• 제목/요약/키워드: Plasma Arc curing light

검색결과 38건 처리시간 0.173초

IN VITRO PULP CHAMBER TEMPERATURE CHANGE DURING COMPOSITE RESIN CURING WITH VARIOUS LIGHT SOURCES (복합레진 중합 광원에 따른 치수강 온도 변화에 대한 생체외 연구)

  • Lee, Ji-Young;Kim, Dae-Eop;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제31권1호
    • /
    • pp.85-91
    • /
    • 2004
  • The purpose of this study was to observe in vitro pulp chamber temperature rise during composite resin polymerization with various light-curing sources. The kinds of light-curing sources were plasma arc light(P), low heat plasma arc light, traditional low intensity halogen light, low intensity LED(L-LED), and high intensity LED(H-LED). Temperature at the tip of light guide was measured by a digital thermometer using K-type thermocouple. Occlusal cavities$(2{\times}2{\times}1.5mm)$ were so prepared in extracted human premolars as to the remaining dentin thickness was 1mm. Dentin adhesive was applied to all cavities. Experimental groups consisted of no base group, ionomer glass base group, and calcium hydroxide base group. Temperature before and after resin filling was measured. Temperature at the light guide tip was the highest with P and the lowest L-LED. Temperature before resin filling was the highest with H-LED and the lowest with L-LED. Temperature after resin filling was the highest with H-LED and the lowest with L-P and with L-LED. The lining of base partially reduced the temperature rise.

  • PDF

Comparison of the degree of conversion of light-cured resin cement in regard to porcelain laminate thickness, light source and curing time using FT-IR (도재 라미네이트 두께와 광원 및 광조사 시간에 따른 광중합형 레진 시멘트의 FT-IR을 이용한 중합도 비교)

  • Yuh, Chi-Sung;Kim, Jee-Hwan;Kim, Sun-Jai;Lee, Yong-Keun;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제47권4호
    • /
    • pp.416-423
    • /
    • 2009
  • Statement of problem: The degree of light attenuation at the time of cementation of the PLV restoration depends on characteristics such as thickness, opacity and shade of the restorations, which interfere with light transmittance and, as a result, may decrease the total energy reaching the luting cement. Purpose: The purpose of this study was to compare the degree of conversion of light-cured resin cements measuring by FT-IR in regard to different thickness, light devices and curing time. Material and methods: In the control group, a clear slide glass (1.0 mm) was positioned between the light cured resin cement and light source. The specimens of ceramics were made with IPS Empress Esthetic. The ceramics were fabricated with varying thicknesses-0.5, 1.0, 1.5 mm with shade ETC1. Rely $X^{TM}$ Veneer with shade A3, light-cured resin cement, was used. Light-activation was conducted through the ceramic using a quartz tungsten halogen curing unit, a light emitting diode curing unit and a plasma arc curing unit. The degree of conversion of the light-cured resin cement was evaluated using FT-IR and OMNIC. One-way ANOVA and Tukey HSD test were used for statistical analysis ($\alpha$< .05). Results: The degree of conversion (DC) of photopolymerization using QTH and LED was higher than results of using PAC in the control group. After polymerization using QTH and LED, the DC results from the different ceramic thickness- 0.5 mm, 1.0 mm, 1.5 mm- did not show a significant difference when compared with those of control group. However, the DC for polymerization using PAC in the 1.5mm ceramic group showed significantly lower DC than those of the control group and 0.5 mm ceramic group (P<.05). At 80s and 160s, the DC of light-cured resin cement beneath 1.0 mm ceramic using LED was significantly higher than at 20s (P<.05). Conclusion: Within the limitation of this study, when adhering PLV to porcelain with a thickness between 0.5-1.5 mm, the use of PAC curing units were not considered however, light cured resin cements were effective when cured for over 40 seconds with QTH or LED curing units. Also, when curing the light cured resin cements with LED, the degree of polymerization was not proportional with the curing time. Curing exceeding a certain curing time, did not significantly affect the degree of polymerization.

THE COMPARISON OF POLYMERIZATION OF COMPOSITE RESIN INFLUENCED BY CURING DEPTH AND SHADE (광중합 복합레진의 색상과 깊이에 따른 중합도의 비교)

  • Choi, Kung-Ho;Lee, Ju-Hyun;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제31권2호
    • /
    • pp.280-289
    • /
    • 2004
  • Adequate polymerization is a crucial factor in obtaining optimal physical properties and clinical performance of resin composite restorative materials. The purpose of this study was to determine the effectiveness of shade and depth on dental composite resin polymerized with plasma arc curing unit employing FTIR and microhardness. From this experiment, the following results were obtained : 1. The light transmission and microhardness by mode 6 in plasma arc curing were similar to by 20 secs in halogen light curing. 2. The experimental groups of A1, A2, A3, A3.5 were not signifcant difference to light transmission and microhardness on surface and 2mm depth, but were significant difference on 3mm and 4mm depth. Especially light transmission and microhardness were small in darker shade and deeper thickness. 3. Compared with depth cure, uncured monomer amount increased at more than 2mm depth. 4. The light transmission by FTIR and polymerization by microhardness were significant corelation.

  • PDF

A STUDY OF POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN ACCORDING TO FILLING METHODS USING STRAIN GAUGE (스트레인 게이지를 이용한 적층방법에 따른 복합레진의 중합수축에 관한 연구)

  • Kim, Eung-Hag;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제35권1호
    • /
    • pp.18-29
    • /
    • 2008
  • The purpose of this study was to compare the polymerization shrinkage of several filling methods using strain gauges. In this study, a light-emitting diode(LED) curing unit(Elipar Freeligh2, 3M EPSE, USA) and plasma arc lamp(PAL) curing unit(Flipo, LOKKI, France) were used for curing, Filtek $Z350^{TM}$(3M EPSE, USA) composite resin was used for the cavity filling. Sixty permanent bicuspid teeth, that were extracted for orthodontic treatment, were studied. The cavities were prepared on the occlusal surface and were filled using the following methods : 1) bulk filling, 2) parallel filling, 3) oblique filling The strain was recorded on the buccal, lingual, mesial and distal surfaces and the strain values were computed into stress values. The shear bond strength of each filling method was tested using a Micro Universal Testing machine. The results can be summarized as follows: 1. In the strain changes, all LED and PAL curing groups showed an increase on the buccal surface and a slow decrease as time elapsed. 2. In the strain changes of the mesial and distal surfaces, the decreases and increases were shown repeatedly and reduced as time elapsed. 3. There were no significant statistical strain changes among filling methods in the LED or PAL curing groups. 4. There were significant statistical strain changes between the LED and PAL curing groups on the buccal surface(p<0.05). 5. From the shear bond strength results, in the LED curing group, filling method 3 showed lower surface stress than filling method 1 and 2(p<0.05). In the PAL curing group, there were no significant statistical strain changes between each filling method. 6. The surface stress of each group was lower than the shear bond strength.

  • PDF

THERMAL CHANGE AND MICROHARDNESS IN CURING COMPOSITE RESIN ACCORDING TO VARIOUS CURING LIGHT SYSTEM (광중합기에 따른 복합레진 중합시 온도 변화와 미세경도에 관한 연구)

  • Lee, Dong-Jin;Kim, Dae-Eop;Yang, Yong-Sook;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제31권3호
    • /
    • pp.391-399
    • /
    • 2004
  • The purpose of this study was to compare curing efficiency of newly developed curing units to traditional halogen curing unit by measuring thermal change and surface microhardness according to curing light system. Materials and mathods : The types of curing units were traditional low intensity halogen light(Optilux 360), plasma arc light(Flipo), low heat plasma arc light(Aurys), low intensity LED(Starlight), and high intensity LED(Freelight2). Temperature at the tip of light guide was measured by a digital thermometer using K-type thermocouple. And after resin was filled to 2, 3, 4mm teflon mold, bottom temperature measured during curing. After 24 hours, microhardness of top surface and bottom surface of each resin specimen were measured. Results : The result of this study can be summarized as follows, 1. As measuring temperature of curing unit tips, Flipo is the highest as $52.4^{\circ}C,\;Freelight2(37.86^{\circ}C),\;Optilux360(32.68^{\circ}C),\;Aurys(32.34^{\circ}C),\;and\;Starlight(26.14^{\circ}C)$ were followed. 2. Flipo and Freelight2 were the highest similarly and Optilux360 and Aurys were similarly next and Starlight was lowest in temperature of bottom surface of resin mold. 3. Microhardness of top surface were generally similar, and Aurys was relatively low. 4. Optilux 360 and Freelight2 were the highest, and Flipo, Starlight, and Aurys were followed in microhardness of bottom surface. Conclusions : The results suggest that careful use of Flipo and Freelight2 might be able to cure greater depth of resin composite and do not cause thermal problems than other curing units.

  • PDF

A STUDY ON THE EFFECT OF POLYMERIZATION SHRINKAGE OF SEVERAL COMPOSITE RESIN USING STRAIN GAUGE (스트레인 게이지를 이용한 수종 수복재의 중합수축 영향 평가)

  • Lee, In-Cheon;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제36권1호
    • /
    • pp.20-29
    • /
    • 2009
  • This study was performed to evaluate the effect of the shrinkage stress induced by polymerization process of several light curing filling materials according to filling methods. High power light curing unit which has a plasma arc lamp was used and filling materials used were Filtek $Z-250^{(R)}$ composite resin, $Dyract^{(R)}$ AP compomer and $Tetric^{(R)}$ Flow flowable composite resin. Cavities were prepared on the permanent molars with width 3 mm, height 3 mm and depth 1.5 mm and the filling materials were filled with 1 step, 2 step layering technique and 3 step oblique filling methods. The results can be summarized as follows; 1. Strain values showed rapid increase from the start of light curing followed by gradual decrease afterwards with time. 2. Although the shrinkage stress value of $Z-250^{(R)}$ were shown to be relatively higher than $Dyract^{(R)}$ AP and $Tetric^{(R)}$ Flow, no statistically significant could be found between tested materials(p>0.05). 3. There were no statistically significant difference between 3 filling methods when using $Dyract^{(R)}$ AP and $Z-250^{(R)}$(p>0.05). 4. There were no statistically significant difference between shrinkage stress values obtained from samples prepared by different filling methods and materials(p>0.05).

  • PDF

A comparative study on bond strength and adhesive failure pattern in bracket bonding with self-etching primer (Self-etching Primer를 이용한 교정용 브라켓 부착시 전단결합강도와 파절양상에 관한 비교연구)

  • Kim, You-Kyoung;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • 제34권4호
    • /
    • pp.325-332
    • /
    • 2004
  • A self-etching primer that combines the etchant and primer in one chemical compound saves time and should be mote cost-effective to the clinician and patient. The purpose of this study was to evaluate the clinical effectiveness of a self-etching primer by measuring shear bond strengths according to various conditions and observing adhesive failure patterns. For this Investigation, 120 upper and lower premolars extracted for orthodontic purposes were used and randomly divided into six groups of twenty teeth each. Human premolars were embedded in a metal cylinder with orthodontic resin. Metal brackets and ceramic brackets were bonded with XT primer and self-etching primer by means of XT adhesive. Upon curing, plasma arc light and visible light were used. After bonding, the shear bond strength was tested by Instron universal testing machine, and the amount of residual adhesive that remained on the tooth after debonding was measured by stereoscope and assessed with an adhesive remnant index. The results were as fellows: 1. When brackets were bonded, if other conditions remained the same, there was no significant difference in shear bond strength due to the type of primer - either self-etching primer or XT primer. 2. When metal brackets were bonded, there was no significant difference in shear bond strength according to the source of light - plasma arc light or visible light - and type of primer. 3. There was a very significant difference in shear bond strength according to the type of brackets - metal or ceramic brackets. The shear bond strength of ceramic brackets was stronger than metal brackets. 4. When the adhesive failure patterns of metal brackets bonded with self-etching primer were observed by using the adhesive remnant index, the bond failure of the metal bracket occurred more frequently at the bracket-adhesive. The failure of the ceramic bracket, however, occurred more frequently at the enamel-adhesive interface. The adhesive failure patterns of metal brackets bonded with XT primer observed the same patterns. The above results suggest that self-etching primer can be clinically useful for bonding the brackets without fear of a decrease in shear bond strength.

THE TEMPERATURE RISING IN PULP CHAMBER DURING COMPOSITE RESIN POLYMERIZATION (광중합 기전에 따른 복합레진 중합 시 치수강 내 온도변화)

  • Hwang, Dong-Hwan;Lee, Ju-Hyun;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제30권3호
    • /
    • pp.431-438
    • /
    • 2003
  • This study investigates pulp chamber temperature rise during composite resin polymerization by plasma arc(Group III : Flipo 3 sec, Group IV : Flipo 5 sec) and LED curing units(Group V : Lux-O-Max, 40 sec) as well as conventional halogen lamp curing units(Group I : VIP mode3, 20 sec, Group II : VIP mode6, 20 sec). The results are as follows : 1. All of the investigated pulp chamber temperature rises are lower than the boundary temperature could result in irreversible damage to the pulpal tissue ($5.5^{\circ}C$). 2. In the group II, it is found the significantly higher pulp chamber temperature rise than any other groups(p<0.05). 3. In the group of composite resin light-cured with VIP, it is found the significantly higher pulp chamber temperature rise in the group II than group I(p<0.05). 4. In the group of composite resin light-cured with Flipo, it is found the significantly higher pulp chamber temperature rise in the group IV than group III (p<0.05). 5. In the case of comparing VIP and Flipo, group II is significantly higher pulp chamber temperature rise than group III, IV(p<0.05), and group IV is significantly higher pulp chamber temperature rise than group I(p<0.05), and it does not significantly differ between group I and III. 6. In the group of composite resin light-cured with Lux-O-Max, it is found the significantly lower pulp chamber temperature rise than any other groups (p<0.05).

  • PDF