• 제목/요약/키워드: Plastic Dissipation Energy

검색결과 210건 처리시간 0.022초

Estimation of Plastic Energy Dissipation Amount of Multi-bent Spatial structure by Equivalent Linear Analysis

  • 이승재
    • 한국공간구조학회논문집
    • /
    • 제6권2호
    • /
    • pp.131-136
    • /
    • 2006
  • It is important to evaluate energy absorption capacity of frames required during a design earthquake. An inelastic computer analysis based on mathematical modelling of energy absorbing frames and elements makes it possible to evaluate required energy absorption capacity. But such an analysis sometimes consumes much computation time particularly in case of complicated structural system. This paper presents a proposal to predict energy absorption of multi-bent steel frames by simple equivalent linear method.

  • PDF

The length of plastic hinge area in the flanged reinforced concrete shear walls subjected to earthquake ground motions

  • Bafti, Farzad Ghaderi;Mortezaei, Alireza;Kheyroddin, Ali
    • Structural Engineering and Mechanics
    • /
    • 제69권6호
    • /
    • pp.651-665
    • /
    • 2019
  • Past earthquakes have shown that appropriately designed and detailed buildings with shear walls have great performance such a way that a considerable portion of inelastic energy dissipation occurs in these structural elements. A plastic hinge is fundamentally an energy diminishing means which decrease seismic input energy through the inelastic deformation. Plastic hinge development in a RC shear wall in the areas which have plastic behavior depends on the ground motions characteristics as well as shear wall details. One of the most generally used forms of structural walls is flanged RC wall. Because of the flanges, these types of shear walls have large in-plane and out-of-plane stiffness and develop high shear stresses. Hence, the purpose of this paper is to evaluate the main characteristics of these structural components and provide a more comprehensive expression of plastic hinge length in the application of performance-based seismic design method and promote the development of seismic design codes for shear walls. In this regard, the effects of axial load level, wall height, wall web and flange length, as well as various features of earthquakes, are examined numerically by finite element methods and the outcomes are compared with consistent experimental data. Based on the results, a new expression is developed which can be utilized to determine the length of plastic hinge area in the flanged RC shear walls.

다양한 배근상세를 갖는 짧은 연결보의 주기거동 특성과 에너지소산능력의 평가 (Behavioral Characteristics and Energy Dissipation Capacity of Short Coupling Beams with Various Reinforcement Layouts)

  • 엄태성;박홍근;강수민
    • 콘크리트학회논문집
    • /
    • 제20권2호
    • /
    • pp.203-212
    • /
    • 2008
  • 본 연구에서는 다양한 배근상세를 갖는 짧은 연결보 (short coupling beam)의 주기거동특성과 에너지소산 메커니즘을 연구하였다. 주기하중을 받는 연결보의 수치해석을 위하여 비선형트러스모델 (nonlinear truss model)을 사용하였다. 수치해석 결과, 일반적인 수직 수평배근상세를 갖는 연결보는 핀칭이 심한 주기곡선을 보이며 거의 에너지를 소산하지 못하였다. 반면 대각배근상세를 갖는 연결보는 핀칭이 없는 안정적인 주기거동을 보이며 많은 에너지를 소산하였으며, 연결보의 에너지소산은 취성재료인 콘크리트보다 주로 대각 방향으로 배치된 철근에 의하여 발생됐다. 이러한 분석 결과를 토대로 대각철근의 변형률 이력을 사용하여 연결보의 에너지소산량을 예측할 수 있는 간편한 평가식을 개발하였다. 검증을 위하여 제안된 평가식과 실험으로 구한 연결보의 에너지소산량을 실험 결과와 비교하였다. 그 결과, 제안된 평가식은 배근형태, 전단경간비, 비탄성 변형 크기 등 다양한 설계변수의 영향을 고려하여 전단경간비가 1.25이하인 짧은 연결보의 에너지소산량을 비교적 정확히 예측하였다. 제안된 에너지소산량 평가 방법은 철근콘크리트구조물 및 부재의 성능 기초 내진평가/설계에 손쉽게 활용될 수 있다.

간이충돌모델을 이용한 파일형 선박충돌방호공의 충돌거동 연구 (A Study on Behaviors of Pile Protective Structures by Simplified Collision Model)

  • 이계희
    • 대한토목학회논문집
    • /
    • 제36권1호
    • /
    • pp.31-38
    • /
    • 2016
  • 논문에서는 파일형 선박충돌방호공의 주요 에너지 소산기구인 파일의 소성힌지와 선수변형에 대한 변형-에너지곡선을 산정하고 이를 이전 연구에서 개발된 간이 충돌모델에 적용하여 매개변수해석을 수행하였다. 고려된 매개변수는 슬래브의 질량, 파일의 수, 선박의 질량 및 충돌속도였으며 이들 매개변수를 변화시키면서 충돌거동을 분석하였다. 연구결과, 충진강관과 비충진강관의 에너지 소산거동이 차이를 파악했고, 슬래브의 관성질량을 조절하여 방호공의 충돌거동을 변화 시킬 수 있는 것으로 나타났다. 따라서 개발된 간이모델은 기본설계나 최적설계에 이용될 수 있을 것이다.

Ductile capacity study of buckling-restrained braced steel frame with rotational connections

  • Mingming Jia;Jinzhou He;Dagang Lu
    • Steel and Composite Structures
    • /
    • 제46권3호
    • /
    • pp.417-433
    • /
    • 2023
  • The maximum ductility and cumulative ductility of connection joints of Buckling-Restrained Braced Frames (BRBF) are critical to the structural overall performance, which should be matched with the BRB ductility. The two-story and one-span BRBF with a one-third scale was tested under cyclic quasi-static loading, and the top-flange beam splice (TFBS) rotational connections were proposed and adopted in BRBF. The deformation capacity of TFBS connections was observed during the test, and the relationship between structural global ductility and local connection ductility was studied. The rotational capacity of the beam-column connections and the stability performance of the BRBs are highly relevant to the structural overall performance. The hysteretic curves of BRBF are stable and full under large displacement demand imposed up to 2% story drift, and energy is dissipated as the large plastic deformation developed in the structural components. The BRBs acted as fuses and yielded first, and the cumulative plastic ductility (CPD) of BRBs is 972.6 of the second floor and 439.7 of the first floor, indicating the excellent energy dissipation capacity of BRBs. Structural members with good local ductility ensure the large global ductility of BRBF. The ductile capacity and hysteretic behavior of BRBF with TFBS connections were compared with those of BRBF with Reduced Beam Section (RBS) connections in terms of the experimental results.

Seismic performance enhancement of a PCI-girder bridge pier with shear panel damper plus gap: Numerical simulation

  • Andika M. Emilidardi;Ali Awaludin;Andreas Triwiyono;Angga F. Setiawan;Iman Satyarno;Alvin K. Santoso
    • Earthquakes and Structures
    • /
    • 제27권1호
    • /
    • pp.69-82
    • /
    • 2024
  • In the conventional seismic design approach for a bridge pier, the function of the stopper, and shear key are to serve as mechanisms for unseating prevention devices that retain and transmit the lateral load to the pier under strong earthquakes. This frequently inflicts immense shear forces and bending moments concentrated at the plastic hinge zone. In this study, a shear panel damper plus gap (SPDG) is proposed as a low-cost alternative with high energy dissipation capacity to improve the seismic performance of the pier. Therefore, this study aimed to investigate the seismic performance of the pre-stressed concrete I girder (PCI-girder) bridge equipped with SPDG. The bridge structure was analyzed using nonlinear time history analysis with seven-scaled ground motion records using the guidelines of ASCE 7-10 standard. Consequently, the implementation of SPDG technology on the bridge system yielded a notable decrease in maximum displacement by 41.49% and a reduction in earthquake input energy by 51.05% in comparison to the traditional system. This indicates that the presence of SPDG was able to enhance the seismic performance of the existing conventional bridge structure, enabling an improvement from a collapse prevention (CP) level to an immediate occupancy (IO).

철골접합부 상세별 에너지 소산 (Energy Dissipation of Steel Connection Details)

  • 김장훈
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.155-162
    • /
    • 2003
  • The evolved energy concept has been demonstrated to fir the seismic evaluation of various steel connection details with the objective basis. For this, the strain energy stored in the structural system obtained from the experimental database has been normalized by that of a benchmark system. In this notion, the ideal elastic-perfectly plastic structural system has been assumed as a benchmark. In addition, the attempt shows that those previously peformed experimental database can be recycled to have further significance.

  • PDF

Case Study On The Seismic Design Strategy For Post-Quake Functional Buildings In China

  • Peng Liu;Xue Li;Yu Cheng;Xiaoyu Gao;Jinai Zhang;Yongbin Liu
    • 국제초고층학회논문집
    • /
    • 제12권3호
    • /
    • pp.251-262
    • /
    • 2023
  • In response to China's "Regulations on the Management of Earthquake Resistance of Building Constructions" on the provision of eight types of important buildings to maintain functional after fortified earthquakes occur, "Guidelines for Seismic Design of post-quake functional buildings (Draft for Review)" distinguishes Class I and Class II buildings, and gives the performance objectives and seismic verification requirements for design earthquakes and severe earthquakes respectively. In this paper, a hospital and a school building are selected as examples to design according to the requirements of fortification of Intensity 8 and 7 respectively. Two design strategies, the seismic isolation scheme and energy dissipation scheme, are considered which are evaluated through elastic-plastic dynamic time-history analysis to meet the requirement of post-quake functional buildings. The results show that the seismic isolation design can meet the requirements in the above cases, and the energy dissipation scheme is difficult to meet the requirements of the "Guidelines" on floor acceleration in some cases, for which the scheme shall be made valid through the seismic resilience assessment. The research in this paper can provide a reference for designers to choose schemes for post-quake functional buildings.

돌핀방호공의 선박충돌해석 (The ship collision analysis of dolphin protection system)

  • 이계희;이성로;고재용;유원진
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.143-150
    • /
    • 2005
  • In this study, to evaluate the collision behaviors of the navigating vessel and the dolphin protective system protecting the substructures of bridges, the numerical simulation was performed. The analysis model of vessel bow that the plastic deformations are concentrated was composed by shell elements, and the main body of vessel was modeled by beam elements to represent the mass distribution and the change of potential energy. The material model reflecting the confining condition was used for the modeling of the filling soil of dolphin system. The surrounding soil of the dolphin system was modeled as nonlinear springs. As results, it is verified that the dolphin system can adequately dissipate the kinematic energy of the collision vessel. The surrounding soil of the dolphin system is able to resist the collision force of the vessel. And the major energy dissipation mechanism of collision energy is the plastic deformation of the vessel bow and the dolphin system.

  • PDF

Application of shakedown analysis technique to earthquake-resistant design of ductile moment-resisting steel structures

  • Lee, Han-Seon;Bertero, Vitelmo V.
    • Structural Engineering and Mechanics
    • /
    • 제1권1호
    • /
    • pp.31-46
    • /
    • 1993
  • The motivations of the application of shakedown analysis to the earthquake-resistant design of ductile moment-resisting steel structures are presented. The problems which must be solved with this application are also addressed. The illustrative results from a series of static and time history nonlinear analyses of one-bay three-story steel frame and the related discussions have shown that the incremental collapse may be the critical design criterion in case of earthquake loading. Based on the findings, it was concluded that the inelastic excursion mechanism for alternation load pattern, such as in earthquake, should be the sidesway mechanism of the whole structure for the efficient mobilization of the structural energy dissipating capacity and that the shakedown analysis technique can be used as a tool to ensure this mechanism.