서 차이가 없었다. 따라서 폐포대식세포에서의 과산화음이온 분비가 부족하여 결핵균이 폐포대식세포내에서 장기간 생존하는 것으로 생각되지 않으며, 오히려 결핵환자의 혈청내에는 말초혈액 단핵구의 과산화음이온 분비를 자극하는 물질이 있을 것으로 생각되나, 정상인 혈청이 과산화음이온 생성에 미치는 효과에 대한 비교 연구가 필요할 것으로 사료된다.

  • PDF

레이저 처리가 상아질과 복합 레진의 결합에 미치는 영향 (Effects of laser-irradiated dentin on shear bond strength of composite resin)

  • 김성숙;박종일;이재인;김계순;조혜원
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.520-527
    • /
    • 2008
  • 목적: 이 연구는 산부식 대신 레이저로 표면처리를 하였을 때 복합레진과의 전단결합강도에 어떤 영향을 주는지 알아보기 위해 시행되었다. 재료 및 방법: 치아 우식증이 전혀 없는 건전한 최근에 발치된 대구치를 레진으로 매몰하고 상아질을 노출시킨 뒤 표면연마를 시행하 였다. 치아는 10개씩 4그룹으로 나누었다. 1) 아무 처리도 하지 않은 군, 2) 35% 인산으로 산부식한 군, 3) Er:YAG laser 레이저 처리된 군, 4) Er,Cr:YSGG laser로 처리된 군. 시편에 상아질 접착제 Single Bond2 (3M/ESPE)를 도포하고, 직경 3 mm, 높이 3 mm의 투명한 플라스틱관을 치아면 위에 두고 복합레진을 축성하였다. 모든 시편은 24시간동안 $37^{\circ}C$증류수에 보관 후 만능시험기를 이용하여 전단결합강도를 측정하였다. 결과: 레이저 처리시 각각 Er:YAG 레이저 처리는 $3.98{\pm}0.88$ MPa, Er,Cr:YSGG 레이저 처리는 $3.70{\pm}1.55$ MPa의 결합강도를 보였고, 통계적으로 유의한 차이를 나타내지 않았다. 아무 처리도 하지 않은 군의 결합강도는 $1.52{\pm}0.42$ MPa로 가장 낮은 결합강도를 나타내었고, 산처리를 한 군이 $7.10{\pm}1.86$ MPa로 가장 높은 전단결합강도를 보였으며, 이들은 레이저 처리한 군과 비교시 통계적으로 P < .001 유의수준에서 유의한 차이가 있는 것으로 나타났다. 결론: 치아와 레진의 전단결합강도 비교시 레이저 처리는 아무 처리도 않은 군에 비해서는 높지만 인산 etching보다 그 결합력이 떨어진다.