• Title/Summary/Keyword: Plant Capacity

Search Result 1,534, Processing Time 0.036 seconds

LAND FARMING OF WATER PLANT ALUM SLUDGE ON ACID MINERAL SOIL AFFECTED BY ACID WATER

  • Lee, Seung-Sin;Kim, Jae-Gon;Moon, Hi-Soo;Kang, Il-Mo
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.182-186
    • /
    • 2001
  • An acid forest surface soil as a land farming medium was treated with a water plant alum sludge at 0 to 18%. Indian mustard was grown in the treated soil in a greenhouse for 5 weeks and watered with pH 4 tap water adjusted with a mixed acid (1HNO$_3$: 2H$_2$SO$_4$) during plant growth. Changes in soil property, leachate chemistry, plant growth, and plant uptake of elements by the sludge treatment were determined. The alum sludge treatment increased buffer capacity to acidity, hydraulic conductivity, water holding capacity, and phosphate adsorption of the soil and decreased bulk density and mobility of small particles. The sludge treatment reduced leaching of Al, Mg, K, Na, and root elongation. Plant did uptake less amount of the cations and P but more Ca with the sludge treatment.

  • PDF

A study on the efficiency of ESS installed in a small solar power plant based on actual data (실측데이터 기반 소규모 태양광발전소 연계용 ESS 효율 분석에 관한 연구)

  • Youn, Geum-Ran;Lee, Tae-kyu;Kim, Jeong-Uk
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.350-357
    • /
    • 2019
  • We analyzed the system efficiency of small solar power plants with 80% of total solar power plants. The data of the solar power plant with installed capacity of 100kW was collected and the correlation of the ESS efficiency according to the capacity of the PCS and the battery of each power plant was deduced. As a result, the higher the C-rate value affecting the discharge rate of the battery, The discharge efficiency of the plasma display panel is increased.

Prediction of Maximum Fly Ash Conveying Capacity of Fly Ash System in a Power Plant (발전 보일러용 비회 이송설비에서 최대 비회 이송량 예측)

  • Jin, Kyung-Yong;Moon, Yoon-Jae;Lee, Jae-Heon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.11 no.1
    • /
    • pp.50-57
    • /
    • 2015
  • This study presents prediction of maximum fly ash conveying capacity of fly ash system in a power plant. The mixture ratio and pressure drop characteristics of air-fly ash flow in piping system are not well understood due to the complexity of particle motion mechanism. In this paper, the researcher investigated the optimum mixture ratio when the pressure drop of fly ash conveying system is equal to maximum static pressure of displacement fly ash transport blower and the capacity of fly ash transport according to the optimum mixture ratio by experimenting the fly ash conveying system of domestic D coal thermal power plants, which is currently in operation. The experiment results showed that the maximum fly ash conveying capacity of fly ash system were founded under the condition of maximum air volume 5,040 m3/h, static pressure of trip condition 1,163 mmH2O. In addition, it was predicted maximum mixture ratio of the air-fly ash was 8.66 and maximum capacity of fly ash conveying was 52,600 kg/h under these conditions.

  • PDF

SIMULATION AND AUTOMATION OF A RICE MILL PLANT - DEVELOPMENT OF SIMULATION MODEL -

  • Chung, J.H.;Youm, G.O.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.378-387
    • /
    • 2000
  • A rice mill plant with a capacity of 2.5 ton/hr was constructed with automated facilities at Chonnam National University. A simulation model was developed with SLAM SYSTEM for evaluating and improving the rice mill plant. The developed model was validated in the views of hulling efficiency, milling efficiency, milled rice recovery, other materials produced, and bottlenecks in the processes. The results of hulling efficiency, milling efficiency, milled rice recovery in the simulation were, respectively, 81.1%, 89.5%, and 73.1%, while those of the actual mill plant were 81.5%, 90.2%, and 73.5%. The simulation results including the productivity of other materials(chaff, bran, broken rice, stone, etc) produced in the processes were almost similar with those of the actual process. In the simulation the bottlenecks were found out in the processes of separating brown rice and of sorting colored rice. These phenomenon also appeared in the actual process. It needed to increase the hourly capacity of the brown rice separator and the rice color sorter. As the developed model could well express the automated rice mill plant, it could be used for designing and improving rice mill plants. In addition, an alternative model needed to be developed for the system control more accurately and for increasing the rice quality.

  • PDF

A study on the application of the extreme value distribution model for analysis of probability of exceeding the facility capacity (시설용량을 초과하는 폐수량의 유입확률 분석을 위한 극치분포모델의 적용에 관한 연구)

  • Choi, Sunghyun;Yoo, Soonyoo;Park, Taeuk;Park, Kyoohong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.4
    • /
    • pp.369-379
    • /
    • 2016
  • It was confirmed that the extreme value distribution model applies to probability of exceeding more than once a day monthly the facility capacities using data of daily maximum inflow rate for 7 wastewater treatment plant. The result of applying the extreme value model, A, D, E wastewater treatment plant has a problem compared to B, C, F, G wastewater treatment plant. but all the wastewater treatment plant has a problem except C, F wastewater treatment plant based 80% of facility capacity. In conclusion, if you make a standard in statistical aspects probability exceeding more than once a day monthly can be 'exceed day is less than a few times annually' or 'probability of exceeding more than once a day monthly is less than what percent'.

A techno-economic analysis of partial repowering of a 210 MW coal fired power plant

  • Samanta, Samiran;Ghosh, Sudip
    • Advances in Energy Research
    • /
    • v.3 no.3
    • /
    • pp.167-179
    • /
    • 2015
  • This paper presents a techno-economic analysis of a partial repowering scheme for an existing 210 MW coal fired power plant by integrating a gas turbine and by employing waste heat recovery. In this repowering scheme, one of the four operating coal mills is taken out and a new natural gas fired gas turbine (GT) block is considered to be integrated, whose exhaust is fed to the furnace of the existing boiler. Feedwater heating is proposed through the utilization of waste heat of the boiler exhaust gas. From the thermodynamic analysis it is seen that the proposed repowering scheme helps to increase the plant capacity by about 28% and the overall efficiency by 27%. It also results in 21% reduction in the plant heat rate and 29% reduction in the specific $CO_2$ emissions. The economic analysis reveals that the partial repowering scheme is cost effective resulting in a reduction of the unit cost of electricity (UCOE) by 8.4%. The economic analysis further shows that the UCOE of the repowered plant is lower than that of a new green-field power plant of similar capacity.

Comparative analysis of yeast cell viability at exponential and stationary growth phases

  • An, Yejin;Jo, Nayoon;Kim, Hyeji;Nam, Dahye;Son, Woorim;Park, Jinkyu
    • Analytical Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.181-188
    • /
    • 2022
  • This paper describes a comparative analysis of yeast cell viability at exponential and stationary growth phases using multiple conventional techniques and statistical tools. Overall, cellular responses to various viability assays were asynchronous. Results of optical density measurement and direct cell counting were asynchronous both at exponential and stationary phases. Proliferative capacity measurement using SP-SDS indicated that cells at the end of the stationary phase were proliferative as much as exponentially growing cells. Metabolic activity assays using two different dyes concluded that the inside of cells at stationary phase is slightly less reducing compared to that of exponentially growing cells, implying that the metabolic activity imperceptibly declined as cells were aged. These results will be helpful to understand the details of yeast cell viability at exponential and stationary growth phases.

The effects of plant extracts on lipid metabolism of chickens - A review

  • Xuedong Ding;Ilias Giannenas;Ioannis Skoufos;Jing Wang;Weiyun Zhu
    • Animal Bioscience
    • /
    • v.36 no.5
    • /
    • pp.679-691
    • /
    • 2023
  • The fat deposition is an important factor affecting chicken meat quality, which is closely related to lipid metabolism of chickens. Therefore, it is important to regulate the lipid metabolism of chickens to improve the chicken meat quality. Plant extracts have special regulatory effects on animal's growth and health and have been widely used in chicken breeding. Some plant extracts have been reported to have functions of changing the fatty acid composition, reducing abdominal fat percentage, and enhancing the intramuscular fat content of chickens by improving the antioxidant capacity, regulating the expression of genes, enzymes, and signaling pathways related to lipid metabolism, modulating intestinal microbiota, affecting hormones level, and regulating DNA methylation. This paper reviewed the application and mechanism of plant extracts on regulating lipid metabolism of chickens to provide a reference for the further application of plant extracts in chicken breeding.

Design and Performance Prediction of Small Hydropower Plant Using Treated Effluent in Wastewater Treatment Plant (하수처리수를 이용한 소수력발전소 설계 및 성능예측)

  • Lee, Chul-Hyung;Park, Wan-Soon;Kim, Won-Kyoung;Kim, Jeong-Yeon;Chae, Kyu-Jung
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.78-83
    • /
    • 2013
  • A methodology to predict the output performance of small hydro power plant using treated effluent in waste water treatment plant has been studied. Existing waste water treatment plant located in Kyunggi-Do were selected and the output performance characteristics for these plants were analyzed. .Based on the models developed in this study, the hydrologic performance characteristics for SHP sites have been analyzed. The results show that the flow duration characteristics of small hydropower plant for waste water treatment plant have quite differences compared with small hydropower plant for the river. As a result, it was found that the developed model in this study can be used to analyze the output characteristics for small hydro power in waste water treatment plant. Additionally, primary design specifications such as design flowrate, capacity, operational rate and annual electricity production were estimated and discussed. It was found that the models developed in this study can be used to decide the design performance of small hydropower plant for waste water treatment plant effectively.

Estimating generation capacity of geothermal power generation pilot plant project (우리나라 지열발전 pilot plant 프로젝트의 발전량 추정)

  • Song, Yoonho;Lee, Tae Jong;Yoon, Woon Sang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.197.1-197.1
    • /
    • 2011
  • Target generation capacity of geothermal power generation pilot plant project through the Enhanced Geothermal Systems (EGS) with a doublet system down to 5 km depth was estimated. Production and re-injection temperatures of geothermal fluid were assumed $160^{\circ}C$ and $60^{\circ}C$, respectively, based on reservoir temperature of $180^{\circ}C$ calculated from the geothermal gradient of $33^{\circ}C$ in Pohang area. In this temperature range, 0.11 of thermal efficiency of the binary generation cycle is a practical choice. Assuming flow rates of 40 kg/sec, which is possible in current EGS technology, gross power generation capacity is estimated to reach 1.848 MW. Net generation considering auxiliary power including pumping power for geothermal fluid and condensing (cooling) energy of working fluid can be 1.5 MW.

  • PDF