• Title/Summary/Keyword: Pipe leakage

Search Result 218, Processing Time 0.024 seconds

Water Cooling Pipe Structure for Heat-Dissipation of HEV Inverter System (HEV용 인버터의 방열을 위한 수냉식 배관구조)

  • Kim, Gyoung-Man;Woo, Byung-Guk;Lee, Yong-Hwa;Kang, Chan-Ho;Chun, Tae-Won;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.27-34
    • /
    • 2010
  • To dissipate the heat generated from the switching devices in the inverter system of HEV, the water cooling structure is proposed. The bolt type cooling structure has a problem such as water leakage for high pressure of water, therefore the proposed cooling structure applied pipe structure in the heat sink. The heat dissipation characteristics for various structures of water channel and distance between heat source and water channel was analyzed through the simulation. heat dissipation effect for two types of water cooling structures was investigated. Based on the simulation results, two types of water cooling system for 30kW inverter system of HEV were manufactured and the heat dissipation effect was verified.

Selective Corrosion of Socket Welds of Stainless Steel Pipes Under Seawater Atmosphere (해수분위기에서 스테인리스강 배관 소켓 용접부의 선택적 부식)

  • Boo, Myung-Hwan;Lee, Jang-Wook;Lee, Jong-Hoon
    • Corrosion Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.224-230
    • /
    • 2020
  • Stainless steel has excellent corrosion resistance. The drawback is that pitting occurs easily due to the concentration of chloride. In addition, corrosion of socket weld, which is structurally and chemically weaker than the other components of the pipe, occurs rapidly. Since these two phenomena overlap, pinhole leakage occurs frequently in the seawater pipe socket welds made of stainless steel at the power plants. To analyze this specific corrosion, a metallurgical analysis of the stainless steel socket welds, where the actual corrosion occurred during the power plant operation, was performed. The micro-structure and chemical composition of each socket weld were analyzed. In addition, selective corrosion of the specific micro-structure in a mixed dendrite structure comprising γ-austenite (gamma-phase iron) and δ-ferrite (iron at high temperature) was investigated based on the characteristic micro-morphology and chemical composition of the corroded area. Finally, the different corrosion stages and characteristics of socket weld corrosion are summarized.

A Failure Estimation Method of Steel Pipe Elbows under In-plane Cyclic Loading

  • Jeon, Bub-Gyu;Kim, Sung-Wan;Choi, Hyoung-Suk;Park, Dong-Uk;Kim, Nam-Sik
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.245-253
    • /
    • 2017
  • The relative displacement of a piping system installed between isolated and nonisolated structures in a severe earthquake might be larger when without a seismic isolation system. As a result of the relative displacement, the seismic risks of some components in the building could increase. The possibility of an increase in seismic risks is especially high in the crossover piping system in the buildings. Previous studies found that an elbow which could be ruptured by low-cycle ratcheting fatigue is one of the weakest elements. Fatigue curves for elbows were suggested based on component tests. However, it is hard to find a quantitative evaluation of the ultimate state of piping elbows. Generally, the energy dissipation of a solid structure can be calculated from the relation between displacement and force. Therefore, in this study, the ultimate state of the pipe elbow, normally considered as failure of the pipe elbow, is defined as leakage under in-plane cyclic loading tests, and a failure estimation method is proposed using a damage index based on energy dissipation.

Seismic Fragility of Steel Piping System Based on Pipe Size, Coupling Type, and Wall Thickness

  • Ju, Bu Seog;Gupta, Abhinav;Ryu, Yonghee
    • International journal of steel structures
    • /
    • v.18 no.4
    • /
    • pp.1200-1209
    • /
    • 2018
  • In this study, a probabilistic framework of the damage assessment of pipelines subjected to extreme hazard scenario was developed to mitigate the risk and enhance design reliability. Nonlinear 3D finite element models of T-joint systems were developed based on experimental tests with respect to leakage detection of black iron piping systems, and a damage assessment analysis of the vulnerability of their components according to nominal pipe size, coupling type, and wall thickness under seismic wave propagations was performed. The analysis results showed the 2-inch schedule 40 threaded T-joint system to be more fragile than the others with respect to the nominal pipe sizes. As for the coupling types, the data indicated that the probability of failure of the threaded T-joint coupling was significantly higher than that of the grooved type. Finally, the seismic capacity of the schedule 40 wall thickness was weaker than that of schedule 10 in the 4-inch grooved coupling, due to the difference in the prohibition of energy dissipation. Therefore, this assessment can contribute to the damage detection and financial losses due to failure of the joint piping system in a liquid pipeline, prior to the decision-making.

Defect Estimation of a Crack in Underground Pipelines by CMFL type NDT System

  • Kim, Hui Min;Yoo, Hui Ryong;Cho, Sung Ho;Kim, Dong Kyu;Koo, Sung Ja;Park, Gwan Soo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.4
    • /
    • pp.486-490
    • /
    • 2013
  • A defect which is axially oriented with small size is hard to detect in conventional system. CMFL(Cricumferential Magnetic Flus Leakage) type PIG(Pipelines Inspection Gauge) in the NDT(Nondestructive Testing), is operated to detect this defect called axially oriented cracks in the pipe. It is necessary to decompose the size and shapes of cracks for the manintenance of underground pipelines. This article is focused on the decomposing method of the size and shape of the axially oriented cracks by using inspection signal data for defect.

A Study on the Corrosion Control and Protection of 154kV Underground Pipe-type Oil Filled (POF) Cable (154kV 지중 POF 케이블의 부식방지(腐蝕防止)에 관한 연구(硏究))

  • Lee, D.I.;Kim, J.B.;Jeong, D.W.;Kim, D.K.;Lee, J.B.;Jeong, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.161-165
    • /
    • 1990
  • KEPCO has experienced eight oil leakage failures due to POF cable corrosion in the 154KV underground POF cable transmission line since the line was operated in 1976. Experimentally, We have verified that the cause of the failure is electrolytic corrosion of the cable owing to subway leakage current. For the countermeasure, We adopted the total Cathodic Protection System by the use of Victim Anode, Forced Drainage Method and Impressed Current Method with polarization cell.

  • PDF

Identification on Principle of Acoustic Wave Propagation in a Gas Duct (가스 파이프 내부의 음향 전파 특성에 관한 연구)

  • Kim, Min-Soo;Lee, Sang-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1100-1105
    • /
    • 2007
  • In the gas supply duct, the gas leakage caused by the impact of the construct equipment is serious problem. The identification of the impact position is an important issue and an engineering work. For the basic research of this problem, the principle studies for the acoustic wave propagation in a gas duct are proceeded in this paper. This principal work is based on the identification of the cut-off frequency associated with major modes of the gas duct theoretically and experimentally. The cut-off frequency is confirmed by STFT and cross-correlation function is used to identify the leakage position.

  • PDF

Defect Estimation of a Crack in Underground Pipelines by CMFL Type NDT System

  • Kim, Hui Min;Park, Gwan Soo
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2218-2223
    • /
    • 2014
  • A crack which is axially oriented with small size is hard to detect in conventional system. CMFL(Circumferential Magnetic Flux Leakage) type PIG(Pipelines Inspection Gauge) in the NDT(Nondestructive Testing), is operated to detect this defect called axially oriented cracks in the pipe. It is necessary to decompose the size and shapes of cracks for the maintenance of underground pipelines. This article is mainly focused on the decomposing method of the size and shape of the axially oriented cracks by using inspection signal data for defect.

Case Study of Oil Spills in Soil; Oil Concentration Distribution in Soil (토양에 유출된 유류의 오염도 조사에 관한 사례연구)

  • Park, Kyoohong;Park, Junboum
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.2
    • /
    • pp.31-39
    • /
    • 1997
  • Between 40,000 and 60,000 liters of light oil were spilled when an underground pipe broke at a newly constructed landfill site in coastal area, Korea. Methods were presented to examine the subsurface distribution of the contaminants in hydrocarbon-contaminated soil. As results, large quantities of oil and grease were found to have migrated horizontally at the site. Oil and grease plume at concentrations of 38-88 mg/kg was formed horizontally through silty sand with gravel fill and the vertical movement of the contaminants was thought to be limited to groundwater level between 2 and 4 m corresponding to sea water level. Right after finding the leakage area, the early action of excavation and pumping out the mixture of groundwater and oil was taken and it was proved to be very effective for preventing further contamination. Two months after the leakage, oil and grease in sea water sample near contaminated area was not detectable.

  • PDF

Development of Self-Diagnosis Function Concrete for Damage (자기손상자현 기능성 콘크리트 개발)

  • 장주영;김이성;김화중
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.198-201
    • /
    • 2003
  • The R.C Building will be superannuated as time passes. This program is generated by propagation of cracks. In order to manage such cracks, time and efforts, expense, etc. are required. In this study, glass sensors were embedding in a model beam and column and leakage of fluorescence and adhesive material was investigated. Further, currents in glass pipe were observed to find the leakage of liquid in glass pipes. Progressive cracks generated by cause the fracture of glass pipes. Therefore, the liquid become to flow and electric current stops, and the cracked part of the member can be found easily. Moreover, the adhesive delays progressive cracking system that responds in air, and the life of a structure can be made to extend. The purpose of this research is to develop of low price sensors that can perform of self-diagnosis in addition to ability of concrete repair concrete to damage.

  • PDF