• 제목/요약/키워드: Plant location

검색결과 587건 처리시간 0.027초

수정된 Steiner Point를 이용한 Batcher Plant의 최적 위치 선정 (Optimal location of Batcher Plant using Modified Steiner point)

  • 하권열;이상중
    • 조명전기설비학회논문지
    • /
    • 제29권10호
    • /
    • pp.39-46
    • /
    • 2015
  • REMICON(Ready Mixed Concrete), the most essential material of construction work, is produced from facility called "Batcher plant." In order to produce Remicon, Batcher Plant needs to be supplied with basic raw material such as ballast, sand, cement, admixture and water. In remicon industry, overland transport vehicles are used during the whole manufacturing process from producing to infilling at the construction site. Thus, the transportation cost sums up be to 20 percent of whole manufacturing cost and transport capacity and distance travelled have direct and major effect on manufacturing costs. This paper suggests a method to find optimal location of batcher plant using modified Steiner point, suggesting the most effective and flexible connection through among construction site, aggregate, cement and remicon producing plant. This paper also proposes reducing of transport cost at maximum 60% by calculation through optimized plant location. The modified Steiner point theory proposed in this paper also can be applied to optimal location of a $2^{ry}$ substation or MCC panel for minimizing of power loss, voltage drop, line distance and etc.

Multicriteria Quadratic Plant Location Problem

  • Arora, Sudha;Arora, S.R.
    • Management Science and Financial Engineering
    • /
    • 제14권1호
    • /
    • pp.65-86
    • /
    • 2008
  • In this paper, we have considered the multicriteria quadratic plant location problem. In addition to the allocation costs, the maintenance costs of the plants are also considered. The objective functions considered in this paper are quadratic in nature. The given problem is reduced to the problem with linear objective function. The method of Fernandez and Puerto (2003) is applied to solve the reduced problem. It is illustrated with help of examples. The effect of the change in the allocation and maintenance costs on allocation of plants to the clients has also been discussed.

韓國 纖維工業의 技術變化와 立地에 관한 연구 (A study on the technological and locational changes of textile industry in Korea)

  • 김선배
    • 대한지리학회지
    • /
    • 제38권
    • /
    • pp.37-59
    • /
    • 1988
  • The aim of this study is to investigate the influence of the technological changes on locational changes on the assumption that technological changes cover over all industrial sectors. The study is carred on 1) To investigate the theoretical backgrounds of the technological and locational changes and their problems. 2) To investigate the location and economic characteristics of the Korean textile industry. 3) To investigate the technological development and regional variations in technological level. 4) To the relationship of the technological change to the location of the textile industries. The locational change of the Korean textile industries have been closely related to economic characteristics. In the begining stage of development in the 1950's, thetextile industries were largely concentrated in the major cities(Seoul, Pusan, Taegu, Masan et. al.). In the growing stage of development in the 1960's, the textile industries were relocated in suburban areas with the trend of large corporations building their branch plants of chemical fibers in the suburbs. With the expansion in the export industry in the 1970's, the textile companies were distributed throughout the whole country. But the research and development(R&D) activities caused the textile industries reconcentrate around Seoul and Pusan, owining to the change of the economic environments in the 1980's. The 1980's have witnessed the increased R&D investment for the development of better new and value-added products. This was because the technological level was much higher than that of Taegu and Other regions. What is more, plant birth location and branch plant location support that locational changes of textile industry were caused by technological changes. Plant birth location put stress technological environments of region, compared with branch plant locaiton. Accordingly, the technological changes of industry can be an important factor in locational changes. Through this study, it can be seen that locational changes come from technological changes. Other locational factors influence the industrial locations, but regional variations in technological level which has been relatively ignored has to be considered on the location study. Together with the accomplishments of existing location study, the study on technological change and location can better explain the location phenomena. And further research on technological change and location can provide better policy implications for regional development.

  • PDF

석유화학업체의 플랜트 입지 선정의 중요성에 대한 연구 (The importance of plant location decision-making in the petrochemical industry)

  • 정윤정;우수한;박근식
    • 한국항만경제학회지
    • /
    • 제31권1호
    • /
    • pp.127-145
    • /
    • 2015
  • 석유화학산업은 대규모 설비 투자비용이 소요되는 자본 및 기술집약적 장치산업으로 공급사슬 내 구성원 간의 협력과 통합을 통한 경쟁력 강화를 추구하고 있어 입지선정시 공급업체와 생산업체, 고객의 지리적 위치와 연결성을 고려한 물류요인이 중요해지고 있다. 따라서 본 연구에서는 다중적 의사결정 기준을 반영하여 입지 선정요인의 상대적 중요성을 평가하고 그 중에서 물류요인의 중요성의 분석 및 국내 주요플랜트 입지 후보지를 평가하는 것을 목적으로 한다. 본 연구는 석유화학플랜트 입지선정 요인의 우선순위를 연구함에 있어 물류적 요인이 다른 산업경제학적인 요인과 비교하여 어떠한 중요성을 가지는지 분석한 연구로서 의의가 있다. 또한 도출된 상대적 중요성을 바탕으로 현재 석유화학단지의 입지를 평가했다는데 의의가 있다. 이는 석유화학기업들이 향후 플랜트 입지를 신규로 선정할 경우 물류적인 요인을 중요하게 고려해야 할 것이며, 정부나 지방자치 단체가 석유화학단지를 조성하거나 유치할 경우 물류비, 물류연계성과 같은 물류적인 기반이 확보되어야 한다는 시사점을 제공할 수 있다.

농공지구 입지분석 : 전라북도의 경우 (Locational Analysis of Rural Industrial Estates and Chonbuk Economic Development Strategies)

  • 박임구;백영기;장재우
    • 지역연구
    • /
    • 제9권2호
    • /
    • pp.103-119
    • /
    • 1993
  • This research examines the spatial development of rural industrial estates (Nong-gong Jigu) in Chonbuk province and gives insight into the strategies for economic development in the entire region. Selected location factors which are likely to pull new investment into the estates are examined by using questionnaires. Few loction factors except nonlocal factors can be found in explaining why location choices are made. The irrelevance of the analysis based on location factors suggests that an alternative approach should analyze changes in the spatial development of the rural industrial estates. Such an alternative is to understand the dynamics of the spatial organization of production by focusing on characteistics of plant closing in the rural industrial estates. To take into account of the characteristics of plant closing we provide the hypothesized relationships between employment size, organizational structure, inter and intra industrial linkage, characteristics of production processes, and availability of local labor market and the likelihood of closing. A logit model is then made to identify the selected factors which might influence the probability of plant closing. The results from the logit analysis and their implications suggest that the policy should be more concerned with the characteristics of firms, such as size and ownership, as well as of the local labor markets. Given that the Chonbuk region has experienced rapid population decline, together with its poor industrial base, it seems that the success of the policy in the declined rural areas in less certain.

  • PDF

Choosing an optimal connecting place of a nuclear power plant to a power system using Monte Carlo and LHS methods

  • Kiomarsi, Farshid;Shojaei, Ali Asghar;Soltani, Sepehr
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1587-1596
    • /
    • 2020
  • The location selection for nuclear power plants (NPP) is a strategic decision, which has significant impact operation of the plant and sustainable development of the region. Further, the ranking of the alternative locations and selection of the most suitable and efficient locations for NPPs is an important multi-criteria decision-making problem. In this paper, the non-sequential Monte Carlo probabilistic method and the Latin hypercube sampling probabilistic method are used to evaluate and select the optimal locations for NPP. These locations are identified by the power plant's onsite loads and the average of the lowest number of relay protection after the NPP's trip, based on electricity considerations. The results obtained from the proposed method indicate that in selecting the optimal location for an NPP after a power plant trip with the purpose of internal onsite loads of the power plant and the average of the lowest number of relay protection power system, on the IEEE RTS 24-bus system network given. This paper provides an effective and systematic study of the decision-making process for evaluating and selecting optimal locations for an NPP.

A leak detection and 3D source localization method on a plant piping system by using multiple cameras

  • Kim, Se-Oh;Park, Jae-Seok;Park, Jong Won
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.155-162
    • /
    • 2019
  • To reduce the secondary damage caused by leakage accidents in plant piping systems, a constant surveillance system is necessary. To ensure leaks are promptly addressed, the surveillance system should be able to detect not only the leak itself, but also the location of the leak. Recently, research to develop new methods has been conducted using cameras to detect leakage and to estimate the location of leakage. However, existing methods solely estimate whether a leak exists or not, or only provide two-dimensional coordinates of the leakage location. In this paper, a method using multiple cameras to detect leakage and estimate the three-dimensional coordinates of the leakage location is presented. Leakage is detected by each camera using MADI(Moving Average Differential Image) and histogram analysis. The two-dimensional leakage location is estimated using the detected leakage area. The three-dimensional leakage location is subsequently estimated based on the two-dimensional leakage location. To achieve this, the coordinates (x, z) for the leakage are calculated for a horizontal section (XZ plane) in the monitoring area. Then, the y-coordinate of leakage is calculated using a vertical section from each camera. The method proposed in this paper could accurately estimate the three-dimensional location of a leak using multiple cameras.

구미하수처리장 방류구에서의 소수력발전 설치 및 운영에 관한 연구 (Feasibility Study on the Construction of Small Hydro-Power Plants in Gumi Sewage Treatment Plant Discharge Point)

  • 나동훈;이승환
    • 상하수도학회지
    • /
    • 제24권2호
    • /
    • pp.173-181
    • /
    • 2010
  • This study was conducted to investigate the possible installation of small hydro-power plant at the discharge point of Gumi sewage treatment plant (STP) using treated wastewater. Sufficient amount of water to transfer to electric power and the selection of proper location are two essential elements for the construction of small hydro-power facility. Preliminary analysis based on site visit and existing data in Gumi STP were made. Capacity of the small hydro-power plants and exact location were determined by geomorphological condition and flow duration characteristics. Flow duration characteristics and its duration curve were identified using monthly rainfall data in Gumi STP. Relevant facts of small hydro-power system in other STP were referred to adopt to Gumi STP situation. Flowrate of treated effluents and effective head between flow chamber and the location of hydraulic turbine in Gumi STP are found to be $3.70m^3$/sec and 3.5m respectively. Electric generation rate based on this feasibility study was estimated to be 86.3kW/h. Yearly electric generation rate was expected to be 932.4MMh. Proposed small hydro-power plant construction in Gumi STP is to be reasonable.

하수처리장 폭기조의 용존산소농도 모니터링 대표지점 선정에 관한 연구 (A study on the determination of a representative location for monitoring the dissolved oxygen concentration in a aeration tank of sewage treatment plant)

  • 방석용;범봉수;김진한
    • 상하수도학회지
    • /
    • 제33권5호
    • /
    • pp.389-394
    • /
    • 2019
  • In order to determine the location of average concentration and distribution status of dissolved oxygen in the rectangular aeration tank of the sewage treatment plant was analyzed and the difference of dissolved oxygen concentration was remarkable at each location. Compared with the computational fluid dynamics analysis, it was found that the results were consistent with the measurement results by showing the difference of dissolved oxygen concentration between the locations. Based on the measured data, the representative location of dissolved oxygen in aeration tank was selected by using statistical analysis method and the representative location was expressed in three-dimensional coordinates(LWH : 25%, 50%, 33%) from flow direction and left wall. Also the difference between the dissolved oxygen concentration at the actual measurement location and the average concentration value of the entire aeration tank was founded, and the equations for calibrating the automatic measurement data considering the actual measurement location were calculated.

공기챔버 위치에 따른 폰툰형 초대형 구조물 유탄성응답 해석 (Hydroelastic Analysis of Pontoon Type VLFS Considering the Location and Shape of OWC Chamber)

  • 홍사영;경조현;김병완
    • 한국해양공학회지
    • /
    • 제22권1호
    • /
    • pp.22-29
    • /
    • 2008
  • A numerical investigation is made on the effects of the location and shape of the front wall of an OWC(Oscillating Water Column) chamber on the hydroelastic response of a VLFS. Most of the studies on the effects of an OWC chamber on the response of a VLFS have assumed the location of the OWC chamber to be at the front of the VLFS. In the present study, an OWC-chamber is introduced at an arbitrary position in relation to a VLFS to determine the influence of the location and shape of the OWC chamber on the hydroelastic response of the VLFS. A finite element method is adopted as a numerical scheme for the fluid domain. or the finite element method, combined with a mode superposition method, is applied in order to consider the change of mass and stiffness The OWC chamber in a piecewise constant manner. or the facilitated anefficient analysis of The hydroelastic response of the VLFS, as well as the easy modeling of different shape and material properties for the structure. Reduction of hydroelastic response of the VLFS is investigated for various locations and front wall shapes of the owe chamber.