Fracture Behavior of Welded Pipes with Local Wall Thinning (감육을 가지는 배관 용접부의 파괴거동)

  • Ahn, Seok-Hwan;Nam, Ki-Woo;Jeong, Jeong-Hwan;Kim, Yong-Un
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.90-95
    • /
    • 2003
  • Fracture behaviors of pipes with local wall thinning are very important for the integrity of nuclear power plant. In pipes of energy plants, sometimes, the local wall thinning may result from severe erosion-corrosion (E/C) damage. However, the effects of local wall thinning on strength and fracture behaviors of piping system were not well studied. In this paper, the monotonic bending tests were performed of full-scale welded and unwelded carbon steel pipes with local wall thinning. A monotonic bending load was applied to straight pipe specimens by four-point loading at ambient temperature without internal pressure. The observed failure modes were divided into four types; ovalization, crack initiation/growth after ovalization, local buckling and crack initiation/growth after local buckling. Also, the strengths of welded and unwelded piping system with local wall thinning were evaluated.

  • PDF

The Effect of a Tip Mass on Dynamic Stability of Pipes on Elastic Foundations (탄성기초 위에 놓인 파이프의 동적 안정성에 미치는 말단 질량의 영향)

  • 류봉조;김건희
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • 제14권11호
    • /
    • pp.1115-1122
    • /
    • 2004
  • The paper discussed the effect of a tip mass on the stability of pipes on elastic foundations. Governing equations of motion are derived by extended Hamilton's principle, and the numerical scheme using finite element method is applied to obtain the discretized equations. With or without internal damping, the critical flow velocities of the pipes are investigated according to the variation of elastic foundation parameters and tip mass ratios. Also. the relationship between the eigenvalue branches and the corresponding flutter modes of the cantilevered pipes with a tip mass on the elastic foundations is fully investigated.

Attenuation Characteristics of the Buried Steel Water Pipes (지하매설 유체함입 강파이프의 감쇠특성 규명)

  • Park, K.J.;Kang, W.S.;Kim, Y.G.
    • Journal of Power System Engineering
    • /
    • 제13권1호
    • /
    • pp.39-45
    • /
    • 2009
  • The attenuation of the fundamental non-torsional modes that propagate down buried steel water pipes has been studied. The mode shapes, mode attenuation due to leakage into the surrounding medium and the scattering of the modes as they interact with pipe joints and fittings have been investigated. In the low frequency region the mode predicted to dominate over significant propagation distances approximates a plane wave in the water within pipe. The established acoustic technique used to locate leaks in buried steel water pipes assumes that leak noise propagates as a single non-dispersive mode at a velocity related to the low frequency asymptote of this water borne mode.

  • PDF

Structural Behavior of Glass-Fiber Reinforced Plastic Composite Pipes (유리섬유 강화플라스틱 복합관의 구조적 특성)

  • 연규석;김남길;조규우;김동준;최종윤;백종만
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.822-827
    • /
    • 2003
  • This study was performed to evaluate the internal and external factors affecting external strength of the 3-layer polymer composite pipes made of polymer mortar and fiber-glass reinforced plastic. Twenty four sandwich type 3-layer polymer composite pipes were made of polymer mortar and fiber-glass reinforced plastic by centrifugal method. The objective of this study was to evaluate the effects the of polymer mortar thickness for and core fiber-glass contents per unit area on external strength of 3-layer polymer composite pipes. For the more economical and practical design of 3-layer polymer composite pipe, further study should be done for the various polymer mortar, fiber-glass and different ratio of the inside/outside FRP thickness.

  • PDF

Complex Leakage Probability Evaluation of Nuclear Pipes by Fatigue and Stress Corrosion Cracking (피로 및 응력부식균열에 의한 원전 배관의 복합누설확률 평가)

  • Kim, Seung Hyun;Goni, Nasimul;Chang, Yoon-Suk;Jang, Changheui
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • 제11권2호
    • /
    • pp.25-30
    • /
    • 2015
  • In the present study, complex leakage probabilities of nuclear pipes due to fatigue and stress corrosion cracking are evaluated by using the PINTIN(Piping INTegrity INner flaws) that is developed based on the existing PRAISE(Piping Reliability Analysis Including Seismic Events) program. With regard to the aging and crack instability, small leak and big leak probabilities are calculated for several pipes in a reactor coolant system of domestic nuclear plant. Moreover, sensitivity analysis is also performed to find out the effect of parameters for the leakage of pipes, which shows the coolant temperature is the most influencing parameter.

Analysis on Shielding Effectiveness of Electromagnetic Wave in Fire Pipes (물이 채워진 소화 배관의 전파 차폐도 해석)

  • Kim, Yoon-Jeung
    • Fire Science and Engineering
    • /
    • 제30권4호
    • /
    • pp.94-102
    • /
    • 2016
  • When establishing shielding facilities for EMP protection, WBC effect is used to protect fire pipes and honeycomb cells are inserted into the fire pipes to improve the shielding effectiveness. At this point, the smaller unit cell of honeycombs becomes, the more likely it interrupts the flow of water, which ends up clogging the fire pipes with sediment. To prevent this phenomenon, I would suggest a design method due to the pilarization loss of water molecules that contributes to increasing the size of honeycomb cells and remaining thin-walled sufficient for required shielding effectiveness.

A study on corrosion mechanism of water steel pipes using SEM (SEM을 이용한 상수도 금속관 부식거동에 관한 연구)

  • 황상용
    • Journal of environmental and Sanitary engineering
    • /
    • 제17권4호
    • /
    • pp.53-60
    • /
    • 2002
  • This experiment was performed to investigate the characteristics of corrosion mechanism of water steel pipes using SEM(Scanning Electron Microscope) from March 1. 2002 to November 30. The characteristics shown in these results can be summarized as the following: 1. When I investigated to the characteristics of iron pipes and zinc pipes using a SEM, I could be found that there was a distintion in interface between an iron pipe and the scale, and that a zinc pipe wears a dark color. 2. I find much rate of $Fe_2O_3$ and a little rate of FeS as corrosion products, but I hardly find $FeCO_3$without carbon. 3 It was found that the oxide corrosion rate was 0.2~0.3mm/year. And then A-1 was 0.323mm/year that was very high.

A study on the performance prediction of 4 cycle 4 cylinder S.I. engine considering the unsteady flow in the intake and exhaust pipes (흡배기 관내의 비정상 유동을 고려한 4사이클, 4기통 전기.점화 기관의 성능 예측에 관한 연구)

  • 박성서;김응서
    • Journal of the korean Society of Automotive Engineers
    • /
    • 제13권6호
    • /
    • pp.72-81
    • /
    • 1991
  • In this study, the analytic investigation of the unsteady flow in the intake and exhaust pipes has been carried out using the method of characteristics in one direction to predict volumetric efficiency. Based on the calculated volumetric efficiency, three zone predictive analysis using Wiebe function was applied to predict the engine performance and the results were compared with experiment. Mixture in the cylinder is subdivided into three zones during combustion process in this analysis; adiabatic core zone, thermal boundary layer zone and unburned zone. In each zone, pressure, temperature and gas composition have been calculated. In conclusion, it is possible to take account of the intake and exhaust pipe tuning effect in predicting the engine performance, by the analytic solution of the unsteady flow in the pipes, and comparison of prediction with experimental results shows a good agreement on the pressure variation in the intake and exhaust pipes which has a direct influence on the volumetric efficiency and performance of the engine.

  • PDF

Experiment on the Improvement in Corrosion Resistance of Galvanized Steel Pipes for Plastic Greenhouse (플라스틱 온실용 아연도강관의 내식성 증대방법)

  • Nam, Sang-Woon;Noh, Sang-Mok
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.175-180
    • /
    • 2005
  • Experiments on the improvement in durability of pipe framework for plastic greenhouse were carried out. Effect of protection treatment such as primer and paint coating for new pipes and old rusted ones were evaluated by change of rusty degree and yield strength. The experiments have been conducted during five years until now but it was too short to find the clear differences. However, there was a little improvement in durability of greenhouse pipes by painting after removal of rust. And also component and corrosion characteristics of pipes being used in greenhouses were analyzed, and several countermeasures for protection from corrosion were reviewed.

  • PDF

Analysis and Improvement for Performance of the Muffler of a Tracter (트랙터 소음기의 성능해석 및 개선에 관한 연구)

  • 이규태;도중석;오재응
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • 제6권4호
    • /
    • pp.151-159
    • /
    • 1998
  • The heavy equipment such as tracter has been studied to improve rather the performance of engine than comfort. The mufflers of tracters have various specifications according to their uses. The exact analysis of various mufflers is needed to reduce the level of exhaust moise, a major noise source of engine, to improve the ride quality of tracter. In this study, a software based on Green's function is developed to predict the performance of sound transmission loss for a muffler according to the locations of inlet/outlet pipes. The locations of inlet and outlet pipes can be fixed at different position individually. The conventional muffler has the locations of inlet/outlet pipes on the direction of longitudinal axes. On other hand, the inlet and outlet pipes may be located at the circumferential surface of a test muffler such as one of tracter. The software is verified by analysis and experiment on current muffler of tracter and the improvement technique is proposed to reduce the level of exhaust noise.

  • PDF