Determining the Time of Least Water Use for the Major Water Usage Types in District Metered Areas (상수관망 블록의 대표적인 용수사용 유형에 대한 최소 용수사용 시간의 결정)

  • Park, Suwan;Jung, So-Yeon;Sahleh, Vahideh
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.3
    • /
    • pp.415-425
    • /
    • 2015
  • Aging water pipe networks hinder efficient management of important water service indices such as revenue water and leakage ratio due to pipe breakage and malfunctioning of pipe appurtenance. In order to control leakage in water pipe networks, various methods such as the minimum night flow analysis and sound waves method have been used. However, the accuracy and efficiency of detecting water leak by these methods need to be improved due to the increase of water consumption at night. In this study the Principal Component Analysis (PCA) technique was applied to the night water flow data of 426 days collected from a water distribution system in the interval of one hour. Based on the PCA technique, computational algorithms were developed to narrow the time windows for efficient execution of leak detection job. The algorithms were programmed on computer using the MATLAB. The presented techniques are expected to contribute to the efficient management of water pipe networks by providing more effective time windows for the detection of the anomaly of pipe network such as leak or abnormal demand.

A Study on Design Support Technique for Water Distribution Network using GIS (GIS를 이용한 상수관로 설계지원 기법 연구)

  • Cho, Hyo-Seob;Choi, Seung-Chul;Lee, Gi-Ha;Cho, Bok-Hwan;Kim, Jeong-Yup
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.2
    • /
    • pp.103-116
    • /
    • 2005
  • Although there have been many researches to construct a database of water distribution networks using GIS, most of them were not linked with an model for the analysis of pipe networks because it is difficult to make spatial data about complex water distribution networks for building a detail model. Therefore, it is necessary to develop the method based on GIS to build geographical data for design of water distribution pipeline systems. In this study, an innovated design support technique using GIS is proposed for a hydraulic analysis model of water distribution networks. With the function of spatial analysis in GIS system, the results from a pipe network model are used to analyze the suitability of the location of pipeline network, the spatial suitability comprised the analysis of the degree of pipe age, the altitude distribution of water pressure, and the water supply system for the customer.

  • PDF

Study on the applicability of the principal component analysis for detecting leaks in water pipe networks (상수관망의 누수감지를 위한 주성분 분석의 적용 가능성에 대한 연구)

  • Kim, Kimin;Park, Suwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.2
    • /
    • pp.159-167
    • /
    • 2019
  • In this paper the potential of the principal component analysis(PCA) technique for the application of detecting leaks in water pipe networks was evaluated. For this purpose the PCA was conducted to evaluate the relevance of the calculated outliers of a PCA model utilizing the recorded pipe flows and the recorded pipe leak incidents of a case study water distribution system. The PCA technique was enhanced by applying the computational algorithms developed in this study which were designed to extract a partial set of flow data from the original 24 hour flow data so that the effective outlier detection rate was maximized. The relevance of the calculated outliers of a PCA model and the recorded pipe leak incidents was analyzed. The developed algorithm may be applied in determining further leak detection field work for water distribution blocks that have more than 70% of the effective outlier detection rate. However, the analysis suggested that further development on the algorithm is needed to enhance the applicability of the PCA in detecting leaks by considering series of leak reports happening in a relatively short period.

Seismic Analysis of Firefighting Pipe Networks (소방배관 형상에 따른 배관 내진해석)

  • Choi, Ho-Sung;Lee, Jae-Ou
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.149-154
    • /
    • 2019
  • The stability of firefighting pipes is crucial in the event of an earthquake. In Korea, specification-based designs are used in accordance with NFSC. However, engineering performance-based designs are used for buildings that have special requirements. For firefighting pipes, tree type pipe networks are usually utilized in buildings; however, they are characterized by several limitations. Hence, grid type and loop type networks are being utilized lately. Earthquake-resistant designs for firefighting pipes in Korea utilize NFPA 13 as the cookbook. Nevertheless, an engineering analysis is required to verify its reliability. The NFPA 13 standard used in Korea is a design method for engineers who lack earthquake engineering analysis knowledge of pipes and adapt ASCE and ASME guidelines. Earthquake resistant designs in Korea review braces only. Hence, various analyses under load conditions, such as the internal pressure of a pipe, force exerted by a continuous load, and an earthquake, are required to ensure reliability. An engineering earthquake-resistance analysis showed that tree type pipe networks are less stable than grid and loop type pipe networks. A comparison of earthquake-resistance analysis based on stress and strain revealed that strain analysis exhibited a conservative result value in the range of over-stress. Therefore, for the earthquake-resistance analysis of pipes, it is rational that engineers perform analysis to achieve the required standards through engineering analysis rather than uniform calculations, which should also be analyzed considering various analysis conditions.

Leak Detection in a Water Pipe Network Using the Principal Component Analysis (주성분 분석을 이용한 상수도 관망의 누수감지)

  • Park, Suwan;Ha, Jaehong;Kim, Kimin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.276-276
    • /
    • 2018
  • In this paper the potential of the Principle Component Analysis(PCA) technique that can be used to detect leaks in water pipe network blocks was evaluated. For this purpose the PCA was conducted to evaluate the relevance of the calculated outliers of a PCA model utilizing the recorded pipe flows and the recorded pipe leak incidents of a case study water distribution system. The PCA technique was enhanced by applying the computational algorithms developed in this study. The algorithms were designed to extract a partial set of flow data from the original 24 hour flow data so that the variability of the flows in the determined partial data set are minimal. The relevance of the calculated outliers of a PCA model and the recorded pipe leak incidents was analyzed. The results showed that the effectiveness of detecting leaks may improve by applying the developed algorithm. However, the analysis suggested that further development on the algorithm is needed to enhance the applicability of the PCA in detecting leaks in real-world water pipe networks.

  • PDF

Assessment of the Deterioration of Large-Diameter Pipe Networks (I) : Development of an Assessment Model (대구경 관로의 노후도 평가 연구(I) : 평가모형 개발)

  • Kim, Eung-Seok;Lee, Seung-Hyun;Yoon, Ki-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.482-487
    • /
    • 2014
  • The purpose of this study (I) is to provide a new methodology for evaluating deterioration of buried pipe networks for the large-diameter old pipe improvement project currently performed by K-water. To develop a new assessment model for large-diameter pipe deterioration, this study has investigated the three representative methods for the pipe deterioration assessment such as evaluation methods 1995 and 2002, and the state evaluation method through literature reviews. The ten assessment factors were selected by considering large-diameter pipe characteristics as well as common factors with high priority in the three methods. Also, the weighting of the factors was estimated by a regression equation from experiments and analysis on domestic large-diameter pipelines and expert survey data. It is expected that the new assessment model developed by analysing the existing three models is more reliable to assess the deterioration of large-diameter pipe networks.

A Study on the Effect of Gas Composition at Gas Supply Point on the Pressures in Gas Pipe Networks (가스 배관망에서 인입가스의 조성이 배관망 내 압력에 미치는 영향에 관한 연구)

  • Chang, Seung-Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.2 s.35
    • /
    • pp.1-4
    • /
    • 2007
  • Natural gas has different gas composition according to imported gas region, and the difference of gas composition affects pressure loss value occurred in pipe networks, Therefore, using real gas composition instead of averaged gas composition can obtain more reliable results for pipe network analysis. In this study, the effect of real gas composition at gas supply points on the demand pressure has been analyzed. To compare the results, the calculated pressure values for averaged gas composition at all the supply points have been used. From the results, we found that the effect of real gas composition consideration on demand pressure was considerable, and the real gas composition has to be considered for reliable pipe network analysis in gas industry.

  • PDF

Safety analysis and deterioration evaluation of water pipe for improvement according to service year (상수도관의 개량을 위한 시간에 따른 노후도 및 안전성 분석)

  • Kwon, Hyuk Jae;Lee, Kyung Je
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.8
    • /
    • pp.589-597
    • /
    • 2021
  • In this study, corrosion depth equation was suggested according to real measured corrosion data, and then management indexes of pipe network which can determine the deterioration rate and safety rate has been established and applied to real pipe networks. Furthermore, reliability analysis and management index analysis have been conducted to estimate and compare the deterioration rate. From the results of reliability analysis, it was found that probability of failure of 200 mm steel pipe can be increased from 4.36% at present time to 8.23% after 20years at Gaduk and from 7.35% to 12.99% at Nami. From the results of management index analysis, it was found that deterioration rates of Gaduk and Nami are 1.009 and 1.174, respectively. Priority of improvement and replacement of water pipe can be determined by results of reliability analysis and management index analysis.

Evaluation of Risk Factors to Detect Anomaly in Water Supply Networks Based on the PROMETHEE and ANP (상수도관망의 이상징후 판정을 위한 위험요소 평가 - PROMETHEE와 ANP 기법 중심으로)

  • Hong, Sung-Jun;Lee, Yong-Dae;Kim, Sheung-Kown;Kim, Joong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.1 s.162
    • /
    • pp.35-46
    • /
    • 2006
  • In this study, we proposed a layout of the integrated decision support system in order to prevent the contamination and to manage risk in water supply networks for safe and smooth water supply. We evaluated the priority of risk factors to detect anomaly in water supply networks using PROMETHEE and ANP techniques, which are applied to various Multi-Criteria Decision Making area in Europe and America. To develop the model, we selected pH, residual chlorine concentration, discharge, hydraulic pressure, electrical conductivity, turbidity, block leakage and water temperature as the key data item. We also chose pipe corrosion, pipe burst and water pollution in pipe as the criteria and then we present the results of PROMETHEE and ANP analysis. The evaluation results of the priority of risk factors in water supply networks will provide basic data to establish a contingency plan for accidents so that we can establish the specific emergency response procedures.