• Title/Summary/Keyword: Placement Length

Search Result 254, Processing Time 0.042 seconds

The effects of tissue punch diameter on healing around implants in flapless implant surgery (무피판 임플란트 수술에서 연조직 펀치의 크기가 임플란트 주위 조직의 치유에 미치는 영향)

  • Lee, Du-Hyeong;Jeong, Seung-Mi;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.301-311
    • /
    • 2009
  • Statement of problem: Flapless implant surgery using a soft tissue punch device requires a circumferential excision of the mucosa at the implant site. To date, Although there have been several reports on clinical outcomes of flapless implant surgeries, there are no published reports that address the appropriate size of the soft tissue punch for peri-implant tissue healing. Purpose: In an attempt to help produce guidelines for the use of soft tissue punches, this animal study was undertaken to examine the effect of soft tissue punch size on the healing of peri-implant tissue in a canine mandible model. Material and methods: Bilateral, edentulated, flat alveolar ridges were created in the mandibles of six mongrel dogs. After a three month healing period, three fixtures (diameter, 4.0 mm) were placed on each side of the mandible using 3 mm, 4 mm, or 5 mm soft tissue punches. During subsequent healing periods, the peri-implant mucosa was evaluated using clinical, radiological, and histometric parameters, which included Gingival Index, bleeding on probing, probing pocket depth, marginal bone loss, and vertical dimension measurements of the peri-implant tissues. Results: The results showed significant differences (P <0.05) between the 3 mm, 4 mm and 5 mm tissue punch groups for the length of the junctional epithelium, probing depth, and marginal bone loss during healing periods after implant placement. When the mucosa was punched with a 3 mm tissue punch, the length of the junctional epithelium was shorter, the probing depth was shallower, and less crestal bone loss occurred than when using a tissue punch with a diameter $\geq$ 4 mm. Conclusion: Within the limit of this study, the size of the soft tissue punch plays an important role in achieving optimal healing. Our findings support the use of tissue punch that 1 mm smaller than implant itself to obtain better peri-implant tissue healing around flapless implants.

A 15-year clinical retrospective study of Br${\aa}$nemark implants (Br${\aa}$nemark 임플란트의 15년 임상적 후향 연구)

  • Park, Hyo-Jin;Cho, Young-Ye;Kim, Jong-Eun;Choi, Yong-Geun;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.61-66
    • /
    • 2012
  • Purpose: This study was to compare the cumulative survival rate (CSR) of Br${\aa}$nemark machined surface implants and TiUnite$^{TM}$ imlants and to analyze association between risk factors and the CSR of the implants. Materials and methods: A retrospective study design was used to collect long-term follow-up clinical data from dental records of 156 patients treated with 541 Br${\aa}$nemark machined and TiUnite$^{TM}$ implants at Korea University Guro hospital in South Korea from 1993 through 2008. Machined implant and TiUnite$^{TM}$ implant were compared by CSR. Exposure variables such as gender, systemic disease, location, implant length, diameter, prosthesis type, opposing occlusion type, date of implant placement, type of edentulous space, abutment type, existence of splinting with natural teeth, and existence of cantilever were collected. Life table analysis was undertaken to examine the CSR. Cox regression method was conducted to assess the association between potential risk factors and overall CSR (${\alpha}$=.05). Results: Patient ages ranged from 16 to 75 years old (mean age, 51 years old). Implants were more frequently placed in men than women (94 men versus 63 women). Since 1993, 264 Br${\aa}$nemark machined implants were inserted in 79 patients and since 2001, 277 TiUnite$^{TM}$ implants were inserted in 77 patients. A total survival rate of 86.07% was observed in Br${\aa}$nemark and Nobel Biocare TiUnite$^{TM}$ during 15 years. A survival rate of machined implant during 15 years was 82.89% and that of TiUnite$^{TM}$ implant during 5 years was 98.74%. The implant CSR revealed lower rates association with several risk factors such as, systemic disease, other accompanied surgery, implant location, and Kennedy classification. Conclusion: Clinical performance of Br${\aa}$nemark machined and TiUnite$^{TM}$ implant demonstrated a high level of predictability. In this study, TiUnite$^{TM}$ implant was more successful than machined implant. The implant CSR was associated with several risk factors.

A Study on the Stress Distribution of Condylar Region and Edentulous Mandible with Implant-Supported Cantilever Fixed Prostheses by using 3-Dimensional Finite Element Method (임플란트 지지 캔틸레버 고정성 보철물 장착시 과두와 하악골의 응력 분포에 관한 3차원 유한요소법적 연구)

  • Kim, Yeon-Soo;Lee, Sung-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.4
    • /
    • pp.283-305
    • /
    • 2001
  • The purpose of this study was to analyze the stress distribution of condylar regions and edentulous mandible with implant-supported cantilever prostheses on the certain conditions, such as amount of load, location of load, direction of load, fixation or non-fixation on the condylar regions. Three dimensional finite element analysis was used for this study. FEM model was created by using commercial software, ANSYS(Swanson, Inc., U.S.A.). Fixed model which was fixed on the condylar regions was modeled with 74323 elements and 15387 nodes and spring model which was sprung on the condylar regions was modeled with 75020 elements and 15887 nodes. Six Br${\aa}$nemark implants with 3.75 mm diameter and 13 mm length were incorporated in the models. The placement was 4.4 mm from the midline for the first implant; the other two in each quardrant were 6.5 mm apart. The stress distribution on each model through the designed mandible was evaluated under 500N vertical load, 250N horizontal load linguobuccally, buccal 20 degree 250N oblique load and buccal 45 degree 250N oblique load. The load points were at 0 mm, 10 mm, 20 mm along the cantilever prostheses from the center of the distal fixture. The results were as follows; 1. The stress distribution of condylar regions between two models showed conspicuous differences. Fixed model showed conspicuous stress concentration on the condylar regions than spring model under vertical load only. On the other hand, spring model showed conspicuous stress concentration on the condylar regions than fixed model under 250N horizontal load linguobuccally, buccal 20 degree 250N oblique load and buccal 45 degree 250N oblique load. 2. Fixed model showed stress concentration on the posterior and mesial side of working and balancing condylar necks but spring model showed stress concentration on the posterior and mesial side of working condylar neck and the posterior and lateral side of balancing condylar neck under vertical load. 3. Fixed model showed stress concentration on the posterior and lateral side of working condylar neck and the anterior and mesial side of balancing condylar neck but spring model showed stress concentration on the anterior sides of working and balancing condylar necks under horizontal load linguobuccally. 4. Fixed model showed stress concentration on the posterior side of working condylar neck and the posterior and lateral side of balancing condylar neck but spring model showed stress concentration on the anterior side of working condylar neck and the anterior and lateral side of balancing condylar neck under buccal 20 degree oblique load. 5. Fixed model showed stress concentration on the anterior and lateral side of working condylar neck and the posterior and mesial side of balancing condylar neck but spring model showed stress concentration on the anterior side of working condylar neck and the anterior and lateral side of balancing condylar neck under buccal 45 degree oblique load.. 6. The stress distribution of bone around implants between two models revealed difference slightly. In general, magnitude of Von Mises stress was the greatest at the bone around the most distal implant and the progressive decrease more and more mesially. Under vertical load, the stress values were similar between implant neck and superstructure vertically, besides the greatest on the distal side horizontally. 7. Under horizontal load linguobuccally, buccal 20 degree oblique load and buccal 45 degree oblique load, the stress values were the greatest on the implant neck vertically, and great on the labial and lingual sides horizontally. After all, it was considered that spring model was an indispensable condition for the comprehension of the stress distributions of condylar regions.

  • PDF

Clinical Results alter Pulmonary Endarterectomy as a Curative Surgical Method in Chronic Thromboembolic Pulmonary Hypertension: an Approach to Operative Classification of Thromboembolic Disease (만성 폐동맥 색전증의 치료로서 내막제거술의 임상적 결과: 색전증 분류에 따른 접근)

  • Lim, Ju-Yong;Lee, Jae-Won;Kim, Jeong-Won;Jung, Sung-Ho;Je, Hyoung-Gon;Song, Hyun;Chung, Cheol-Hyun;Choo, Suk-Jung
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.591-597
    • /
    • 2008
  • Background: Pulmonary endarterectomy is widely accepted as a treatment for chronic thromboembolic pulmonary hypertension. Based on our experiences, we sought to find ways to reduce perioperative complications and to improve surgical outcomes in patients undergoing pulmonary endarterectomy. Material and Method: This study was designed as a retrospective analysis of 20 patients with pulmonary hypertension who underwent pulmonary endarterectomy between January 1998 and March 2008. All patients presented with chronic dyspnea. Deep vein thrombosis (DVT) was the major cause of chronic pulmonary thromboembolism (55%). Seventeen patients (85%) underwent inferior vena cava (IVC) filter placement. Thirteen patients underwent surgery under total circulatory arrest, while the others underwent surgery while on low flow cardiopulmonary bypass. Concomitant tricuspid annuloplasty was done in 6 patients (66%) whose tricuspid regurgitation was as severe as grade IV/IV. The mean follow-up duration was $45{\pm}32$ months. Result: Using of University of California, San Diego (UCSD), thromboembolism classification, 4 patients (20%) were type 1, 8 patients (40%) were type II, and 8 patients (40%) were type III. Right ventricular systolic pressure was reduced significantly from $77{\pm}29$ mmHg to $37{\pm}19$ mmHg after pulmonary endarterectomy (p<0.001). The degree of tricuspid regurgitation and the NYHA functional class were all improved postoperatively. Reperfusion edema occurred in 7 cases (35%). The incidence of reperfusion edema was higher in the UCSD type III group than in the other group (25% vs 50%, p=0.25) and the length of postoperative intensive care unit stay was longer in type III group ($5{\pm}2$ days vs $9{\pm}7$ days, p=0.07). The early mortality rate was 10%, and the late mortality rate was 15% (n=3); one death was due to progression of underlying non-Hodgkin's lymphoma, and the other deaths were related to recurrent thromboembolism and persistent pulmonary hypertension, respectively. Conclusion: Pulmonary endarterectomy, as a curative surgical method for treating chronic thromboernbolic pulmonary hypertension, should be performed aggressively in patients diagnosed with chronic thromboembolic pulmonary hypertension, and an effort should be made to reduce the frequency of perioperative complications and to improve surgical outcomes.

EMG AND CEPHALOMETRIC STUDY ON CHANCES IN UPPER AIRWAY STRUCTURES AND MUSCLE ACTIVITIES ACCORDING TO THE USE OF MANDIBULAR REPOSITIONING APPLIANCE AND BODY POSTURE IN OSA PATIENTS (폐쇄성 수면 무호흡증 환자에 있어서 하악 재위치 장치 장착과 체위에 따른 상기도 구조와 근활성도의 변화에 관한 EMG 및 두부방사선학적 연구)

  • Park, Young-Chel;Pae, Eung-Kwon;Lee, Jeung-Gweon;Lee, Jong-Suk;Kim, Tae-Kwan
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.547-561
    • /
    • 1998
  • Obstructive sleep apnea (OSA) is a disorder characterized by repetitive episode of upper airway collapse during sleep. Recent studies showed that not only the anatomic factors but the physiologic factors of the upper airway also have effcts on the occurrence of apnea and that the genioglossus muscle also plays an important role in the maintenance of the upper airway. A variety of therapies were performed to treat OSA, and among them the use of mandibular repositioning appliances showed reasonable results. But there is still a lack of research on the structural and physiological mechanism upon the use of mandibular repositioning appliances. The author selected 26(male 17, female 9) OSA patients that came to the Yonsei University Dental Hospital, Department of Orthodontics, and 20 normal adults (male 10, female 10) and took cephalometric radiographs of them in a supine position before and after the placement of the mandibular repositioning appliance to see the structural changes of the upper airway and compare the therapeutic effects between the two groups. We also studied the waking genioglossus muscle activity in OSA patients and investigated the difference in the electromyogram of the genioglosssus muscle upon the change in body posture and the use of mandibular repositioning appliance. Following results were obtained. 1. Among the cephalometric measurements of the upper airway structure, the length of the soft palate, maximum thickness of the soft Palate and SPAS, MAS, VAL, H-H1, MP-H showed statistically significant differences between the normal and OSA groups, but the IAS and EAS showed no statistically significant differences between the two groups. 2. In both the normal and OSA groups, as the epiglottis moved forward on wearing the mandibular repositioning appliance, the epiglottis level of the upper airway increased and the maximum thickness of the soft palate changed and the hyoid bone also moved forward, but the IAS in both groups showed various results and the effect of the mandibular repositioning appliance on the structure of the upper airway was different in the two groups. 3. Upon changing the position, the electromyogram of the genioglossus muscle showed a increasing tendency but there was no statistically significant differences, and when the mandibular repositioning appliance were worn there was a statistically significant increase in the electromyogram of the genioglossus muscle in both the upright and supine positions. The mandibular repositioning appliances not only have an effect on the anatomical structure of the upper airway but also on the physiology of the upper airway. There are different responses to the use of mandibular repositioning appliance between the normal and OSA groups therefore it could be considered to have the different physiology of the upper airway between the two groups.

  • PDF

Study of the re-osseointegration of implant fixture after mechanical unscrewing (임플란트 고정체의 의원성 동요 후 골 유착 반응에 관한 연구)

  • Jang, Ji-Hoon;Cho, Jin-Hyun;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.209-214
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate whether the re-osseointegration of the implants that had mechanical unscrewing possibly occurred or not. Furthermore, if it happened, the degree of re-osseointegration was evaluated by comparing with previous osseointegration. Materials and methods: The smooth implant (commercial pure titanium 99%) specimens, whose diameter and length was 3.75 mm, 4 mm, respectively were produced. Two implants were inserted into each tibia of 7 New Zealand female white rabbits weighing at least 3.0 kg. The torque removal force for each implant after 6 weeks of implants placement was measured and included in group I. The torque removal forces were assessed after the fixtures were re-screwed to original position and the subjects were allowed to have 4 more weeks for healing and included in group II. One rabbit was sacrificed after first measurement and produced 4 slide specimens in group I, and two rabbits were sacrificed after 2nd measurement, 7 slide specimens, in group II for histomorphologic investigations. All slide specimens were assessed based on the proportion of BIC (bone-implant contact) as well as CBa (Bone area in the cortical passage) value produced by counting the screw threads embedded in the compact bones under the optical microscopic analysis (${\times}20$). Statistical analysis was conducted to evaluate the torque removal force, BIC and CBa between group I and II. Results: As for the torque removal force, the result was $10.8{\pm}3.6$ Ncm for group I and $20.2{\pm}9.7$ Ncm for group II. Furthermore, the torque removal force of group II increased by 98.1% in average compared to group I (P<.05). On the other hand, histomorphologic analysis displayed that there was no statistical significance in BIC and CBa values between group I and the group II (P>.05), and RT/BIC and RT/CBa between group I and group II were statistically significant (P<.05). Conclusion: It is possible to obtain more substantial re-osseointegration within shorter periods than the period needed for the initial osseointegration in case of iatrogenically unscrewed implants.

Comparative analysis of RN-BSN Program in Korea and U. S. A. (간호학사 편입학제도의 교과과정 비교분석)

  • Lee Ok-Ja;Kim Hyun-Sil
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.3
    • /
    • pp.99-116
    • /
    • 1997
  • In response of the increasing demand for professional degree in nursing, some university in Korea offers RN-BSN program for R. N. from diploma in nursing. However, RN-BSN program in Korea is in formative period. Therefore, the purpose of this survey study is for the comparative analysis of RN-BSN curriculum in Korea and U.S.A. In this study, subjects consisted of 18 department of nursing in university and 5 RN-BSN programs in Korea and 18 department of nursing in university and 12 RN-BSN programs in U.S.A. For earn the degree of Bachelor of Science in Nursing, the student earns 134 of mean credits in U.S.A., whereas 150.3 of mean credits in Korea. The mean credit for clinical pratice is 30.1 in U.S.A., whereas 23.9 in Korea. Students are assigned to individually planned clinical experiences under the direction of a preceptor in U.S.A. In RN-BSN program, total mean credits through lecture and clinical practice for earn the degree of BSN is 35.5(lecture : 27.7, practice ; 7.8)in U.S.A., whereas,48.1 (lecture;42.1, practice;6.0) in Korea. RN-BSN program can be taken on a full-or-part time basis in U.S.A., whereas didn't in Korea. Especially, emphasis is place on the advanced nursing practicum that focus on the role of the professional nurse in providing health care to individuals, families, and groups in community setting in U.S.A. 27.7 of mean credits was earned through lecture in U.S.A., whereas 42.1 of mean credits in Korea. It means that RN-BSN program in Korea is the lesser development in teaching method and appraisal method than in U.S.A. Students of RN-BSN program in U.S.A. can earns credit through CLEP, NLN achievement test, portfolio review session etc as well as lecture. Therefore, the authors suggests some recommendations for the development of curriculum of RN-BSN program in Korea based on comparative analysis of RN-BSN curricula in U.S.A. and Korea. 1. The curriculum of RN-BSN Program in nursing was required to do some alterations. Nursing care, today, is complex and ever changing. According to change of public need, RN-BSN curriculum intensified primary care program in community setting, geriatric nursing, marketing skill, computer language. 2. The various and new methods of earning credit should be developed. That is, the students will earn credits through the transfer of previous nursing college credits, accredited examination of university, advanced placement examination, portfolio review session, case study, report, self-directed learning and so on. Flexible teaching place should ile offered. 3. Flexible teaching place should be offered. The RN-BSN curriculum should accommodate each RN student's geographical needs and school/work schedule. Therefore, the university should search a variety of teaching places and the RN students can obtain their degrees comfortably throughout the teaching place such as lecture room inside the health care agency and establishment of the branch school in each student's residence area. 4. The RN-BSN program should offer a long distance education to place-bound RN student in many parts of Korea. That is, from the main office of university, the RN-BSN courses are delivered to many areas by Internet, EdNet (satellite telecommunication) and other non-traditional methods. 5. For allowing RN student to take nursing courses, program length should be various, depending upon the student's study/work schedule. That is, the various term systems such as semester, three terms, quarter systems and the student's status like full time or part time should be considered. Therefore, the student can take advantage of the many other educational and professional opportunities, making them available during the school year.

  • PDF

Estimation of Genetic Parameter for Linear Type Traits in Holstein Dairy Cattle in Korea (Holstein종 젖소의 선형심사형질에 대한 유전모수추정)

  • Lee, Ki-Hwan;Sang, Byung-Chan;Nam, Myoung-Soo;Do, Chang-Hee;Choi, Jae-Gwan;Cho, Kawng-Hyun
    • Journal of Animal Science and Technology
    • /
    • v.51 no.5
    • /
    • pp.345-352
    • /
    • 2009
  • This study utilized 332,625 records of linear type scores consisting for 15 primary traits, 22,175 final score and 84,612 pedigree information of 22,175 Holstein cows from 1993 to 2007 in Korea to estimate genetic parameters for 16 type traits. Genetic and error (co)variances between two traits selected from 16 traits were estimated using bi-trait pairwise analyses with DFREML package. The estimated heritabilities for stature (ST), strength (STR), body depth (BD), dairy form (DF), rump angle (RA), thurl width (TW), rear legs side view (RLSV), foot angle (FA), fore udder attachment (FUA), rear udder height (RUH), rear udder width (RUW), udder cleft (UC), udder depth (UD), front teat placement (FTP), front teat length (FTL) and final score (FS) were 0.31, 0.21, 0.25, 0.10, 0.29, 0.19, 0.09, 0.06, 0.12, 0.13, 0.12, 0.08, 0.26, 0.20, 0.28 and 0.15, respectively. ST had the highest positive genetic correlation with BD (0.90), while RLSV had the highest negative genetic correlation with FA (-0.56). RA had negative genetic correlation with most udder traits (-0.17~-0.02). Especially, RUW had the higher positive genetic correlation with STR (0.60), BD (0.62), and TW (0.49), however, UD had the higher negative genetic correlation with STR (-0.40) and BD (-0.40). FTL had negative genetic correlation with FUA, RUH, RUW, UC and UD. FS had positive genetic correlation with UC, UD and FTP (0.12, 0.18 and 0.20). However, additional research is needed on the use of these parameters in the genetic evaluation because estimated genetic and error variance-covariance matrices were not positive definite.

BONE DENSITY AND HISTOMORPHOMETRY ASSESSMENT OF DENTAL IMPLANT USING COMPUTERIZED TOMOGRAPHY (컴퓨터 영상을 이용한 임플란트 식립부위의 골밀도와 조직학적 연구)

  • Son, Jang-Ho;Choi, Byung-Hwan;Park, Soo-Won;Cho, Yeong-Cheol;Sung, Iel-Yong;Lee, Ji-Ho;Byun, Ki-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.136-142
    • /
    • 2009
  • Bone density in the recipient implant site seems to be an important factor for long term success of endosseous implants. Preoperative evaluation of bone density is very helpful to assist the clinician with the treatment planning of implant therapy. Accurate information on bone density will help the surgeon identify suitable implant sites, thereby improving the success rate of the procedure. Purpose; The aim of this study was to evaluate a correlation between bone density measured preoperatively with computerized tomography and histologically measured bone density by bone biopsy. Patients and methods; Twenty seven patients were selected. All the patients were in good health, with no systemic disorder and additional bone graft. Preoperatively the patients underwent CT scanning to evaluate Houmsfield Unit(HU). Each patients wore a surgical template for implant placement. During surgery 2mm in diameter and 6mm in length specimens were taken. Histomorphometric analysis was performed using digitalized image analysis software Axiovision 4.3. Also, the Resonance frequency analysis(RFA) and insertion torque values were recorded. Results; The highest histomorphometric values was found in the posterior mandible $32.3{\pm}3.8$, followed by $29.9{\pm}2.6$ for the posterior maxilla, $29.4{\pm}2.6$ for the anterior maxilla, $28.6{\pm}2.3$ for the anterior mandible(p=0.214). The hounsfield unit was $989.2{\pm}258.1$ in the posterior mandible, $845.0{\pm}241.5$ in the anterior maxilla, $744.5{\pm}92.6$ in the anterior mandible, $697.3{\pm}136.9$ in the posterior maxilla(p=0.045). This results may suggest that there are strong correlation between the histomorphometric values and hounsfield unit(r=0.760, p<0.05). The RF measurements were $81.9{\pm}2.4$ ISQ in the posterior mandible, $79.0{\pm}1.4$ ISQ in the anterior mandible, $78.3{\pm}4.6$ ISQ in the posterior maxilla, $76.5{\pm}5.0$ ISQ in the anterior maxilla(p=0.048). The insertion torque values was $43.2{\pm}4.2\;Ncm$ in the posterior mandible, $42.0{\pm}0.0\;Ncm$ in the anterior mandible, $41.3{\pm}4.1\;Ncm$ in the posterior maxilla, $40.8{\pm}3.8\;Ncm$ in the anterior maxilla(p=0.612). This results may suggest that there are statistical significance between the hounsfield unit and the insertion torque values(r=0.494, p<0.05), the histomorphometric values and the insertion torque values(r=0.689, p<0.05). But there was no correlation between histomorphometric values and ISQ. There was no statistical significance in age and gender effect on parameters. Conclusions; There was significant correlations between bone density and implant stability parameters. The bone density measurements using preoperative CT may help clinicians to predict primary stability before implant insertion, which is associated with implant survival rates.

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.