• 제목/요약/키워드: Pipe mixing method

Search Result 32, Processing Time 0.035 seconds

Numerical Analysis of the Differential Pressure Venturi-cone Flowmeter (차압식 Venturi-cone 유량계에 대한 유동해석)

  • Yoon J. Y.;Maeng J. S.;Lee J. W.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.143-148
    • /
    • 1997
  • Differential pressure Venturi cone flowmeter is an advanced flowmeter which has many advantages such as wide range of measurement, high accuracy, excellent flow turndown ratio, low headless, and short installation pipe length requirement, etc. Like other differential pressure flowmeter, Venturi cone flowmeter uses the law of energy conservation, but its shape and position make it perform better than others. The cone acts as its own flow conditioner and mixer, fully conditioning and mixing the flow prior to measurement. For the analysis, we use Reynolds-averaged Navier-Stokes equations and $k-{\omega}$ turbulence model. The equations are fully trans-formed in the computational coordinates, the pressure-velocity coupling is made through SIMPLER algorithm, and the equations are discretized using analytic solutions of the linearized equations(Finite Analytic Method). At the end of the paper, using the result of analysis, We propose a new shape of cone with the hope of drag reduction and high performance.

  • PDF

Engineering Characteristics Assessment of Rapid Set Controlled Low Strength Material for Sewer Pipe Using Excavated Soil (굴착토를 활용한 속경성 유동성 채움재의 공학적 특성 평가)

  • Kim, Young-Wook;Lee, Bong-Chun;Jung, Sang-Hwa
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.450-457
    • /
    • 2020
  • In this study, engineering characteristics such as flowability, segregation and compressive strength by age to derive fast hardening material mixing proportion using excavated soil. And based on optimal mixing proportion, field simulation experiment conducted in laboratory to examine the effectiveness of the method such as kelly ball drop test and soil penetration test for reviewing the following process. As as a result of evaluation, in case of kelly ball drop test and soil penetration test were securing the following process initiation time 3 hours after place CLSM. As results of these assessments, kelly ball drop test and soil penetration test were applicable for revewing following process in construction field besides unconfined compressive strength method.

Study on the Simulation of the 4-Stroke Cycle Spark Ignition Engines (First Paper) (4 행정 사이클 스파크 점화기관의 시뮬레이션에 관한 연구 (제1보))

  • 윤건식;우석근;서문진;신승한
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.1260-1271
    • /
    • 2001
  • The simulation program which predicts the gas behavior in a spark ignition engine has been developed and verified by the comparison with the experimental results foy the MPI engine, naturally aspirated and turbochared engines with a carburettor. First paper describes the calculations of the behavior of gas in the intake and exhaust system. The generalized method of characteristics including friction, heat transfer, area change and entropy gradients was used to analyse the pipe flow The constant-Pressure model was applied for the analysis of the flow through engine valved, and the constant-pressure perfect-mixing model was applied for the flow at manifold junction. The concept of the sudden area change was used for the muffler and catalytic convertor. Fer the plenum chamber in an MPI engine, constant-pressure model and constant-volume model were both examined. Through the comparison of predicted results with experiments, the simulation program was verified by showing good prediction of the behavior of IC engine qualitatively and quantitatively under wide range of operating conditions.

  • PDF

Numerical analysis of the differential pressure venturi-cone flowmeter (차압식 벤튜리콘 유량계에 대한 유동해석)

  • 윤준용;맹주성;이정원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.714-720
    • /
    • 1998
  • The differential pressure venturi-cone flowmeter is an advanced flowmeter which has many advantages such as wide range of measurement, high accuracy, excellent flow turn-down ratio, low headless, short installation pipe length requirement, and etc. Like other differential pressure flowmeters, the venturi-cone flowmeter uses the law of energy conservation, but its shape and position make it perform better than others. The cone acts as its own flow conditioner and mixer, fully conditioning and mixing the flow prior to measurement. For the analysis, we used Reynolds-averaged Wavier-Stokes equations and k-$\omega$ turbulence model. The equations were fully transformed into the computational domain, the pressure-velocity coupling was made through SIMPLER algorithm, and the equations were discretized using finite analytic solutions of the liberalized equations(Finite Analytic Method). To control the separation phenomenon on the cone surface, we proposed a new shape of cone, and analyzed the flowfield in the new flowmeter system, and found the improvement on the performance of the new cone flowmeter.

  • PDF

The Effect of Needle Electrode in the Static Charge Elimination Methods for Streaming-Electrification Insulating Oil (유동 대전된 절연유의 제전 방식중 침전극 삽입의 영향(II))

  • Cho, Y.K.;Kim, Y.W.;Lim, H.C.;Kim, D.S.;Shin, Y.D.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.624-626
    • /
    • 1993
  • The Electrical Charge generated by friction in flowing insulating oil can create hazadous accidents. Neutralization of static charges in the oil during transportation is an obvious method of overcoming the problem of internal electric charge. It is known that SCR(Static Charge Reducer) can neutralize much of this charge by the needle electrode and mixing it with the original charge. In our experiment, a filter to generate static charge was set just befor a measurement pipe, and streaming current from the filter to the earth $I_s$, current from the electrode to the earth $I_e$ and current from the receiving tank to the earth $I_f$ were measured in a steady state. As a result, charge density and needle electrode current increases with increasing of oil temperature. Charge elimination rate decreases with increasing of oil flow rate, and increases with increases of oil temperature. Faraday Cage current decreases with increasing of oil temperature.

  • PDF

Full Scale Tests of Concrete Filled Steel Tube Column using High Fluidity Concrete (고유동 콘크리트를 이용한 콘크리트 충전강관 기둥의 실물대 시공실험)

  • Kim Ook-Jong;Lee Do-Bum
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.222-227
    • /
    • 2001
  • Full scale construction tests of CFT(concrete filled steel tube) column to solve construction problem and to confirm quality were performed in apartment site. To improve construction efficiency, the tests has been accomplished two stages after the tests for material mixing design had been completed. In the first stage, the experimental variables were the placing methods, existence of guiding pipe, placing velocity and drop height and the height of specimen were $3.6{\cal}m$. In the second stage, Filling steel tube of 9.6m height with concrete was performed by two ways, that is, the pump-up method and the dropping method. The filled condition of the concrete and concrete strength distribution according to the column height were checked and the quality of the CFT column was confirmed.

  • PDF

A Study on Effective Removal Method of Odorant Smell in Natural Gas using Sodium Hypochlorite (차아염소산나트륨을 이용한 천연가스 부취냄새 효과적 탈취방법 연구)

  • Lim, Hyung-Duk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.154-159
    • /
    • 2018
  • Intentional releases occur frequently during maintenance in gas supplying companies, which may result in unpleasant odors, and the possible mistaken belief of a gas accident. Therefore, this study developed a chemical process for effective odorant removal in natural gas using an active chemical that is released intentionally during maintenance and inspection. To develop an effective treatment process for removing the odorant from released natural gas, the effluent concentrations of the odorant in the released gas were measured after a chemical oxidation reaction with a sodium hypochlorite solution in a compact gas scrubbing equipment newly devised in this study. The device was based on a mixed gas vent after the solution inject odorant in the gas through the energy of the venting gas. The cascade combination of a venturi pipe and mixing chamber was developed to remove the odorant effectively from the purposely-released natural gas using an oxidative reaction between the mercaptan compounds (odorant) and the sodium hypochlorite solution. On the other hand, the developed method could be applied limitedly to a relatively small gas release from a low-pressure source. Further studies will be needed to apply the developed process to a large-scale gas release from a high-pressure source.

A Study on the Simulation of Underground Acoustic Telemetry (지중 원격 음파통신 시뮬레이션 연구)

  • Shin, Younggy
    • Plant Journal
    • /
    • v.18 no.2
    • /
    • pp.41-45
    • /
    • 2022
  • The conventional communication method using mud flow pressure waves has a speed of 1-2 bps, so it takes a long time to communicate, making real-time control impossible. Although the sound wave communication method for improving the communication speed by 10 times or more has been commercialized, its use is limited due to its high price and there are not many application cases. In this study, the simulator corresponding to the facility was developed to develop performance similar to the actual test results. For simulating sound wave communication through a drill pipe, we proposed a governing equation that can simulate friction damping by mud and developed a numerical analysis model. The attenuation factor was corrected by comparing it with the attenuation rate of sound wave energy at the drilling site. The developed numerical analysis model was applied to the QPSK modulation type communication algorithm to confirm the excellent performance of the communication error rate of 0.04% in the ground. This is the communication performance under the condition that noise has not been mixed yet, and in order to apply it, the technology of reproducing the actual noise signal for mixing by securing the field noise data was established.

  • PDF

Engineering Properties of Liquefied Stabilized Soil by Contents of Humic Acid (휴믹산 함유량에 따른 유동화 처리토의 공학적 특성)

  • Han, Sang-Jae;Ahn, Dong-Wook;Park, Jea-Man;Kim, Soo-Sam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5C
    • /
    • pp.229-237
    • /
    • 2009
  • A conventional way of backfilling has used sand or in-situ soil. It not only requires substantial amount of time and cost but also makes it particularly difficult to fill the bottom part and small cracks of a pipe. To address the problem with the conventional method of compaction, liquefied stabilized soil was proposed as an alternative because it reuses in-situ soil which can ensure sand supply while adjusting flowability and strength of the soil with design of mix proportion. With an aim to identify the mixing properties of liquefied stabilized soil depending on the organic content of in-situ soil, this study conducted indoor tests of material segregation, flowability, strength, and permeability by changing humic acid content of the soil. The results revealed that material segregation and flowability increased proportionally while strength decreased with the increased amount of humic acid. In the mean time, permeability of liquefied stabilized soil wasn't affected by organic content.

Variation of abrasive feed rate with abrasive injection waterjet system process parameters (연마재 투입형 워터젯 시스템의 공정 변수에 따른 연마재 투입량 변화)

  • Joo, Gun-Wook;Oh, Tae-Min;Kim, Hak-Sung;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.2
    • /
    • pp.141-151
    • /
    • 2015
  • A new rock excavation method using an abrasive injection waterjet system has been developed to enhance the efficiency and reduce the vibration of tunnel excavation. The abrasive feed rate is an important factor for the cutting performance and the economical efficiency of waterjet-based excavation. In this study, various experiments were performed to explore the effects of major process parameters for both the abrasive feed rate and the suction pressure occurring inside the mixing chamber when the abrasives are inhaled. Experimental results reveal that the abrasive feed rate is affected by geometry parameters (abrasive pipe height, length, and tortuosity), abrasive parameters (abrasive particle size), and jet energy parameters (water pressure and water flow rate). In addition, the relation between the cutting performance and the abrasive feed rate was discussed on the basis of the results of an experimental study. The cutting performance can be maximized when the abrasive feed rate is controlled appropriately via careful management of major process parameters.