• Title/Summary/Keyword: Plant Simulation

Search Result 1,738, Processing Time 0.028 seconds

Generalized predictive control of P.W.R. nuclear power plant (일반화된 예측제어에 의한 가압경수형 원자로의 부하추종 출력제어에 관한 연구)

  • 천희영;박귀태;이종렬;박영환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.663-668
    • /
    • 1990
  • This paper deals with the application of a Generalized Predictive Control (CPC) to a Pressurized Water Reactor (P.W.R) Nuclear Power Plant. Generalized Predictive Control is a sort of Explicit Self-Tuning Control. Current self-tuning algorithms lack robustness to prior choices of either dead-time (input time delay of a plant) or model order. GPC is shown by simulation studies to be superior to accepted self-tuning techniques such as minimum variance and pole-placement from the viewpoint that it is robust to prior choices of dead-time or model order. In this paper a GPC controller is designed to control the P.W.R. nuclear power rlant with varying dead-time and through the designing procedure the designer is free from the constraint of knowing the exact dead-time. The controller is constructed based on the 2nd order linear model approximated in the vicinity of operating point. To ensure that this low-order model describes the complex real dynamics well enough for control purposes, model parameters are updated on-line with a Recursive Least Squares algorithm. Simulation results are successful and show the possibilities of the GPC control application to actual plants with varying or unknown dead-time.

  • PDF

Development of a System Analysis Code, SSC-K, for Inherent Safety Evaluation of The Korea Advanced Liquid Metal Reactor

  • Kwon, Young-Min;Lee, Yong-Bum;Chang, Won-Pyo;Dohee Hahn;Kim, Kyung-Doo
    • Nuclear Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.209-224
    • /
    • 2001
  • The SSC-K system analysis code is under development at the Korea Atomic Energy Research Institute (KAERI) as a part of the KALIMER project. The SSC-K code is being used as the principal tool for analyzing a variety of off-normal conditions or accidents of the preliminary KALIMER design. The SSC-K code features a multiple-channel core representation coupled with a point kinetics model with reactivity feedback. It provides a detailed, one-dimensional thermal-hydraulic simulation of the primary and secondary sodium coolant circuits, as well as the balance-of-plant steam/water circuit. Recently a two-dimensional hot pool model was incorporated into SSC-K for analysis of thermal stratification phenomena in the hot pool. In addition, SSC-K contains detailed models for the passive decay heat removal system and a generalized plant control system. The SSC-K code has also been applied to the computational engine for an interactive simulation of the KALIMER plant. This paper presents an overview of the recent activities concerned with SSC-K code model development This paper focuses on both descriptions of the newly adopted thermal hydraulic and neutronic models, and applications to KALIMER analyses for typical anticipated transients without scram.

  • PDF

Numerical study of particle dispersion from a power plant chimney (발전소 굴뚝에서의 입자 분산에 대한 수치해석)

  • Shim, Jeongbo;You, Donghyun
    • Particle and aerosol research
    • /
    • v.13 no.4
    • /
    • pp.173-182
    • /
    • 2017
  • An Eulerian-Lagrangin approach is used to compute particle dispersion from a power plant chimney. For air flow, three-dimensional incompressible filtered Navier-Stokes equations are solved with a subgrid-scale model by integrating the Newton's equation, while the dispersed phase is solved in a Lagrangian framework. The velocity ratios between crossflow and a jet of 0.455 and 0.727 are considered. Flow fields and particle distribution of both cases are evaluated and compared. When the velocity ratio is 0.455, it demonstrates a Kelvin-Helmholtz vortex structure above the chimney caused by the interaction between crossflow and a jet, whereas the other case shows flow structures at the top of the chimney collapsed by fast crossflow. Also, complex wake structures cause different particle distributions behind the chimney. The case with the velocity ratio of 0.727 demonstrates strong particle concentration at the vortical region, whereas the case with the velocity ratio of 0.455 shows more dispersive particle distribution. The simulation result shows similar tendency to the experimental result.

Assessment of Removal of Silver Nanoparticle in Sewage Treatment Plant Waste Using Process Simulation (공정 모사를 통한 하수처리장 내 은나노물질 제거 평가)

  • Oh, Seung Yeon;Kim, Younghun
    • Clean Technology
    • /
    • v.20 no.2
    • /
    • pp.160-165
    • /
    • 2014
  • Over the past decade, an increasing number of manufactured nanoparticles (NPs) have been incorporated into products and manufacturing processes due to the rapid innovation and commercialization in the field of nanotechnology. In addition, these nanomaterials and nano-consumer products have increased in quantity per year, and thus their uncontrolled release into the environment is anticipated to grow dramatically in future. However, A current sewage/wastewater treatment plant (SWTP) is being applied to removal of nanoparticles in wastewater. In Korea, the study on the removal of nanoparticles in SWTP was not reported yet. Therefore, in this work, to design pilot STP before field test, two model equations and commercial process simulation were used to derive the desing parameters.

The level control of Steam Generator in Nuclear Power Plant by Neural Network-PI Controller (PI-신경망 제어기를 이용한 원자력 발전소용 증기 발생기 수위제어)

  • 김동화
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.6-13
    • /
    • 1998
  • It is difficult to control for the level of the steam generator in the nuclear power plant because there is swell and shrink, and many disturbance such as, feed water rate, feedwater temperature, main steam flow rte, coolant temperature effect steam generator level. If the conventional PI controller use in this system, we cannot have a stability in the control of the lower power, the rejection function of disturbance, and the load following effectively. In this paper, e study the application of the of neural network based Kp, Ti for Pi controller to the level control of the steam generator of nuclear power plant through the simulation and experimental on the steam generator. We are satisfied with the resulting against the inturrupt of the disturbance, the change of setpoint through the simulation and the swell and shrink, the response of controller on the experimental steam generator.

  • PDF

Experimental study on the effect of EC-TMD on the vibration control of plant structure of PSPPs

  • Zhong, Tengfei;Feng, Xin;Zhang, Yu;Zhou, Jing
    • Smart Structures and Systems
    • /
    • v.29 no.3
    • /
    • pp.457-473
    • /
    • 2022
  • A high-frequency vibration control method is proposed in this paper for Pumped Storage Power Plants (PSPPs) using Eddy Current Tuned Mass Damper (EC-TMD), based on which a new type of EC-TMD device is designed. The eddy current damper parameters are optimized by numerical simulation. On this basis, physical simulation model tests are conducted to compare and study the effect of structural performance with and without damping, different control strategies, and different arrangement positions of TMD. The test results show that EC-TMD can effectively reduce the control effect under high-frequency vibration of the plant structure, and after the additional damping device forms EC-TMD, the energy dissipation is further realized due to the intervention of eddy current damping, and the control effect is subsequently improved. The Multi-Tuned Mass Damper (MTMD) control strategy broadens the tuning band to improve the robustness of the system, and the vibration advantage is more obvious. Also, some suggestions are made for the placement of the dampers to promote their application.

Impact Analysis of Construction of Small Wastewater Treatment Plant Under Climate Change (기후변화를 고려한 소규모 하수처리장 건설에 대한 영향 분석)

  • Park, Kyungshin;Chung, Eun-Sung;Kim, Sang-Ug;Lee, Kil Seong
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.2
    • /
    • pp.268-278
    • /
    • 2010
  • This study derived the effectiveness analysis results of construction of wastewater treatment plant under climate change scenarios. Canadian Global Coupled Model (CGCM3) was used and A1B and A2 of Special Report on Emission Scenario (SRES) were selected. Regional climate change data for this application were downscaled by using Statistical Downscaling Model (SDSM) and the flow and BOD concentration durations were obtained by using Hydrological Simulation Program - Fortran (HSPF). The criteria for low flow and water quality were chosen as $Q_{99}$, $Q_{95}$, $Q_{90}$ and $C_{30}$, $C_{10}$, $C_1$. The numbers of days to satisfy the instreamflow requirements and target BOD concentration were also added to the criteria for comparison. As a results, small wastewater treatment plant improved the water cycle due to the increase of low flow and the decrease of BOD concentration. But climate change affected the reduction of effectiveness significantly. Especially in case of construction of small waste water treatment plant in the upstream region, it is necessary to take climate change impact into consideration since it is usually related to the low flow and the water quality of the stream.

A Study on the Availability Modelling and Assessment with Failure Density Function of Major Equipment for a Sewage Treatment Plant (하수처리장 주요 기자재의 고장확률밀도함수를 이용한 가용도 모델링 및 평가에 관한 연구)

  • Lee, Hong-Cheol;Kwak, Pilljae;Lee, Hyundong;Hwang, In-Ju
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.11
    • /
    • pp.763-768
    • /
    • 2013
  • The simulation investigation on the availability with failure density function of major equipment for a sewage treatment plant has been carried out. This study focuses on the availability of the plant and criticality with equipment module induced by component layout and its failure function. The equipment classification of sewage treatment plant and its failure function are established. Also solution methodologies are introduced as Monte-Carlo simulation method and event algorithm for uncertainty problem. The availability in the case of serial connection of equipment with all exponential function is calculated as around 50.4%. In other case of parallel combination with back up equipment, the availability showed over 80.1%. The criticality that a ffects availability showed high value over 77% in the dehydration and concentration process of sludge.

A Note on Relay Feedback Identification Under Static Load Disturbances

  • Kaya, Ibrahim
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.395-400
    • /
    • 2015
  • Obtaining the parameters for PID controllers based on limit cycle information for the process in a relay controlled feedback loop has become an accepted practical procedure. If the form of the plant transfer function is known, exact expressions for the limit cycle frequency and amplitude can be derived so that their measurements, assumed error free, can be used to calculate the true parameter value. In the literature, parameter estimation for an assumed form of the plant transfer function has generally been considered for disturbance free cases, except a recently published work of the author. In this paper additional simulation results are reported on exact parameter estimation from relay autotuning under static load disturbances.

Analysis of Risk Assessment Factors for Gas leakage and Dispersion in Underground Power Plant (지하복합발전플랜트 내의 가스 누출 및 확산에 의한 위험성 평가 인자 분석)

  • Choi, Jinwook;Li, Longnan;Park, Jaeyong;Sung, Kunhyuk;Lee, Seonghyuk;Kim, Daejoong
    • Journal of ILASS-Korea
    • /
    • v.20 no.2
    • /
    • pp.101-106
    • /
    • 2015
  • Gas leakage and dispersion in the underground LNG power plant can lead to serious fire and explosion accident. In this study, computational fluid dynamics simulation was applied to model the dynamic process of gas leakage and dispersion phenomena in a closed space. To analyze the risk assessment factor, such as the flammable volume ratio, transient simulations were carried out for different scenarios. The simulation results visualized the gas distribution with time in the closed space. The flammable volume ratio was introduced for quantitative analysis the fire/explosion probability.