Chest-wall Surface Dose During Post-mastectomy Radiation Therapy, with and without Nonmagnetic Bolus: A Phantom Study

  • Choi, Cheon Woong;Hong, Joo Wan;Park, Cheol Soo;Ahn, Jae Ouk
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.293-297
    • /
    • 2016
  • For mastectomy patients, sufficient doses of radiation should be delivered to the surface of the chest wall to prevent recurrence. A bolus is used to increase the surface dose on the chest wall, whereby the surface dose is confirmed with the use of a virtual bolus during the computerized treatment-planning process. The purpose of this study is an examination of the difference between the dose of the computerized treatment plan and the dose that is measured on the bolus. Part of the left breast of an Anderson Rando phantom was removed, followed by the attainment of computed tomography (CT) images that were used as the basis for computerized treatment plans that were established with no bolus, a 3 mm-thick bolus, a 5 mm-thick bolus, and a 10 mm-thick bolus. For the computerized treatment plan, a prescribed dose regimen was dispensed daily and planning target volume (PTV) coverage was applied according to the RTOG 1304 guidelines. Using each of the established computerized treatment plans, chest-wall doses of 5 points were measured; this chest-wall dose was used as the standard for the analysis of this study, while the level of significance was set at P < 0.05. The measurement of the chest-wall dose with no bolus is 1.6 % to 10.3 % higher, and the differences of the minimum average and the maximum average of the five measurement points are -13.8 and -1.9, respectively (P < 0.05); however, when the bolus was used, the dosage was measured as 3.7 % to 9.2 % lower, and the differences of the minimum average and the maximum average are 7.4 and 9.0, -1.2 and 17.4, and 8.1 and 19.8 for 3 mm, 5 mm, and 10 mm, respectively (P < 0.05). As the thickness of the bolus is increased, the differences of the average surface dose are further increased. There are a variety of factors that affect the surface dose on the chest wall during post-mastectomy radiation therapy, for which verification is required; in particular, a consideration of the appropriate thickness and the number of uses when a bolus is used, and which has the greatest effect on the surface dose on the chest wall, is considered necessary.

아크치료기법과 토모테라피치료의 선량분포 비교 (Dose Distribution Comparison between Arc Radiation Therapy and Tomotherapy)

  • 김지윤;이승철;천금성;김영재
    • 한국방사선학회논문지
    • /
    • 제15권5호
    • /
    • pp.723-730
    • /
    • 2021
  • 방사선 치료 시 주로 쓰이는 Arc 치료기법과 Tomotherapy 치료법의 선량적인 측면에서 상호 비교하고자 한다. 대상자는 폐암의 환자를 대상으로 하여 치료계획용적에 60.0 Gy를 처방선량을 기준으로 설정하였다. PTVmean는 Arc의 경우 61.04 Gy, Tomotherapy가 58.50 Gy, 이었다. 전체 폐용적(total lung)은 각각 3.0 Gy, 4.24 Gy, 심장(heart)은 0.13, 0.34, 기도(trachea)는 1.35, 2.58, 식도(Esophagus)는 0.41, 0.86, 척수는 3.65, 4.68의 평균선량을 보였다. DHV 곡선상 치료효과의 적합성은 모두 적합해 보였으며 둘 중에는 Tomotherpy의 치료법이 정상조직 방호적인 측면에서 우세한 것으로 나타났다. 제한적인 공간에서 오랜시간 치료를 받아야 하는 점을 극복한다면 tomotherapy치료가 우세하지만 그렇지 않은 경우 Arc 치료로 진행해도 무방할 것으로 사료된다. 본 연구는 치료계획 영상으로 분석한 것으로 실제 치료의 결과와 다르다는 제한점이 있다. 이러한 제한점을 극복하고자 더 많은 연구를 진행한다면 방사선 치료의 효과는 더욱 상승할 것으로 사료된다.

좌측 유방암의 방사선치료 자세와 선량인자의 상관관계 분석 (Correlation analysis of radiation therapy position and dose factors for left breast cancer)

  • 전재완;박철우;홍종수;진성진;강정훈
    • 대한방사선치료학회지
    • /
    • 제29권1호
    • /
    • pp.37-48
    • /
    • 2017
  • 목 적: 방사선치료의 가장 기본적인 조건은 정상조직의 불필요한 피폭을 방지하는 것이다. 유방암의 경우는 폐와 심장에 조사되는 선량이 중요하게 평가되는 인자이다. 따라서 유방암 방사선치료 자세에 따른 정상조직에 조사되는 선량을 비교하고 그 연관성을 상관관계 분석을 통하여 결과를 확인하여 보다 효과적인 유방암 방사선 치료방법을 모색하고자 한다. 대상 및 방법: 본원을 내원한 좌측 유방암 환자 30명을 대상으로 Supine, Prone Position에서 CT image를 획득하였다. Eclipse Treatment Planning System(Version 11, USA)을 이용하여 전산화치료계획을 수립하였다. DVH(Dose Volume Histogram)을 통해 Position 별로 정상조직에 조사된 선량을 비교하였다. 그 결과를 바탕으로 SPSS(Version 18)을 이용하여 각 정상조직의 선량인자를 통계분석하고 항목 간 상관관계 분석 및 독립표본 t-test를 통하여 그 연관성을 알아보았다. 그리고 MIRADA RTx(Version Advanced 1.6, UK)를 이용하여 HI(Homogeneity Index)와 CI(Conformity Index)를 Supine, Prone Position에서 값을 구하고 비교하였다. 결 과: 유방암의 전산화치료계획의 결과 폐의 경우는 Supine Position에서 V20은 $16.5{\pm}2.6%$, V30은 $13.8{\pm}2.2%$, Mean dose는 $779.1{\pm}135.9cGy$(Absolute value)를 보였다. Prone Position은 위 순서대로 $3.1{\pm}2.2%$, $1.8{\pm}1.7%$, $241.4{\pm}138.3cGy$를 보였다. Prone Position이 전반적으로 낮은 선량을 나타내었고 평균선량 537.7 cGy가 더 적게 폐에 조사되었다. 심장의 경우에는 Supine, Prone 순서대로 V30은 $8.1{\pm}2.6%$, $5.1{\pm}2.5%$, Mean dose는 $594.9{\pm}225.3cGy$, $408{\pm}183.6cGy$를 보였다. Prone Position에서 평균선량 182.6 cGy가 더 적게 조사된다는 것을 확인하였다. 통계분석 결과 신뢰도 분석지표인 Cronbach's Alpha value는 0.563이였고 변수간의 상관관계분석 결과 치료자세와 폐의 선량평가인자는 대략 0.89 이상으로 그 상관관계가 높았다. 반면 심장의 경우는 V30은 0.488, Mean dose는 0.418로 상관관계가 다소 적었다. 마지막으로 독립표본 t-test 결과 치료자세와 폐, 심장의 선량평가인자가 신뢰수준 99 %에서 모두 유의하게 나타났다($p-value{\leq}0.05$). 결 론: 현재 방사선치료는 최첨단 선형가속기와 다양화된 전산화치료계획 기술이 개발되고 있다. 이 발전의 기본전제 조건은 PTV(Planning Target Volume) 주위의 정상조직 보호라고 생각한다. 물론 유방암 환자를 Prone Position에서 치료하면 Set-up의 재현성 문제와 다소 많은 시간이 소요되지만 이 실험결과에서 보듯이 Prone Position에서 폐와 심장에 들어가는 선량을 줄일 수 있으며 그 연관관계도 의미가 있다는 것을 확인하였다. 결론적으로 Prone Position에서 충분한 치료시간을 확보하고 정확한 치료부위 확인이 이루어진다면 환자에게 보다 좋은 방사선치료를 제공할 수 있다고 생각된다.

  • PDF

세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance) (Quality Assurance for Intensity Modulated Radiation Therapy)

  • 조병철;박석원;오도훈;배훈식
    • Radiation Oncology Journal
    • /
    • 제19권3호
    • /
    • pp.275-286
    • /
    • 2001
  • 목적 : 세기조절방사선치료의 임상적용을 위한 정도보증 절차를 확립하고, 실제 치료환자 1례에 대한 적용 과정을 보고하고자 한다. 대상 및 방법 : 본원에서는 세기조절방사선치료를 시행하기 위해 역방향 치료계획(inverse planning) 시스템으로 $P^3IMRT$ (ADAC, 미국)와 다엽콜리메이터(Multileaf collimator, MLC)가 부착된 방사선치료용 선형가속기 Primus (Siemens, 미국)를 사용하였다. 먼저 다엽콜리메이터에 대한 위치의 정확성, 재현성, leaf transmission factor를 측정하였다. 또한 소조사면에 대한 치료계획시스템의 commissioning을 실시하였다. 이를 이용하여 C자 형태의 가상 PTV (Planning Target Volume)에 대해 9개의 빔을 사용하여 세기변조 조사빔을 설계하여, 이를 팬톰 내에서 절대선량 및 상대선량을 측정하여 비교, 분석하였다. 실제 6개의 세기변조 조사빔을 사용하여 치료를 시행한 전립선암 환자를 대상으로, 팬톰내에서 재 계산된 선량계산 결과를 0.015 cc 미소전리함, 다이오드선량계(Scanditronix, 스웨덴), 필름 선량계, 그리고 선형배열다중검출기(array detector) 등을 사용하여 절대선량 및 상대선량을 평가하였다. 결과 : MLC 위치 정확도는 1 mm 이내이었으며, 재현성은 0.5 mm 내외로 평가되었고, leaf transmission 인자는 10MV 광자선에 대해서 interleaf leakage의 경우, $1.9\%$, midleaf leakage의 경우, $0.9\%$로 측정되었다. 필름, 다이오드선량계, 미소전리함, 물팬톰용 전리함(0.125 cc) 등의 반음영을 측정해 본 결과, 물팬톰용 전리함으로 측정된 반음영 영역$(80\~20\%)$은 필름에 비해 2 mm 가량 크며, 최소 beamlet 크기가 5 mm 임을 감안할 때 부적합한 것으로 판명되었다. RTP commissioning 후 계산 선량은 $1\times1\;cm^2$ 크기 소조사면에서의 측정치와 $2\%$ 범위 내에서 일치하였다. C자 형태의 PTV에 대한 9개의 세기변조된 조사빔에 대한 2회에 걸친 치료중심점에서의 절대선량 측정결과 개별 조사빔에 대하여는 $10\%$ 이상 차이를 보였으나 총 선량은 $2\%$ 이내에서 일치하였다. 필름을 이용한 선량분포도도 계산치와 비교적 잘 일치하였다. 실제 치료환자의 팬톰 내에서의 절대선량 측정 결과 총 선량은 $1.5\%$ 차이를 보였다. 각 조사빔에 대해 중심 leaf의 측방선량분포도를 필름 및 선형배열다중검출기를 사용하여 측정하였으며, 조사면 밖에서 계산선량이 $2\%$ 내외로 작게 나타났으나, 특정 위치를 제외하고는 $3\%$ 이내로 잘 일치함을 확인하였다. 결론 : 세기조절방사선치료를 위해서는 다엽콜리메이터의 위치에 대한 보다 정밀한 정도관리 절차가 개발되어야 될 것으로 판단되며, 조사빔내 세기패턴을 효율적으로 확인할 수 있는 정도보증 절차가 필요할 것으로 사료된다. 본원에서는 팬톰 내에서의 치료중심점과 같이 특정 지점에서의 절대선량 확인 및 필름 혹은 선형배열다중검출기를 사용한 세기분포 패턴의 확인 과정을 통하여, 이를 적절히 병행하여 사용함으로써 세기조절방사선치료에 적합한 정도관리를 시행할 수 있었다.

  • PDF

USEFULNESS OF SIMPLE SHIELDING TECHNIQUE USING MULTILEAF COLLIMATOR IN BREAST RADIATION THERAPY

  • Lee, Kyu Chan;Lee, Seok Ho;Lee, Seung Heon;Sung, Kihoon;Ahn, So Hyun;Choi, Jinho;Dong, Kap Sang;Kim, Hyo Jin;Chun, Yong Seon;Park, Heung Kyu
    • Journal of Radiation Protection and Research
    • /
    • 제39권4호
    • /
    • pp.168-175
    • /
    • 2014
  • This study was designed to assess whether the conventional tangential technique, using a multileaf collimator (MLC), allows a reduced dose to the organs at risk (OAR) in breast radiation therapy. A total of forty right and left 20 for each breast cancer patients that underwent radiation therapy after breast conserving surgery were included in this study. For each patient, the planning target volume (PTV) and OAR (heart, left anterior descending artery (LAD), liver and lung) were defined and dose distribution were produced for conventional tangential beams using 6 MV photons. The treatment plans were made using the following two techniques for all patients. For the first plan (P1), MLC was designed to shield as much of OAR as possible without compromising the coverage of PTV. In the second plan (P2), the treatment plan was created without using MLC. Dose-volume histograms for OARs were calculated for all plans. For left breast cancer, the percentage of maximum dose ($D_{max%}$) and mean dose ($D_{mean%}$) of OARs (heart and LAD) were calculated, and for right breast cancer, the percentage of the mean dose ($D_{mean%}$) of the liver was calculated. The $D_{mean%}$ of the lung was calculated in all patients. The mean values of $D_{max%}$ of the heart ($86.9{\pm}19.5%$ range, 35.1-100.6%) in P1 were significantly lower than in P2 ($98.3{\pm}3.4%$ range, 91.7-105.2%) (p=0.001). The mean values of $D_{max%}$ of LAD ($78.4{\pm}22.5%$ range, 26.5-99.7%) in P1 was significantly lower than in P2 ($93.3{\pm}8.1%$ range, 67.9-102.1%) (p<0.001). In P1, the mean values of $D_{mean%}$ of the liver ($4.8{\pm}2.0%$) were significantly lower than in P2 ($6.2{\pm}2.5%$) (p<0.001). The mean values of $D_{mean%}$ of the lung were significantly lower in P1 ($9.3{\pm}2.3%$) than in P2 ($9.7{\pm}2.4%$) (p<0.001). P1, by using MLC, allows a significantly reduced dose to OAR compared with P2. We can suggest that it is reasonable to routinely use MLC in the conventional tangential technique for breast radiation therapy considering the primary tumor location.

Fabrication of a Patient-Customized Helmet with a Three-Dimensional Printer for Radiation Therapy of Scalp

  • Oh, Se An;Lee, Chang Min;Lee, Min Woo;Lee, Yeong Seok;Lee, Gyu Hwan;Kim, Seong Hoon;Kim, Sung Kyu;Park, Jae Won;Yea, Ji Woon
    • 한국의학물리학회지:의학물리
    • /
    • 제28권3호
    • /
    • pp.100-105
    • /
    • 2017
  • The purpose of the present study was to develop and evaluate patient-customized helmets with a three-dimensional (3D) printer for radiation therapy of malignant scalp tumors. Computed tomography was performed in a case an Alderson RANDO phantom without bolus (Non_Bolus), in a case with a dental wax bolus on the scalp (Wax_Bolus), and in a case with a patient-customized helmet fabricated using a 3D printer (3D Printing_Bolus); treatment plans for each of the 3 cases were compared. When wax bolus was used to fabricate a bolus, a drier was used to apply heat to the bolus to make the helmet. $3-matic^{(R)}$ (Materialise) was used for modeling and polyamide 12 (PA-12) was used as a material, 3D Printing bolus was fabricated using a HP JET Fusion 3D 4200. The average Hounsfield Unit (HU) for the Wax_Bolus was -100, and that of the 3D Printing_Bolus was -10. The average radiation doses to the normal brain with the Non_Bolus, Wax_Bolus, and 3D Printing_Bolus methods were 36.3%, 40.2%, and 36.9%, and the minimum radiation dose were 0.9%, 1.6%, 1.4%, respectively. The organs at risk dose were not significantly difference. However, the 95% radiation doses into the planning target volume (PTV) were 61.85%, 94.53%, and 97.82%, and the minimum doses were 0%, 77.1%, and 82.8%, respectively. The technique used to fabricate patient-customized helmets with a 3D printer for radiation therapy of malignant scalp tumors is highly useful, and is expected to accurately deliver doses by reducing the air gap between the patient and bolus.

Comparison of Two Different Immobilization Devices for Pelvic Region Radiotherapy in Tomotherapy

  • Kim, Dae Gun;Jung, James J;Cho, Kwang Hwan;Ryu, Mi Ryeong;Moon, Seong Kwon;Bae, Sun Hyun;Ahn, Jae Ouk;Jung, Jae Hong
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.250-257
    • /
    • 2016
  • The purpose of this study was to compare the patient setup errors of two different immobilization devices (Feet Fix: FF and Leg Fix: LF) for pelvic region radiotherapy in Tomotherapy. Thirty six-patients previously treated with IMRT technique were selected, and divided into two groups based on applied immobilization devices (FF versus LF). We performed a retrospective clinical analysis including the mean, systematic, random variation, 3D-error, and calculated the planning target volume (PTV) margin. In addition, a rotational error (angles, $^{\circ}$) for each patient was analyzed using the automatic image registration. The 3D-errors for the FF and the LF groups were 3.70 mm and 4.26 mm, respectively; the LF group value was 15.1% higher than in the FF group. The treatment margin in the ML, SI, and AP directions were 5.23 mm (6.08 mm), 4.64 mm (6.29 mm), 5.83 mm (8.69 mm) in the FF group (and the LF group), respectively, that the FF group was lower than in the LF group. The percentage in treatment fractions for the FF group (ant the LF group) in greater than 5 mm at ML, SI, and AP direction was 1.7% (3.6%), 3.3% (10.7%), and 5.0% (16.1%), respectively. Two different immobilization devices were affected the patient setup errors due to different fixed location in low extremity. The radiotherapy for the pelvic region by Tomotherapy should be considering variation for the rotational angles including Yaw and Pitch direction that incorrect setup error during the treatment. In addition the choice of an appropriate immobilization device is important because an unalterable rotation angle affects the setup error.

전립선암의 방사선치료 시 직장풍선의 유용성 평가 (Rectal Balloon for the Immobilization of the Prostate Internal Motion)

  • 이상규;백종걸;김주호;전병철;조정희;김동욱;나수경;송태수;조재호
    • 대한방사선치료학회지
    • /
    • 제17권2호
    • /
    • pp.113-124
    • /
    • 2005
  • 목 적 : 전립선암의 방사선치료에서 전립선의 움직임을 최소화하고 직장 벽의 선량한계를 극복할 수 있는 방법으로 직장 풍선을 사용하여 치료 부작용을 줄이고 환자 setup시 직장풍선의 위치 재현성을 분석하며 임상치료에서의 유용성을 연구하였다. 대상 및 방법 : 본원에서 전립선암에 방사선치료를 위해 내원한 환자 5명를 대상으로 하였다. 각각의 환자마다. 자체 제작한 직장풍선을 삽입하고, 주사기를 이용하며 60 cc의 공기를 주입 후 치료 초기, 중기, 후기 3회에 걸쳐 CT Simulation 영상을 획득하여 Pinnacle $(ADAC)^(R)$내 자동영상융합프로그램인 Syntegra를 이용하며 최초 영상에 나머지 두 영상을 융합시켰다(CT to CT fusion). 직장풍선의 재현성을 확인하기 위하여 치골에서 직장풍선까지 중심과 양 외측으로 3개의 일직선을 긋고 각각의 좌표점을 찾아 각 영상의 위치변화를 정량적으로 분석하였다. 자동 Contouring기능을 이용하며 매 환자의 영상에서 직장풍선의 중심점 위치와 용적을 구하였다. 세기조절방사선치료를 받은 환자에서는 직장풍선을 삽입한 경우와 삽입하지 않은 CT영상을 얻어 치료계획을 비교함으로써 직장풍선의 유용성을 확인하였다. 결 과 : 각각의 환자에서 얻어진 영상의 용적은 일정하였다. 직장풍선의 재현성을 의미하는 치골에서 직장풍선까지의 거리는 중심점이 $2.1{\pm}1.7mm$, 오른쪽 $2.3{\pm}2.2mm$, 왼쪽 $2.0{\pm}1.6mm$이었다. 직장풍선의 편향은 좌우 $2.4{\pm}1.6mm$, 전후 $3.1{\pm}2.5mm$, 상하 $5.6{\pm}3.5mm$였다. 세기조절방사선치료 계획에서 직장풍선의 삽입한 경우와 삽입하지 않은 경우의 비교결과 최대점 선량은 직장풍선을 삽입한 경우 63.3 Gy로 미삽입의 57.2 Gy보다 높았다. 하지만, 직장 벽의 평균 선량은 사용한 경우 36.6 Gy, 미사용 시 41 .5 Gy였으며, 40 Gy가 조사되는 직장 벽의 용적은 각각 33.8%와 60%로 직장풍선을 사용한 경우에 적은 선량이 조사되어 직장의 선량체적히스토그램 (DVH)은 향상되었다. 결 론 : 직장풍선의 사용 시 후방경계를 2.5 mm이내로 일정하게 유지할 수 있었고, 직장풍선의 위치 재현성이 정확함을 알 수 있었다. 이는 움직임이 많은 전립선암에 직장풍선의 사용으로 치료용적을 줄이고 인접한 직장체적을 줄여 방사선선량 체적분포의 향상으로 생각된다. 본 연구는 자체제작한 직장풍선의 재현성 및 유용성의 정확성을 보여줌으로서 향후 임상치료에 활용할 수 있을 것으로 사료된다.

  • PDF

원발 혹은 재발성 비소세포 폐암 환자에서 사이버나이프률 이용한 체부 방사선 수술의 치료 결과 (Treatment Results of CyberKnife Radiosurgery for Patients with Primary or Recurrent Non-Small Cell Lung Cancer)

  • 김우철;김헌정;박정훈;허현도;최상현
    • Radiation Oncology Journal
    • /
    • 제29권1호
    • /
    • pp.28-35
    • /
    • 2011
  • 목 적: 초기 비소세포성 폐암 환자에서 수술적 절제 이외의 국소 치료로 최근 방사선 수술의 사용이 늘고 있다. 이에 저자들은 초기 혹은 재발한 비소세포성 폐암 환자를 대상으로 시행한 체부 방사선 수술의 치료 결과를 분석하여 그 유용성을 알아 보고하고자 한다. 대상 및 방법: 비소세포성 폐 종양에 대하여 방사선 수술이 시행되었던 24명의 환자, 28 lesion에 대하여 후향적 분석을 시행하였다. 이 중 원발성 종양은 19명 재발한 환자는 5명이었고 재발한 환자 5명 중 3명이 이전 치료 부위에서 재발한 환자 이었다. 원발성 종양 19명 중에서 4명은 외부 방사선 치료 후 추가로 방사선 수술을 시행 받았다. 24명의 초기 병기는 IA, IB, IIA, IIB, IIIA, IIIB, IV가 각각 7, 3, 2, 2, 3, 1, 6명이었고, 방사선 수술 당시의 T 병기는 T1 lesion이 13곳, T2가 12곳, T3가 3곳이었다. 방사선 수술은 6 MV X-ray를 이용하였고 planning target volume 1 (PTV1)에 총 방사선량 15~60 Gy(median, 50 Gy)를 3회 혹은 5회에 걸쳐 처방하여 시행하였다. 중앙 추적관찰기간은 469일이었다. 결 과: 28곳의 GTV는 0.7~108.7 mL (median, 22.9 m L)이었고, PTV1 은 5.3~184.8 mL (median, 65.4 m L)이었다. 3개월 반응률은 complete response (CR) 14곳, partial response (PR) 11곳, stable disease (SD) 3곳이었고, 마지막 추적에서의 치료반응은 CR 13곳, PR 9곳, SD 2곳, progressive disease (PD) 4곳이었다. 원발종양으로 초기 병기 IA, IB 10명에서는 50일만에 1명이 폐렴으로 사망하였고 1명이 국소재발 하였으나 나머지 환자는 6개월에서 2년간 국소재발 없이 추적관찰 되고 있으며, IIA-IIB 환자는 4명으로 환자 수가 적어서 뚜렷한 결론을 내리기 어려웠고, 재발성 폐암 환자 5명을 포함하는 10명의 IIIA-IV 병기에서는 사망 3명, 국소재발 1명, loco-regional failure 1명, regional failure 2명으로 좋지 않은 치료 결과를 보였다. 이 중에서 방사선 수술을 시행한 장소에서 재발한 경우는 총 28 1esion 중 4곳으로 85.8%의 국소제어율을 보였다. 방사선치료 양은 biologically equivalent dose (BEd) 100 $Gy_{10}$ 이하인 8 lesion 중에서 3 lesion에서 국소 재발하여 100 $Gy_{10}$ 이상인 20 lesion 중에서는 1 lesion에서만 재발한 경우보다 나빴다. 또한 중앙부의 종양과 방사선수술 당시의 병기가 T2 이상인 경우가 재발이 많았다. 결 론: 비소세포성 폐암환자에서 사이버나이프를 이용한 체부 방사선 수술은 부작용이 적으면서 높은 국소제어율을 얻을 수 있는 치료이며, 주변부의 T1 병기의 폐암에 대해서 BED 100 $Gy_{10}$ 이상의 방사선 치료가 국소제어율을 높이는데 도움이 된다고생각된다.

동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발 (Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study)

  • 이석;이상훈;신동호;양대식;최명선;김철용
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.122-125
    • /
    • 2004
  • 폐, 간 등의 상 복부에 위치한 종양의 방사선 조사 체적은 호흡에 의한 종양의 이동을 포함하기 때문에 방사선 조사체적이 증가되어 방사선 독성 및 정상조직 선량이 증가하게 된다. 이러한 문제점을 극복하기 위해 동 팬텀과 초음파센서를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득하고, 획득한 데이터의 역 값을 이용해 환자침대를 조절해줄 수 있는 호흡운동 조절 방사선치료 기술을 개발하고자 한다. 호흡운동에 의한 환자 체표면의 움직임을 평가하기 위해 제작한 팬텀은 조정기(BS II, 20 Mhz, 8K Byte), 센서(Ultra-Sonic, range 3 cm${\sim}$3 m), Computer(RS232C), Servo Motor (Torque 2.3 Kg)등으로 구성하였고, 제어와 구동을 위한 획득-보정-분석 프로그램을 작성하였다. 최대 2 cm 범위 내에서 팬텀을 움직이게 하였고, 팬텀의 움직임과 보정이 순차적으로 일어나도록 프로그램 하였으며, x, y, z가 연속적으로 움직이도록 구성하였다. 임의의 움직임 데이터(유격이 2 cm이 되도록 하여 3차원 데이터 형태)를 입력하여 동 팬텀을 조정하고, 동시에 팬텀 움직임을 초음파 센서를 이용하여 획득한 후, 두 데이터 간의 비교, 분석을 시행하였다. 이후 쥐(Guinea-pig, about 500g)를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득한 후 획득한 데이터의 역 값으로 팬텀을 구동시킴으로써 실시간 호흡운동 조절 방사선치료 기술을 평가하였다. 팬텀 실험에서 3 차원 입력데이터에 대한 팬텀 보정 데이터 간의 정확성을 시간에 대한 거리 값으로 비교한 결과 ${\pm}$1% 이내의 정확성을 알 수 있었고, 이에 필요한 보정시간은 2.34 ${\times}$ 10-4 초임을 알 수 있었다. 또한 동물 실험에서도 동일한 방법으로 시간에 대한 거리 그래프와 획득-보정 간의 지연 시간 등을 분석한 결과 팬텀 데이터와 같은 결과를 얻을 수 있었다. 팬텀, 동물 실험 모두에서 시간에 대한 거리 값과 각각의 경우에 획득-보정 간의 지연 시간을 분석한 결과 데이터 값은 ${\pm}$1%이내에서 일치하였으며, 데이터 획득-보정 지연 시간은 2.34 ${\times}$ 10-4 초 이내 즉, 실시간으로 얻을 수 있어 새로운 호흡운동 조절 방사선치료 기술의 임상적용에의 가능성을 확인할 수 있었다.