• Title/Summary/Keyword: Pitting

Search Result 536, Processing Time 0.03 seconds

REE Mineralization of Quy Hop Area in Nghe An Province, Northern Vietnam (베트남 북부 네안성 뀌홉지역 희토류 광화작용)

  • Lee, Jae-Ho;Jin, Kwang-Min;Heo, Chul-Ho
    • Journal of the Mineralogical Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.193-213
    • /
    • 2018
  • Soil geochemical exploration to check anomalies related to mineralization was carried out targeting around Quy Hop area within Nghe An province, Northern Vietnam. The interval of sampling are horizontal 250 m with 13 line and longitudinal 300 m with 25 line, resulting in 325 soil samples. Based on the result of soil geochemical exploration, the pitting survey was carried out targeting the grid point with high TREO content, resulting in 73 soil samples within 8 pits. The geology of the survey area are consisted of Ban Chieng biotite granite complex intruding Bu Khang formation comprising of schist, gneiss and limestone. In order to elucidate the source rock of monazite and xenotime confirmed from heavy sand, soil geochemical exploration was carried out. By ICP-MS result of soil samples, total REE oxide content of background amount is about 1.4 times of crustal abundance, depleting the light rare earth (about 0.2 times) and enriching the heavy rare earth (about 1.5 times). By ICP-MS result of pit soil samples, we identified TREO more than 1,000 ppm in 6 pits. It may be considered that REE ore bodies may develop in NE-SW direction, compared with the geochemical results of Quy Chau area.

A Method of Integrating Scan Data for 3D Face Modeling (3차원 얼굴 모델링을 위한 스캔 데이터의 통합 방법)

  • Yoon, Jin-Sung;Kim, Gye-Young;Choi, Hyung-Il
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.6
    • /
    • pp.43-57
    • /
    • 2009
  • Integrating 3D data acquired in multiple views is one of the most important techniques in 3D modeling. However, the existing integration methods are sensitive to registration errors and surface scanning noise. In this paper, we propose a integration algorithm using the local surface topology. We first find all boundary vertex pairs satisfying a prescribed geometric condition in the areas between neighboring surfaces, and then separates areas to several regions by using boundary vertex pairs. We next compute best fitting planes suitable to each regions through PCA(Principal Component Analysis). They are used to produce triangles that be inserted into empty areas between neighboring surfaces. Since each regions between neighboring surfaces can be integrated by using local surface topology, a proposed method is robust to registration errors and surface scanning noise. We also propose a method integrating of textures by using parameterization technique. We first transforms integrated surface into initial viewpoints of each surfaces. We then project each textures to transformed integrated surface. They will be then assigned into parameter domain for integrated surface and be integrated according to the seaming lines for surfaces. Experimental results show that the proposed method is efficient to face modeling.

Applications of Micro-Droplet Cell to Study of Localized Corrosion Resistance of Stainless Steels (스테인리스강의 국부부식 저항성 연구에 미세방울셀의 응용)

  • Kim Sung-Yu;Kim Hee-San
    • Journal of the Korean Electrochemical Society
    • /
    • v.9 no.2
    • /
    • pp.70-76
    • /
    • 2006
  • Micro-droplet cell with free droplet as a micro-electrochemical technique has been limited to apply to electrochemical systems with high wetting properties such as an acidic solution and low grade stainless steels(Type 316L). By loading negative pressure to a droplet, control of droplet size, and use of hydrophobic gasket, the cell is modified to be allowed to use for electrochemical systems with high wetting properties. For giving the reliability of new cell, studies on local corrosion were conducted for three different systems-an acidic chloride solution and high chromium ferritic stainless steel, the other acidic chloride solution and type 316, and a neutral chloride solution and type 316. stainless steel. Firstly, the modified micro-droplet cell allows the anodic polarization curves in an acidic chloride solution to show the fact that the local corrosion of high chromium stainless steel near the $\alpha/\sigma$ interface is due to the Cr depleted zone. Secondly, the local anodic polarization test of type 316 L in the other acidic chloride solution can be successfully conducted in the cell. Furthermore, the local polarization curves help elucidating the corrosion of type 316 with $\delta-ferrite$ phase. Finally, the polarization curves of type 316 L in a neutral chloride solution indicates that the factor affecting the pitting corrosion resistance was inclusions rather than $\delta-ferrite$.

Effect of the Heat Treatment on the Mechanical Property and Corrosion Resistance of CU - 7Al - 2.5Si Alloy (Cu-7Al-2.5Si 합금의 기계적 및 내식특성에 미치는 열처리 효과)

  • Lee, Syung-Yul;Won, Jong-Pil;Park, Dong-Hyun;Moon, Kyung-Man;Lee, Myeong-Hoon;Jeong, Jin-A;Baek, Tae-Sil
    • Corrosion Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.28-35
    • /
    • 2014
  • Recently, the fuel oil of diesel engines of marine ships has been increasingly changed to heavy oil of low quality as the oil price is getting higher and higher. Therefore, the spiral gear attached at the motor of the oil purifier which plays an important role to purify the heavy oil is also easy to expose at severe environmental condition due to the purification of the heavy oil in higher temperature. Thus, the material of the spiral gear requires a better mechanical strength, wear and corrosion resistance. In this study, the heat treatment(tempering) with various holding time at temperature of $500^{\circ}C$ was carried out to the alloy of Cu-7Al-2.5Si as centrifugal casting, and the properties of both hardness and corrosion resistance with and without heat treatment were investigated with observation of the microstructure and with electrochemical methods, such as measurement of corrosion potential, cathodic and anodic polarization curves, cyclic voltammogram, and a.c. impedance. in natural seawater solution. The ${\alpha}$, ${\beta}^{\prime}$ and ${\gamma}_2$ phases were observed in the material in spite of no heat treatment due to quenching effect of a spin mold. However, their phases, that is, ${\beta}^{\prime}$ and ${\gamma}_2$ phases decreased gradually with increasing the holding time at a constant temperature of $500^{\circ}C$. The hardness more or less decreased with heat treatment, however its corrosion resistance was improved with the heat treatment. Furthermore, the longer holding time, the better corrosion resistance. In addition, when the holding time was 48hrs, its corrosion current density showed the lowest value. The pattern of corroded surface was nearly similar to that of the pitting corrosion, and this morphology was greatly observed in the case of no heat treatment. It is considered that ${\gamma}_2$ phase at the grain boundary was corroded preferentially as an anode. However, the pattern of general corrosion exhibited increasingly due to decreasing the ${\gamma}_2$ phase with heat treatment. Consequently, it is suggested that the corrosion resistance of Cu-7Al-2.5Si alloy can be improved with the heat treatment as a holding time for 48 hrs at $500^{\circ}C$.

A case of Pulmonary Veno-occlusive Disease (폐정맥 패쇄에 의한 폐고혈압증 1예)

  • Cho, Jae-Youn;Lee, Sang-Youb;Lee, Sang-Hwa;Park, Sang-Myeon;Suh, Jeong-Kyung;Shim, Jae-Jeong;In, Kwang-Ho;Kang, Kyung-Ho;Yoo, Se-Hwa;Kim, Kwang-Taek
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.274-279
    • /
    • 1996
  • Pulmonary veno-occlusive disease is a rare cause of pulmonary hypertension in which the primary abnormality is obliterative obstruction of pulmonary veins, especially venules. Clinicaly, we should suspect this disease in the case of congestive cardiac failure with pulmonary hypertension, chronic interstitial pulmonary edema, and normal or elevated wedge pressure on cardiac catheterization. We experience a case of pulmonary hypertension due to pulmonary veno-occlusive disease. A 55-years -old woman developed progressive dry cough and dyspnea for 3 months. Physical examination showed normal heart sounds, diffuse crackles in the whole lung fields. The liver was not palpable and pitting edema was absent. The diagnosis was made by chest HRCT, 2-D echocardiography, normal pulmonary capillary wedge pressure on cardiac catheterization, and confirmed by thoracoscopic lung biopsy. This patient was treated with vasodilator(calcium antagonist) and with mild symptomatic improvement. We reported a case of pulmonary veno-occlusive disease with review of literatures.

  • PDF

AN ELECTROCHEMICAL STUDY ON THE CORROSION RESISTANCE OF THE VARIOUS IMPLANT METALS (수종 임플랜트 금속의 내식성에 관한 전기화학적 연구)

  • Jeon Jin-Young;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.423-446
    • /
    • 1993
  • Titanium and its alloys are finding increasing use in medical devices and dental implants. The strong selling point of titanium is its resistance to the highly corrosive body fluids in which an implant must survive. This corrosion resistance is due to a tenacious passive oxide or film which exists on the metal's surface and renders it passive. Potentiodynamic polarization measurement is one of the most commonly used electro-chemical methods that have been applied to measure corrosion rates. And the potentiodynamic polarization test supplies detailed information such as open circuit, rupture, and passivation potential. Furthermore, it indicates the passive range and sensitivity to pitting corrosion. This study was designed to compare the corrosion resistance of the commonly used dental implant materials such as CP Ti, Ti-6A1-4V, Co-Cr-Mo alloy, and 316L stainless steel. And the effects of galvanic couples between titanium and the dental alloys were assessed for their useful-ness-as. materials for superstructure. The working electrode is the specimen , the reference electrode is a saturated calomel electrode (SCE), and the counter electrode is made of carbon. In $N_2-saturated$ 0.9% NaCl solutions, the potential scanning was performed starting from -800mV (SCE) and the scan rate was 1 mV/sec. At least three different polarization measurements were carried out for each material on separate specimen. The galvanic corrosion measurements were conducted in the zero-shunt ammeter with an implant supraconstruction surface ratio of 1:1. The contact current density was recorded over a 24-hour period. The results were as follows : 1. In potential-time curve, all specimens became increasingly more noble after immersion in the test solution and reached between -70mV and 50mV (SCE) respectively after 12 hours. 2. The Ti and Ti alloy in the saline solution were most resistant to corrosion. They showed the typical passive behavior which was exhibited over the entire experimental range. Therefore no breakdown potentials were observed. 3. Comparing the rupture potentials, Ti and Ti alloy had the high(:st value (because their break-down potentials were not observed in this study potential range ) followed by Co-Cr-Mo alloy and stainless steel (316L). So , the corrosion resistance of titanium was cecellent, Co-Cr-Mo alloy slightly inferior and stainless steel (316L) much less. 4. The contact current density sinks faster than any other galvanic couple in the case of Ti/gold alloy. 5. Ag-Pd alloy coupled with Ti yielded high current density in the early stage. Furthermore, Ti became anodic. 6. Ti/Ni-Cr alloy showed a relatively high galvanic current and a tendency to increase.

  • PDF

Anatomical Comparison of Compression, Opposite, and Lateral Woods in a Branch of Pinus parviflora S. et Z. (섬잣나무(Pinus parviflora S. et Z.) 지재의 압축이상재, 측면재, 대응재에 관한 해부학적 특성 비교)

  • Xu, Guang Zhu;Eom, Young Geun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.1 s.129
    • /
    • pp.38-47
    • /
    • 2005
  • Compression, lateral, and opposite woods in a branch of Pinus parviflora S. et Z. were described and compared in the qualitative anatomical aspects through light and scanning electron microscopy. Tracheid transition from earlywood to latewood in the compression wood appeared to be relatively more gradual than in the opposite or lateral wood. Growth ring width and proportion of latewood were thought to be greater in the compression wood than in the lateral or opposite wood. The latewood tracheids of compression wood in transverse surface were mostly round, differently from those of lateral and opposite woods with square to angular shapes. Also, intercellular spaces, helical cavities and checks, and slit-like pit apertures were observed only in the compression wood tracheids. Cross-field pitting in the compression wood appeared not to be used as diagnostic guide because of their severe alteration from normal fenestriform or window-like type to cupressoid to taxodioid types. In tangential surface, fusiform rays in the compression wood were wider but lower than those in the lateral wood or opposite wood. In conclusion, compression wood was different from lateral and opposite woods but lateral and opposite woods were almost identical in qualitative anatomical features.

Giant Magnetoresistance of Antiferromagnetic Cr-Al based Multilayer Spin-Valve with Anti-Corrosion and Thermal Stability (내열 내식용 Cr-Al반강자성계 스핀밸브막의 거대자기저항 효과)

  • 김병수;이성훈;이찬규
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.6
    • /
    • pp.362-368
    • /
    • 1998
  • The magnetic properties, thermal stability and anti-corrosion properties of $Cr_86Al_14$ spin valves multilayers were studied. It was found that the magnetic properties of $Cr_86Al_14$ spin valves depend on the thickness of antiferromagnetic, ferromagnetic and non-ferromagnetic layers. Exchange coupled field ($H_{ex}$) and magnetoresistance ratio (%) showed the largest value of 20 Oe, 2 % in $glass/Cr_{86}Al_{14}(600 $\AA$)/Ni_{81}Fe_{19}(50$\AA$)/Cu(40 $\AA$)/Ni_{81}Fe_{19}(40 $\AA$)$ spin valves. The $H_{ex}$ MR ratios (%) of CrAl and FeMn spin valves were decreased with increasing annealing temperatures and were lost at 150 $^{\circ}C$, 250 $^{\circ}C$ respectively. Based on these result, it was elucidated that CrAl is more thermally stable than FeMn. It was also shown that there was no change of $H_{ex}$ MR ratios in CrAl, while FeMn was changed and lost 15 days later in corrosion resistance test under 35 $^{\circ}C$, 90 % humidity condition. FeMn was found to be pitted and peeled off 15 days later by SEM micrographic analysis.

  • PDF

Comparison of Virus Elimination Methods for Disease-free Seedlings of the Apple Dwarfing Rootstock (사과 왜성대목 무독묘 생산을 위한 바이러스 제거 방법 비교)

  • Kwon, Young Hee;Lee, Joung Kwan;Kim, Hee Kyu;Kim, Kyung Ok;Park, Jae Seong;Huh, Yoon Sun;Yoon, Yeo Joong
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2019.04a
    • /
    • pp.54-54
    • /
    • 2019
  • Apple (Malus domestica) is one of the most economically important fruits in Korea. But virus infection has decreased sustainable production of apple and caused the serious problems such as yield loss and poor fruit quality. Virus or viroid infection including Apple chlorotic leaf spot virus (ACLSV), Apple stem pitting virus (ASPV), Apple stem grooving virus (ASGV), Apple mosaic virus (ApMV) and Apple scar skin viroid (ASSVd) has been also reported in Korea. In many cases, apple is infected with virus and viroid with no specific symptoms, the damage caused by the virus are unaware significantly. In our research, we tried to eliminate viruses in the rootstock for the disease-free seedlings of the apple dwarfing rootstock M.9 and M.26. The method of virus elimination was meristem culture, heat($37^{\circ}C$, 6weeks) treatment and chemistry($Ribavirin^{(R)}$) treatment. The analytical methods commonly used for the detection of virus is Enzyme-linked Immuno-Sorbent Assay(ELlSA) and Reverse Transcription-polymerase Chain Reaction(RT-PCR). RT-PCR method was more 30% sensitive than ELISA method. Efficiency of method eliminate virus appeared meristem method > heat treatment > chemistry treatment. The higher acquisition rate of disease-free seedlings is 30~40% on meristem treatment. In meristem treatment, the apple dwarfing rootstock M.9 gained infection ratio of ACLSV, ASPV and ASGV were 45%, 60% and 50% respectively. In the apple dwarfing rootstock M.26, infection ratio of ACLSV, ASPV and ASGV were 40%, 55%, 55%, respectively. Based on our results, it was found that most effective method of disease-free seedlings apple dwarfing rootstocks was by meristem treatment than heat method and chemistry treatment.

  • PDF

A Study on Titanium Miniscrew as Orthodontic Anchorage : An experimental investigation in dogs (성견에서 교정적 고정원으로서의 티타늄 미니스크류에 대한 연구)

  • Yoon, Byung-Soo;Choi, Byung-Ho;Lee, Won-You;Kim, Kyoung-Nam;Shim, Hyung-Bo;Park, Jin-Hyung
    • The korean journal of orthodontics
    • /
    • v.31 no.5 s.88
    • /
    • pp.517-523
    • /
    • 2001
  • Titanium miniscrews we being used increasingly as an anchorage for tooth movement, because they ate easy to place and to remove, increase the number of sites available, give minimum strain to patients regarding surgical procedures, and offer uneventful healing alter removal. The use of titanium miniscrews as an orthodontic anchorage has been reported in clinical case reports, but clinicians have experienced screw loosening when using such screws.' To our knowledge, there are no published reports evaluating the stability of miniscrews. Information about the length of miniscrews used in relation to the location is of some importance, as stability will vary depending on bone duality The purpose of this study was to evaluate a variety of Lengths of miniscrews (dimeter: 2mm) which were inserted in maxilla or mandible and to demonstrate in a dog model which miniscrew provides fundamental stability in the jaws. 10 mm long miniscrews in the maxilla and 8mm long: miniscrews in the mandible showed no clinical mobility and retained their position throughout an 8 weeks force (200g) application. The mucosal condition around the screws was healthy in cases in which miniserews were inserted in the alveolar bone between the roots and the head of the screws emerged into the attached gingiva. When the force application was terminated, radiographic analysis revealed neither rent resorption not periodontal pathology around the miniscrews that remained stable during the entire treatment period. This study suggests that if titanium miniscrews with adequate length are properly used depending on the location, they provide sufficient stability for orthodontic anchorage.

  • PDF