• Title/Summary/Keyword: Plasma Diagnosis

Search Result 345, Processing Time 0.03 seconds

The electrical and optical properties of Xe plasma in flat lamp (평판형 광원에서 제논(Xe) 플라즈마의 전기적 광학적 특성 연구)

  • Pack, Gwang-Hyeon;Yang, Jong-Kyung;Lee, Jong-Chan;Chio, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.60-64
    • /
    • 2005
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important, distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density measured with single langmuir probe in flat lamp, we tested the discharge from 100 Torr to 300 Torr pressure, the Pulse is rectangular pulse with frequency 20kHz and Duty ratio 20%. Resultly, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

Xe Plasma property with flat lamp by Langmuir probe (정전탐침법을 사용한 평판형 광원의 제논(Xe)플라즈마 특성 연구)

  • Pack, Gwang-Hyeon;Yang, Jong-Kyung;Lee, Jong-Chan;Choi, Yang-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.572-573
    • /
    • 2005
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness. life time. efficiency of flat lamp and plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important. When a distance of discharge electrode is 5.5mm and width is 16.5mm. we measured electron temperature and electron density measured with single Langmuir probe in flat lamp. We tested the discharge from 100 Torr to 300 Torr pressure. The pulse type was rectangular with frequency 20kHz and duty ratio was 20%. In result. electron temperature decreases and electron density increased as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

Anti-nuclear antibody-negative immunoglobulin G4-associated autoimmune hepatitis mimicking lymphoproliferative disorders

  • Kang, Min Kyu;Park, Jung Gil;Choi, Joon Hyuk
    • Journal of Yeungnam Medical Science
    • /
    • v.37 no.2
    • /
    • pp.136-140
    • /
    • 2020
  • Immunoglobulin G4 (IgG4)-associated autoimmune hepatitis (AIH) is a very rare subtype of autoimmune hepatitis and characterized by marked elevated serum IgG and hepatic infiltration of IgG4-expressing plasma cells. Pathologic confirmation of hepatic IgG4-expressing plasma cells is usually required for the final diagnosis of IgG4-associated AIH. Herein, we report the case of a 47-year-old female diagnosed with autoantibody-negative IgG4-associated AIH mimicking lymphoproliferative disorders.

Plasma Phosphoproteome and Differential Plasma Phosphoproteins with Opisthorchis Viverrini-Related Cholangiocarcinoma

  • Kotawong, Kanawut;Thitapakorn, Veerachai;Roytrakul, Sittiruk;Phaonakrop, Narumon;Viyanant, Vithoon;Na-Bangchang, Kesara
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1011-1018
    • /
    • 2015
  • This study was conducted to investigate the plasma phosphoproteome and differential plasma phosphoproteins in cases of of Opisthorchis viverrini (OV)-related cholangiocarcinoma (CCA). Plasma phosphoproteomes from CCA patients (10) and non-CCA subjects (5 each for healthy subjects and OV infection) were investigated using gel-based and solution-based LC-MS/MS. Phosphoproteins in plasma samples were enriched and analyzed by LC-MS/MS. STRAP, PANTHER, iPath, and MeV programs were applied for the identification of their functions, signaling and metabolic pathways; and for the discrimination of potential biomarkers in CCA patients and non-CCA subjects, respectively. A total of 90 and 60 plasma phosphoproteins were identified by gel-based and solution-based LC-MS/MS, respectively. Most of the phosphoproteins were cytosol proteins which play roles in several cellular processes, signaling pathways, and metabolic pathways (STRAP, PANTHER, and iPath analysis). The absence of serine/arginine repetitive matrix protein 3 (A6NNA2), tubulin tyrosine ligase-like family, member 6, and biorientation of chromosomes in cell division protein 1-like (Q8NFC6) in plasma phosphoprotein were identified as potential biomarkers for the differentiation of healthy subjects from patients with CCA and OV infection. To differentiate CCA from OV infection, the absence of both serine/threonine-protein phosphatase 2A 56 kDa regulatory subunit beta isoform and coiled-coil domain-containing protein 126 precursor (Q96EE4) were then applied. A combination of 5 phosphoproteins may new alternative choices for CCA diagnosis.

Breakdown Properties in Physiological Saline by High Voltage Pulse Generator

  • Byeon, Yong-Seong;Song, Ki-Baek;Uhm, Han-Sup;Shin, Hee-M.;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.333-333
    • /
    • 2011
  • We have investigated the breakdown properties in liquids by high voltage pulse system. High voltage pulse power system is consisted of the Marx-generator with two capacitors (0.5 ${\mu}F$, withstanding voltage is 40 kV), to which the charging voltage can be applied to maximum 30 kV DC, spark gap switch and charging resistor of 20 $M{\Omega}$. We have made use of tungsten pin electrodes of anode-cathode (A-K), which are immersed into the liquids. The breakdown voltage and current signals are measured by high voltage probe (Tektronix P6015A) and current monitor (IPC CM-1.S). Especially the high speed breakdown or plasma propagation characteristics in the pulsed A-K gap have been investigated by using the high speed ICCD camera. We have measured the electron temperature through the Boltzmann plot method from the breakdown spectrums. Here the A-K gap has been changed by 1 mm, 2 mm, and 3 mm. The used liquids are distilled water and solution of salt (0.9 %). The output voltage and current signals at breakdown in distilled water are shown to be bigger than those in saline solution. The breakdown voltage and current characteristics in liquids will be discussed in accordance with A-K gap distances. It is also found that the electron temperatures and plasma densities in liquids are decreased in conformity with A-K gap.

  • PDF

Application of digital polymerase chain reaction technology for noninvasive prenatal test

  • Lee, Seung Yong;Hwang, Seung Yong
    • Journal of Genetic Medicine
    • /
    • v.12 no.2
    • /
    • pp.72-78
    • /
    • 2015
  • Recently, noninvasive prenatal test (NIPT) has been adopted as a primary screening tool for fetal chromosomal aneuploidy. The principle of NIPT lies in isolating the fetal fraction of cell-free DNA in maternal plasma and analyzing it with bioinformatic tools to measure the amount of gene from the target chromosome, such as chromosomes 21, 18, and 13. NIPT will contribute to decreasing the need for unnecessary invasive procedures, including amniocentesis and chorionic villi sampling, for confirming fetal aneuploidy because of its higher positive predictive value than that of the conventional prenatal screening method. However, its greater cost than that of the current antenatal screening protocol may be an obstacle to the adoption of this innovative technique in clinical practice. Digital polymerase chain reaction (dPCR) is a novel approach for detecting and quantifying nucleic acid. dPCR provides real-time diagnostic advantages with higher sensitivity, accuracy, and absolute quantification than conventional quantitative PCR. Since the groundbreaking discovery that fetal cell-free nucleic acid exists in maternal plasma was reported, dPCR has been used for the quantification of fetal DNA and for screening for fetal aneuploidy. It has been suggested that dPCR will decrease the cost by targeting specific sequences in the target chromosome, and dPCR-based noninvasive testing will facilitate progress toward the implementation of a noninvasive approach for screening for trisomy 21, 18, and 13. In this review, we highlight the principle of dPCR and discuss its future implications in clinical practice.

Interleukin-6-producing paraganglioma as a rare cause of systemic inflammatory response syndrome: a case report

  • Yin Young Lee;Seung Min Chung
    • Journal of Yeungnam Medical Science
    • /
    • v.40 no.4
    • /
    • pp.435-441
    • /
    • 2023
  • Pheochromocytomas and paragangliomas (PPGLs) may secrete hormones or bioactive neuropeptides such as interleukin-6 (IL-6), which can mask the clinical manifestations of catecholamine hypersecretion. We report the case of a patient with delayed diagnosis of paraganglioma due to the development of IL-6-mediated systemic inflammatory response syndrome (SIRS). A 58-year-old woman presented with dyspnea and flank pain accompanied by SIRS and acute cardiac, kidney, and liver injuries. A left paravertebral mass was incidentally observed on abdominal computed tomography (CT). Biochemical tests revealed increased 24-hour urinary metanephrine (2.12 mg/day), plasma norepinephrine (1,588 pg/mL), plasma normetanephrine (2.27 nmol/L), and IL-6 (16.5 pg/mL) levels. 18F-fluorodeoxyglucose (FDG) positron emission tomography/CT showed increased uptake of FDG in the left paravertebral mass without metastases. The patient was finally diagnosed with functional paraganglioma crisis. The precipitating factor was unclear, but phendimetrazine tartrate, a norepinephrine-dopamine release drug that the patient regularly took, might have stimulated the paraganglioma. The patient's body temperature and blood pressure were well controlled after alpha-blocker administration, and the retroperitoneal mass was surgically resected successfully. After surgery, the patient's inflammatory, cardiac, renal, and hepatic biomarkers and catecholamine levels improved. In conclusion, our report emphasizes the importance of IL-6-producing PPGLs in the differential diagnosis of SIRS.

Progesterone assays as an aid for improving reproductive efficiency in dairy cattle II. Use of plasma or milk progesterone profiles for differential diagnosis of ovarian cysts (Progesterone 농도측정(濃度測定)에 의한 유우(乳牛)의 번식효율증진(繁殖效率增進)에 관한 연구(硏究) II. 혈액(血液) 및 유즙(乳汁)중 progesterone 농도측정(濃度測定)에 의한 난소낭종(卵巢囊腫)의 감별진단(鑑別診斷))

  • Kang, Byong-kyu;Choi, Han-sun;Choi, Sang-gong;Son, Chang-ho;Chon, Hong-suk
    • Korean Journal of Veterinary Research
    • /
    • v.34 no.1
    • /
    • pp.181-188
    • /
    • 1994
  • In 60 dairy cows with inactive ovaries, follicular cyst, luteal cyst, persistent corpus luteum and silent heat as diagnosed by rectal palpation, and those that had not resumed ovarian cycles until 60 days postpartum, progesterone concentrations for differential diagnosis of reproductive disorders were measured and were compared in matched plasma, skim milk and milk fat samples at 10 days interval. The incidence rate of reproductive disorders were as follows; inactive ovaries 20(33.3%), silent heat 11(18.3%), follicular cyst 7(11.7%), luteal cyst 7(11.7%), persistent corpus luteum 7(11.7%), pyometra 4(6.7%), vaginitis 2(3.3%), cystic corpus luteum 1(1.7%), and endometritis 1(1.7%), respectively. Cows having a progesterone concentration in plasma and skim milk < 1.0 ng/ml, and in milk fat < 80.0 ng/ml were considered to have inactive ovaries or follicular cyst. Those with concentrations in plasma and skim milk ${\geq}1.0ng/ml$, and in milk fat ${\geq}80.0ng/ml$ were regarded as the cases of luteal cyst or persistent corpus luteum. Progesterone concentrations in above cows did not differ significantly between the time of initial determination and the 10 days after initial determination. But progesterone concentrations in cows with silent heat did differ significantly between the time of initial determination and the 10 days after initial determination(P<0.05). The accuracy of rectal palpation for making a differential diagnosis of ovarian dysfunction, as defined on basis of progesterone concentrations, were as follows; follicular cyst 55.6%, luteal cyst 50.0%, inactive ovaries 90.5% and persistent corpus luteum 60.0%, respectively. It may be concluded that progesterone determinations at 10 days interval is practical as an aid to diagnosing ovarian dysfunction, particularly follicular cyst and luteal cyst.

  • PDF

Plasma Nuclear Factor Kappa B and Serum Peroxiredoxin 3 in Early Diagnosis of Hepatocellular Carcinoma

  • Ismail, Saber;Mayah, Wael;Battia, Hassan El;Gaballah, Hanaa;Jiman-Fatani, Asif;Hamouda, Hala;Afifi, Mohamed A.;Elmashad, Nehal;Saadany, Sherif El
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.4
    • /
    • pp.1657-1663
    • /
    • 2015
  • Background: Early diagnosis of hepatocellular carcinoma (HCC) is the most important step in successful treatment. However, it is usually rare due to the lack of a highly sensitive specific biomarker so that the HCC is usually fatal within few months after diagnosis. The aim of this work was to study the role of plasma nuclear factor kappa B (NF-${\kappa}B$) and serum peroxiredoxin 3 (PRDX3) as diagnostic biomarkers for early detection of HCC in a high-risk population. Materials and Methods: Plasma nuclear factor kappa B level (NF-${\kappa}B$) and serum peroxiredoxin 3 (PRDX3) levels were measured using enzyme linked immunosorbent assay (ELISA), in addition to alpha-fetoprotein (AFP) in 72 cirrhotic patients, 64 patients with HCC and 29 healthy controls. Results: NF-${\kappa}B$ and PRDX3 were significantly elevated in the HCC group in relation to the others. Higher area under curve (AUC) of 0.854 (for PRDX3) and 0.825 (for NF-${\kappa}B$) with sensitivity of 86.3% and 84.4% and specificity of 75.8% and 75.4% respectively, were found compared to AUC of alpha-fetoprotein (AFP) (0.65) with sensitivity of 72.4% and specificity of 64.3%. Conclusions: NF-${\kappa}B$ and PRDX3 may serve as early and sensitive biomarkers for early detection of HCC facilitating improved management. The role of nuclear factor kappa B (NF-${\kappa}B$) as a target for treatment of liver fibrosis and HCC must be widely evaluated.

Plasma Amino Acid and Urine Organic Acid in Diagnosis of MELAS (멜라스 증후군 진단에서의 혈장 아미노산과 소변 유기산 분석)

  • Ji-Hoon Na;Young-Mock Lee
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.23 no.1
    • /
    • pp.17-24
    • /
    • 2023
  • Purpose: In the past, detection of metabolic abnormalities in plasma amino acid (PAA) and urine organic acid (UOA) has been widely used to diagnose clinical mitochondrial diseases, such as mitochondrial encephalomyopathy with lactic acidosis and stroke-like episodes (MELAS). In this study, the diagnostic values of PAA and UOA were reviewed, and their effectiveness in the diagnosis of MELAS was examined retrospectively. Methods: Blood and urine samples at the time of diagnosis were collected from all clinically diagnosed MELAS patients (n=31), and PAA and UOA tests were performed. All samples were collected in a fasting state to minimize artifacts in the results. The difference in the ratio of abnormal metabolites of PAA and UOA at initial diagnosis was statistically compared between the MELAS with genetic confirmation (n=19, m.3243A>G mutation) and MELAS without genetic confirmation (n=12) groups. The MELAS without genetic confirmation group was used as control. Results: Comparison of PAA and UOA between the two groups revealed that no abnormal metabolites showed characteristic differences between gene-confirmed MELAS patients with and those without genetic confirmation. Conclusions: Abnormal values of metabolites in PAA or UOA might be useful as a screening test but are not sufficient to diagnose MELAS patients.

  • PDF