북제주화력 발전제어설비에 대한 최적 DCS 개발 (Development of Optimal DCS in Bookjeju fossil Plant Control System)

  • 이주현;정창기;류홍우;김관행
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 B
    • /
    • pp.663-666
    • /
    • 1997
  • This paper presents the development of Distributied Control System for Bookjeju fossil plant. The original analog control system for the power plants has a complex and large-scale structure in their hardware configuration and much difficulties have been experienced for maintenance due to lack of original components. This system connects three different control systems in Bookjeju fossil plant by cue network, The result shows that optimal Distributied Control System has standardization of control system, effective operation management and convenient maintenance of power plant.

  • PDF

화력발전설비 진단기술 및 전문가 시스템개발에 관한 연구 (A study on the developing the diagnosis technology and expert system in fossil power plant)

  • 백영민;정희돈;신은주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.642-648
    • /
    • 2008
  • In order to analyze the causes of fossil power plant facilities due to a degradation and corrosion, artificial degraded materials composed of the facilities were manufactured. Various experiment were performed based on mechanical test, microstructure observation, hardness test, electrochemical potentiokinetic reactivation test(EPR) and corrosion scale thickness measurement test. The master curves were write out using Larson-Miller parameter to evaluate the degree of degradation with the above diagnosis methods. These data were applied to materials database of fossil power plant diagnosis. Finally expert system on the fossil power plant diagnosis was developed using the master curves and diagnosis algorithms.

  • PDF

대규모 해수담수화 플랜트에서의 전처리공정 비용 분석 (Cost comparison of pretreatment processes in large SWRO desalination plant)

  • 김영민;김진호;이상호;이창규;박광덕;최준석
    • 상하수도학회지
    • /
    • 제27권5호
    • /
    • pp.555-560
    • /
    • 2013
  • A cost analysis method for pretreament processes of a large scale seawater desalination plant was considered using a cost estimation model, WaTER (Water Treatment Estimation Routine). This model is based on cost functions of U.S. EPA to conduct economic analysis of water treatment facilities. A virtual seawater desalination plant which has pretreatment production capacity of $100,000m^3$ per day was chosen as a model plant. Dual media filtration and microfiltration systems were compared as pretreatment process, and the following reverse osmosis process was modeled. As a result, microfiltration showed a price competitiveness in condition of operating with reverse osmosis process by reducing the loads of water treatment and membrane cleaning despite it's high annual cost.

Improvement of Antigen Blotting in a Tissue Blot Immunobinding Assay for the Detection of Two Chili Pepper Viruses

  • Han, Jung-Heon;Shin, Jun-Sung;Kim, Young-Ho;Kim, Byung-Dong
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권11호
    • /
    • pp.1885-1889
    • /
    • 2007
  • The tissue blot immunobinding assay (TBIA) is widely used for the detection and localization of plant viruses in various plant tissues. The basic experimental procedures of TBIA sampling and blotting were simplified using commercially available micropipette tips. This method was termed the ring-blot immunobinding assay (R-BIA), as the blot on the membrane forms a ring shape. The detection efficacy of R-BIA was tested for two chili pepper viruses, pepper mild mottle tobamovirus (PMMoV) and pepper mottle potyvirus (PepMoV), following the optimized serological procedures of TBIA (length of the incubation period and BSA concentration, and primary and secondary antibodies). Sensitivity of the R-BIA was about 1 ng/ml of purified PMMoV in pepper leaf sap from a healthy pepper plant. R-BIA also showed high specificity in the detection of PMMoV and PepMoV. Moreover, the modified sampling and blotting procedures were simpler and more reliable than other TBIA methods (such as whole-leaf blotting and crushed-leaf blotting), suggesting that the R-BIA may be used for medium- to large-scale detection of plant viruses in laboratories with minimal facilities.

단지규모 개발사업의 지속가능성 확보를 위한 녹지 평가 모형 개발 (Development of Evaluation Model on Greenspace for Sustainability of Site-scale Development Projects)

  • 양병이;이관규
    • 한국조경학회지
    • /
    • 제28권2호
    • /
    • pp.97-107
    • /
    • 2000
  • This study aims to develop the model of evaluation on greenspace to increase the sustain ability of the planning and management for site-scale development projects. The results of this study can be summarized as follows: (1) The comprehensive principles of sustainable development projects were established, which include coexistence of man and nature, reflection of ecological principles, minimization of environmental pollution and damage, recycling and reuse of materials. (2) According to established principles, the evaluation criteria were classified into seven categories as follows: retention of ample greenspace, formation of greenspace as a habitat, species diversity of vegetation, consideration of indigenous plants, construction of green network, conservation of greenspace, and reuse of plant materials. (3) As a result of the analysis of questionnaire of experts, evaluation model was worked out with which we can evaluate environmental friendliness greenspace. And, the final evaluation indicators for greenspace are the rate of greeneries volume, securing habitat, indigenous plants, reuse of plant materials, and species diversity of vegetation, and the indicator of greenspace conservation.

  • PDF

Pilot plant 규모 유동충 소각로의 제지 슬러지 소각 용량에 관한 실험적 연구 (Experimental study on the capacity of pilot scale FBC for paper sludge)

  • 라승혁;문동진;강경태;신동훈;황정호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제24회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.199-203
    • /
    • 2002
  • In this paper, the effects of water contents on combustion characteristics of paper sludge and capacity of fluidized bed combustor(FBC) were investigated using 0.26m diameter, 1.75m height pilot-plant scale combustor. Combustion tests of paper sludge containing water contents between 40wt% and 50wt% were performed. The temperature and emission variation, the pressure inside combustor were measured to monitor the fluidization quality. The experimental results showed that 30kg/hr feeding rate of sludge containing water up to 45wt% was preferable for this system. Sludge loading rate, heat release rate were calculated from experimental data as major parameters showing FBC capacity. Comparsion with sludge loading rate from other source was also performed

  • PDF

대규모 태양광 발전설비를 위한 전력변환기 개발 (Development of 250kW Power Conditioning System for Large Scale Photovoltaic Power Plant)

  • 강호현;정홍주;김왕문;서인영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.640-642
    • /
    • 2008
  • This paper presents the design, development and performance of a 250kW power conditioning system(PCS) for large scale photovoltaic power plant. The PV inverter consists of a three phase IGBT stack, L-C filter, transformer and HMI unit for monitoring. To verify the performance of the PV inverter a testing facility was designed and constructed to simulate the characteristics of the solar cell and grid.

  • PDF

Characterization of Microbial Community in Biological Wastewater Treatment System Using Respiratory Quinone Profiles

  • Lim Byung-Ran;Ahn Kyu-Hong;Lee Yonghun
    • 한국미생물학회:학술대회논문집
    • /
    • 한국미생물학회 2003년도 International Meeting of the Microbiological Society of Korea
    • /
    • pp.111-114
    • /
    • 2003
  • The dynamics of microbial community structure of the various domestic wastewater treatment processes were examined using a novel approach of quinone profiles. The compositions of microbial quinone of 5 sites fer plant and lab-scale activated sludge were analyzed. More than 14 kinds of quinones were observed in the activated sludges tested in this study. The microbial community structure of the plant activated sludge processes a little differed from that of the lab-scale submerged MBR systems. The dominant quinones were UQ-8, UQ-10 followed $MK-8(H_4)$, MK-7 and MK-6. The molar ratio of ubiquinones to menaquinones (UQ/MK) changed from 0.81 to 1.9, indicating that aerobic bacteria dominated the microbial community of the activated sludge examined. The microbial diversity of the activated sludges calculated from the all quinone compositions was 9.5-11.9 and the microbial equability of the activated sludges was 0.64-0.79.

  • PDF

한국산 뿔밀깍지벌레에 대한 정리 (노린재목, 밀깍지벌레과) (Notes on the Indian wax scale, Ceroplastes ceriferus (Fabricius), from Korea (Hemiptera: Coccidae))

  • 이용현;;서수정
    • 한국응용곤충학회지
    • /
    • 제51권2호
    • /
    • pp.157-162
    • /
    • 2012
  • 뿔밀깍지벌레(Ceroplastes ceriferus (Fabricius))는 형태적으로 유사한 C. pseudoceriferus Green과 혼동되어 동정되었으며, 이에 뿔밀깍지벌레에 대한 형태적 특징을 재기재하였다. 이와 더불어 한국산 밀깍지벌레속(屬)의 3종을 동정하기 위한 검색표, 사진 및 DNA바코드 정보도 함께 제공하였다.

Pilot 규모 2단 형상 가스화기 운전특성 실험 (The operation Characteristic of Pilot-scale 2-Stage Coal gasifier)

  • 홍진표;정재화;서석빈;지준화;이승종;정석우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.528-532
    • /
    • 2009
  • Integrated Gasification Combined Cycle (IGCC) power plant converts coal to syngas, which is mainly composed with hydrogen and carbon monoxide, by the gasification process and produces electric power by the gas and steam turbine combined cycle power plant. The purpose of this study is to investigate the influence of gasification process to type and structure of gasifier. For this purpose, the performance characteristics of gasification reaction are analyzed with the operation characteristic of pilot-scale 2-stage coal gasifier. It is found that gasification reaction, floating characteristic of melted slag, particle stick of inside of the gasifier, particle stick and deposit of Syngas cooler are the causes in the different performance characteristics.