• 제목/요약/키워드: Pipe modeling system

검색결과 96건 처리시간 0.028초

Data complement algorithm of a complex sewerage pipe system for urban inundation modeling

  • Lee, Seungsoo;An, Hyunuk;Kim, Yeonsu;Hur, Young-Teck;Lee, Daeeop
    • 농업과학연구
    • /
    • 제47권3호
    • /
    • pp.509-517
    • /
    • 2020
  • Geographic information system (GIS) sewer network data are a fundamental input material for urban inundation modeling, which is important to reduce the increasing damages from urban inundation due to climate change. However, the essential attributes of the data built by a local government are often missing because the purpose of building the data is the maintenance of the sewer system. Inconsistent simplification and supplementation of the sewer network data made by individual researchers may increase the uncertainty of flood simulations and influence the inundation analysis results. Therefore, it is necessary to develop a basic algorithm to convert the GIS-based sewage network data into input data that can be used for inundation simulations in consistent way. In this study, the format of GIS-based sewer network data for a watershed near the Sadang Station in Seoul and the Oncheon River Basin in Busan was investigated, and a missing data supplementing algorithm was developed. The missing data such as diameter, location, elevation of pipes and manholes were assumed following a consistent rule, which was developed referring to government documents, previous studies, and average data. The developed algorithm will contribute to minimizing the uncertainty of sewer network data in an urban inundation analysis by excluding the subjective judgment of individual researchers.

곡관 종류에 따른 배수관내의 소음 저감에 관한 실험적 연구 (Experimental Study on the Noise Reduction of Drainage Pipe by a kind of Curve Pipe)

  • 김정훈;심동혁;김경훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.187-192
    • /
    • 2006
  • The effect where the multiple sound arrest ing goes mad to the human being does the zone. From like that cotton, this dissertation the both sides flag executed the research regarding a sound arresting reduction in the object in one example. It compared the piping structure which generally is space-time and a specific piping structure and it tested and research and the modeling regarding a sound arresting reduction the simulation which leads and it executed result and comparison of existing it analyzed. The duplication where the reduction effect is bigger the result general VG2 piping structure than escape it did with the fact that it appears the large effect the piping structure which it connects. Also, the straight pipe effect of multiple sound arresting could not go mad with the fact that.

  • PDF

CFT기둥과 합성보로 구성된 CJS합성구조시스템의 유한요소해석 연구 (Finite Element Analysis Study of CJS Composite Structural System with CFT Columns and Composite Beams)

  • 문아해;신지욱;임창규;이기학
    • 한국지진공학회논문집
    • /
    • 제26권2호
    • /
    • pp.71-82
    • /
    • 2022
  • This paper presents the effect on the inelastic behavior and structural performance of concrete and filled steel pipe through a numerical method for reliable judgment under various load conditions of the CJS composite structural system. Variable values optimized for the CJS synthetic structural system and the effects of multiple variables used for finite element analysis to present analytical modeling were compared and analyzed with experimental results. The Winfrith concrete model was used as a concrete material model that describes the confinement effect well, and the concrete structure was modeled with solid elements. Through geometric analysis of shell and solid elements, rectangular steel pipe columns and steel elements were modeled as shell elements. In addition, the slip behavior of the joint between the concrete column and the rectangular steel pipe was described using the Surface-to-Surface function. After finite element analysis modeling, simulation was performed for cyclic loading after assuming that the lower part of the foundation was a pin in the same way as in the experiment. The analysis model was verified by comparing the calculated analysis results with the experimental results, focusing on initial stiffness, maximum strength, and energy dissipation capability.

부분시스템 합성방법을 이용한 심해저 통합 채광시스템의 효율적인 유연 다물체 동역학 모델링 연구 (A Study on the Efficient Flexible Multibody Dynamics Modeling of Deep Seabed Integrated Mining System with Subsystem Synthesis Method)

  • 윤홍선;김성수;이창호;김형우
    • 대한기계학회논문집A
    • /
    • 제39권12호
    • /
    • pp.1213-1220
    • /
    • 2015
  • 망간단괴를 채집하는 심해저 통합 채광시스템은 채광선, 수직양광관, 중간버퍼, 유연관, 채광로봇으로 구성되어 있다. 최근 심해저 통합 채광시스템 연구에서는 생산성을 극대화하기 위한 다수의 채광로봇으로 구성되는 새로운 다중로봇 통합 채광시스템의 개념이 소개되었다. 본 논문에서는 다중로봇 통합 채광시스템 해석의 효율성을 향상시키고, 다중로봇 시스템의 확장이 이하도록 부분시스템 합성방법이 적되었다. 또한 유연 다물체 동역학이 적된 부분구조로 나눔으로써 수직양광관과 유연관의 대변위가 고려되었다. 일반적인 해석방법과 부분시스템 합성방법의 산술 연산 횟수를 비교함으로써 통합 채광시스템의 부분시스템 합성방법의 이론적인 효율성 연구가 수행되었다.

Vector form intrinsic finite-element analysis of static and dynamic behavior of deep-sea flexible pipe

  • Wu, Han;Zeng, Xiaohui;Xiao, Jianyu;Yu, Yang;Dai, Xin;Yu, Jianxing
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.376-386
    • /
    • 2020
  • The aim of this study was to develop a new efficient strategy that uses the Vector form Intrinsic Finite-element (VFIFE) method to conduct the static and dynamic analyses of marine pipes. Nonlinear problems, such as large displacement, small strain, and contact and collision, can be analyzed using a unified calculation process in the VFIFE method according to the fundamental theories of point value description, path element, and reverse motion. This method enables analysis without the need to integrate the stiffness matrix of the structure, because only motion equations of particles established according to Newton's second law are required. These characteristics of the VFIFE facilitate the modeling and computation efficiencies in analyzing the nonlinear dynamic problem of flexible pipe with large deflections. In this study, a three-dimensional (3-D) dynamical model based on 3-D beam element was established according to the VFIFE method. The deep-sea flexible pipe was described by a set of spatial mass particles linked by 3-D beam element. The motion and configuration of the pipe are determined by these spatial particles. Based on this model, a simulation procedure to predict the 3-D dynamical behavior of flexible pipe was developed and verified. It was found that the spatial configuration and static internal force of the mining pipe can be obtained by calculating the stationary state of pipe motion. Using this simulation procedure, an analysis was conducted on the static and dynamic behaviors of the flexible mining pipe based on a 1000-m sea trial system. The results of the analysis proved that the VFIFE method can be efficiently applied to the static and dynamic analyses of marine pipes.

상수도 시스템의 운영 및 유지관리 의사결정 지원을 위한 시스템다이내믹스 모형의 개발 (Development of a System Dynamics Model to Support the Decision Making Processes in the Operation and Management of Water Supply Systems)

  • 박수완;김규리;김봉재;임기영
    • 한국수자원학회논문집
    • /
    • 제43권7호
    • /
    • pp.609-623
    • /
    • 2010
  • 본 논문에서는 시스템다이내믹스(System Dynamics, SD) 방법론에 입각하여 상수도 시스템의 운영에 내재된 피드백 루프 메커니즘(feedback loop mechanism)을 상수관로의 유지관리와 연관하여 규명하고, 관로 상태의 변화가 전체 시스템에 미치는 영향을포함한 상수도 시스템의 운영지표를예측하여 상수도 시스템의 효율적인운영 및 유지관리를 지원할 수 있는 SD 컴퓨터 모의 모형(simulation model)을 개발하였다. 개발된 모형은 물 공급(water supply) 모형, 관로 유지 관리(pipe maintenance) 모형 및 상수도 재정(water supply business finance) 모형으로 구성된다. 연구대상 지역 상수도 시스템의 운영 자료를 개발된 모형에 적용하여 모형을 검증하고 시스템의 과거 및 미래의 운영 상태를 추정하였으며, 시스템의 운영에 큰 영향을 미치는 정책 지렛대를 발견하였다. 정책 지렛대 발견을 위해 모형의 외부변수의 변화에 대한 연구대상 시스템의 주요 운영지표의 민감도가 분석되었는데 관로의 유지관리에 연관된 외부변수는 누수수량과 관로의 변화에는 큰 영향을 끼치나, 유수율을 비롯한 주요 운영지표에는 큰 영향을 미치지 않는 것으로 나타났다. 관로의 유지관리와 유수율과 같은 주요 운영지표 간의 관계를 보다 정확히 모형화하기 위해서는 관로의 누수 또는 사고로 인해 발생하는 사회적 비용의 발생과 그 전파 메카니즘이 모형화되어야 할 것으로 분석된다.

배관 재질 및 길이에 따른 대규모 시설원예단지용 미활용 에너지 시스템의 성능 평가 (Effects of Pipe Network Materials and Distance on Unused Energy Source System Performance for Large-scale Horticulture Facilities)

  • 이재호;윤여범;현인탁;이광호
    • KIEAE Journal
    • /
    • 제14권4호
    • /
    • pp.119-125
    • /
    • 2014
  • This study investigated the effects of pipe network materials and distance on system performance utilizing unused energy sources in large-scale horticulture facility. For this, the modeling was performed with a 100 m long and 100 m wide rectangular shaped glass house having an area of 1ha ($10,000m^2$) using EnergyPlus software. The heat sources considered were air source, geothermal heat, power plant waste heat, sea water heat, and river water. The temperature variation of the fluid with regard to pipe material and distance from the heat source and the resultant heat pump electricity consumptions were calculated. It turned out that the fluid temperature reaching the heat pump increased as the distance from the heat source increased in case of sea water and river water, which have higher temperatures than the surrounding soil, improving the heat pump efficiency. It was vice versa in case of the power plant waste heat. In addition, pipe material of PVC showed the smallest effect on the system performance variation due to the lowest thermal conductivity, compared to PB and HDPE.

MIKE SWMM모형을 이용한 도시유역 유출분석에 관한 연구 (Analysis on the Runoff of Urban Watershed using MIKE SWMM Model)

  • 김종석;최경록;안재현;문영일
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.862-866
    • /
    • 2005
  • 도시유역의 유출분석을 위하여 국내에서 많이 사용하고 있는 모형들로는 ILLUDAS, SWMM이 대표적이라고 할 수 있다. 그러나 국내의 대부분의 도시하천의 경우 합류식의 배수계통을 가지고 있어, 홍수시에 하수관거용량을 초과하는 우수량은 하천을 통해 배수가 되고 있다. 이러한 배수계통을 갖는 하천에 대하여 대상유역의 배수관망 자료 부족과 Modeling의 어려움으로 인해 도시유출모형이 아닌 HEC-HMS모형과 같은 유역추적법을 통해 유출분석이 이루어지고 있다. 또한 기존 논문에서 제시한 도시유출모형에 하도추적을 결합한 강우-유출 모의는 정확성 결여 및 번거로운 단점이 있다. 따라서 본 논문에서는 보다 안정적인 해석 모형인 MIKE SWMM 모형을 사용하여 과거 침수자료와 DEM 자료 및 수치 배수관망 자료를 통한 유역 및 배수관망 자료를 구축하고 유역에 대해서는 Runoff Block을 사용하고, 하수관거와 본류에 대해서는 Dynamic 방정식을 이용한 Extran Block을 적용하여 유출분석을 실시하고 그 결과를 기존의 방법들과 비교하여 각각의 장단점 및 적용성을 밝히고 개선방향등을 제시하고자 하였다.

  • PDF

Constructing a digital twin for estimating the response and load of a piping system subjected to seismic and arbitrary loads

  • Dongchang Kim;Gungyu Kim;Shinyong Kwag;Seunghyun Eem
    • Smart Structures and Systems
    • /
    • 제31권3호
    • /
    • pp.275-281
    • /
    • 2023
  • In recent years, technological developments have rapidly increased the number of complex structures and equipment in the industrial. Accordingly, the prognostics and health monitoring (PHM) technology has become significant. The safety assessment of industrial sites requires data obtained by installing a number of sensors in the structure. Therefore, digital twin technology, which forms the core of the Fourth Industrial Revolution, is attracting attention in the safety field. The research on digital twin technology of structures subjected to seismic loads has been conducted recently. Hence, this study proposes a digital twin system that estimates the responses and arbitrary load in real time by utilizing the minimum sensor to a pipe that receives a seismic and arbitrary load. To construct the digital twin system, a finite-element model was created considering the dynamic characteristics of the pipe system, and then updating the finite-element model. In addition, the calculation speed was improved using a finite-element model that applied the reduced-order modeling (ROM) technology to achieve real-time performance. The constructed digital twin system successfully and rapidly estimated the load and the point where the sensor was not attached. The accuracy of the constructed digital twin system was verified by comparing the response of the digital twin model with that derived by using the load estimated from the digital twin model as input in the finite-element model.

탄성 루프형 바퀴를 이용한 장 내 이동 메커니즘 (Flexible Loop Wheel Mechanism for Intestine Movement)

  • 임형준;민현진;김병규;김수현
    • 대한기계학회논문집A
    • /
    • 제26권2호
    • /
    • pp.314-321
    • /
    • 2002
  • An endoscope is usually inserted into the human body for the inspection of the gullet, stomach, and large intestine (colon) and this may cause discomfort to patients and damage to tissues during diagnostic or therapeutic procedures. This situation necessitates a self-propelling endoscope. There are many kinds of mechanism to move in a rigid pipe. However, these methods are difficult to apply directly to the endoscope. The main reason is that human intestine cannot be considered as a uniform, straight, and rigid pipe. This paper proposes a flexible loop wheel mechanism, which is adaptable to the human intestine. This mechanism is designed and fabricated by a simple modeling, and tested by an experiment. Finally, the actuator is inserted into the pig colon.