• Title/Summary/Keyword: Piston position

Search Result 101, Processing Time 0.015 seconds

Force Fighting Suppressive Technique of Dual Redundant Asymmetric Tandem Electro-Hydrostatic Actuator for Aircraft (항공기용 이중화 비대칭형 직렬 전기-정유압 구동기의 Force Fighting 억제 기법)

  • Song, Woo Keun;Kim, Sang Seok;Choi, Jeong Seok;Lee, JungUn;Lee, Jong Cheol;Lee, Jun won;Choi, Jong Yoon
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.5
    • /
    • pp.62-69
    • /
    • 2022
  • EHA (Electro-Hydrostatic Actuator) is more energy efficiency than a centralized hydraulic system. In particular, the EHA used for aircraft has a redundant design in preparation for failure scenario. Also, due to the aircraft's internal space limitation, the actuator's length must be optimized. Therefore, a series configuration of double rod and single rod cylinder is advantageous. However, due to the asymmetry of the cross-sectional area of the piston, the force fighting phenomenon between the two cylinder areas occurs during redundant operation with a general control system. In this paper, the force fighting phenomenon of redundant EHA was simulated. A controller with load compensation and a force control-based position controller as a method to suppress its stimulation