• Title/Summary/Keyword: Plant Simulation

Search Result 1,748, Processing Time 0.031 seconds

POWER SYSTEM STABILITY ANALYSIS ON PETROCHEMICAL PLANT;MEXICO CADEREYTA CASE (석유화학공장의 전력계통 안정도 해석;맥시코 카데래이타 경우)

  • Kim, Bong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1224-1226
    • /
    • 1999
  • When electrical engineers get started with the design of main electrical system of a complex petrochemical plant along with chemical and mechanical engineers, they are usually confronted with lack of power system data. This paper presents a procedure how to perform power system stability analysis for the purpose of design studies within the limited system data given and to verify the given data to get reliable convergence in dynamic simulation as well as to apply the stability analysis result on practical system design. The power system stability analysis on the Cadereyta petrochemical plant in Mexico is provided as a study case.

  • PDF

Robust Control of Uncertainty Systems by Fuzzy Auto-Tuning (Fuzzy 자동동조에 의한 불확실성 공정의 견실제어)

  • Ryu, Y.G.;Choi, J.N.;Kim, J.K.;Mo, Y.S.;Hwang, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.504-506
    • /
    • 1999
  • In this paper, we propose a method which control parametric uncertainty systems using PID controller by fuzzy auto tuning. We get the error and the error change rate of plant output correspond to the initial value of parameter using the Ziegler-Nickols tuning and determine the new proportional gain$(K_p)$ and the integral time $(T_i)$ from fuzzy tuner by the error and error change rate of plant output as a membership function of fuzzy theory. The Fuzzy Auto-tuning algorithm for PID controller operate to adapt variable parameter of plant in parametric uncertainty systems. It is shown this method considerably improve the transient response at computer simulation.

  • PDF

Numerical Investigation of the Flow and Mixing Characteristics with the Static Mixer in a Catalytic Combustor for the MCFC Power Plant System (MCFC 발전시스템 적용 촉매연소기의 혼합 특성 향상을 위한 Static Mixer의 유동에 관한 수치적 연구)

  • Kim, Chong-Min;Park, Nam-Seob;Kim, Man-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.3
    • /
    • pp.149-155
    • /
    • 2009
  • In this work a numerical study to find the characteristics of the internal flow and mixing process has been conducted in a static mixer used in the system of catalytic combustor of the fuel cell power plant. After introducing the model description and final governing equations the present numerical approach is applied to the analysis of static mixer, which may have one or more helical elements inside the circular tube by changing such various parameters as incoming mass flow rates and the number of helical elements. The results show that although the static mixer is efficient in mixing fuel and air, more optimization processes are required to achieve the appropriate mixing characteristics in front of the honeycomb type catalytic combustor used in the MCFC power plant

A design on robust integral-type optimal model following servo system (강인한 적분형 최적 모델 추종형 서보계의 구성에 관한 연구)

  • 황창선;김정택;이양우;최일섭
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.1024-1027
    • /
    • 1992
  • This paper deals with design method of the model following servo system in which optimal regulator probelm is used to design the controllers that make the step/ramp response of the plant be keptclose to a specified ideal step/ramp response of the model. The characteristics of this system is robust in the presence of the specified disturbances or the partameter perturbations of the plant. Especially, by direct feedforward compensator from the reference input the steady state offset of plant output response is excluded and the transient response is improved. Examples are give and the results of the design of the model follwing servo systems are verified by the computer simulation.

  • PDF

H-infinity Control System Design for a Quad-rotor (쿼드로터의 H-infinity 제어시스템 설계)

  • Kang, Taesam;Yoon, Kwang Joon;Ha, Tae-Hyun;Lee, Gigun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.1
    • /
    • pp.14-20
    • /
    • 2015
  • This paper describes the design of a robust H-infinity attitude controller for a quad-rotor. The linear model of a quad-rotor was estimated using PEM (Prediction Error Minimization) method with experimental input and output data. To design an attitude controller, an extended plant was constructed by adjusting several uncertainties and weighting functions. An H-infinity controller was obtained by applying H-infinity methodology to the extended plant. Through frequency-domain analysis, it was shown that the designed controller can overcome uncertainties up to 75% of the plant model. The performance and robustness of the controller were verified through time-domain simulation.

Improvement of a PID Function Block of a Domestic DCS (국산 분산 제어 시스템의 PID 기능 블럭 개선)

  • 변승현;마복렬
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.151-154
    • /
    • 2000
  • Used analog control systems have been converted into digital control systems due to performance degradation and difficulty of maintenance. There are few domestic DCS (Distribued Control System)s that have been applied to Bower plant. To apply a demestic DCS to power plant, the reliability, redundacny, and fault tolerance of DCS is important. Besides those items, the control action of control function block is also important. In this paper, we describe the requirements that PID control function block has to have, and implement a PID control function block that satisfies those requirements. Finally. simulation result using digital simulator for boiler system in thermal power plant shows the validity of a implemented PID control function block.

  • PDF

Modeling of SO$_2$ Emissions from Yatagan Power Plant

  • Im, Ulas;Yenigun, Orhan
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.69-72
    • /
    • 2003
  • The meteorological model, CALMET, and its plume dispersion model, CALPUFF, were used in order to simulate the dispersion of $SO_2$ emitted from Yatagan Power Plant and its effect on Yatagan district in the episodic event on December 2 and 3, 2000. It is found that south westerly and light winds and the nighttime surface inversion layers lead to accumulation of pollutants over Yatagan district. The results are compared with the measurements done by Local Environmental Authorities of Mu la. The simulation results indicate that the maximum ground level concentrations were found northeast from the source, which agrees with experimental measurement. On the other hand, the magnitude of results obtained with the model shows some differences compared with experimental measurements.

  • PDF

A Study on The Steam Generator Level Control for Nuclear Power Plant (원자력발전소 증기발생기 수위 제어에 관한 연구)

  • Moon, Byung-Heuee;Choi, Hong-Kyoo
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.172-174
    • /
    • 1995
  • About a half of Electric power is generated by nuclear power plants in korea. So, the stable operation of nuclear power plant is very important for suppling the essential national electric power. A S/G(Steam Generator) level control is the most difficult system in PWR(Pressurized Water Reactor) nuclear power plant. Because of the non-linear and the non-nominal response of S/G level control, it Is very difficult to control the level by automatic mode or manual mode. The goal of this study is to establish and verify a advanced control algorithm by analyzing, modelling, stability calculation, controller parameter calculation, simulation for S/G level control system.

  • PDF

Thermal Performance Simulation of Cogeneration Power Plants (열병합 발전플랜트의 열성능 해석)

  • Lee, Dong-Won;O, Myeong-Do;Lee, Jae-Heon;Jo, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.451-460
    • /
    • 2001
  • An analysis program for the thermal performance prediction of steam turbine cogeneration systems with multi-extraction, reheat and regeneration has been developed on the basis of the thermodynamic heat balance method. Heat balance analyses were performed for a commercial cogeneration power plant using the program. Its appropriateness was verified by comparing its heat balance results with those of other commercial programs and those provided by the original system designer. Further parametric analyses were carried out and performance improvement measures in designing the plant were suggested.

Modelling of Power Plant Fan Pitch Blade Control Actuator (전력설비 대용량 보일러 통풍기 날개각 제어 작동기 모델링)

  • Huh, J.Y.;Son, T.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.2
    • /
    • pp.28-33
    • /
    • 2007
  • In the power plant facility which use soft coal as a power source the fan pitch blade control hydraulic actuator is used to control the inlet and outlet gas to regulate the internal pressure of the furnace and control the frequence. Sometimes malfunctions of this equipment lead to the decline of boiler thermal efficiency and unexpected power plant trip. In order to localize the fan pitch blade control hydraulic actuator specially for the 500MW large scale boiler, Analysis and modelling of the system is carried out mathematically. The responses of the system are examined by using matlab simulation fur the variation of the major parameters in view of reverse engineering. Consequently the validity of the established parameters are examined.

  • PDF