• 제목/요약/키워드: Pipe-line

검색결과 500건 처리시간 0.034초

배관 제작, 설치 ISO 도면 및 BOM 정보 자동 생성 시스템 개발 (Development of Automatic Pipe ISO-Drawing and BOM Generation System)

  • 우일국;김신형;허철은;조용남;구자민;김대진
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2005년도 특별논문집
    • /
    • pp.127-133
    • /
    • 2005
  • DSME has successfully developed the unified CAD system (DACOS) for the commercial ship based on its design know-how accumulated for several years. Currently, DSME is expanding the unified CAD system to plant and special ship design. In this paper, the development of pipe design, especially, isometric drawing and BOM(Bill of Material) generation will be introduced isometric drawing and BOM generation are major activities of pipe design in shipbuilding. The drawing is used for pipe construction and installation while the BOM is used for purchasing and manufacturing pipe line. These activities are time-consuming and tedious jobs done by designers because the drawing should be generated as a non-scaled symbolized drawing that can be easily understood and the BOM information should be extracted without mistake. Therefore, we implemented automatic isometric drawing and 80M generation system for pipe design. In this paper, the developed system and the used technology will as well be introduced and a design output in a plant project as an applied example will be illustrated.

  • PDF

수소저장합금을 이용한 열수송시스템 구성 (Composition of the heat transportation system using metal hydride)

  • 심규성;명광식;김종원;한상도
    • 한국수소및신에너지학회논문집
    • /
    • 제10권1호
    • /
    • pp.41-48
    • /
    • 1999
  • 산업단지에서 손실되는 막대한 폐열을 효율적으로 회수하고 이를 인근의 배후 도시에서 활용하기 위해서는 이에 적합한 열수송기술이 필요하다. 현재 온수나 증기에 의한 열수송은 배관을 통하여 열손실 및 마찰손실 등이 발생하므로 수송거리는 3 내지 5km가 한계이다. 그러나 대부분의 공단이 도시지역에서 10km 이상 떨어져 있으므로 이들 지역에서 발생되는 폐열을 적절히 활용하기 위해서는 새로운 열수송시스템이 개발되어야 한다. 본 연구에서는 수소저장합금이 수소를 흡수 또는 방출하면서 발열반응과 흡열반응을 일으키는 특성을 이용하여 산업공단지역의 폐열로부터 수소저장합금의 수소를 방출시키고, 이 수소를 인근 도시지역에 파이프라인으로 수송한 후 필요시 또 다른 수소저장합금과 반응시켜 열을 얻을 수 있는 열수송시스템에 대하여 고찰하였다. 이 시스템에서는 난방의 목적 외에도 수소의 흡수 방출온도가 낮은 합금을 이용하여 냉열을 얻을 수도 있으며, 폐열의 저장수단으로, 또한 수소를 수송함으로서 열수송의 수단으로 활용할 수 있다. 이에 따라 수소저장합금을 이용한 열수송기술의 문제점과 열수송시스템의 구성기술에 대하여도 검토하였다.

  • PDF

MIKE SWMM모형을 이용한 도시유역 유출분석에 관한 연구 (Analysis on the Runoff of Urban Watershed using MIKE SWMM Model)

  • 김종석;최경록;안재현;문영일
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.862-866
    • /
    • 2005
  • 도시유역의 유출분석을 위하여 국내에서 많이 사용하고 있는 모형들로는 ILLUDAS, SWMM이 대표적이라고 할 수 있다. 그러나 국내의 대부분의 도시하천의 경우 합류식의 배수계통을 가지고 있어, 홍수시에 하수관거용량을 초과하는 우수량은 하천을 통해 배수가 되고 있다. 이러한 배수계통을 갖는 하천에 대하여 대상유역의 배수관망 자료 부족과 Modeling의 어려움으로 인해 도시유출모형이 아닌 HEC-HMS모형과 같은 유역추적법을 통해 유출분석이 이루어지고 있다. 또한 기존 논문에서 제시한 도시유출모형에 하도추적을 결합한 강우-유출 모의는 정확성 결여 및 번거로운 단점이 있다. 따라서 본 논문에서는 보다 안정적인 해석 모형인 MIKE SWMM 모형을 사용하여 과거 침수자료와 DEM 자료 및 수치 배수관망 자료를 통한 유역 및 배수관망 자료를 구축하고 유역에 대해서는 Runoff Block을 사용하고, 하수관거와 본류에 대해서는 Dynamic 방정식을 이용한 Extran Block을 적용하여 유출분석을 실시하고 그 결과를 기존의 방법들과 비교하여 각각의 장단점 및 적용성을 밝히고 개선방향등을 제시하고자 하였다.

  • PDF

냉매 내 수분의 혼입량이 차량 에어컨의 냉각성능에 미치는 영향 (Effects of Water Amount in Refrigerant on Cooling Performance of Vehicle Air Conditioner)

  • 문성원;민영봉;정태상
    • Journal of Biosystems Engineering
    • /
    • 제36권5호
    • /
    • pp.319-325
    • /
    • 2011
  • This study was conducted to figure out the diagnosis basis of cooling performance depending on water amount in the refrigerant of air conditioner, which can be estimated by the temperatures and pressures along the refrigerant circulation line. A car air conditioner of SONATA III (Hyundai motor Co., Korea) was tested at maximum cooling condition at the engine speed of 1500 rpm in the room controlled at 33~$35^{\circ}C$ air temperature and 55~57% relative humidity conditionally. Measured variables were temperature differences between inlet and outlet pipe surfaces of the compressor, condenser, receive drier and evaporator; and high pressure and low pressure in the refrigerant circulation line; and temperature difference between inlet and outlet air of the cooling vent of evaporator. In this study, changes of the water amount in the refrigerant were correlated to the temperatures and pressure changes and also water amount caused poor cooling performance. As water amount increased in the refrigerant in the air conditioner, the performance of the cooling or the heat transfer became worse. Temporal variations of the surface temperature of the evaporator outlet pipe and the low-side pressure showed various patterns that could estimate the water amount. When the water amount caused bad cooling performance, the patterns of the temperature of the evaporator outlet pipe indicated irregular fluctuation greater than $5^{\circ}C$. When the diagnosis system is using just external sensors of the low-side pressure and the temperatures of inlet and outlet air of cooling vent of the evaporator, the precise pattern of bad cooling performance caused by excess water amount in the cooling line was irregular pressure fluctuation, 25 kPa under 120 kPa, and temperature, $12^{\circ}C$ and less.

Analysis on the performance and internal flow of a tubular type hydro turbine for vessel cooling system

  • Chen, Zhenmu;Kim, Joo-Cheong;Im, Myeong-Hwan;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권10호
    • /
    • pp.1244-1250
    • /
    • 2014
  • The temperature of the main engine cabin of commercial vessel is very high. The material SS-316L undergoes creep damage at temperatures exceeding $450^{\circ}C$. It is essential to maintain the highly stressed engine cabin below the creep regime. Hence, seawater is employed in this kind of maritime vehicles as cooling liquid. It obtains the thermal energy at the cooling pipe line after passing through main engine cooling system. To harness the energy in the seawater, a turbine can be installed to absorb the energy in the seawater before being released into the sea. In this study, a cooling pipe line is selected to apply the tubular type hydro turbine for transferring the energy. Numerical analysis for investigating the performance and the internal flow characteristics of the tubular turbine is conducted. The results show that the maximum efficiency of 85.8% is achieved although the efficiency drops rapidly at partial flow rate condition. The efficiency descends slowly at the condition of excess flow rate. There is a relatively wide operating range of flow rate of this turbine to keep high efficiency at the excess flow rate condition. For the internal flow of the turbine, there is uniform streamline on the suction and pressure sides of the blade at the design point. However, the secondary flow appears at the suction and pressure sidesat the excess flow rate.In addition, it appears only at pressure side at the partial flow rate condition.

MIKE SWMM 모형을 이용한 도시유역 유출분석에 관한 연구 (Runoff Analysis of Urban Watershed using MIKE SWMM Model)

  • 김종석;안재현;오태석;문영일
    • 한국수자원학회논문집
    • /
    • 제38권11호
    • /
    • pp.907-916
    • /
    • 2005
  • 도시유역의 유출분석을 위하여 국내에서 많이 사용하고 있는 모형들로는 ILLVDAS, SWMM이 대표적이라고 할 수 있다. 그러나 국내의 대부분의 도시하천의 경우 합류식의 배수계통을 가지고 있어, 홍수시에 하수관거용량을 초과하는 우수량은 하천을 통해 배수가 되고 있다. 이러한 배수계통을 갖는 하천에 대하여 대상유역의 배수관망 자료 부족과 Modeling의 어려움으로 인해 도시유출모형이 아닌 HEC-HMS 모형과 같은 유역추적법을 통해 유출분석이 이루어지고 있다. 또한 기존 논문에서 제시한 도시유출모형에 하도추적을 결합한 강우-유출 모의는 정확성 결여 및 번거로운 단점이 있다. 따라서 본 논문에서는 보다 안정적인 해석 모형인 MIKE SWMM 모형을 사용하여 과거 침수자료와 DEM 자료 및 수치 배수관망 자료를 통한 유역 및 배수관망 자료를 구축하고 유역에 대해서는 Runoff Block을 사용하고, 하수관거와 본류에 대해서는 Dynamic 방정식을 이용한 Extran Block을 적용하여 유출분석을 실시하고 그 결과를 기존의 방법들과 비교하여 각각의 장단점 및 적용성을 밝히고 개선방향등을 제시하고자 하였다.

가압경수로 주증기관 파단시 증기발생기 2차측 과도 열수력 응답에 미치는 오리피스형 유량제한기의 영향 (EFFECTS OF AN ORIFICE-TYPE FLOW RESTRICTOR ON THE TRANSIENT THERMAL-HYDRAULIC RESPONSE OF THE SECONDARY SIDE OF A PWR STEAM GENERATOR TO A MAIN STEAM LINE BREAK)

  • 조종철;민복기
    • 한국전산유체공학회지
    • /
    • 제20권3호
    • /
    • pp.87-93
    • /
    • 2015
  • In this study, a numerical analysis was performed to simulate the thermal-hydraulic response of the secondary side of a steam generator(SG) model equipped with an orifice-type SG outlet flow restrictor to a main steam line break(MSLB) at a pressurized water reactor(PWR) plant. The SG analysis model includes the SG upper steam space and the part of the main steam pipe between the SG outlet and the broken pipe end. By comparing the numerical calculation results for the present SG model to those obtained for a simple SG model having no flow restrictor, the effects of the flow restrictor on the thermal-hydraulic response of SG to the MSLB were investigated.

Identification of hydrogen flammability in steam generator compartment of OPR1000 using MELCOR and CFX codes

  • Jeon, Joongoo;Kim, Yeon Soo;Choi, Wonjun;Kim, Sung Joong
    • Nuclear Engineering and Technology
    • /
    • 제51권8호
    • /
    • pp.1939-1950
    • /
    • 2019
  • The MELCOR code useful for a plant-specific hydrogen risk analysis has inevitable limitations in prediction of a turbulent flow of a hydrogen mixture. To investigate the accuracy of the hydrogen risk analysis by the MELCOR code, results for the turbulent gas behavior at pipe rupture accident were compared with CFX results which were verified by the American National Standard Institute (ANSI) model. The postulated accident scenario was selected to be surge line failure induced by station blackout of an Optimized Power Reactor 1000 MWe (OPR1000). When the surge line failure occurred, the flow out of the surgeline was strongly turbulent, from which the MELCOR code predicted that a substantial amount of hydrogen could be released. Nevertheless, the results indicated nonflammable mixtures owing to the high steam concentration released before the failure. On the other hand, the CFX code solving the three-dimensional fluid dynamics by incorporating the turbulence closure model predicted that the flammable area continuously existed at the jet interface even in the rising hydrogen mixtures. In conclusion, this study confirmed that the MELCOR code, which has limitations in turbulence analysis, could underestimate the existence of local combustible gas at pipe rupture accident. This clear comparison between two codes can contribute to establishing a guideline for computational hydrogen risk analysis.