• Title/Summary/Keyword: Plant Evaluation

Search Result 2,907, Processing Time 0.046 seconds

Review and Application of the Radioactive Waste Certification Program (방사성폐기물 인증프로그램의 검토 및 적용)

  • Chung Hee-Jun;Whang Joo-Ho;Lee Jae-Min;Kim Heon;Jeong Yi-Yeong
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11a
    • /
    • pp.126-133
    • /
    • 2005
  • Securing of radioactive waste disposal site and the related operations for disposal of low and intermediate level radioactive waste is being actively carried out in Korea. For disposal of radioactive wastes, physicochemical and radiological status and integrity of radioactive wastes must be secured first. Also, waste generators must provide this information to disposers. In addition, to secure the safety of waste disposal, waste acceptance criteria (WAC) and site specific waste acceptance criteria (SWAC) to consider characteristics of the disposal site are required. Radioactive wastes must be processed, generated, managed and transferred in accordance with these criteria. [1] For this, evaluation of properties on each of the radioactive wastes must be performed. However, in reality, atomic power plants are experiencing difficulties in relation to this due to the large quantity of radioactive waste generation. In order to solve this problem, IAEA and major overseas countries have developed, thus are using waste certification program (WCP) and quality assurance program (QAP) [2,3]. On the basis of these programs, radioactive waste certification program has been developed for safe disposal of radioactive wastes in Korea to satisfy the provisions specified in 'low and intermediate level radioactive waste transfer guidelines' of announcement No. 2005-18 from the Ministry of Science and Technology and specific site waste acceptance criteria (tentative plan). In addition, it is being planned to administer amendment on commercial atomic power plant related procedures and ensile staff training in order for early introduction and operation of radioactive waste certification system.

  • PDF

Preliminary Shielding Analysis of the Concrete Cask for Spent Nuclear Fuel Under Dry Storage Conditions (건식저장조건의 사용후핵연료 콘크리트 저장용기 예비 방사선 차폐 평가)

  • Kim, Tae-Man;Dho, Ho-Seog;Cho, Chun-Hyung;Ko, Jae-Hun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.4
    • /
    • pp.391-402
    • /
    • 2017
  • The Korea Radioactive Waste Agency (KORAD) has developed a concrete cask for the dry storage of spent nuclear fuel that has been generated by domestic light-water reactors. During long-term storage of spent nuclear fuel in concrete casks kept in dry conditions, the integrity of the concrete cask and spent nuclear fuel must be maintained. In addition, the radiation dose rate must not exceed the storage facility's design standards. A suitable shielding design for radiation protection must be in place for the dry storage facilities of spent nuclear fuel under normal and accident conditions. Evaluation results show that the appropriate distance to the annual dose rate of 0.25 mSv for ordinary citizens is approximately 230 m. For a $2{\times}10$ arrangement within storage facilities, rollover accidents are assumed to have occurred while transferring one additional storage cask, with the bottom of the cask facing the controlled area boundary. The dose rates of 12.81 and 1.28 mSv were calculated at 100 m and 230 m from the outermost cask in the $2{\times}10$ arrangement. Therefore, a spent nuclear fuel concrete cask and storage facilities maintain radiological safety if the distance to the appropriately assessed controlled area boundary is ensured. In the future, the results of this study will be useful for the design and operation of nuclear power plant on-site storage or intermediate storage facilities based on the spent fuel management strategy.

Development of an Imaging-DOAS System for 2-D Remote Sensing of Atmospheric Gases (대기가스오염물질의 이차원 원격 모니터링을 위한 Imaging-DOAS 개발)

  • Lee, Han-Lim;Lee, Chul-Kyu;Jung, Jin-Sang;Park, Jeong-Eun;Kim, Young-Joon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.150-157
    • /
    • 2006
  • Spatially resolved remote identification and quantification of trace gases in the atmosphere is desirable in various fields of scientific research as well as in public security and industrial contexts. Environmental observations investigating causes, extent md consequences of air pollution are of fundamental interest. We present an Imaging-DOAS system, a ground based remote sensing instrument that allows spatially resolved mapping of atmospheric trace gases by a differential optical absorption spectroscopy(DOAS) with sun scattered light as the light source. A passive DOAS technique permits the identification and quantification of various gases, e.g., $NO_2,\;SO_2,\;and\;CH_2O$, from their differential absorption structures with high sensitivity. The Imaging-DOAS system consists of a scanning mirror, a focusing lens, a spectrometer, a 2-D CCD, ad the integral control software. An imaging spectrometer simultaneously acquires spectral information on the incident light in one spatial dimension(column) and sequentially scans the next spatial dimension with a motorized scanning mirror. The structure of the signal acquisition system is described in detail and the evaluation method is also briefly discussed. Applications of imaging of the $NO_2$ contents in the exhaust plumes from a power plant are presented.

Dissipation Pattern of Fungicides Boscalid and Pyraclostrobin in Jujube (대추 중 살균제 boscalid와 pyraclostrobin의 잔류 소실 특성)

  • Jo, Hyeong-Wook;Sohn, Sang-Hyun;Kim, Kyoung-Jin;Hwang, Gi-Jun;Jo, Beom-Haeng;Gil, Seok-Ju;Kwon, Chan-Hyeok;Moon, Joon-Kwan
    • The Korean Journal of Pesticide Science
    • /
    • v.21 no.1
    • /
    • pp.17-25
    • /
    • 2017
  • Dissipation pattern and biological half-lives of fungicides boscalid and pyraclostrobin were calculated on jujube. The pesticides were sprayed on jujube in two different field at the standard rate, respectively. The raw agricultural commodities were harvested at 0 (2 hr), 1, 3, 5, 7, 10 and 14 days after treatment, and analyzed by HPLC/DAD. The method limit of quantification (MLOQ) was $0.02mg\;kg^{-1}$ for boscalid and pyraclostrobin. The recovery ranged 101.8~109.3% with below 5% of CV (Coefficient of variation) for boscalid and 104.2~115.4% with below 5% of CV for pyraclostrobin. An average initial deposit at field 1 and field 2 samples were observed 0.40 and $0.48mg\;kg^{-1}$ for boscalid and, 0.76 and $0.57mg\;kg^{-1}$ for pyraclostrobin, respectively. The biological half-lives of field 1 and field 2 were 11.0 and 13.2 day for boscalid, and 6.1 and 12.7 days for pyraclostrobin.

Temperature and length of cold storage affect the Quality Maintenance of fresh kiwifruit (Actinidia chinensis Planch) (저온저장 온도 및 저장기간이 키위 "골드"의 품질 유지에 미치는 효과)

  • Yang, Yong-Joon;Lim, Byung-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.256-261
    • /
    • 2017
  • The effects of temperature and length of cold storage on the quality maintenance of fresh "Gold" kiwifruit were investigated. Physio-chemical properties were analyzed in kiwifruit held at $2^{\circ}C$ and $6^{\circ}C$ temperatures compared to fruit at room temperature ($20{\sim}28^{\circ}C$) during 8 weeks of storage. Low temperatures ($2^{\circ}C$ and $6^{\circ}C$) significantly delayed softening and soluble solids content (SSC) accumulation compared to higher temperature ($20{\sim}28^{\circ}C$). Physico-chemical properties of fruits, including weight losses, firmness, SSC, titratable acidity (TA), SSC/TA ratio, and flesh color properties were monitored during storage. Fast firmness loss was detected in fruit stored at higher temperatures compared to low temperature ($2^{\circ}C$). Similar results were observed for acidity according to storage temperature and length of cold storage, whereas SSC increased to the limited values (%Brix) during storage. The soluble solids content (SSC) increased markedly during the first 60 days of storage and remained almost constant thereafter for all treatments. SSC accumulation rates decreased from 5 weeks after storage probably due to differences between initial and ripe kiwifruits, and SSC decreased with each passing week due to natural starch conversion over time. The SSC/acid ratio increased from 18 to 27 until 5 weeks after storage and then slowly declined in all kiwifruit stored at different low temperatures. Sensory evaluation results showed no differences in kiwifruit flesh color stored at two storage temperatures of $2^{\circ}C$ and $6^{\circ}C$.

Evaluation of Pepper Germplasm and Cultivar Introduction (고추 보존(保存) 유전자원(遺傳資源)의 특성평가(特性評價)와 품종도입(品種導入))

  • Lee, Woo Sung;Kim, Byung Soo;Kim, Sang Gee;Park, Kyu Hwan;Kwon, Young Seok
    • Current Research on Agriculture and Life Sciences
    • /
    • v.8
    • /
    • pp.35-44
    • /
    • 1990
  • Sixty two lines of pepper including Korean local cultivars and introductions were planted out to the experiment farm of Kyungpook National University for seed increase, and 16 plant and fruit characters including days to flower were recorded. In days to flower, KC85(Chilgok Dongmyung) and KC116(PI308791), KC154(Cherry Sweet), and KC185(Choseongochu) were the earliest with 83 days, and KC139(Serrano chili) and KC103(PI297488) were the latest with 126 days. In fruit detachment force, KC85(Chilgok dongmyung) was the tenderest with 0.45kg and KC162(PI22444) was the toughest with 3.34kg. In powdery mildew incidence, KC10(Pimiento), KC23(PI224423), KC51(PI257044), KC56(PI257053), KC126(PI358812), KC119(PI322719), KC143(Emerald Giant), KC148(VR-2), KC163(PI224445), KC163(Papari Mild) were the least diseased. Anthracnose was least on KC39(Serrano Chili). Collection and introduction of pepper germplasm was continued. Fourteen Korean local cultivars and 25 foreign cultivars including 2 wild species were additionally collected or introduced.

  • PDF

The Evaluation on the exiting greens of Hwasan Country Club by undisturbed Soil Core Analysis (토양 코아 분석을 통한 화산 골프장의 조성된 그린에 대한 평가)

  • 이상재;허근영;심경구
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.26 no.2
    • /
    • pp.54-61
    • /
    • 1998
  • The subsurface environment of the root zone area can set the stae for "do or die" of the turfgrass plant. The good condition of the greens is verified by their physical properties. Therefore, this study was carried to evaluate on the existing green of Hwasan C.C. by undisturbed soil Core Anaysis. We completed the ISTRC SYSTEM BenchMarking of the undisturbed core samples taken from Green #1, Green #5, Green #9-"Best" area, and Green #9-"Stressed" area for the Hwasan C.C.. It was also our understanding that the greens were in "good" to "very good" conditioni. THe exception might be Green #9-"Stress" area, which was the stressed area. The stressed area was confined to a ridge across Green #9. The organic content test results comfirmed the development of organic layering in depth 0-2.5cm. For the amount of compaction in the upper root zones and te development of the green's respective organic layers, the infiltration rates were high in Green #1, Green #5, and Green #9 "Stressed" area. The depicted aerificaton hole might be the probable cause of the relatively high infiltraton rate. Green #9-"Best" area had a tested infiltration rate of 18.75cm/hr. Either this area had not been aerified, or the undisturbed sample did not contain a aerification cavity. The water retention capacity of the undisturbed samples was good. When the greens were first constructed, the original root zone mix had been relatively low water retention properties. And the bulk density and the porosity of the undisturbed samples were good. In the result, all the greens were similar except for the infiltration. Thus, we supposed that Green #9-"Stressed" area might be ainly influenced by the amount of irrigation water and the configuration of the green's surface. There had been a reduction in the amount of irrigation water as the water retention capacity in the greens was promoted. Especially, it had gradually become more of a problem as the green had matured in Green #9-"Stressed" area. Because Green #9-"Stressed" area was a ridge area. The reduction in the amount of irrigation water might be the probable cause of the stress in Green #9-"Stressed" area. Our final observation related to the soil texture and the particle size distribution of the sand. Though and sand contant of all the tested greens were good, the gravel content of them exceeded ISTRC Guidelines. In particle size distribution of the sand, the very coarse and the coarse content of all the tested greens exceeded, but the rest was insufficient. The stability is a function of the material retained on the 0.25mm mesh screen. But, the content of all the tested greens was very insufficient. Though all the greens was serviceable, the coarse root zone sands, such as the sand in the tested greens, tended to be "unstable". Thus, we recommend using a topdressing/aerification sand which should be more in line with ISTRC/USGA Guidelines.;unstable". Thus, we recommend using a topdressing/aerification sand which should be more in line with ISTRC/USGA Guidelines.ines.

  • PDF

Mixing Zone Analysis on Outfall Plume considering Influence of Temperature Variation (수온 변화의 영향을 고려한 방류관 플룸의 혼합역 분석)

  • Kim Ji-Yeon;Lee Joong-Woo
    • Journal of Navigation and Port Research
    • /
    • v.28 no.10 s.96
    • /
    • pp.947-953
    • /
    • 2004
  • As a large scale port development in coastal waters proceeds step by step and populations in the vicinity of port are getting increased, the issue on 'how to dispose the treated municipal water and wastewater in harbor' brings peoples' concern. The submarine outfall system discharges the primary or secondary treated effluent at the coastline or in deep water, or between these two. The effluent, which has a density similar to that of fresh water, rises to the sea surface forming plume or jet, together with entraining the surrounding sea water and becomes very dilute. We intended in this paper to investigate the impact on dilution of effluent and the behavior of flume under the conditions of the seasonal and spatial temperature variations, which have not been noticeable in designing effective marine outfall system. To predict and analyze the behaviour and dilution characteristics of plume not just with the effluent temperature, but also with the seasonal variation of temperature of surround water, CORMIX( Cornell Mixing Zone Expert System)-GI have been applied. The results should be used with caution in evaluation the mixing zone characteristics of discharged water. We hope to help for the effective operation of outfall system, probable outfall design, protection of water quality, and warm water discharges from a power plant, etc.

Evaluation of Filter-Adsorber(F/A) Process for Removal of Disinfection By-products(DBPs) (소독부산물 제어를 위한 실공정 F/A 운영에 관한 고찰)

  • Kim, Seong-Su;Lee, Kyung-Hyuk;Lim, Jae-Lim;Chae, Seon-Ha;Kang, Byeong-Soo;Moon, Pil-Joong;Ahn, Hyo-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1035-1042
    • /
    • 2005
  • Granular Activated Carbon(GAC) is widely used in drinking water treatment. At S and B Water Treatment Plant, GAC is used in place of granular media in conventional rapid filters(GAC Filter-Adsorber) for removal of Disinfection By-products(DBPs). The primary focus of this study is on the performance of existing filter-adsorber, and their operation. It was found that F/A process removed turbidity as effective as sand system. The ratio of Hydrophobic DOM (HPO) and hydrophilic DOM (HPI) fraction in the raw water at S and B WTP was similar. Filter Adsorber presented earlier DOC breakthrough and steady state condition which was contributed by biodegradation during operation period. The removal efficiency of DBPs were used to evaluate the filter performance. The DBPs concentration of F/A treated water was below treatment goal level (THM < $80\;{\mu}g/L$, HAA < $60{\mu}g/L$). The removal efficiency of THM decreased rapidly during operation period. However, HAA were removed steadily regardless of the influent concentration of HAA. These results indicate that the removal of THM depend upon the adsorption mechanism while the removal of HAA depend upon biodegradation as well as adsorption. The decrease of adsorption capacity and characteristic value of GAC may be attributed to the effect of high organic loading, residual free chlorine, coagulants, manganese oxidants and frequently backwashing. This study has confirmed that Filter adsorber process can be considered as effective alternatives for the removal of DBPs, especially HAA.

Evaluation of Ozone Application for Drinking Water Treatment Process Using DAF (DAF를 이용한 정수처리 공정에서의 오존 적용성 평가)

  • Kang, Tae-Hee;Oh, Byung-Soo;Cheong, Youn-Cheong;Kwon, Soon-Buhm;Sohn, Byeong-Yong;Kang, Joon-Wun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.567-572
    • /
    • 2005
  • In this study, a lab-scale test was performed to apply the ozone process in drinking water treatment plant using dissolved ai, flotation(DAF). The kinetic study on the ozone decay and hydroxyl(OH) radical formation was investigated by several parameters, such as I.D(Instantaneous ozone demand), $k_c$(ozone decomposition rate), ozone-Ct and OH radical-Ct. Ozonation of several target waters, such as raw water, DAF treated water and filtrate, was conducted to select the optimum position and dosage of ozone process. The highest value of Ozone-Ct and OH radical-Ct was observed at DAF treated water at initial run time($0{\sim}30\;min$). From the results of ozonation, the intermediate ozonation was proposed as the optimum position and the effective dose of ozone was determined to be $1{\sim}2\;mg/L$.