• 제목/요약/키워드: Plasma implantation

검색결과 153건 처리시간 0.022초

$Telazol^{\circledR}$ 투여가 임신 Rat의 생식에 미치는 영향 (The Effect of Exogenous $Telazol^{\circledR}$ on the Reproduction in Pregnant Rat)

  • 윤은희;김영홍
    • 한국임상수의학회지
    • /
    • 제16권1호
    • /
    • pp.42-49
    • /
    • 1999
  • The reproductive effect of $Telazol^{\circledR}$ was studied in pregnant rats. Two different doses (20 or 40 mg/kg/day) were injected on days one of 3, 5 or 8 of pregnancy and 3 consecutive days of 3~5 or 5~7 in pregnant rats. On days 8 or 21, the rats were anesthetized, the cesarean section was performed, the uterus was carefully examined, and the numbers of corpora lutea, implantation sites and viable fetuses, fetal and placental weights and pre-and post-implantation losses in rats were surveyed. Simultaneously the concentrations of sodium and potassium of the plasma, uterine and amniotic fluids were determined. And gestation period in pregnant rats, postnatal offspring survival and body weight gains were evaluated. Administration of $Telazol^{\circledR}$ did not exert a bad influence upon body weight gains in pregnant rats. Reproductive indices were normal. The concentrations of sodium and potassium of the plasma, uterine and amniotic fluids in pregnant rats remained unchanged. Gestation period of rats, postnatal offspring survival and body weight gains were normal. It is concluded that $Telazol^{\circledR}$ is devoided of significant adverse reproductive effects in pregnant rats.

  • PDF

흰쥐 자궁 및 착상에 있어서 Tamoxifen과 성스테로이드 호르몬의 상호관계 (Relationship between Tamoxifen and Sex Steroid Hormones on Uterus and Implantation in Rat)

  • 한호재;유규연;권종국;양일석
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제15권2호
    • /
    • pp.93-102
    • /
    • 1988
  • These studies were undertaken to examine the relationship between tamoxifen and sex steroid hormones in rat uterine morphology and the effect of tamoxifen on sex steroid hormone levels, implantation and myometrial contraction. The results obtained were as follows : 1) The increase in height of the luminal epithelium caused by tamoxifen treatment was blocked by progesterone. The increase in height of luminal epithelium caused by $estradiol-17{\beta}$ treatment was blocked by tamoxifen. 2) When a single dose of tamoxifen(10, 20, $40{\mu}g$) was given on Day 2 of pregnancy, implantation was prevented. Plasma $estradiol-17{\beta}$ level fell in a dose-dependent manner but plasma progesterone level was constant. 3) In vitro, tamoxifen decreased rat uterine contractility in a dose-dependent manner.

  • PDF

질소이온주입에 따른 생체안전성 티타늄 임플란트의 마모특성 (Wear Properties of Biocompatible Ti Implant due to Nitrogen Ion Implantation)

  • 최종운;손선희;변응선;정용수
    • 한국안전학회지
    • /
    • 제14권4호
    • /
    • pp.126-134
    • /
    • 1999
  • In this study, plasma source ion implantation was used to improve the wear properties of biocompatible titanium implant. In order to observe the effect of ion energy and dose on wear property of titanium implant, pin-on-disk type wear tests in Hank's solution were carried out. The friction coefficient of ion implanted specimens were increased from 0.47 to 0.65 under high energy and ion dose conditions. As increasing ion energy and ion dose, the amount of wear was reduced.

  • PDF

질소이온의 주입이 생체안전성 티타늄임플란트의 내식성에 미치는 영향 (Effect of Nitrogen Ion Implantation on Corrosion Resistance of Biocompatible Ti Implant)

  • 최종운;손선희
    • 한국안전학회지
    • /
    • 제14권3호
    • /
    • pp.134-139
    • /
    • 1999
  • In this study, PSII(plasma source ion implantation) was used to improve the biocompatibility of bone-anchored Ti implant. According to potentiodynamic anodic polarization test in deaerated Hank's solution, open circuit potential of ion implanted specimens were increased compare to that of unimplanted specimen ; besides, passive current density and critical anodic current density of ion implanted specimens were lower than unimplanted specimen.

  • PDF

PSII 펄스 시스템의 동적 플라즈마 부하 회로 모델 개발 (Development of a Circuit Model for the Dynamic Plasma Load in a PSII Pulse System)

  • 정경재;최재명;황휘동;김곤호;고광철;황용석
    • 한국진공학회지
    • /
    • 제15권3호
    • /
    • pp.246-258
    • /
    • 2006
  • 음의 고전압의 인가에 따라 반응하는 동적 플라즈마를 부하로 갖는 PSII(plasma source ion implantation) 펄스 시스템을 분석하기 위한 회로 모델을 개발하였다. 플라즈마 내에 삽입된 평판 전극 앞에서의 플라즈마 쉬스의 움직임은 동적 차일드-랑뮤어 쉬스 모델을 따르는 것으로 가정하였다. 표적 전극에 흐르는 전류는 전극에 인가되는 전압과 서로 영향을 주며 변하므로 동적 플라즈마 부하를 전압 의존 전류 원으로 표현하여 자기모순이 없는 회로 모델을 구현하였다. 회로 해석은 Pspice 프로그램을 이용하여 수행하였으며, 다양한 플라즈마 조건과 펄스인가 조건에서의 실험 결과와 비교하여 회로 모델의 타당성을 검증하였다.

Effects of plasma Immersion ion Implanted and deposited layer on Adhesion Strength of DLC film

  • Yi Jin-Woo;Kim Jong-KuK;Kim Seock-Sam
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2004년도 학술대회지
    • /
    • pp.301-305
    • /
    • 2004
  • Effects of ion implantation on the adhesion strength of DLC film as a function of ion doses and implanted energies were investigated. Ti ions were implanted on the Si-wafer substrates followed by DLC coating using ion beam deposition method. Adhesion strength of DLC films were determined by scratch adhesion tester. Morphologies and compositional variations at the different ion energies and doses were observer by Laser Microscope and Auger Electron Spectroscopy, respectively. From results of scratch test, the adhesion strength of films was improved as increasing ion implanted energy, however there was no significant evidence with ion dose.

  • PDF

PIII&D(Plasma Immersion Ion Implantation & Deposition) 공정으로 제조된 인공 관절용 NbN 박막코팅층의 특성 평가

  • 박원웅;최진영;전준홍;임상호;한승희
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.349-349
    • /
    • 2011
  • 인공관절은 노인성 질환이나 자가 면역질환, 신체적인 외상 등으로 인하여 발생하는 관절의 손상 부위를 대체하기 위해 고안된 관절의 인공 대용물이다. 인공 관절 중 인공 고관절의 경우 관절 운동을 하는 라이너(Liner)와 헤드(Head) 부분이 인공관절의 수명을 결정하게 되는데, 헤드 부분에 메탈소재와 라이너 부분에 고분자 소재를 사용하는 MOP(metal on polymer) 구조의 인공관절은 충격흡수의 장점이 있는 반면 wear debris에 의한 골용해로 인하여 관절이 느슨해지는 문제점이 발생하여 재 시술의 주요 원인이 되고 있다. 현재 인공관절의 수명을 늘리기 위해 DLC, ZrO, TiN 등의 높은 경도 값을 갖는 박막을 금속헤드 위에 증착하여 상대재인 인공관절용 고분자 소재의 마모량을 줄이고자 하는 연구가 활발하게 진행되고 있다. 따라서 본 연구에서는 PIII&D(Plasma Immersion Ion Implantation & Deposition)공정을 이용하여 Co-Cr-Mo 합금 소재에 질소 이온을 주입 한 후 NbN 박막을 증착하여 상대재인 초고분자량 폴리에틸렌(UHMWPE)의 마모량을 줄이고자 하였다. NbN 박막의 특성을 평가하기 위해 XRD, XPS, AFM 등의 분석을 수행하였으며, 상대재인 초고분자량 폴리에틸렌의 마모량을 측정하기 위해 Pin-on-disk tribometer를 이용하여 마모 실험을 진행하였다. 마모 실험 결과, NbN 박막을 단순 증착한 경우, 현재 인공관절용 헤드(Head) 소재로 가장 널리 사용되고 있는 Co-Cr-Mo 합금에 비하여, 상대재인 초고분자량 폴리에틸렌의 마모량을 약 20% 감소시키는 것을 알 수 있었다. 또한, Co-Cr-Mo 합금 소재에 질소 이온주입을 하여 표면을 개질한 후, NbN 박막을 증착한 경우, 마모량이 최대 50%까지 감소하는 것을 확인할 수 있었다.

  • PDF