• Title/Summary/Keyword: Pitch Ratio

Search Result 527, Processing Time 0.023 seconds

Comparison of vowel lengths of articles and monosyllabic nouns in Korean EFL learners' noun phrase production in relation to their English proficiency (한국인 영어학습자의 명사구 발화에서 영어 능숙도에 따른 관사와 단음절 명사 모음 길이 비교)

  • Park, Woojim;Mo, Ranm;Rhee, Seok-Chae
    • Phonetics and Speech Sciences
    • /
    • v.12 no.3
    • /
    • pp.33-40
    • /
    • 2020
  • The purpose of this research was to find out the relation between Korean learners' English proficiency and the ratio of the length of the stressed vowel in a monosyllabic noun to that of the unstressed vowel in an article of the noun phrases (e.g., "a cup", "the bus", etcs.). Generally, the vowels in monosyllabic content words are phonetically more prominent than the ones in monosyllabic function words as the former have phrasal stress, making the vowels in content words longer in length, higher in pitch, and louder in amplitude. This study, based on the speech samples from Korean-Spoken English Corpus (K-SEC) and Rated Korean-Spoken English Corpus (Rated K-SEC), examined 879 English noun phrases, which are composed of an article and a monosyllabic noun, from sentences which are rated on 4 levels of proficiency. The lengths of the vowels in these 879 target NPs were measured and the ratio of the vowel lengths in nouns to those in articles was calculated. It turned out that the higher the proficiency level, the greater the mean ratio of the vowels in nouns to the vowels in articles, confirming the research's hypothesis. This research thus concluded that for the Korean English learners, the higher the English proficiency level, the better they could produce the stressed and unstressed vowels with more conspicuous length differences between them.

Fabrication Method of High-density and High-uniformity Solder Bump without Copper Cross-contamination in Si-LSI Laboratory (실리콘 실험실에 구리 오염을 방지 할 수 있는 고밀도/고균일의 Solder Bump 형성방법)

  • 김성진;주철원;박성수;백규하;이희태;송민규
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.4
    • /
    • pp.23-29
    • /
    • 2000
  • We demonstrate the fabrication method of high-density and high-quality solder bump solving a copper (Cu) cross-contamination in Si-LSI laboratory. The Cu cross-contamination is solved by separating solder-bump process by two steps. Former is via-formation process excluding Cu/Ti under ball metallurgy (UBM) layer sputtering in Si-LSI laboratory. Latter is electroplating process including Ti-adhesion and Cu-seed layers sputtering out of Si-LSI laboratory. Thick photoresist (PR) is achieved by a multiple coating method. After TiW/Al-electrode sputtering for electroplating and via formation in Si-LSI laboratory, Cu/Ti UBM layer is sputtered on sample. The Cu-seed layer on the PR is etched during Cu-electroplating with low-electroplating rate due to a difference in resistance of UBM layer between via bottom and PR. Therefore Cu-buffer layer can be electroplated selectively at the via bottom. After etching the Ti-adhesion layer on the PR, Sn/Pb solder layer with a composition of 60/40 is electroplated using a tin-lead electroplating bath with a metal stoichiometry of 60/40 (weight percent ratio). Scanning electron microscope image shows that the fabricated solder bump is high-uniformity and high-quality as well as symmetric mushroom shape. The solder bumps with even 40/60 $\mu\textrm{m}$ in diameter/pitch do not touch during electroplating and reflow procedures. The solder-bump process of high-uniformity and high-density with the Cu cross-contamination free in Si-LSI laboratory will be effective for electronic microwave application.

  • PDF

Analysis of Clinical and Radiographic Outcome of the Reconstructive Surgery for the Cavovarus Foot Deformity (요내반족 변형에 대한 재건수술의 임상적 및 방사선학적 결과 분석)

  • Jung, Hong-Geun;Park, Jae-Yong;Lee, Dong-Oh;Eom, Joon-Sang;Chung, Seung-Hee
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.2
    • /
    • pp.62-67
    • /
    • 2014
  • Purpose: Reconstructive surgeries for equinocavovarus foot deformities are quite variable, including hind-midfoot osteotomy or arthrodesis, soft tissue procedure, tendon transfers, etc. Comprehensive evaluation of the deformity and its etiology is mandatory for achievement of successful deformity correction. Few studies in this field have been reported. We report on the clinical and radiographic outcome of reconstruction for cavovarus foot deformities. Materials and Methods: The study is based on 16 feet with cavovarus foot deformities that underwent bony and soft tissue reconstructive surgery from 2004 to 2008. We evaluated the etiologies, varieties of surgical procedures performed, pain score, functional scores, and patient satisfaction and measured the radiographic parameters. Results: The average age at the time of surgery was 39.4 years old, with a male/female ratio of 9/4 and an average follow-up period of 23.9 months (range, 12~49 months). The etiologies of the cavovarus deformity were idiopathic 7 feet, residual poliomyelitis 5 feet, Charcot-Marie-Tooth disease 2 feet, and Guillain-Barre syndrome and hemiplegia due to cerebrovascular accident sequela 1 foot each. Lateral sliding calcaneal osteotomies were performed in 12 feet (75%), followed by Achilles tendon lengthening and plantar fascia release in 11 feet (69%), and first metatarsal dorsiflexion osteotomy/arthrodesis and tendon transfer in 10 feet (63%). Visual analogue scale pain score showed improvement, from an average of 4.2 to 0.5 points. American Orthopaedic Foot and Ankle Society ankle-hindfoot score showed significant improvement, from 47.8 to 90.0 points (p<0.05). All patients were satisfied. Ankle range of motion improved from $27.5^{\circ}$ to $46.7^{\circ}$. In radiographic measurements, calcaneal pitch angle improved from $19.1^{\circ}$ to $15.8^{\circ}$, Meary angle from $13.0^{\circ}$ to $9.3^{\circ}$, Hibb's angle from $44.3^{\circ}$ to $37.0^{\circ}$, and tibio-calcaneal axis angle from varus $17.5^{\circ}$ to varus $1.5^{\circ}$ Conclusion: We achieved successful correction of cavovarus foot deformities by performing appropriate comprehensive reconstructive procedures with improved functional, radiographic measures and high patient satisfaction.

Injection Laryngoplasty for The Treatment of Vocal Fold Scar, and Sulcus (성대구증 및 성대 반흔 환자에서 주사후두성형술의 효과)

  • Woo, Joo Hyun;Baek, Min Kwan;Kim, Dong Young;Park, Hyoung-Min;An, Sanghee;Moon, Kwang Ha;Cha, Heung Eog
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.27 no.1
    • /
    • pp.25-29
    • /
    • 2016
  • Background and Objectives : The clinical reports for the treatment of vocal fold scar and sulcus vocalis are limited, also there is no best one for the treatment of them. This study is to evaluate the effect of Injection laryngoplasty (IL) for the treatment of vocal fold scar and sulcus vocalis. Materials and Methods : from January 2013 to May 2015, the Nineteen patients who were diagnosed as vocal fold scar, sulcus and atrophy, and underwent IL, were engaged in this study. Clinical information and voice parameters were analyzed by retrospective chart review. Pre and post voice parameters were compared. Results : Subgroups of diagnosis were classified into sulcus vocalis for 12 patients, vocal fold scar for 5, and atrophy for 2. IL was performed under local anesthesia through cricothyroid membrane except one patient. Atesense$^{(R)}$, Radiessess$^{(R)}$, and Rofilan$^{(R)}$ were used as injected materials in 9, 9, and 1 patients respectively. Maximal phonation time (p=0.0124), dynamic range (p=0.0028), pitch range (p=0.0141), voice handicap index (p=0.028), glottal closure (p=0.0229), and mucosal wave (p=0.0132) had significant improvement for post-IL voice assessment than Pre-IL. While GRBAS, Mean flow rate, Jitter, Shimmer, Harmony to Noise ratio didn't have improvement. Conclusion : IL is a feasible option for the treatment of glottis incompetence with normally mobile vocal folds such as sulcus vocalis and vocal fold scar.

  • PDF

Experimental Study on Pressure Loss of Flow Parallel to Rod Bundle with Spacer Grid (지지격자가 있는 봉다발과 축방향으로 평행한 유동의 압력손실에 관한 실험적 연구)

  • Lee, Chi-Young;Shin, Chang-Hwan;Park, Ju-Yong;In, Wang-Kee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.7
    • /
    • pp.689-695
    • /
    • 2012
  • The friction factor in a rod bundle and the loss coefficient at a spacer grid were examined. As a test section, 25 smooth rods, 9.5 mm in diameter and 2000 mm in length, were prepared and installed in a $5{\times}5$ square array in a square channel. In this case, the P/D (Pitch-to-Diameter ratio) was 1.35. In this work, plain (i.e., no mixing vanes), split-vane, and hybrid-vane spacer grids were tested. In a bare rod bundle (i.e., no spacer grid), the measured friction factors were in good agreement with the previous correlations. Among the spacer grids tested, the hybrid-vane spacer grid presented the largest friction factor in the rod bundle and loss coefficient. This may be because of the flow pattern change induced by large relative plugging of the flow cross section and mixing vane geometry. At Re=$5{\times}10^5$, the predicted loss coefficients of plain, splitvane, and hybrid-vane spacer grids were approximately 0.79, 0.80, and 0.88, respectively.

Development of the Fixed Slab Analogy Device for the Measurement of Stress Intensity Factor (응력확대계수 측정용 고정 슬랩상사 장치의 개발)

  • 정진석;최선호;황재석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.1999-2010
    • /
    • 1992
  • The fixed slab analogy device which can measure stress intensity factors(S.I.F) experimentally by slab analogy theory is developed in this paper. The margin of errors resulted from the new testing apparatus are between 0.02% and 8.25%. Therefore, it is assured that this one can be effectively used for the more accurate measurement of S.I.F.( $k_{I}$, $k_{I I}$) than conventional apparatus. The pitch of master grating used in this experiment is 0.1mm It is known that the ratio of the distance from crack tip to the crack length on obtaining the accurate stress intensity factor is between 0.4 and 0.7. The optimum curvature radius of slab is about 125mm. The thickness of slab(plate) used in the fixed slab analogy device is 0.05mm(P.V.C. ; E = 64 MN/ $m^{2}$, .nu.=0.38), which is proved to be suitable for the test. The optimum material for the frame(slab`s external boundary) is a alloy tool steel(SKS 5) plate and its thickness is 1mm. In this research, the rigid cracks are directly bonded to the slab surface by cyanoacrylate adhesive for the easiness of slab making and conformity to the practical crack figure. The material of rigid crack is thin steel plate. It is expected that the developed method can be used effectively for the analysis of $k_{I}$ and $k_{I I}$ of arbitrary shaped or distributed cracks.cks.

A Study on the Design of Horizontal Traverse Units in an Automatic Object Changer Unit to Establish a Flexible Production System (Part 2) (유연생산 시스템 구축을 위한 공작물 자동교환 유닛의 수평 이송 기구 설계에 관한 연구(파트 2))

  • Park, Hoo-Myung;Sung, Jae-Kyung;Lee, Yong-Joong;Ha, Man-Kyung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.2
    • /
    • pp.52-59
    • /
    • 2008
  • The objective of this study is to develop an automatic object changer unit to improve processing problems existed in the conventional horizontal machining center. To achieve this goal, this study designed a horizontal transfer as the second project continued to the first project that designed a upward and downward traverse unit. A horizontal traverse unit shows a symmetric structure and consists of frame, which consists of four unit tools, motor and reducer, which are fixed at a frame, operation unit with pinions, first traverse unit, and second traverse unit. Constraint conditions based on the operation mechanism with these elements were configured and obtained following results after modeling a model for a traverse motor. In the kinematic expression of sliding motion with one degree of freedom, the sliding motion is constrained. Also, the rack 3 installed at a frame is used to configure possible kinematic constraint conditions of the rack 2 according to the rolling motion of the pinion 2 in the first traverse unit. In addition, the moment of inertia that is a type of kinetic energy in a converted horizontal traverse unit in the side of the reducer can be applied to introduce the moment of inertia of a converted horizontal traverse unit in the side of the reducer by using the sum of kinetic energy in the rack and pinion, which is a part of the horizontal traverse unit. Also, the equation of motion of the converted upward and downward traverse unit in the side of the motor using the equation of motion of the motor. Furthermore, the horizontal traverse unit predetermines the mass of the first and second traverse unit and applied load including the radius and reduction ratio of the pitch circle in the pinion 1 and applied load to the rack 2. Then, a proper motor can be determined using several parameters in the upward and downward traverse unit in order to verify such predetermined specifications. In future studies later this study, a simulation that verifies the results of the previous two stages of studies using a finite element method.

  • PDF

Examination of Forced Convection Heat Transfer Performance of a Twist-Vane Spacer Grid for a Dual-Cooled Annular Fuel Assembly (이중냉각 환형핵연료 집합체를 위한 비틀림 혼합날개 지지격자의 강제대류열전달 성능 검토)

  • Lee, Chi Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.1
    • /
    • pp.53-62
    • /
    • 2017
  • The forced convection heat transfer performance of a twist-vane spacer grid for a dual-cooled annular fuel assembly was examined experimentally. The twist-vane spacer grid was uniquely designed to enhance mixing inside subchannels and mixing between adjacent subchannels. For testing, a $4{\times}4$ square-arrayed rod bundle with narrow gaps between rods was prepared as the dual-cooled annular fuel assembly to be simulated. The pitch-to-rod diameter ratio of simulated dual-cooled annular fuel assembly was 1.08. The experiments were performed under the following conditions: axial bulk velocity, 1.5 m/s and heat flux, $26kW/m^2$. With regard to the circumferential temperature distribution, the lowest rod-wall temperatures upstream and downstream were measured at the subchannel center and the position toward the tip of twist-vane, respectively. With regard to the axial temperature distribution, behind the twist-vane spacer grid, the rod-wall temperature decreased drastically, and the Nusselt number was enhanced by up to 56 %. The present measured data indicate that the twist-vane spacer grid can effectively improve the forced convection heat transfer in the dual-cooled annular fuel assembly with narrow gaps.

Effects of low-dose topiramate on language function in children with migraine

  • Han, Seung-A;Yang, Eu Jeen;Kong, Younghwa;Joo, Chan-Uhng;Kim, Sun Jun
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.7
    • /
    • pp.227-231
    • /
    • 2017
  • Purpose: This study aimed to verify the safety of low-dose topiramate on language development in pediatric patients with migraine. Methods: Thirty newly diagnosed pediatric patients with migraine who needed topiramate were enrolled and assessed twice with standard language tests, including the Test of Language Problem Solving Abilities (TOPs), Receptive and Expressive Vocabulary Test, Urimal Test of Articulation and Phonology, and computerized speech laboratory analysis. Data were collected before treatment, and topiramate as monotherapy was sustained for at least 3 months. The mean follow-up period was $4.3{\pm}2.7months$. The mean topiramate dosage was 0.9 mg/kg/day. Results: The patient's mean age was $144.1{\pm}42.3months$ (male-to-female ratio, 9:21). The values of all the language parameters of the TOPs were not changed significantly after the topiramate treatment as follows: Determine cause, from $15.0{\pm}4.4$ to $15.4{\pm}4.8$ (P>0.05); making inference, from $17.6{\pm}5.6$ to $17.5{\pm}6.6$ (P>0.05); predicting, from $11.5{\pm}4.5$ to $12.3{\pm}4.0$ (P>0.05); and total TOPs score, from $44.1{\pm}13.4$ to $45.3{\pm}13.6$ (P>0.05). The total mean length of utterance in words during the test decreased from $44.1{\pm}13.4$ to $45.3{\pm}13.6$ (P<0.05). The Receptive and Expressive Vocabulary Test results decreased from $97.7{\pm}22.1$ to $96.3{\pm}19.9months$, and from $81.8{\pm}23.4$ to $82.3{\pm}25.4months$, respectively (P>0.05). In the articulation and phonology validation in both groups, speech pitch and energy were not significant, and all the vowel test results showed no other significant values. Conclusion: No significant difference was found in the language-speaking ability between the patients; however, the number of vocabularies used decreased. Therefore, topiramate should be used cautiously for children with migraine.

Flow Resistance of Vertical Rib Sidewall in Open Channel (개수로 측벽 세로돌출줄눈의 흐름저항)

  • Park, Sang Deog;Ji, Min Gyu;Nam, A Reum;Woo, Tae Young;Shin, Seung Sook
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.9
    • /
    • pp.947-956
    • /
    • 2013
  • Most of flood protection walls built on the impingement in mountain rivers have been made of concrete. It may cause flood disasters because the smooth wall surface could increase flow velocity. In this study the hydraulic experiments was carried out to evaluate the effect of one side wall with rectangular vertical ribs on flow resistance in open channel. The ratio of the pitch between vertical ribs to its depth, ${\lambda}_{nv}$, was designed so that it include the so-called d type and k type roughness. The range of Froude number, $F_r$, based on hydraulic radius is 0.81~1.12. Flow resistance in the open channel with a rib sidewall depends on the interval length of each ribs and the flow discharge. Maximum flow resistance occurred when ${\lambda}_{nv}$ is 9. In the d type roughness which ${\lambda}_{nv}$ is less than 3, the flow resistance decreases with increase of flow discharge. In the k type roughness which ${\lambda}_{nv}$ is greater than 3, the flow resistance increases with increase of flow discharge. The increments of flow resistance are especially great when ${\lambda}_{nv}$ are 9 and 12. The resistance due to vertical rib is mostly by the shape resistance and the vertical rib on one sidewall of open channel affects on the flow resistance so that the equivalent roughness heights of vertical rib may occur in scale of flow depth. Therefore the vertical ribs may be used to reduce the flow velocity and to move the location of maximum flow velocity from the rib sidewall to the centerward in a cross section of channels.