• 제목/요약/키워드: Pipe Flow Analysis

검색결과 638건 처리시간 0.031초

전단간섭계를 이용한 압력용기 내부 결함 측정시 전단량 변화에 따른 오차분석 (Analysis of Error Rate in the Variations of Shearing Amount in Measuring the Internal Defect using a Shearography)

  • 홍경민;강영준;최인영;안용진;윤석범
    • 한국생산제조학회지
    • /
    • 제21권5호
    • /
    • pp.726-732
    • /
    • 2012
  • Pipe and Pressure Vessels that is used in power plant and chemical industry have many Internal Defects that is corrosion caused by the flow of fluid. These Internal Defects that have possibility of explosion are very dangerous because it can not see from the outside. This days many companys using NDT method to find an Internal Defect. Most of the NDT methods have limitations that are constraint of shape and materials. But Sheargoraphy have many advantages compared conventional NDT method. It has very fast measuring speed, non-destructive and non contacting measurement. As well as it hasn't constraint of shape and materials. As a paper on the analysis of measurement of error, the important factors were the Shearing Amount and pressure, and discovered measurement of the Internal Defect of the object by using shearography. The optimal Shearing Amount and pressure was discovered and utilized.

온실 난방을 위한 평판형 태양집열기의 열적성능 분석 (Analysis on the Thermal Performance of Flat-plate Solar Collector for Greenhouse Heating(I))

  • 서원명;윤용철;이승환;이석건
    • 한국농공학회지
    • /
    • 제40권6호
    • /
    • pp.46-56
    • /
    • 1998
  • This study was performed to investigate thermal performances of two different types of flat-plate solar collector systems; natural circulation system and forced circulation system. Conclusions obtained from this study are summarized as follows; 1) In the natural circulation system, the total heat amounts retrieved by starting recovery soon after sunrise were ranged from 10.28 to 17.20MJ/m$^2$, while the total heat amounts retrieved by starting recovery after sunset were ranged from 5.31 to 10.77MJ/m$^2$. 2) The collector efficiency in natural circulation system were ranged from 51.1% to 54.1% when the collected heat was retrieved after sunrise and were 65.8~78.0% when the collected heat was retrieved soon after sunset. 3) According to the regression analysis between fluid flow rates and fluid temperature difference at inlet and outlet of collector pipe, there was high regressive corelations with regression coefficient, r, of 0.982. 4) The collector efficiencies estimated for forced circulation system were 73.1~88.6%, and 78.4~94.8%, and 64.2%~74.5%, respectively when fluid circulation rates were 4.2 l/min, and 7.0 l/min, respectively.

  • PDF

굴삭기 IMV용 비례전자밸브의 동특성 (Dynamic Characteristics of Electro-hydraulic Proportional Valve for an Independent Metering Valve of Excavator)

  • 강창남;윤소남;정황훈;김문곤
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권2호
    • /
    • pp.46-51
    • /
    • 2018
  • Many research studies have been carried out related to saving energy and environmental pollution in the field of construction machinery. The best solution for reducing the related environmental pollution is to reduce fuel consumption by upgrading the energy efficiency of machinery used in this field. An efficiency upgrade in the field of construction machinery would mean minimizing the pressure loss in hydraulic pipe lines or achieving optimal operating conditions while responding to a load. One way to achieve this is to make an equivalent circuit, like an electrohydrostatic actuator, or to improve the spool type valve using the 4/3 way method. This study deals with an electrohydraulic proportional flow control valve. SimulationX software is used as a simulation tool for analyzing the dynamic characteristics. The analysis results, including the performance and characteristics of design parameters, are discussed and the validity of the theoretical analysis is also evaluated.

냉이온수기 냉각시스템에 관한 열유동 해석 (Thermal-flow Analysis of the Cooling System in the Medicated Water Electrolysis Apparatus)

  • 전성오;이상준;이종철;김윤제
    • 한국유체기계학회 논문집
    • /
    • 제14권3호
    • /
    • pp.33-38
    • /
    • 2011
  • Medicated water electrolysis apparatus, which electrolyzes water into acidic water and alkaline water, was in the spotlight as becoming known the effect of alkaline water. It is known as good for health as removing active oxygen in the human's body and promoting digestion. But, the customers could not get that desired water temperature because these apparatuses are directly connected with a water pipe. So, the cooling system was developed for controlling the temperature of the alkaline water. One of the typical way is to store water in water tank and control the temperature. But, in this way, storing water can be polluted impurities coming from outside. For protecting this pollution, the cooling system based on indirect heat exchange method through phase change between water and ice was developed. In this study, we have calculated efficiency of the cooling system with phase change by experiment and commercial CFD(Computational Fluid Dynamics) code, ANSYS CFX. To consider the effect of latent heat that is generated by melting ice, we have simulated two phase numerical analyses used enthalpy method and found the temperature, velocity, and ice mass distribution for calculating the efficiency of cooling. From the results of numerical analysis, we have obtained the relationship between the cooling efficiency and each design factor.

Extension of the NEAMS workbench to parallel sensitivity and uncertainty analysis of thermal hydraulic parameters using Dakota and Nek5000

  • Delchini, Marc-Olivier G.;Swiler, Laura P.;Lefebvre, Robert A.
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3449-3459
    • /
    • 2021
  • With the increasing availability of high-performance computing (HPC) platforms, uncertainty quantification (UQ) and sensitivity analyses (SA) can be efficiently leveraged to optimize design parameters of complex engineering problems using modeling and simulation tools. The workflow involved in such studies heavily relies on HPC resources and hence requires pre-processing and post-processing capabilities of large amounts of data along with remote submission capabilities. The NEAMS Workbench addresses all aspects of the workflows involved in these studies by relying on a user-friendly graphical user interface and a python application program interface. This paper highlights the NEAMS Workbench capabilities by presenting a semiautomated coupling scheme between Dakota and any given package integrated with the NEAMS Workbench, yielding a simplified workflow for users. This new capability is demonstrated by running a SA of a turbulent flow in a pipe using the open-source Nek5000 CFD code. A total of 54 jobs were run on a HPC platform using the remote capabilities of the NEAMS Workbench. The results demonstrate that the semiautomated coupling scheme involving Dakota can be efficiently used for UQ and SA while keeping scripting tasks to a minimum for users. All input and output files used in this work are available in https://code.ornl.gov/neams-workbench/dakota-nek5000-study.

Effect analysis of ISLOCA pathways on fission product release at Westinghouse 2-loop PWR using MELCOR

  • Kim, Seungwoo;Park, Yerim;Jin, Youngho;Kim, Dong Ha;Jae, Moosung
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.2878-2887
    • /
    • 2021
  • As the amount of fission product released from ISLOCA was overestimated because of conservative assumptions in the past, several studies have been recently conducted to evaluate the actual release amount. Among several pathways for the ISLOCA, most studies were focused on the pathway with the highest possibility. However, different ISLOCA pathways may have different fission product release characteristics. In this study, fission product behavior was analyzed for various pathways at the Westinghouse two-loop plant using MELCOR. Four pathways are considered: the pipes from a cold leg, from a downcomer, from a hot leg to the outlet of RHR heat exchanger, and the pipe from the hot leg to the inlet of RHR pump (Pathway 1-4). According to the analysis results, cladding fails at around 2.5 h in Pathways 1 and 2, and on the other hand, about 3.3 h in Pathways 3 and 4 because the ISLOCA pathways affect the safety injection flow path. While the release amount of cesium and iodine ranges between 20 and 26% in Pathways 1 to 3, Pathway 4 allows only 5% to the environment because the break location is submerged. Also, as more than 90% of cesium released to the environment passes through the personnel door, reinforcing the pressure capacity of the doors would be a significant factor in the accident management of the ISLOCA.

1D-2D 통합 도시 침수 해석 모형을 이용한 침수 원인 분석에 관한 연구 (Simulation and analysis of urban inundation using the integrated 1D-2D urban flood model)

  • 이승수;노성진;장철희;이동섭
    • 한국수자원학회논문집
    • /
    • 제50권4호
    • /
    • pp.263-275
    • /
    • 2017
  • 고정확도의 도시침수 모의를 위해서는 물리적 개념에 기반한 통합적 수치해석이 필요하다. 본 연구에서는 Lee et al. (2015)이 개발한 1차원 하수관망, 2차원 범람 모형의 국내 적용성을 검토하고, 과거 도시 홍수 사상의 침수 원인 분석을 수행하였다. 본 모형은 이중배수 개념에 기반하여 멘홀 대신 집수구를 지표면과 하수관망 사이의 교환유량 산정 지점으로 이용하므로 보다 실제와 유사하게 침수 과정을 모의할 수 있을 뿐 아니라 지표면 범람 해석시 건물에 의한 차단 효과를 고려할 수 있다. 개발된 모형의 적용성은 서울 사당 유역에서 발생한 침수 사상에 대해서 재현 모의를 통해 검증하였다. 적용 결과, 본 연구에서 개발된 모형은 실제 침수 피해 영역을 실제와 유사하게 모의 하였을 뿐만 아니라 침수 원인을 보다 자세히 분석할 수 있는 장점을 보여주었다.

수주지열정의 지하수 유동 및 지열 이동 예측을 위한 수치 모델링 기법 개발 (Development of a Numerical Modeling Technique for Predicting Groundwater flow and Heat Transport in a Standing Column Well)

  • 박성민;황기섭;문종필;김중휘
    • 지질공학
    • /
    • 제26권4호
    • /
    • pp.461-471
    • /
    • 2016
  • 수주지열정의 지하수 유동 및 지열 이동 현상을 모사할 수 있는 수치 모델링 기법을 제시하기 위하여 열-수리학적 모델인 TOUGH2를 기반으로 한 모듈을 개발하였고 두 유형의 수주지열정에서의 냉방 및 난방 운영을 수치 모의하였다. 수치 모델링 결과들은 수주지열정의 냉난방 운영이 주변 지층 및 지하수와의 열교환 및 유체 혼합에 크게 영향을 받으며, 특히 PVC 또는 PE 파이프 내부와 수주지열정 내부에서 서로 반대방향으로 유동하는 유입수와 유출수 간의 열교환이 중요한 요소임을 보여준다. 또한 본 연구에서 개발 및 제안된 수치 모델링 기법이 수주지열정의 내부 구조 및 유체 유동과 열 이동 현상을 합리적으로 모사할 수 있음을 보여준다. 이러한 수치 모델링 기법은 수주지열정의 설계, 시공 및 운영 단계에서 열교환 성능을 정량적으로 분석할 때 유용하게 활용될 수 있을 것으로 기대된다.

Performance Analysis of Water-Water Heat Pump System of 100 kW Scale for Cooling Agricultural Facilities

  • Kang, Youn Ku;Ryou, Young Sun;Jang, Jae Kyung;Kim, Young Hwa;Kim, Jong Goo;Kang, Geum Chun
    • Journal of Biosystems Engineering
    • /
    • 제39권1호
    • /
    • pp.34-38
    • /
    • 2014
  • Purpose: In this study, the performance of cooling system with the water-water heat pump system of 100kW scale made for cooling agricultural facilities, especially for horticultural facilities, was analyzed. It was intended to suggest performance criteria and performance improvement for the effective cooling system. Methods: The measuring instruments consisted of two flow meters, a power meter and thermocouples. An ultrasonic and a magnetic flow meter measured the flow rate of the water, which was equivalent to heat transfer fluid. The power meter measured electric power in kW consumed by the heat pump system. T-type thermocouples measured the temperature of each part of the heat pump system. All of measuring instruments were connected to the recorder to store all the data. Results: When the water temperature supplied into the evaporator of the heat pump system was over $20^{\circ}C$, the cooling Coefficient Of Performance(COP) of the system was higher than 3.0. As the water temperature supplied into the evaporator, gradually, lowered, the cooling COP, also, decreased, linearly. Especially, when the water temperature supplied into the evaporator was lower than $15^{\circ}C$, the cooling COP was lower below 2.5. Conclusions: In order to maintain the cooling COP higher than 3.0, we suggest that the water temperature supplied into evaporator from the thermal storage tank should be maintained above $20^{\circ}C$. Also, stratification in the thermal storage tank should be formed well and the circulating pumps and the pipe lines should be arranged in order for the relative low-temperature water to be stored in the lower part of the thermal storage tank.

원형바닥젵의 유속구조 해석 (Analysis of Velocity Structure of Round Wall Jet)

  • 김대근;서일원
    • 한국수자원학회논문집
    • /
    • 제30권5호
    • /
    • pp.467-475
    • /
    • 1997
  • 본 연구에서는 실험개수로에 온수방류용 방류규가 있는 방파제의 모형을 설피하여 바닥\ulcorner의 유속분포를 측정하였다. 또한 3차원의 모형인 Fluent 모형을 이용하여 방파제의 방류구로부터 배출된 바닥젵의 유속구조를 수치모의하여 실험결과와 비교.검증하였으며 흐름특성을 규명하였다. 바닥젵은 자유젵에 비하여 흐름의 확립구간이 짧았으며, 종방향거리에 대한 젵 중앙유속의 감쇠율이 자유젵보다 크게 나타나고 있음이 밝혀졌다. 단순젵과 부력젵의 젵 중앙선에서의 종방향유속을 비교한 결과, 방류구 근처에서는 부력\ulcorner의 유속이 크게 발생하나 x/lQ가 15보다 큰 구간에는 도리어 작게 된다. 종방향유속의 연직분포를 비교한 결고, 방류구로부터 멀어질수록 저층에서는 단순젵의 유속이 크게 나타나며 상충에서는 단순젵의 부의 유속이 크게 나타나고 있음이 밝혀졌다. 또한 부력젵의 경우 자유수면에서의 유속의 분리가 단순젵보다 방류구로부터 가까운 거리에서 발생한다. 부력젵의 연직방향으로의 폭은 단순젵의 폭보다 빨리 확장된다.

  • PDF