• 제목/요약/키워드: Plastic adhesion

검색결과 212건 처리시간 0.025초

Characteristics of adhesion areas between the tissue expander and capsule in implant-based breast reconstruction

  • Lim, Yoon Min;Park, Kwang Hyun;Lee, Dong Won;Lew, Dae Hyun;Roh, Tai Suk;Song, Seung Yong
    • Archives of Plastic Surgery
    • /
    • 제46권4호
    • /
    • pp.330-335
    • /
    • 2019
  • Background The use of anatomic implants has improved the aesthetic results of breast surgery; however, implant malrotation is an uncommon, but serious complication of these procedures. Nevertheless, little research has explored implant adhesion. In this study, we investigated adhesion between the expander and the capsule. Methods Seventy-nine cases of immediate breast reconstruction via two-stage implant-based reconstruction performed between September 2016 and November 2017 were evaluated. Mentor CPX4 expanders were used in 14 breasts, and Natrelle expanders in 65. We analyzed areas of adhesion on the surfaces of the tissue expanders when they were exchanged with permanent implants. We investigated whether adhesions occurred on the cephalic, caudal, anterior, and/or posterior surfaces of the expanders. Results Total adhesion occurred in 18 cases, non-adhesion in 15 cases, and partial adhesion in 46 cases. Of the non-adhesion cases, 80% (n=12) were with Mentor CPX4 expanders, while 94.4% (n=17) of the total adhesion cases were with Natrelle expanders. Of the partial adhesion cases, 90.7% involved the anterior-cephalic surface. The type of tissue expander showed a statistically significant relationship with the number of attachments in both univariate and multivariate logistic regression analyses (P<0.001) and with total drainage only in the univariate analysis (P=0.015). Conclusions We sought to identify the location(s) of adhesion after tissue expander insertion. The texture of the implant was a significant predictor of the success of adhesion, and partial adhesion was common. The anterior-cephalic surface showed the highest adhesion rate. Nevertheless, partial adhesion suffices to prevent unwanted rotation of the expander.

Laser Welding Parameter Variations and its Application for Plastic Adhesion

  • Park, Sung-Jin;Park, Sung-Joon;Park, Hae-Young;Park, Jae-Wook;Sim, Ji-Young;Choi, Jin-Young;Kim, Hee-Je
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.112-117
    • /
    • 2007
  • a parametric investigation was conducted to evaluate the effect of the laser beam for plastic adhesion. To determine the best condition for plastic adhesion, the $CO_2$(wavelength $10.6{\mu}m$) and nd:yag(wavelength $10.6{\mu}m$) laser were experimented with. From the experiment results obtained, the nd:yag laser was revealed to be the most suitable for plastic adhesion. In this study, three adhesion parameters such as input power level, working time of laser beam and pps(pulse per second) were systematically adjusted for suitable adhesion. From these experiments, it was observed that the target plastic melted and was evaporated by the nd:yag laser. Furthermore, the relationships between adhesive surface by laser beam and above three parameters were discovered.

가토의 굴곡건 손상모델에서 Mitomycin-C가 인대 유착 방지에 미치는 영향 (The Effect of Mitomycin-C on Preventing Adhesion of Injured Flexor Tendon in Rabbit Model)

  • 성정화;강소라;김양우
    • Archives of Plastic Surgery
    • /
    • 제37권4호
    • /
    • pp.329-334
    • /
    • 2010
  • Purpose: Adhesion after flexor tendon injury is a result of fibrosis between tendon and tendon sheath. This, finally interfere with gliding mechanism of tendon and results in functional problem of hands. Therefore, there have been many trials to reduce adhesion around the tendon. However, there is no standard procedure clinically practiced in hospitals. Mitomycin-C is an antineoplastic alkylating agent that decrease fibroblast proliferation and scar formation. It is commonly used in many surgery to reduce postoperative adhesion. This study was designed to observe the effect of Mitomycin-C on preventing adhesion in injured flexor tendon. Methods: The deep flexor tendon of digit 2 and 4 in the left forepaw of 15 New Zealand White rabbits were subjected to partial tenotomy. In study group, injury site was exposed to a single 5-minute application of Mitomycin-C, and in control group was left untreated. Digit 2 and 4 in the right forepaw of each rabbit were considered as nonadhesion control group. After 2 weeks, the animals were sacrificed and digits were amputated for biomechanical test and histological study. Results: In biomechanical study to measure yield point, mean yield point of non-adhesion control was $17.43{\pm}2.33$ and $25.07{\pm}4.03$ for adhesion control, which proves increase of adhesion in adhesion control group (p<0.05) in 95% confidence. In Mitomycin-C group, mean yield point was $12.71{\pm}4.97$. Compared with adhesion control, there was decrease in adhesiveness in Mitomycin-C group (p<0.05) in 95% confidence. In histological study, the result of adhesion control revealed massive adhesions of bony structure, fibrotic tissue and tendon structure with ablation of the border. However in Mitomycin-C group, we could find increased fibrotic tissue, but adhesion is much lesser than adhesion group and borders between structures remain intact. Conclusion: This study suggests that Mitomycin-C can significantly reduce adhesion of injured flexor tendon in rabbit model.

토끼 모델에서 굴근 인대 봉합 후 가딕스®의 유착 방지 효과 (Adhesion Prevention with Guardix® (Sodium Hyaluronate) After Flexor Tendon Repair in Rabbits)

  • 김학영;장학;민경원
    • Archives of Plastic Surgery
    • /
    • 제36권5호
    • /
    • pp.543-547
    • /
    • 2009
  • Purpose: Adhesion is the most common and troublesome complication after repair of flexor tendon injury. Recently, use of sodium hyaluronate derivatives for adhesion prevention is increasing. A commercial product, Guardix$^{(R)}$, sodium hyaluronate(NaHe) combined with carboxymethylcellulose(CMC) has been newly developed as a preventive material for adhesion. We have investigated its effect in rabbits. Methods: Twenty seven male New Zealand white rabbits were operated under ketamine anesthesia. After tendon repair in zone II of the hind paw, Guardix$^{(R)}$(experimental group) or normal saline(control group) was administered. Biomechanical tests were performed to estimate adhesion formation at 2, 4, 8, and 12 weeks after the operation. Maximum tensile load to flex the distal interphalangeal joint 50 degree from its resting state(MTL50) was measured, depicting the amount of adhesion formed. Subsequently, breaking strength was assessed. Results: There were no postoperative complications such as infection, wound dehiscence, or hematoma. MTL50 was significantly lower in the experimental group than in the control group at 4, 8, 12 weeks (p<0.05). Mean value of MTL50 was 6.64N in the experimental group and 28.53N in the control group at 12 weeks after surgery. There were no significant differences in breaking strength. Conclusion: Our results indicate that Guardix$^{(R)}$ is helpful in reducing adhesion formation and does not interfere with normal healing processes of the tendon.

피에르 로빈 연속증의 치료로써 치조 보호 장치를 이용한 혀-하순 유착술 (Tongue-Lip Adhesion Using an Alveolar Protector Appliance for Management of Pierre Robin Sequence)

  • 이장원;박병윤
    • Archives of Plastic Surgery
    • /
    • 제38권4호
    • /
    • pp.547-551
    • /
    • 2011
  • Purpose: Pierre Robin sequence is a congenital malformation in which micrognathia causes glossoptosis and airway obstruction. If conservative treatment fails, surgical procedures such as tongue-lip adhesion can be performed. However, this procedure remains a subject of debate, with favorable results being countered by reports of complications. To overcome the above limitations, we revised the traditional method of tongue-lip adhesion using an alveolar protector. Methods: Between 1992 and 2011, a total of eight patients were identified with Pierre Robin sequence and were treated with tongue-lip adhesion. Two of these eight tongue-lip adhesion procedures were performed with an alveolar protector. The operative technique for tongue-lip adhesion was similar to that described in other published reports. The alveolar protector was inserted between the ventral surface of the tip of the tongue and the lower labial sulcus. Results: Tongue-lip adhesion failed in two patients because of wound dehiscence. The primary surgical success rate was 66.7%. In the two tongue-lip adhesion procedures performed with the alveolar protector, we observed no postoperative complications. Conclusion: Resistance to traction of the tongue can be encountered with nonunionized symphysis menti, causing loosening of the traction suture through the symphysis menti. This can lead to backward positioning of tongue, resulting in dehiscence of tongue lip adhesion. The alveolar protector is a good adjunct to tongue-lip adhesion because this method avoids postoperative loosening of the traction suture and wound dehiscence. It is a simple and effective auxiliary method that yields functional improvement.

Long-Term Evaluation of the Lip and Nose in Bilateral Complete Cleft Lip Patients following Lip Adhesion and Secondary Nose Correction

  • Kim, Ryuck Seong;Seo, Hyung Joon;Park, Min Suk;Bae, Yong Chan
    • Archives of Plastic Surgery
    • /
    • 제49권4호
    • /
    • pp.510-516
    • /
    • 2022
  • Background Surgical correction of bilateral cleft lip deformities remains one of the most challenging areas in facial plastic surgery. Many surgical techniques and conservative devices have been offered for the early management of bilateral cleft lip in infants. The purpose of this study was to evaluate the effect of lip adhesion on the lip and nose of patients with bilateral cleft lip. Methods A retrospective review of 13 patients with bilateral cleft lip was performed and compared with age-matched noncleft children. Patients underwent lip adhesion at a mean age of 2.8 months, and cheiloplasty at 6.6 months of age using a modification the Mulliken method. Secondary rhinoplasty was performed at the age of 6 in 13 patients. The surgical results were analyzed using photographic records obtained at the age of 1 and 7 years. Twelve length measurements and one angle measurement were obtained. Results All measurements were not statistically different from those of the noncleft age-matched control group at the age of 1. At 7 years of age, upper lip height and vermilion mucosal height were shorter (p < 0.05) than in the control group. Nasal tip protrusion and the nasolabial angle were greater (p < 0.05) than in the control group. Conclusion Lip adhesion followed by secondary rhinoplasty resulted in an acceptable lip and nasal appearance. Although nasoalveolar molding is now widely used, lip adhesion can be an appropriate alternative if an orthodontist is not available due to geographical or economic constraints.

Tongue-lip adhesion in Pierre Robin sequence

  • Kumar, K.S. Krishna;Vylopilli, Suresh;Sivadasan, Anand;Pati, Ajit Kumar;Narayanan, Saju;Nair, Santhy Mohanachandran
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제42권1호
    • /
    • pp.47-50
    • /
    • 2016
  • Patients with Pierre Robin sequence exhibit varying degrees of airway obstruction and feeding difficulty. In some patients, airway obstruction may be profound, warranting surgical intervention to maintain a patent airway. The purpose of this article is to highlight the advantages of the tongue-lip adhesion procedure for the management of airway obstruction in such patients compared to the currently available options.

Cu-Cr 합금박막의 필 접착력과 소성변형 (Peel Adhesion Strength and Plastic Deformation of Cu-Cr Alloy Thin Films)

  • 이태곤;임준홍;김영호
    • 한국표면공학회지
    • /
    • 제28권4호
    • /
    • pp.219-224
    • /
    • 1995
  • The peel adhesion and plastic deformation in Cu-Cr alloy films, sputter-deposited onto polyimide films, have been studied as a function of Cr content in the film. The adhesion strength has been measured by T-peel test and the amount of plastic deformation in the peeled metal strip was determined qualitatively by XRD technique. Peel adhesion strength has a maximum in the film containing 22-33wt.% Cr and the peel strength of pure Cr film is lower than the maximum. The film having the highest peel strength is deformed most heavily. The effect of Cr content on the peel strength is discussed in terms of the interfacial bond strength and mechanical properties of Cu-Cr alloy film.

  • PDF

플라스틱 BGA 패키지의 아르곤 가스 플라즈마 처리 효과 (Effect of Ar Gas Plasma Treatment of Plastic Ball Grid Array Package)

  • 신영의;김경섭
    • 한국전기전자재료학회논문지
    • /
    • 제13권10호
    • /
    • pp.805-811
    • /
    • 2000
  • Reliability of PBGA(plastic ball grid array) package is weak compared with normal plastic packages. The low reliability is caused by low resistance to the popcorn cracking, which is generated by moisture absorption in PCB(prited circuit board). In this paper, plasma treatment process was used and we analyzed its effects to interface adhesion. The contents of C and Cl decrease after plasma treatment but those of O, Ca, N relatively increase. The plasma treatment improves the adhesion between EMC(epoxy molding compound) and PCB(solder mask). The grade of improvement was over 100% Max, which depends on the properties of EMC. The RMS(root mean square) roughness value of the solder mask surface increases to plasma treatment. There is little difference of adhesion in RF power and treatment time.

  • PDF

5, 100 mtorr의 증착압력에서 스퍼터 증착한 구리박막층이 Cu/Cr 박막과 폴리이미드 사이의 접착력에 미치는 영향 (The effects of Cu thin films sputter deposited at 5 and 100 mtorr on the adhesion between Cu/Cr film and polyimide)

  • 조철호;김영호
    • 한국표면공학회지
    • /
    • 제29권3호
    • /
    • pp.157-162
    • /
    • 1996
  • The effects of microstructural change on the adhesion strength between Cu/Cr film and polyimide have been studied. Cr films (50 nm thick) and Cu films (500 or 1000 nm thick) were deposited on polyimide by DC magnetron sputtering. During Cu deposition the Ar pressure was 5 or 100 mtorr. The microstructure was observed by SEM and the adhesion was measured by T-peel test. Plastic deformation of peeled metal strips was characterized quantitatively by using XRD technique. The film in which Cu is deposited at 100 mtorr has higher adhesion strength than the film in which Cu is deposited at 5 mtorr. And in the film with same deposition pressure of 100 mtorr, the adhesion strength is increased as the deposited thickness increases from 500 to 1000 nm. The adhesion change of Cu/Cr can be interpreted as the difference in plastic deformation.

  • PDF