• Title/Summary/Keyword: Plane of motion

Search Result 785, Processing Time 0.021 seconds

VLSI Design for Motion Estimation Based on Bit-plane Matching (비트 플레인 정합에 의한 움직임 추정기의 VLSI 설계)

  • Go, Yeong-Gi;O, Hyeong-Cheol;Go, Seong-Je
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.5
    • /
    • pp.509-517
    • /
    • 2001
  • Full-search algorithm requires large amount of computation which causes time delay or very complex hardware architecture for real time implementation. In this paper, we propose a fast motion estimator based on bit-plane matching, which reduce the computational complexity and the hardware cost. In the proposed motion estimator, the conventional motion estimation algorithms are applied to the binary images directly extracted from the video sequence. Furthermore, in the proposed VLSI motion estimator, we employ a Pair of processing cores that calculate the motion vector continuously By controlling the data flow in a systolic fashion using the internal shift registers in the processing cores, we avoid using SRAM (local memory) so that we remove the time overhead for accessing the local memory and adopt lower-cost fabrication technology. We modeled and tested the proposed motion estimator in VHDL, and then synthesized the whole system which has been integrated in a 0.6-$\mu$m triple-metal CMOS chip of size 8.15 X 10.84$\textrm{mm}^2$.

  • PDF

Experimental Investigation of Unsteady Pressure Generated by Oscillating Outer Cylinder (진동하는 외부 실린더에 의해 유발되는 비정상 압력의 실험적 고찰)

  • 심우건
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.2
    • /
    • pp.519-526
    • /
    • 1995
  • Experiments have been performed to test the analytical tools developed concurrently for the motion-related unsteady pressure in annular passages. The outer cylindrical body was oscillated by a shaker in either rocking motion about a hinge-point or lateral translation motion. In the equilibrium configuration the two bodies are either concentric or eccentric, in the plane of oscillation or normal to it. The unsteady pressure generated by the oscillatory motion with low amplitudes (displacement/radius) was measured on wall of the fixed inner cylinder at various axial and azimuthal locations. The unsteady pressure were compared with theoretical predictions, and agreement was found to be within 10%. Experiments have been shown that the effect of flow velocity on the unsteady pressure is minimal and the pressure increases more or less with oscillatory motion, for low flow velocities (Re = 2 900).

Detecting Collisions in Graph-Driven Motion Synthesis for Crowd Simulation (군중 시뮬레이션을 위한 그래프기반 모션합성에서의 충돌감지)

  • Sung, Man-Kyu
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.1
    • /
    • pp.44-52
    • /
    • 2008
  • In this paper we consider detecting collisions between characters whose motion is specified by motion capture data. Since we are targeting on massive crowd simulation, we only consider rough collisions, modeling the characters as a disk in the floor plane. To provide efficient collision detection, we introduce a hierarchical bounding volume, the Motion Oriented Bounding Box tree (MOBB tree). A MOBBtree stores space-time bounds of a motion clip. In crowd animation tests, MOBB trees performance improvements ranging between two and an order of magnitude.

Characteristics of ROM and EMG to Balance Training in Unstable Plate System: Primary Study (균형 훈련 플레이트 시스템을 이용한 생체역학적 특성 연구)

  • Jun, SungChul;Lim, HeeChul;Lee, ChangHyung;Kim, TaeHo;Jung, DukYoung;Chun, KeyoungJin
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.235-239
    • /
    • 2015
  • The purpose of this study was to investigate the unstable plate system for the advanced balance ability. 7 male volunteers (age $33.7{\pm}1.2$ years, height $174.7{\pm}3.8cm$, weight $86.0{\pm}3.6kg$, BMI $28.2{\pm}2.0kg/m^2$) performed the partial squat motion on the shape of CAP type(${\cap}$) and BOWL type(${\cup}$) plate system. The range of motion (ROM) and muscle activation were acquired by the motion analysis system and the EMG system. Results of ROMs of the CAP type plate system were shown the widely range of the deviation in the ankle joint on the sagittal plane (sagittal plane - hip joint $10.7^{\circ}$ > $5.4^{\circ}$, knee joint $16.3^{\circ}$ > $6.4^{\circ}$, ankle joint $18.8^{\circ}$ > $6.3^{\circ}$ ; transverse plane - hip joint $3.5^{\circ}$ > $1.8^{\circ}$, knee joint $5.3^{\circ}$ > $3.4^{\circ}$, ankle joint $11.3^{\circ}$ > $5.3^{\circ}$ ; frontal plane - hip joint $0.9^{\circ}$ > $0.5^{\circ}$, knee joint $0.8^{\circ}$ > $0.6^{\circ}$, ankle joint $4.8^{\circ}$ > $3.7^{\circ}$). Muscle activation results of the CAP type plate system were indicated higher in major muscles for balance performance than the BOWL type plate system (vastus lateralis 0.90 > 0.62, peroneus longus 0.49 > 0.21, biceps femoris 0.38 > 0.14, gastrocnemius 0.11 > 0.05). These findings may indicate that the CAP type plate system would expect better effectiveness in perform the balance training. This paper is primary study for developing balance skills enhancement training device.

The Effects of Trunk Movement and Ground Reaction Force during Sit to Stand Using Visual Feedback (시각 되먹임을 이용한 앉은 자세에서 일어서기 시 몸통의 동작과 지면 반발력에 미치는 영향)

  • Yeong-Geon Koh;Tae-Young Oh;Jae-Ho Lee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.2
    • /
    • pp.207-219
    • /
    • 2023
  • Purpose : This study was conducted to investigate the changes in trunk movement and ground reaction during sit to stand motion using visual feedback. Methods : Fifteen adults (average age: 23.53±1.77 years) participated in this study. An infrared reflective marker was attached to the body each participant for motion analysis, and the participants performed sit to stand motion while wearing a hat attached with a laser pointer, which provided visual feedback. First, the sit to stand action was repeated thrice without obtaining any visual feedback, followed by a three minute break. Next, the laser pointers attached to hats were irradiated on a whiteboard, located at a distance of 5 m in front of the chairs, on which the participants sat; a baseline was set, and the participants performed stand up movements three times under this condition. A visual feedback was provided to the participants to prevent the laser pointers from crossing the set baseline. During each stand-up movement, the position of the reflective marker attached to the subject's body was recorded in real time using an infrared camera for motion analysis. The trunk movement and ground reaction force were extracted through recorded data and analyzed according to the presence or absence of visual feedback. Results : The results indicated that in the presence of a visual feedback during the sit-to-stand movements, the range of motion of the trunk and hip joints decreased, whereas that of the knee and ankle joints increased in the sagittal plane. The rotation angle of the trunk in the horizontal plane decreased. The left and right movement speed of the center of pressure increased, the pressing force decreased, and the forward and backward movement speed of the trunk decreased. Conclusion : The results suggest that the efficiency and stability of the stand up movement of a body increase when a visual feedback is provided.

Developement of Measuring Units of Space Motion Accuracy in Machining Center (Machining Center의 공간정도 측정장치의 개발)

  • Kim, Young Seuk;Namgung, Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.2
    • /
    • pp.37-47
    • /
    • 1995
  • In recent years, it has been variously developed for testing the accuracy of circular motion of NC machine tools, for example Telescoping Ball Bar Method by Bryan, Circular test Method by Knapp and $r^{-{\theta} }$ Method by Tsutsumi etc., but these methods are all 2-dimentional measuring methods on plane. These simple methods of circular motion accuracy test of NC machine tools have been studied by many reserchers as above, but it is not yet settled in the code of measuring methods of motion errors of NC machine tools, because of errors of measuring units and sensors, and also especially the difficulties of centering of measuring units and the spindle of machining center. In this paper, in use of 2 rotary encoders and 1 magnetic type linear scale with resolution of 0.5 .mu. m, it has become possible for measuring of 3 dimentional space motion accuracy.

  • PDF

Nonlinear Motion Analysis of FPSO with Turret Mooring System (터렛계류된 FPSO의 비선형 운동 해석)

  • 임춘규;이호영
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.1
    • /
    • pp.20-27
    • /
    • 2003
  • The FPSO is moored by mooring lines to keep the position of it. The nonlinear motion analysis of the moored FPSO must be carried out in the initial design stage because sea environments affect motion of it. In this paper, the mathematical model is based on the slow motion maneuvering equations in the horizontal plane considering wave, current and wind forces. The direct integration method is employed to estimate wave loads. The current forces are calculated by using mathematical model of MMG. The turret mooring forces are quasi-statically evaluated by using the catenary equation. The coefficients of a model for wind forces are calculated from Isherwood's experimental data and the variation of wind speed is estimated by wind spectrum according to the guidelines of API-RP2A. The nonlinear motions of FPSO are simulated under external forces due to wave, current, wind including mooring forces in time domain.

Deployment or Retraction of Beam with Large Rotational Motion (대각 선회하는 보의 전개 및 수납)

  • 김상원;김지환
    • Journal of KSNVE
    • /
    • v.11 no.1
    • /
    • pp.111-117
    • /
    • 2001
  • Present work deals with a study on the deployment or retraction of cantilever beam that includes the rigid-body motion of large displacement of beam through the translational and rotational motions in 2-dimensional plane. The equations of motion are derived with respect to non-Cartesian coordinate system. In the formulation of equations of motion, shear deformations and geometrically non-linear effect are included. An assumed mode method is applied and numerical convergence characteristics are studied also. Types of motion of the moving beam are assumed to be classified as‘slow’or‘fast’motion, and the dynamic characteristics are investigated.

  • PDF

Novel Methods for Spatial Position Control of a Plate In the Conductive Plate Conveyance System Using Magnet Wheels (자기차륜을 이용한 전도성 평판 이송 시스템에서 평판 위치 제어를 위한 새로운 방법)

  • Jung, Kwang Suk
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.6
    • /
    • pp.1010-1017
    • /
    • 2013
  • Two-axial electrodynamic forces generated on a conductive plate by a partially shielded magnet wheel are strongly coupled through the rotational speed of the wheel. To control the spatial position of the plate using magnet wheels, the forces should be handled independently. Thus, three methods are proposed in this paper. First, considering that a relative ratio between two forces is independent of the length of the air-gap from the top of the wheel, it is possible to indirectly control the in-plane position of the plate using only the normal forces. In doing so, the control inputs for in-plane motion are converted into the target positions for out-of-plane motion. Second, the tangential direction of the open area of the shield plate and the rotational speed of the wheel become the new control variables. Third, the absolute magnitude of the open area is varied, instead of rotating the open area. The forces are determined simply by using a linear controller, and the relative ratio between the forces creates a unique wheel speed. The above methods were verified experimentally.

Development of Stereoscopic PIV Measurement Technique and Its Application to Wake behind an Axial Fan (Stereoscopic PIV 기법의 개발과 이를 이용한 축류 홴 후류의 유동해석)

  • Yun, Jeong-Hwan;Lee, Sang-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.2
    • /
    • pp.362-373
    • /
    • 2002
  • A stereoscopic PIV (SPIV) measurement system based on the translation configuration was developed and applied to the flow behind a forward-swept axial-fan. Measurement of three orthogonal velocity components is essential for flow analysis of three-dimensional flows such as flow around a fan or propeller. In this study, the translation configuration was adopted to calculate the out-of-plane velocity component from 2-D PIV data obtained from two CCD cameras. The error caused by the out-of-plane motion was estimated by direct comparison of the 2-D PIV and 3-D SPIV results that measured from the particle images captured simultaneously. The comparison shows that the error ratio is relatively high in the region of higher out-of-plane motion near the axial fan blade. The turbulence intensity measured by the 2-D PIV method is bigger by about 5.8% in maximum compared with that of the 3-D SPIV method. The phase-averaged velocity field results show that the wake behind an axial fan has a periodic flow structure with respect to the blade phase and the characteristic flow structure is shifted downstream in the next phase.