• Title/Summary/Keyword: Pipe-and-Filter

Search Result 77, Processing Time 0.033 seconds

AN EXPERIMENT ON THE HEARING OF RAINBOW TROUT IN THE INDOOR AQUARIUM IN BUSAN (부산지방에서 실내수조를 이용한 무지개송어의 사육실험)

  • KIM In-Bae;JO Jae Yoon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.10 no.4
    • /
    • pp.267-273
    • /
    • 1977
  • Rainbow trout were reared in a small indoor aquarium which was equipped with a simple recirculating biofilter combined with a small amount of inflowing water for 199 days from April 25 to November 10, 1977 in Busan where very hot summer air temperature is encountered, and results obtained were promissing as following; 1. The aquarium has dimensions of $1m\;\times\;1m\;\times\;67cm(depth)$, and a bottom center sedimentation chamber of conical type through which out-flowing water is pushing fecal matter and other detritus outward. The conical sedimentation chamber measures 20 cm depth and 20 cm diameter at its upper mouth and tapers to the bottom end which is connected to 4 cm diameter draining pipe. The draining pipe goes through under the tank and then is elevated on the side. The water depth was maintained at about 40 cm depth by adjusting the heigh of draining pipe. The filter bed contained 16 l of $3\~5\;mm$ zeolite gravels, and water circulation rate was about 1030 l/hr. 2. Continuous inflowing water resulted in a good elimination of waste materials through its outflowing water thus reducing waste loading in the filter. 3. Mean temperature of water in the rearing aquarium containing about 400 l water volume was maintained at around 20 to $22^{\circ}C$ by 0.59 l/min of the inflowing well water which usually maintained the temperature of $17^{\circ}C$ during the hot summer season from the first of July to the first of October when the 10-days-mean air temperature ranged from $20^{\circ}\;to\;27.3^{\circ}C$ $(total\;mean\;24.6^{\circ}C) $ and under this condition the fish continued normal growth. 4. The production per 1 l/min of inflowing water with this simple biofilteration reached 30 hg. 5. The total cost including all feed and power during this experimental rearing period fell well within the economic establishment and if the feed and filteration system are improved the benefit-cost ratio will be much increased.

  • PDF

A study for recycling plan of excavated soil and filter cake of slurry shield TBM for road construction (도로공사 이수식 쉴드 TBM 굴착토 및 필터케이크 재활용방안 연구)

  • Nam, Sung-min;Park, Seo-young;Ahn, Byung-cheol
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.599-615
    • /
    • 2022
  • In order to excavate underground tunnel most safely such as Han river, the slurry shield TBM method is applied to cope with face of high water pressure for many metro projects. In downtown subway project most of excavated soil is discharged externally whereas in road construction excavated soil is used as filling materials so it becomes important factor for success of the project. After excavated soil, weathered rock and soft rock are discharged with bentonite through discharge pipe to slurry treatment plant then those soils are separated in separation plant according to those size. Fine grained soil has been discarded together with filter cake but it is not toxic and can be mixed with coarse aggregate in proper ratio so this study is performed to find use of qualified filling material to meet quality standard. Therefore, in this study, legal standards and quality standards for the utilization of excavated soil of the slurry shield TBM method were examined and test was conducted to derive recycling way for filter cake and aggregate. And a plan for using it as a filling material for road construction was derived. Because bentonite is a clay composed of montmorillonite, and the excavated soil in the tunnel is also non-toxic, disposal of this material can waste social cost so it is expected to be helpful in the underground space development project that carries out the TBM project by recycling it as a valuable resource.

A new approach to enhancement of ground penetrating radar target signals by pulse compression (파형압축 기법에 의한 GPR탐사 반사신호 분해능 향상을 위한 새로운 접근)

  • Gaballah, Mahmoud;Sato, Motoyuki
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.77-84
    • /
    • 2009
  • Ground penetrating radar (GPR) is an effective tool for detecting shallow subsurface targets. In many GPR applications, these targets are veiled by the strong waves reflected from the ground surface, so that we need to apply a signal processing technique to separate the target signal from such strong signals. A pulse-compression technique is used in this research to compress the signal width so that it can be separated out from the strong contaminated clutter signals. This work introduces a filter algorithm to carry out pulse compression for GPR data, using a Wiener filtering technique. The filter is applied to synthetic and field GPR data acquired over a buried pipe. The discrimination method uses both the reflected signal from the target and the strong ground surface reflection as a reference signal for pulse compression. For a pulse-compression filter, reference signal selection is an important issue, because as the signal width is compressed the noise level will blow up, especially if the signal-to-noise ratio of the reference signal is low. Analysis of the results obtained from simulated and field GPR data indicates a significant improvement in the GPR image, good discrimination between the target reflection and the ground surface reflection, and better performance with reliable separation between them. However, at the same time the noise level slightly increases in field data, due to the wide bandwidth of the reference signal, which includes the higher-frequency components of noise. Using the ground-surface reflection as a reference signal we found that the pulse width could be compressed and the subsurface target reflection could be enhanced.

Removal of discoloration materials by water mains cleaning on water distribution pipes (관 세척에 따른 색도성 물질의 제거 효과)

  • Lee, Ho-Min;Choi, Tae-Ho;Yun, Hyun-Woo;Kim, Dong-Hong;Bae, Cheol-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.4
    • /
    • pp.267-276
    • /
    • 2020
  • In this study, air scouring cleaning was selected and applied among 5 small blocks (S1~S5) in domestic S cities to analyze the cleaning effect of particles causing discoloration. In order to identify the cleaning effect, 10 locations were selected as water quality investigation point, such as the stagnant or water mains ends. Removal of solids, variation of particle components, weight and concentration were analyzed. And the level of the cleanness of the surface inside water mains using endoscope was investigated. As a result of analysis, the solids discharged after cleaning were mainly sand and gravel, pieces related to pipe materials, and corrosion products. As a result of analyzing the concentrated particles of the filter before and after cleaning, it was found that the change in discoloration on the filter was large. In addition, as a result of comparing the weight and the concentration of the particles, it was found that the particles causing discoloration were significantly removed after cleaning. From the results of the endoscopy, it was confirmed that most of the precipitated and accumulated dark yellow discoloration matters inside water mains were removed through cleaning. Therefore, it seems that the particles causing discoloration in water decreased after cleaning. Therefore, it is expected that, if properly cleaning was applied, matters that cause discoloration can be removed from the water mains, and customer's complaints can also be reduced through water quality improvement.

The Effect of the Flow Paths of the Wastewater to the Performance of the Vegetative Filter Strip for Phosphorus Removal (축산 폐수 이동경로가 초생대의 인제거 기능에 미치는 영향)

  • Kim , Young-Jin;Yu , Chan;Geohring , Larry D;Steenhuis , Tammo S.
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.5
    • /
    • pp.155-163
    • /
    • 2004
  • The objectives of this study were to characterize the wastewater flow through the VFS, and relate this to the P removal in the VFS. A total of 68 subsurface wells (20∼40 cm below the soil surface) and 35 surface wells (0~5 cm), and the application of chloride tracer were used to investigate flow paths and soluble reactive P (SRP) removal from the 21 m wide and 33 m long VFS receiving dairy milkhouse waste. The early chloride breakthroughs in wells in the center of the VFS showed that the milkhouse waste flows preferentially down in the center of the hillslope. The locally saturated area created near the discharge pipe in the center of the VFS accelerates surface flow that contributed to rapid transport of P to the down slope area. Although VFS of 33m long eventually reduced SRP to lower than 0.2 mg/L in most cases, SRP is less effectively removed in the areas where soil saturation occurred. It is suggested that the effort to distribute the wastewater uniformly to avoid soil saturation and reduce the flow velocity need to be considered in new designs.

Empirical Determination of a CT X-ray Spectra by Numerical Analysis using Transmission Data (투과선량의 수치해석에 의한 전산화단층영상장치 X선의 에너지 분포결정)

  • 최태진;김옥배;서수지
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.35-43
    • /
    • 1997
  • The knowledge of x-ray spectra is highly desirable in some investigation involves the differential penetrating power and absorption coefficient correction of various photon beam. The transmission data were obtained from the 80 kVp and 120 kVp of CT x-ray beam with the aluminium filter which is designed in a 30 cm of diameter and pipe-typed filter was prepared from 5.0 mm upto 92.3 mm of thickness. To obtain the reconstructed spectra of CT x-ray, the investigator used the iterative numerical analysis which has been extended to include the tungsten characteristics from experimental transmission data with energy interval of 2 keV. Comparison of the calculated transmission data from the reconstructed spectra with that of measurement shows good agreement in both 80 kVp and 120 kVp x-ray beams. This numerical analysis based on iteratively calculation of fractional exposure per energy interval shows the high potential of usefulness of determination the x-ray spectra from the attenuated beam in diagnostic energy range.

  • PDF

A Numerical Method to Calculate Drainage Time in Large Transmission Pipelines Filter (대구경 관로의 배수시간 산정을 위한 수치해석 기법)

  • Shin, Byoung-Ho;Choi, Doo-Yong;Jeong, Kwansue
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.511-519
    • /
    • 2017
  • Multi-regional water supply system, which installed for supplying multiple water demands, is characterized by large-sized, long-distance, tree-type layout. This system is vulnerable to long-standing service interruption when a pipe breaks is occurred. In this study, a numerical method is proposed to calculate drainage time that directly affects time of service interruption. To begin with, governing equations are formulated to embed the delayed drainage effect by the friction loss, and to resolve complicated connection of pipelines, which are derived from the continuity and energy equations. The nonlinear hydraulic equations are solved by using explicit time integration method and the Newton-Raphson method. The developed model is verified by comparing the result with analytical solution. Furthermore, the model's applicability is validated by the examples of pipelines in serial, in parallel, and complex layout. Finally, the model is utilized to suggest an appropriate actions to reduce the deviation of draining time in the C transmission line of the B multi-regional water supply system.

THERMAL HYDRAULIC ISSUES OF CONTAINMENT FILTERED VENTING SYSTEM FOR A LONG OPERATING TIME

  • Na, Young Su;Ha, Kwang Soon;Park, Rae-Joon;Park, Jong-Hwa;Cho, Song-Won
    • Nuclear Engineering and Technology
    • /
    • v.46 no.6
    • /
    • pp.797-802
    • /
    • 2014
  • This study investigated the thermal hydraulic issues in the Containment Filtered Venting System (CFVS) for a long operating time using the MELCOR computer code. The modeling of the CFVS, including the models for pool scrubbing and the filter, was added to the input file for the OPR-1000, and a Station Blackout (SBO) was chosen as an accident scenario. Although depressurization in the containment building as a primary objective of the CFVS was successful, the decontamination feature by scrubbing and filtering in the CFVS for a long operating time could fail by the continuous evaporation of the scrubbing solution. After the operation of the CFVS, the atmosphere temperature in the CFVS became slightly above the water saturation temperature owing to the release of an amount of steam with high temperature from the containment building to the scrubbing solution. Reduced pipe diameters at the inlet and outlet of the CFVS vessel mitigated the evaporation of scrubbing water by controlling the amount of high-temperature steam and the water saturation temperature.

Identification of the Environmentally Problematic Input/Environmental Emissions and Selection of the Optimum End-of-pipe Treatment Technologies of the Cement Manufacturing Process (시멘트 제조공정의 환경적 취약 투입물/환경오염물 파악 및 최적종말처리 공정 선정)

  • Lee, Joo-Young;Kim, Yoon-Ha;Lee, Kun-Mo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.8
    • /
    • pp.449-455
    • /
    • 2017
  • Process input data including material and energy, process output data including product, co-product and its environmental emissions of the reference and target processes were collected and analyzed to evaluate the process performance. Environmentally problematic input/environmental emissions of the manufacturing processes were identified using these data. Significant process inputs contributing to each of the environmental emissions were identified using multiple regression analysis between the process inputs and environmental emissions. Optimum combination of the end-of-pipe technologies for treating the environmental emissions considering economic aspects was made using the linear programming technique. The cement manufacturing processes in Korea and the EU producing same type of cement were chosen for the case study. Environmentally problematic input/environmental emissions of the domestic cement manufacturing processes include coal, dust, and $SO_x$. Multiple regression analysis among the process inputs and environmental emissions revealed that $CO_2$ emission was influenced most by coal, followed by the input raw materials and gypsum. $SO_x$ emission was influenced by coal, and dust emission by gypsum followed by raw material. Optimization of the end-of-pipe technologies treating dust showed that a combination of 100% of the electro precipitator and 2.4% of the fiber filter gives the lowest cost. The $SO_x$ case showed that a combination of 100% of the dry addition process and 25.88% of the wet scrubber gives the lowest cost. Salient feature of this research is that it proposed a method for identifying environmentally problematic input/environmental emissions of the manufacturing processes, in particular, cement manufacturing process. Another feature is that it showed a method for selecting the optimum combination of the end-of-pipe treatment technologies.

A Study on Effects of Tuning Intake and Exhaust Systems upon Engine Performance in a Driving Gasoline Car (운행 가솔린자동차 엔진성능에 미치는 튜닝 흡기 및 배기 시스템의 효과에 관한 연구)

  • Bae, Myung-whan;Ku, Young Jin;Park, Hui-seong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.11
    • /
    • pp.775-784
    • /
    • 2017
  • The purpose of this study was to analyse the basic data of the engine tuning inspection by confirming the working possibility of effective engine tuning and identifying the characteristics of tuned engine that are no problem with the safety operation and environment in a driving gasoline car. The effects of tuned engine on the characteristics of air/fuel ratio and performance at a wide range of engine speeds were experimentally investigated by the actual driving car with a four-cycle, four-cylinder DOHC, turbo-intercooler, water-cooled gasoline engine operating under four types of non-tuning, and tuning 2-1, 2-2 and 2-3. The tuned parts of engine in a driving gasoline car include the intake manifold, intake pipe, air filter, exhaust manifold, exhaust pipe and silencer. In this experiment, the air-fuel ratio and torque of both non-tuned and tuned engines that one person took on board in the car with a five-speed automatic transmission were measured by the chassis dynamometer(Dynojet 224xLC). It was found that the maximum torque of tuned engine in a driving gasoline car was increased by 103.68% on average, while the maximum output was increased by 119.68% on average in comparison to the non-tuned engine.