A Design of An Active PID control using Immune Algorithm for Vibration Control of Building Structure (구조물 진동제어를 위한 Immune Algorithm을 이용한 Active PID 제어기 설계)

  • Lee, Young-Jin;Cho, Hyun-Cheol;Lee, Kwon-Soon
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.72-74
    • /
    • 2005
  • In this paper, we propose an adaptive PID controller using a cell-mediated immune response to improve a PID control performance. The proposed controller is based on the specific immune response of the biological immune system that is cell-mediated immunity. The immune system of organisms in the real body regulates the antibody and the T-cells to protect an attack from the foreign materials like virus, germ cells, and other antigens. It has similar characteristics that are the adaptation and robustness to overcome disturbances and to control the plant of engineering application. We first build a model of the T-cell regulated immune response mechanism and then designed an I-PID controller focusing on the T-cell regulated immune response of the biological immune system. We apply the proposed methodology to building structures to mitigate vibrations due to strong winds for evaluation of control performances. Through computer simulations, system responses are illustrated and additionally compared to traditional control approaches.

  • PDF

Performance Simulation of Ground-Coupled Heat Pump(GCHP) System for a Detached House (단독주택 적용 지열 히트펌프 시스템의 성능 분석)

  • Sohn, Byong-Hu;Choi, Jong-Min;Choi, Hang-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.392-399
    • /
    • 2011
  • Ground-coupled heat pump(GCHP) systems have been shown to be an environmentally-friendly, efficient alternative to traditional cooling and heating systems in both residential and commercial applications. Although some work related to performance evaluation of GCHP systems for commercial buildings has been done, relatively little has been reported on the residential applications. The aim of this study is to evaluate the cooling and heating performances of a vertical GCHP system applied to an artificial detached house($117\;m^2$) in Seoul. For this purpose, a typical design procedure was involved with a combination of design parameters such as building loads, heat pump capacity, borehole diameter, and ground thermal properties, etc. The cooling and heating performance simulation of the system was conducted with different prediction times of 8760 hours and 240 months. The performance characteristics including seasonal system COP, average annual power consumption, and temperature variations related to ground heat exchanger were calculated and compared.

Evaluation of Pollutants Removal for Treated Wastewater Effluent and River Water by Meandering Constructed Wetland System (하수처리수와 하천수를 대상으로 한 생태적 수질정화 비오톱 시스템의 오염물질 제거에 대한 수질정화 평가)

  • Lee, Sang-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.131-139
    • /
    • 2012
  • Field experiment was performed from June 2010 to July 2011 to evaluate pollutants removal efficiency in the constructed wetland system for the treated wastewater and the river water. The wetland systems were constructed near Gyungan river. Two different systems with meandering shape were compared for seasonal base and operational period base. Several kinds of aquaculture are planted through the corridor of wetland system. Average removal rate of BOD, T-N and T-P for A system were 15.8%, 14.8% and 26.5%, respectively. Average removal rate of BOD, T-N and T-P for C system were 23.5%, 27.8% and 10.6%, respectively. The effluent from two wetland systems often exceeded effluent water quality standards for wastewater influent, however effluent water quality standards for river water. However, the wetland system can be useful to treat polluted river water and effluent from wastewater plant. Removal rate of pollutants in seasonal variation was the highest in summer for BOD and T-N, however the removal rates of T-P were higher in spring and autumn than in summer.

The usability evaluation of domestic urban sewage sludge as feedstock for biodiesel production( I ) - Comparison of the yields and composition of fatty acid methyl esters - (바이오디젤 생산을 위한 원료로서 국내 도시 하수슬러지의 활용성 평가( I ) - 지방산메틸에스테르(FAMEs)의 수율 및 조성 비교 -)

  • Kim, Nack-Joo;Jung, You-Won;Lee, Ik-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.115-121
    • /
    • 2012
  • This study was performed to assess the possibility of application of sewage sludge which is the side-product from domestic sewage treatment plant to the materials for biodiesels by investigating the yields and composition of the lipids and fatty acid methyl esters(FAMEs) from soxhlet extraction and in-situ transesterification. As the results, yields of in-situ transesterification were higher than soxhlet extraction. In comparison by sewage sludge type, yields of sewage sludge mixed nightsoil or livestock were higher than a single sewage sludge. And maximum yield showed up to 14 wt%. Fatty acid composition of extracted lipids and synthesized FAMEs consists of palmitic acid(C16:0), palmitoleic acid(C16:1), stearic acid(C18:0), oleic acid(C18:1), and linoleic acid(C18:2).

Evaluation of Hydraulic Behavior within Parallel arranged Upflow Sedimentation Basin Using CFD Simulation (I) - The influence of feed water inequity- (CFD를 이용한 병열 배열형 상향류식 침전지 수리해석에 관한 연구(I) - 침전지 내 유입유량 불균등 영향 조사 -)

  • Park, No-Suk;Kim, Seong-Su;Choi, Jong-Woong;Sung, Youl-Boong;Kang, Moon-Sun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.4
    • /
    • pp.469-477
    • /
    • 2013
  • In order to investigate the influence of feed water inequity on the settling performance for parallel arranged upflow sedimentation basin in domestic G_WTP(Water Treatment Plant), CFD(Computational Fluid Dynamics) simulation were employed and ADV(Acoustic Doppler Velocimeter) measurements were carried out. From the results of both CFD simulations and ADV measurements, the differences among inlet flow rates to each inlet structure make turbulent energy dissipation uneven overall sedimentation basin. Especially local velocities in the near of both side wall were observed over the design overflow rate(74.4 mm/min). Also, it was confirmed that this inequity of inlet flow would exert an serious influence on the turbidity of settled water which is out from 8 troughs. Even though experimental velocities in full scale basin about 20% higher than the simulated, the results of ADV measurement were in good accordance with those of CFD simulations.

Basic Survey for Evaluation of Instream flow at Natural Recovery Reach (자연형 하천 복원구간의 하천유지유량 산정을 위한 기초조사)

  • Sea, Kyu-Woo;Woo, Sang-Hwan;Kim, Gwang-Seob
    • Journal of Wetlands Research
    • /
    • v.3 no.2
    • /
    • pp.119-131
    • /
    • 2001
  • This study uses HEC-RAS for the quantitative aspects and the QUAL2E model for the qualitative aspects of the flow of urban streams, where the natural recovery system is applied. The instream flow of the small streams is estimated using the numerical model by verifying the existing data with the acquired data. The characteristics of the model reach place more weight on the drought discharge around the ordinary discharge, and this is caused by the natural recovery system that maintains the existing bank. The data of direct discharge to the sewage treatment plant through the inception pipe, BOD, DO, temperature, and so forth, are the official data from the department of environment. Considering the characteristics of small streams, the factors for the QUAL2E model are estimated with the focus on the hydraulic conditions and the stream view. This study proposes the future improvements for the natural recovery system by investigating the practical use of the waterfront and the application of the proper instream flow. Also, the hydraulic and hydrological investigation of the covering rate by the natural vegetation and the meandering by the varying river way is performed.

  • PDF

Focal Depth Factors in the PSH Analysis

  • Kim, Jun-Kyoung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.3
    • /
    • pp.83-86
    • /
    • 1998
  • The results from the Individual Plant Examination of External Event of Yonggwyang nuclear power plants, unit 3 & 4, in Korea have shown that the high degree of diversities of the experts' opinions on seismicity and attenuation models is su, pp.sed to be generic cause of uncertainty of APEs(annual exceedance probability) in the PAHA(probabilistic seismic hazard analysis). This study investigated the sensitivity of the focal depth, which is one of the most uncertain seismicity parameters in Korea, Significant differences in resultant values of annual exceedance probabilities and much more symmetrical shape of the resultant PDFs(probability density functions), in case of consideration of focal depth, are found. These two results suggest that, even for the same seismic input data set including the seismicity models and ground motion attenuation models, to consider focal depth additionally for probabilistic seismic hazard analysis evaluation makes significant influence on the distributions of uncertainties and probabilities of exceedance per year for the whole ranges of seismic hazard levels. These facts suggest that it is necessary to derive focal depth parameter more effectively from the historical and instrumental documents on earthquake phenomena in Koran Peninsula for the future study of PSHA.

  • PDF

High-Temperature Stability Evaluation of Various Surface Treated Layers of Materials for Ultra-Super Critical Power Plants (초초임계압 발전용 소재의 표면처리층의 고온 안정성 평가)

  • Ryu, K.H.;Song, T.K.;Lee, J.H.;Kim, G.S.;Lee, S.H.;Urm, K.W.
    • Korean Journal of Materials Research
    • /
    • v.16 no.5
    • /
    • pp.329-335
    • /
    • 2006
  • In order to improve thermal efficiency of the fossil fuel power plants, we need to develop advanced materials with superior durability in the ultra-super critical state, which requires surface modifications for superior surface properties. In this study, we coated the Incoloy 901 and 12-17Cr steels for turbine buckets and valves with nitriding, boriding, and $Cr_3C_2-NiCr$ HVOF(high velocity oxygen flow) method. Then the samples were heat treated at $650^{\circ}C$ for 100 hours in vacuum. We analyzed the evolution behaviors of nitrides such as $Fe_3N,\;Fe_4N$, and CrN and borides such as FeB and $Fe_2B$ with XRD and SEM/EDS by comparing hardnesses and compositions of the coated layers before and after the heat treatments.

A Study on the Improvement of Subsidy Program for CHP Plant Connected with Capital Region District Heating System (수도권 지역난방연계 열병합발전소의 기반기금 지원과 개선방안)

  • 김창수;이창호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.2
    • /
    • pp.97-103
    • /
    • 2004
  • CHP system supplies electricity and heating together with high efficiency. Current utility's CHP system uses electric power by itself and sells thermal energy to KDHC(Korea District Heating Corporation). CHP's operation cost except sales revenue of heating was covered by the sale revenue of electricity. Thus Electric generation cost in district Heating CHP system has close relationship with the level of heating price. However, after the restructuring of electricity industry, the operation cost could not be covered by sales revenue of heating and electricity. This loss was compensated by energy subsidy program in the electric power industry infrastructure fund. This paper suggests reasonable evaluation and improvement methods of the loss calculation of CHP system utilizing the infrastructure fund efficiency In terms of the direction of support by the fund, it provides the methods to prevent inefficient operation through setting up the upper limit of subsidy and to improve the loss calculation. Moreover, it suggest fixed rate support by heating supply level and reducing subsidy gradually for an efficient operation of CHP system.

Human Factors Evaluations of Alarm Displays in Main Control Rooms

  • Choe, Pilsung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.69-75
    • /
    • 2013
  • Objective: This study proposes an alarm display and compares it with the one(alarm tile display) widely used in main control rooms(MCRs) of nuclear power plants. Background: Catching up with the rapid development of computer technologies, advanced MCRs has been required. Using modern technologies of computers and visual displays, we have a lot of potential to improve user performance and satisfaction as well as safety in MCRs. Method: The alarm bar display has been proposed to reduce some potential problems of the alarm tile display in this study. Human factors evaluations were conducted to compare both types of displays. Two interfaces of bar alarm and tile alarm were simulated on the desktop computer for the user-involved experiment. Eight students participated in the experiment with the within-subject design. Results: The alarm bar was slightly better in terms of situation awareness, and preferred to understand alarm dynamics. The alarm tile was slightly or significantly better in other measures. Conclusion: Both alarm displays have their own advantages and disadvantages. Therefore, combining benefits of both displays can be used to optimize the design of alarm displays. Application: The proposed display is expected to compensate the existing displays for certain purposes.