• 제목/요약/키워드: Plasma-Solution System

검색결과 122건 처리시간 0.035초

Effect of Supplementation of Trehalose, Glycerol on Conventional Freezing and Vitrification of Boar Sperm

  • Choi, Sun-Ho;Lee, Mi-Jin;Lee, Kyung-Mi;Sa, Soo-Jin;Kim, Hyun-Jong;Jin, Hyun-Ju;Song, Yong-Sup;Park, Jun-Cheol
    • 한국수정란이식학회지
    • /
    • 제29권4호
    • /
    • pp.397-401
    • /
    • 2014
  • The boar sperm has more lipid droplets and specialty of seminal plasma compared with other species, causing difficulties of freezing sperm and decreases for the utilization of frozen semen into the artificial insemination. However, several studies reported significant results for the recovery of sperm motility and reproductive by addition of cryoprotectants and seminal plasma after thawing. This study was designed to investigate the effects of supplementation of trehalose or glycerol in the LEY (lactose and egg yolk in BTS) solution for the conventional freezing and vitrification process. Two boars aged 16 months were used to collect semen for 2 times in a week. The samples were allotted to 3 freezing solutions (LEY + glycerol 10.5% + OEP 1.5%, LEY + trehalose 1M + OEP 1.5%, and sucrose 1.5M + trehalose 1 M + OEP 1.5%) after centrifugation at 800 g for 10 minutes. Semen was equilibrated in freezing solutions for 10 minutes and injected into plastic straws with 2~3 air bubbles to minimize freezing damages. Vitrification was performed to locate sperm in 5 cm above $LN_2$ for 5 minutes, and the conventional freezing was conducted with an automatic freezer. Motility and survival rates were measured by CASA (Computer assisted sperm an alyzing system) and FITC (Fluorescein isothiocyanate), respectively after thawing semen at $50^{\circ}C$ for 12 seconds. The results were analyzed by ANOVA with STATVIEW statistical program. The vitrificatioin solution (LEY + 10.5% glycerol + 1.5% OEP) presented higher motility (20.9%) than other solutions while the solution (LEY + 1M trehalose + 1.5% OEP) showed the lowest (motility : 5.2%). However, survival rates of vitrified sperms detected by FITC showed 1~4% live sperms in almost of dead sperms at all vitrification solutions' groups, but survival rate of freezing solution of LEY + 1M trehalose + 1.5% OEP LEY and LEY + 10.5% glycerol + 1.5% OEP were showed 49%, and 79%, respectively. There were differences (P<0.05) survival rate of conventional freezing in LEY + 10.5% glycerol + 1.5% OEP and LEY + 1M trehalose + 1.5% OEP and the remaining showed no differences. The results suggested that vitrified boar semen was not enough to be utilized for the artificial insemination, but it showed possibility to utilize for ICSI and conventional freezing with glycerol would be useful method for artificial insemination in pig while we choose the outstanding semen against tolerance to freezing damages.

Determination of Mercury in Fly Ash by Using Flow Injection Cold Vapor Isotope Dilution Inductively Coupled Plasma Mass Spectrometry

  • Suh, Jung-Ki;Min, Hyung-Sik;Kamruzzaman, Mohammad;Lee, Sang-Hak
    • Mass Spectrometry Letters
    • /
    • 제3권2호
    • /
    • pp.58-61
    • /
    • 2012
  • A method based on flow injection-isotope dilution-cold vapor-inductively coupled plasma mass spectrometry (FI-IDCV-ICP/MS) has been applied to determine trace level of mercury in fly ash. $^{200}Hg$ isotopic spike was added to 0.25 g of BCR176R fly ash and then decomposed by microwave digestion procedure with acid mixture A (8 mL $HNO_3$ + 2 mL HCl + 2 mL HF) and acid mixture B (8 mL $HNO_3$ + 2 mL $HClO_4$ + 2 mL HF) for applying IDMS. Mercury cold vapor was generated by using reductant solution of 0.2% (w/w) $NaBH_4$ and 0.05% (w/w) NaOH. The measurements of n($^{200}Hg$)/n($^{202}Hg$) isotope ratio was made using a quadrupole ICP/MS system. The accuracy in this method was verified by the analysis of certified reference material (CRM) of fly ash (BCR 176R). The indicative value of Hg in BCR 176R fly ash was $1.60{\pm}0.23$ mg/kg (k = 2). The determined values of Hg in BCR 176R fly ash by the method of FI-CV-ID-ICP/MS described in this paper were $1.60{\pm}0.24$ mg/kg (k = 3.18) and the analysis results were in well agreement with the indicative value within the range of uncertainty.

Effect of Resveratrol on Serum and Liver Lipid Profile and Antioxidant Activity in Hyperlipidemia Rats

  • Zhu, Lixian;Luo, Xin;Jin, Zhengyu
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제21권6호
    • /
    • pp.890-895
    • /
    • 2008
  • The antioxidant activity of resveratrol in cholesterol-fed rats, along with its hypolipidemic effects was determined. Thirty two male Sprague-Dawley (SD) rats were randomly divided into three groups (Control, Res30 and Res70) and fed a hyperlipidemic diet for 4 weeks. Resveratrol was suspended in 0.3% carboxymethyl cellulose (CMC) solution and given to rats of the Res30 and Res70 groups once a day for 4 weeks by oral intubation at a dose of 30 and 70 mg/kg body weight, respectively. The control group received 0.3% CMC solution alone. Resveratrol significantly lowered serum lipid, hepatic cholesterol (TC) and triglyceride (TG) levels compared to the control. Excretion of bile acids was significantly enhanced by resveratrol. The overall potential of the antioxidant system was significantly enhanced by the resveratrol as plasma and hepatic thiobarbituric acid reactive substances (TBARS) levels were lowered while serum superoxide dismutase (SOD), glutathione peroxidase (GSH-Px) and catalase (CAT) activities were increased in the cholesterol-fed rats. These findings suggest that resveratrol maintains an antioxidant efficacy as well as its anti-hyperlipidemic effect.

입자모사를 통한 HALL EFFECT THRUSTER의 플라즈마 운동 이해 (A VIEW PLASMA MOTION OF HALL EFFECT THRUSTER WITH PARTICLE SIMULATION)

  • 이재진;정성일;최원호;이종섭;임유봉;서미희;김형명
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2007년도 한국우주과학회보 제16권2호
    • /
    • pp.139-143
    • /
    • 2007
  • 전기 추진시스템은 저렴한 개발비와 높은 신뢰성을 제공하는 추진 장치로 많은 분야에서 응용 되어 왔다. 특히 최근에 발사된 SMART-1과 MUSES-C는 우리에게 시사하는 바가 크다. 각각 European Space Agency(ESA)와 Japan Aerospace Exploration Agency(JAXA)에서 개발한 행성 탐사선으로, SMART-1은 달 탐사를 목적으로 하고 MUSES-C는 소행성 Itokawa의 토양을 채취해오는 것을 목적으로 한다. 이 두 탐사선에는 각각 Hall effect thruster와 Micro wave ion engine이 탑재되었는데, 작고 저렴한 비용의 탐사선을 이용해서 충분히 행성 탐사가 가능하다는 좋은 선례를 남겼다. 현재 개발되고 있는 과학기술위성 3호(STSAT-3)에도 전기추진 장치가 탑재되는데, SMART-1에 탑재 되었던 것과 유사한 Hall effect thruster가 인공위성 연구센터와 KAIST 물리학과의 GDPL과 공동으로 개발되고 있다. 성능이 좋은 전기 추력 장치를 개발하기 위해 추력기 내부에서 발생하는 플라즈마의 물리적 특성을 파악하는 것은 매우 중요한 일이다. 이 논문에서는 이러한 플라즈마의 특성을 모사하는 방법으로 Particle In Cell 모사와 더불어 독립적인 개개 입자의 운동을 기술하는 입자모사(particle simulation)를 이용하는 방법을 제시 하고자 한다. 이러한 접근 방법은 실제 전기추력장치를 설계하고 실험하는 담당자에게 플라즈마 운동에 대한 명료한 지식을 제공해 줄 수 있을 것으로 생각된다.

  • PDF

신통축어탕(身痛逐瘀湯)의 항염(抗炎), 진통(鎭痛) 및 항열전효과(抗血栓效果)에 관(關)한 연구(硏究) (Study on the Anti-inflammatory, Analgesic and Anti-thrombotic Effects of Shintongchugeotang in the Experimental Animals)

  • 유지용;이기상;문병순
    • 대한한방내과학회지
    • /
    • 제18권1호
    • /
    • pp.69-85
    • /
    • 1997
  • This study was designed to elucidate the anti-inflammatory, cardiovascular, anti-thrombotic and analgesic effects of Shintongchugeotang. The anti-inflammatory effect was measured by the method of carragenin induced edema, protein leakage test using CMC-pouch, and the analgesic effect was measured by the acetic acid method and hot plate method, and the effect of Shintongchugeotang on the cardiovascular system was observed by the change of flow rate of Ringer solution in the vascular system in the ear of rabbit, and the contraction and dilatation of rat tail artery. Death rate, platelet aggregation, plasma coagulation activity was observed for the measurement of the anti-coagurative effect of Shintongchugeotang. The result was as follows : 1. After the administration of Shintongchugeotang extract, Carragenin induced edema and CMC-pouch protein leakage were significantly decreased. 2. The slight analgesic effect of Shintongchugeotang extract was confirmed by the observation of writhing syndrome, paw licking time, and escape time. 3. The drug increased the auricular blood flow in rabbit. 4. The drug relaxed the artery contraction by pretreated norepinephrine in rat. 5. The drug inhibited the death rate of mouse which was led to thromboembolism by serotonin and collagen. 6. The drug inhibited the platelet aggregation in rat. 7. The drug prolonged the prothrombin time and activated partial thromboplastin time on the test of plasma coagulation factor activity in rat, but was not valuable.

  • PDF

삼비탕(三痺湯)의 항염(抗炎), 항응고(抗凝固) 및 진통효과(鎭痛效果)에 대(對)한 연구(硏究) (Study on the Antiinflammatory, Anticoagulative and Analgesic effects of Sambitang in the experimental animal model)

  • 류준기;이영구;문병순
    • 대한한방내과학회지
    • /
    • 제19권2호
    • /
    • pp.88-106
    • /
    • 1998
  • This study was designed to elucidate the antiinflammatory, cardiovascular, antithrombotic, and analgesic effect of Sambitang. The antiinflammatory effects was measured by the method of carrageenin induced edema, protein leakage test using CMC-pouch, and the effect of Sambitang on the cardiovascular system was observed by the change of flow rate of Ringer solution in the vascular system in the ear of rabbit, and the contraction and dilatation of rat tail artery. Death rate, platelet aggregation, plasma coagulation activity was observed for the measurement of the anticoagurative effect of Sambitang, and the analgesic effect was measured by the acetic acid method and hot plate method. The result was as follows: 1. Sambitang administration, edema and protein leakage was significantly decreased. 2. The drug increased the auricular blood flow in rabbit. 3. The drug relaxed the artery contraction by pretreated norepinephrine in rat. 4. The drug inhibited the death rate of mouse which was led to thromboembo- lism by serotonin and collagen. 5. The drug inhibited the platelet aggregation in rat. 6. The drug prolonged the prothrombin time and activated partial thromboplastin time on the test of plasma coagulation factor activity in rat, but was not valuable. 7. The slight anagesic effect of Sambitang extract was confirmed by the observation of writhing syndrome, paw licking time, and escape time.

  • PDF

Effect of Microstructure on Corrosion Behavior of TiN Hard Coatings Produced by Two Grid-Attached Magnetron Sputtering

  • Kim, Jung Gu;Hwang, Woon Suk
    • Corrosion Science and Technology
    • /
    • 제5권1호
    • /
    • pp.15-22
    • /
    • 2006
  • The introduction of two-grid inside a conventional process system produces a reactive coating deposition and increases metal ion ratio in the plasma, resulting in denser and smoother films. The corrosion behaviors of TiN coatings were investigated by electrochemical methods, such as potentiodynamic polarization test and electrochemical impedance spectroscopy (EIS) in deaerated 3.5% NaCl solution. Electrochemical tests were used to evaluate the effect of microstructure on the corrosion behavior of TiN coatings exposed to a corrosive environment. The crystal structure of the coatings was examined by X-ray diffractometry (XRD) and the microstructure of the coatings was investigated by scanning electron microscopy (SEM) and transmission electron spectroscopy (TEM). In the potentiodynamic polarization test and EIS measurement, the corrosion current density of TiN deposited by two grid-attached magnetron sputtering was lower than TiN deposited by conventional magnetron type and also presented higher Rct values during 240 h immersion time. It is attributed to the formation of a dense microstructure, which promotes the compactness of coatings and yields lower porosity.

염산지페프를 마이크로캅셀에 관한 생물약제학적 연구 (Biopharmaceutical Studies on Zipeprol Dihydrochloride Microcapsules)

  • 용재익;김옥남
    • Journal of Pharmaceutical Investigation
    • /
    • 제18권4호
    • /
    • pp.187-195
    • /
    • 1988
  • Poorly permeable $Eudragit^{\circledR}$ RS 100 polymer was used as a wall material for the microencapsulation of zipeprol dihydrochloride by a phase separation method from chloroform-cyclohexane system with 5% polyisobutylene in cyclohexane, and microcapsules obtained were evaluated in vitro by particle size analysis, scanning electron microscopy, drug release test and in vivo bioavailability test in rats. The mechanism of drug release from microcapsules appeared to fit Higuchi matrix model kinetics. The area under the first moment of plasma concentration-time curve of the microcapsules obtained was considerably increased (p<0.05) as compared with that from zipeprol dihydrochloride oral solution. Therefore, it may be suggested that $Eudragit^{\cirledR}$ RS 100 coated zipeprol dihydrochloride microcapsules can be used as a sustained release medication.

  • PDF

Disk MHD Accelerator with Swirl Vane and Its Performance

  • Takeshita, Shinji;Furuya, Seizo;Harada, Nobuhiro
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.536-542
    • /
    • 2008
  • The rocket technology has the best reliability and the high acceleration performance currently. In addition, next generation propulsion system is acquired to low cost and high payload percentage at that same time. This work is to improve the performance of Diskshaped MHD accelerator which is expected as the one of the solution. In this study we have been focusing on the swirl vane. It is so important to know that how the swirl vane contribute the plasma and its performance. As results, the gas velocities of r-component with inlet swirl were increased about over 3000m/s at the channel exit. And then static gas pressure were also reduced, we found that the case with inlet swirl gives the good influence to the acceleration performance. And the difference of the acceleration by positive and negative inlet swirl is that gas velocity of $\theta$-component may operate to the electric field.

  • PDF

Itaconic acid로 그라프트 공중합한 Chitosan의 beads를 이용한 수계 우라늄의 제거 (Removal of Uranium in Water by Beads of Chitosan the Graft-Copolymerized with Itaconic Acid)

  • 강수정;김남기;김재우;한상문
    • 환경위생공학
    • /
    • 제20권2호
    • /
    • pp.47-55
    • /
    • 2005
  • The World Health Organization(WHO, 1998) and the United States Environmental Protection Agency (USEPA, 1992) recommended $2{\mu}\;guranium/{\ell}$ in drinking water as a guideline. The Korea Institute for Environmental Research recently reported that the radioactive pollution in ground water was almost negligible In Korea$(1999\~2002)$. Cs were cast into beads(2mm in wet form) and treated with hexamethylene diisocyanate for stability in acidic aqueous solution through cross-linking of the beads surfaces. The removal study was carried out in a static batch system and a flow system. In the static system, a certain amount of sample water was confined in a vessel and beads(dry weight 0.5g) were packed into it in order to adsorb uranium for a certain period of time. Afterwards the remaining uranium in water vessel was determined by inductively coupled plasma mass spectrometry. The effective pH range was 4 to 8. The smaller the size of beads, the better the removal efficiency. Furthemore, the lower the flow rates, the higher the removal efficiency. The results showed that chitosan beads can be effectively used for the removal of uranium contained in water.