• 제목/요약/키워드: Pipeline corrosion

검색결과 200건 처리시간 0.021초

Flow-accelerated corrosion assessment for SA106 and SA335 pipes with elbows and welds

  • Kim, Dong-Jin;Kim, Sung-Woo;Lee, Jong Yeon;Kim, Kyung Mo;Oh, Se Beom;Lee, Gyeong Geun;Kim, Jongbeom;Hwang, Seong-Sik;Choi, Min Jae;Lim, Yun Soo;Cho, Sung Hwan;Kim, Hong Pyo
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3003-3011
    • /
    • 2021
  • A FAC (flow-accelerated corrosion) test was performed for a straight pipe composed of the SA335 Gr P22 and SA106 Gr B (SA106-SA335-SA106) types of steel with welds as a function of the flow rate in the range of 7-12 m/s at 150 ℃ and with DO < 5 ppb at pH levels ranging from 7 to 9.5 up to a cumulative test time of 7200 h using the FAC demonstration test facility. Afterward, the experimental pipe was examined destructively to investigate opposite effects as well as entrance effects. In addition, the FAC rate obtained using a pipe specimen with a 50 mm inner diameter was compared with the rate obtained from a rotating cylindrical electrode. The effects of the complicated fluid flows at the elbow and orifice of the pipeline were also evaluated using another test section designed to examine the independent effects of the orifice and the elbow depending on the distance and the combined effects on orifice and elbow. The tests were performed under the following conditions: 130-150 ℃, DO < 5 ppb, pH 7 and a flow rate of 3 m/s. The FAC rate was determined using the thickness change obtained from commercial room-temperature ultrasonic testing (UT).

원격장 와전류 배관 탐상 시스템 개발 (Development of Remote Field Eddy Current Pipeline Inspection System)

  • 정진오;이재경;김형진
    • 비파괴검사학회지
    • /
    • 제21권5호
    • /
    • pp.556-560
    • /
    • 2001
  • 배관의 관벽투과 특성을 지닌 원격장 와전류 비파괴 검사법은 열교환기 세관 검사에서부터 천연가스 수송관에 이르기까지 다양한 형태의 배관과 결함을 대상으로 적용 연구가 진행되고 있다. 공칭 외경 100mm의 주철관은 주로 상수도 관로의 배수관으로 활용되고 있는데, 차량 진동과 부식에 의한 결함의 생성으로 정수의 누수 문제를 일으킨다. 그러나, 탐상 경제성 및 효용성 문제로 관내 검사장치 투입과 같은 직접적인 검사 방법의 수행이 제한되어 왔다. 원격장 와전류 방법은 시스템 구성이 용이하고 내 외부 부식 결함에 대한 정량적인 평가가 가능하기 때문에 경제성 있는 장치 개발이 가능하다. 본 연구에서는 원격장 와전류 기술을 이용하여 상수도 관망의 특성을 고려한 매설 배관 검사시스템 개발을 수행하였다. 세부적으로는 관내 투입 원격장 와전류 검사의 기구부 설계 및 제작, 원격장 와전류 신호의 획득 및 처리 프로그램 개발, 그리고 개발 장치의 운용 방법 및 절차 검토 등으로 되어 있다.

  • PDF

상수도용 유리섬유복합관의 구조적 거동특성 및 안전성 평가 (Characteristics of Structural Behavior and Safety Estimation of Water Supply GFRP Pipe)

  • 이보베;이승식;주형중;윤순종
    • Composites Research
    • /
    • 제22권3호
    • /
    • pp.1-8
    • /
    • 2009
  • 이 논문에서는 강수도관에 사용되는 GFRP관의 구조적 거동에 대한 실험적, 이론적 연구의 결과를 제시하였으며, 관의 단면은 두개의 CFRP층과 그 층 사이의 폴리머 모르타르 층으로 구성되어 있다. GFRP는 경량성, 부식저항성, 관의 내부 표면조도 향상, 유연성 등이 뛰어나기 때문에 강수 계통의 관으로써 시용이 계속적으로 증가되고 있는 추세이다. 그러므로 더욱 최적화된 구조설계법이 개발되어야 한다. 이 연구에서 CFRF관의 하중-원주방향변위에 대한 특성을 이론적, 해석적으로 조사 하였으며 추가적으로 원강성시험을 하였다. 시험결과를 이론적, 해석적 연구결과와 비교하였으며, 원주방향의 변위가 5% 이내에서는 결과들이 서로 잘 일치하였다. 결과적으로 상수도 계통에 사용되는 CFRP관은 업계의 요구조건을 충분히 만족함을 알 수 있었다.

급수가열기 동체 감육 현상 규명을 위한 유동해석 연구 (A Study on the Fluid Mixing Analysis for Proving Shell Wall Thinning of a Feedwater Heater)

  • 신민호;황경모;김경훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2017-2022
    • /
    • 2004
  • There are multistage preheaters in the power generation plan to improve the thermal efficiency of the plant and to prevent the components from the thermal shock. The energy source of these heaters comes from the extracted two phase fluid of working system. These two-phase fluid can cause the so-called Flow Accelerated Corrosion(FAC) in the extracting piping and the bubble plate of the heater for example, in case of point Beach Nuclear Power Plant and in the Wolsung Nuclear Power Plant. The FAC is due to the mass transport of the thin oxide layer by the convection. FAC is dependent on many parameters such as the operation temperature, void fraction, the fluid velocity and pH of fluid and so on. Therefore, in this paper velocity was calculated by FLUENT code in order to find out the root cause of the wall thinning of the feedwater heaters. It also includeed in the fluid mixing analysis model are around the number 5A feedwater heater shell including the extraction pipeline. To identify the relation between the local velocities and wall thinning, the local velocities according to the analysis results were compared with distribution of the shell wall thicknes by ultrasonic test.

  • PDF

급수가열기 동체 감육 현상 규명을 위한 유동해석 연구 (A Study on the Fluid Mixing Analysis for Proving Shell Wall Thinning of a Feedwater Heater)

  • 김경훈;황경모;김상녕
    • 한국분무공학회지
    • /
    • 제9권4호
    • /
    • pp.24-30
    • /
    • 2004
  • Feedwater flowing tube side of number 5 high pressure feedwatrr heaters was heated by extracting steam from high pressure turbine and draining water from moisture separators and number 6 high pressure feedwater heaters and supplied into steam generators. Because the extracting steam from the high pressure turbine is two phase fluid of high temperature, high pressure, and high speed and flows to inverse direction after impinging to impingement baffle. the shell wall of the number 5 high pressure feedwater heater may be affected by flow accelerated corrosion. On May 14, 1999, Point Beach Nuclear Plant (PBNP) with operating at full power experienced a steam leak from rupture of shell side of number 4B feedwater heater. Also, d domestic nuclear power plant experienced a severe wall thinning of shell side of number 5A and 5B feedwater heaters. This paper describes the fluid mixing analysis study using PHOENICS code in order to get at the root of the shell wall thinning of the feedwater heaters. The sections included in the fluid mixing analysis model are around the number 5h feedwater heater shell including the extracting pipeline. To identify the relation between the local velocities and wall thinning. the local velocities according to the analysis results were compared with the distribution of the shell wall thickness by ultrasonic test.

  • PDF

수질안정화 약품 주입에 따른 상수도관 내부 부식제어 특성 연구 (Corrosion control technique for pipeline system through injecting water stabilizer)

  • 황병기;우달식
    • 한국산학기술학회논문지
    • /
    • 제12권1호
    • /
    • pp.545-551
    • /
    • 2011
  • 최근 고품질의 수돗물에 대한 소비자의 요구가 상승함에 따라 상수도 배급수관의 내부 부식에 의한 수질악화 및 부식제어 연구에 대한 관심이 높아지고 있다. 이에 따라 노후 관 교체 사업을 대신하여 수질 관리를 위한 부식 제어 수단을 강구하지 않고서는 근본적인 문제 해결이 이루어질 수 없는 실정이다. 본 연구에서는 수질안정화 약품 주입에 의한 상수도관 내부 부식제어 효율을 평가하기 위해 Pilot Plant 실험을 실시하였으며, 부식성제어 효율은 물의 부식성을 나타내는 LSI(Langelier Saturation Index)값에 의해 평가되었다. 실험결과, Pilot Plant에 의해 제조된 반응수는 수질안정화 약품인 액상소석회($Ca(OH)_2$, liquid lime)의 주입으로 부식성이 개선되어 철 용출이 억제되는 효과가 확인되었다. 강관과 동관을 절단하여 제작한 시편의 부식도 측정을 통해 각각 35.4, 44.5%의 부식제어 효과가 있음을 확인하였고 수질안정화 약품이 주입된 Sample관이 더 두터운 부식 생성물 층을 갖고 있는 것으로 밝혀졌으며, 결과적으로 수질안정화 약품을 투입한 배관이 부식 방지 측면에서 안정한 수질을 갖고 있음을 알 수 있었다.

수치해석 기법을 활용한 FAC 예측 프로그램 보완 (Supplementation of Flow Accelerated Corrosion Prediction Program Using Numerical Analysis Technique)

  • 황경모;진태은;박원;오동훈
    • 대한기계학회논문집B
    • /
    • 제34권4호
    • /
    • pp.437-442
    • /
    • 2010
  • 고온, 고압의 유체가 흐르는 탄소강 배관에서는 유동가속부식으로 인한 배관감육 현상이 발생할 수 있다. 화력 및 원자력발전소에서 유동가속부식으로 인한 배관 손상시 고비용의 보수와 발전 정지를 유발할 뿐 아니라 발전소 신뢰도 및 안전성에 영향을 미칠 수도 있다. CHECWORKS 프로그램은 국내 발전소에서 유동가속부식에 의한 배관 손상을 예방하기 위하여 배관 두께검사 데이터를 평가하고 검사 계획을 수립하는데 이용되어 왔다. 그러나 상기 프로그램은 원전 2차측 배관 모두를 데이터베이스화한 후에 배관라인 그룹별로 유동가속부식 손상을 예측하기 때문에 국부적으로 감육에 민감한 부위를 찾는데 어려움이 있다. 본 논문에서는 CHECWORKS 프로그램을 이용하여 해석을 수행하고 수치해석을 통하여 검증할 수 있는 방법론을 기술하였다. 또한 국내 원전 2개의 배관 라인그룹에 대하여 CHECWORKS 프로그램을 이용한 유동가속부식 민감 부위를 FLUENT를 이용한 수치해석 결과와 비교하였다.

모형 재이용관을 이용한 하수재이용수의 부식 및 수질영향 연구 (Characteristics of Corrosion and Water Quality in Simulated Reclaimed Water Distribution Pipelines)

  • 강성원;이재영;이현동;김지은;곽필재
    • 대한환경공학회지
    • /
    • 제34권7호
    • /
    • pp.473-479
    • /
    • 2012
  • 하수재이용은 부족한 수자원 문제를 해결할 수 있는 대표적인 대안으로 주목을 받고 있다. 본 연구에서는 하수재이용수의 공급시 관망내에서 일어날 수 있는 관의 부식과 수질변화에 대한 연구를 모형관망을 이용하여 수행하였다. 관 재질은 아연도강관(GSP), 주철관(CIP), 스테인레스강관(STSP), PVC관(PVCP)을 이용하였고, 하수재이용수와 수돗물을 각각 공급하여 비교 및 평가하였다. 하수재이용수를 모형관망에 공급하는 루프테스트를 수행한 결과, 관 재질별 시편의 무게 감소량은 CIP > GSP > STSP ${\approx}$ PVCP의 순으로 나타났다. 또한, 하수재이용수는 수돗물과 비교하여 부식속도가 높게 나타났는데, CIP의 경우, 하수재이용수의 초기 부식속도가 3.511 mdd, 수돗물은 2.064 mdd를 나타내었고, 90일간의 부식속도는 하수재이용수 0.833 mdd, 수돗물 0.294 mdd를 나타내었다. 또한, GSP도 하수재이용수의 초기 부식속도가 2.703 mdd, 수돗물은 2.499 mdd를 나타내었고, 90일간의 부식속도는 하수재이용수 0.349, 수돗물 0.248 mdd로 CIP에서 나타난 경향과 유사하였으며, 시간이 지남에 따라 부식속도가 감소하는 경향을 나타내었다. 루프테스트를 수행하는 과정에서 관 재질별로 하수재이용수의 수질변화를 관찰한 결과, 암모니아성 질소의 경우, 부식이 크게 발생한 CIP 및 GSP에서 부식이 발생하지 않은 STSP 및 PVCP와 비교하여 질산염으로 전환되는 비율이 월등히 높았고, 부식생성물이 가장 많은 CIP에서 질산성 질소의 탈질이 가장 높게 일어나는 현상을 관찰할 수 있었다. 또한, CIP에서는 SRB (Sulfur Reducing Bacteria)에 의한 황산이온의 소모가 나타났으며, EDS (Energy Dispersive X-ray spectrometer System) 분석 결과 MIC (Microbiologically Induced Corrosion)가 있었음을 확인할 수 있었다.

자율 감지 및 확률론적 신경망 기반 패턴 인식을 이용한 배관 구조물 손상 진단 기법 (Pipeline Structural Damage Detection Using Self-Sensing Technology and PNN-Based Pattern Recognition)

  • 이창길;박웅기;박승희
    • 비파괴검사학회지
    • /
    • 제31권4호
    • /
    • pp.351-359
    • /
    • 2011
  • 최근 토목, 기계 및 항공 분야에서 구조물의 안전성 및 적정 성능 수준 확보를 위하여 구조물의 결함 및 노후화에 의한 성능저하 등을 상시적으로 모니터링하기 위한 관심이 높아지고 있다. 실제 구조물에서는 내부 미세 균열에서부터 국부 좌굴, 볼트 풀림, 피로 균열 등과 같이 다양한 형태의 손상이 복합적으로 발생 가능한데, 복합 손상을 단일 모드 계측 시스템으로부터 진단하기는 매우 어렵다. 따라서 본 연구에서는 이러한 복합 손상을 효율적으로 진단하기 위하여 선행 연구에서 제안된 압전센서를 이용한 자가 계측 회로 기반의 다중 모드 계측 시스템을 적용하였다. 자가 계측 회로 기반 다중 모드 계측 시스템은 크게 두 가지 형태의 신호를 계측한다. 첫 번째 모드는 임피던스 계측으로부터 특정 주파수 대역의 구조 응답을 계측하며, 두 번째 모드는 유도 초음파 계측으로부터 단일 중심 주파수에 해당하는 구조 응답을 계측한다. 복합 손상을 손상 유형별로 분류하기 위하여 E/M 임피던스와 유도 초음파의 계측으로부터 추출한 특성을 이용하여 2차원 손상지수를 계산하고 이를 지도학습 기반 패턴인식 기법 중 확률론적 신경망 기법에 적용한다. 제안된 기법의 적용성 검토를 배관 구조물에 인위적으로 다중 손상을 생성시켜 실험을 수행하였다.

온돌 파이프라인 관리를 위한 초음파 캐비테이션 효과에 대한 실험적 분석 (An Experimental Analysis of Ultrasonic Cavitation Effect on Ondol Pipeline Management)

  • 이웅균
    • 한국건축시공학회지
    • /
    • 제24권1호
    • /
    • pp.67-75
    • /
    • 2024
  • 한국은 주택 난방 방식으로 대부분 온돌 파이프라인을 이용한 방법을 채택하고 있으나 콘크리트 속에 매설되어 있는 특성으로 인해 설치 후 배관 내부의 지속적인 관리를 하기가 쉽지 않다. 온돌 배관은 장기간 사용을 하면 슬러지나 부식 산화물, 미생물 등이 배관 내벽에 퇴적되면서 난방의 효율이 나빠져서 심한 경우에는 열화에 의한 부식, 스케일 등의 문제를 일으키기도 한다. 따라서 본 연구는 온돌 파이프라인의 유지관리를 위하여 초음파 발생 방식을 제안하고 그 가능성을 실험으로 확인하는데 그 목적이 있다. 본 연구를 위한 초음파 발생 장치는 3가지로 제시되며, 표면 진동형, 외부 발생형, 내부 발생형이 그것이다. 관내 오염물은 분말형 가루, 슬러지형 가루, 액상 물질로 선정하였다. 초음파 발생 이후 시간에 따른 세척 효과를 확인하였으며, 세척 결과는 이미지 분석 방법을 통해 산출하였다. 실험 결과, 배관 외부에서 발생시킨 초음파가 효과적임을 알 수 있었으나 배관 내부에서 발생시킨 초음파 역시 유사한 세척 결과를 얻었다. 온돌 배관의 특성 상 외부 발생이 불가능하므로 내부의 발생을 통한 세척 효과가 있을 것으로 기대된다. 향후 배관 내부 발생 장치의 개발을 통해 온돌 파이프라인의 유지관리를 위한 새로운 방식의 제시가 가능할 것으로 기대된다.