• Title/Summary/Keyword: Pin Screw

Search Result 37, Processing Time 0.028 seconds

A Study on Quality Management Improvement of Used Pipe Support(V2) (재사용 파이프서포트(V2)의 품질관리 향상에 관한 연구)

  • Park, Jongkeun;Choi, Myeongki
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.36-41
    • /
    • 2019
  • As the prefabricated shoring system structure, which is a temporary structure, is often collapsed due to various reasons during concrete pouring, and directly affects not only the safety of the workers but also the quality of the final building, it is necessary to ensure the safety. It is considered that the pipe supports which are widely used as the prefabricated shoring materials in the construction site do not satisfy the performance criteria in many cases. Therefore, this study investigated the detailed conditions for satisfying the performance criteria and suggested the factors for improving the quality control level in order to prevent collapse accidents due to pipe supports reused at the construction site, As the results of test in order to understand the effect of the pipe supports (V2), which are being reused in the field, on the performance by factor, the performance was evaluated to be high in case of the small female screw clearance and the supporting pin with 12mm in diameter or larger.

Internal Fixation of Long Bone Fractures in 6 Calves (송아지에서 발생한 긴뼈골절의 내고정 치료 6례)

  • Park, Jin-Uk;Cho, Ki-Rae;Kim, Joong-Hyun;Choi, Seok-Hwa;Kim, Gon-Hyung
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.658-662
    • /
    • 2007
  • The simple and easy treatment with cast or splint has been applied to stabilize long bone fractures in farm animals. Applying cast or splint is relatively easier than surgical fixation and may temporarily stabilize fracture site. However, the internal fixation provides strong stabilization and early recovery of limb function. In this report, we describe six cases of limb fractures in calves repaired by internal fixation. Fracture sites are various and affected ages are between 1 day and several months old. In some cases, patients were treated with cast or splint before admitting to Veterinary Medical Center. In these patients, regardless of initial treatment fractures were not immobilized. Consequently we decided to treat these patients with open reduction and internal fixation. The fracture repair with implants(bone plate, screw, cerclage wire, and intramedullary pin) were effective and satisfactory in calves which had been failed by application of cast. Although the cost of orthopedic treatment in farm animal is one of the most important considerations from the practical point of view, internal fixation has many benefits in newborn and young calves. And simplicity of postoperative management is also practically significant benefit expected from infernal fixation In conclusion, we suggest that internal fixation will produce better result than external coaptation in calve.

A Technique for Assist in Positioning the Proximal Segment during Open Reduction of a Fractured Mandibular Condyle (하악 과두 골절의 개방 정복 시 근위 골편의 수복법)

  • Kim, Myung Good
    • Archives of Plastic Surgery
    • /
    • v.33 no.6
    • /
    • pp.792-796
    • /
    • 2006
  • Purpose: After exposure of fracture site, the proximal segment must be reduced to their preinjury position for open reduction of fractured mandibular condyle. We examined the use of inter-maxillary fixation screws or titanium screws tied with stainless steel wire to assist in positioning of proximal segment. Since it enables to make a relatively small preauricular incision by not disturbing the operative field like Moule pin, we can reduce the danger of injury to the facial nerve. Methods: A preauricular approach was used for exposure, reduction, and rigid fixation in 4 cases of mandibular condylar fractures. Inter-maxillary fixation screws or titanium screws tied with stainless steel wire were used to assist in aligning proximal segment. The joints were submitted to functional exercises and postoperative radiologic and clinical follow-ups were performed. Results: No facial nerve lesions were found in all 4 cases. Radiologic follow-up showed correct reduction and fixation in all 4 cases. Clinical follow-up showed an initial limitation, but normal morbility of the condyle was achieved within 4 months after the operation, with a maximum mouth opening of $34.1{\pm}5.2mm$ after 12 months. There found no occlusal disturbances, no trismus, no lateral deviations of the mandible. Conclusion: By using Inter-maxillary fixation screws tied with stainless steel wire, it was shown that reducing the proximal segment to their preinjury position is easy to perform and it enables us to make a minimal dissection below preauricular skin incision to avoid facial nerve injury.

Effects of Intramedullary K-wire Insertion on Femoral Lengthening in Canine with Monolateral External Fixator (단측성 외고정 기구를 이용한 개의 대퇴골 신연에 있어서 골수강내 K-강선 삽입의 효과)

  • Hwang, Jae-Min;Kim, Young-Ki;Chin, Hee-Tec;Seok, Seong-Hoon;Lee, Hee-Chun;Koh, Phil-Ok;Chang, Hong-Hee;Lee, Hyo-Jong;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.23 no.3
    • /
    • pp.291-299
    • /
    • 2006
  • During long bone lengthening, there are many disadvantages including axial deviation, malalignment and re-fracture which are commonly encountered inspite of its proven abilities. To study the effects of intramedullary K-wire application on the lengthening of long bone, ten skeletally mature mongrel dogs were separated into two groups(Group I, II). Right femurs of group I(5 dogs) were fixed with only monolateral external fixator after subperiosteal osteotomy. Right femurs of group II(5 dogs) were fixed with mono lateral external fixator and intramedullary K-wire after subperiosteal osteotomy. Lengthening was started at 7 days after the surgery with the rate of 0.5 mm per day for 5 weeks and the dogs were sacrificed after 15 weeks postoperatively to examine histologic differences and evaluate bone mineral density. Radiographic examination at an interval of two weeks was done to evaluate the type of callus formed and to analyze complications including instability of external skeletal fixation and axial deviation. Bone mineral density at the lengthened area and contralateral nonlengthened area were measured using quantitative computerized tomography. Histological examination of regenerated bone was performed using Masson's trichrome stain method. The radiographs demonstrated poor callus formation, higher incidence of axial deviation and screw loosening in the group I compared to the group II. The bone mineral density at the lengthened area in the group II was higher than that of the group I(P<0.05). Histological examination showed that the new bone trabeculae in the group II were greater than that of the group I. In conclusion, the combination of monolateral external fixator and intramedullary K-wire can prevent pin loosening, axial deviation and reduce healing period in dogs.

Tibiotalocalcaneal Arthrodesis Using Ipsilateral Distal Fibula Buttress (동측 원위 비골 지주를 이용한 경-거-종골 관절 유합술)

  • Cho, Se-Hyun;Lee, Jung-Su;Jeong, Seon-Taek;Park, Hyung-Bin;Hwang, Sun-Chul;Jeong, Jae-Hyon;Cha, Min-Suok
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.2
    • /
    • pp.213-217
    • /
    • 2006
  • Purpose: To evaluate the clinical and radiological results of tibio-talo-calcaneal arthrodesis using ipsilateral distal fibula buttress which had advantages of extended operative field and release of contracted soft tissue. Materials and Methods: We retrospectively reviewed 4 postraumatic compartment syndrome, 2 residual poliomyelitis, 1 posttraumatic osteoarthritis with subtalar joint infection and 1 posttarumatic sciatic nerve palsy patients who underwent a tibio-talo-calcaneal arthrodesis from April, 1996 to March, 2002. Each of the cases was notable for a severe rigid equinovarus, persistent pus drainage of calcaneal area and paralytic foot. The mean duration of follow up was 18 months (range, $13{\sim}42$ months). The pain, function and alignment were evaluated by the modified ankle hindfoot scale of the American Orthopaedic Foot and Ankle Society (AOFAS) and patients satisfaction clinically. The radiological union were evaluated by plain AP and lateral radiographs. Results: The AOFAS score improved from 58 points (range, $47{\sim}78$) preoperatively to 82 (range, $60{\sim}89$) postoperatively. Patents satisfaction checked at 12 months after operation had favorable results (excellent and good 80%). Union rate was 100% radiographically and the mean duration of union was 12.5 weeks (range $8{\sim}22$ weeks). There was 2 cases of superficial pin tract infection and one protrusion of screw. Conclusion: Tibio-talo-calcaneal arthrodesis using ipsilateral distal fibula buttress was good modality of arthrodesis which provides wide operative field and release of contracted soft tissue in some cases of contracted foot.

  • PDF

Clinical Results of Arthroscopic Anterior Cruciate Ligament Reconstruction using Hamstring Tendon (슬괵건을 이용한 관절경적 전방십자인대 재건술)

  • Song, Eun-Kyoo;Seo, Hyoung-Yeon;Lee, Geun-Bae;Yoon, Taek-Rim;Shim, Sang-Don
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.1
    • /
    • pp.17-23
    • /
    • 1999
  • Purpose : We intend to review clinical results after Anterior cruciate ligament(ACL) reconstruction using hamstring tendon arthroscopically. Materials & Methods : Sixty two patients who had underwent arthroscopic ACL reconstruction using hamstring tendon from Mar. 1996 to Mar. 1997 were reviewed. The average follow-up was 16 months and average age at operation was 27 years old. Clinical results were evaluated with physical examination, Lysholm Knee score and instrumented anterior laxity test with Telos Results : The average preoperative Lysholm knee score was 57.0 and postoperative average of that was 91.8. All cases of 62 patients had normal range of motion of knee and were able to walk with no problems at follow-up. On the Lachmann test, there were mild(+) instability in 24 cases, moderate(++) in 24 cases, severe(+++) in 14 cases preoperatively and 48 cases were converted to negative, 14 cases mild postoperatively. On instrumented anterior laxity test with Telos, difference between normal and affected knee on 20 lb which was 13.4mm preoperatively was decreased to 4.7mm at follow-up and anterior stability was regained(P<0.05). Parapatellar complications such as crepitus in 18 cases(29.5%), atrophy of quadriceps in 23 cases(36.5%) were observed. There were 2 cases of inaccuracy of guide pin of semifix screw intraoperatively and 3 cases of malposition of semifix screw postoperatively. Conclusion : ACL reconstruction using hamstring tendon seems to be a effective procedure to establish the stability of knee joint but is technically demanding procedure and leaves some parapatellar complications.

  • PDF

Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report (구순구개열 환자에서 Locator® 유지장치가 장착된 milled titanium bar를 이용한 가철성 임플란트 피개 국소의치의 보철수복증례)

  • Yang, Sang-Hyun;Kim, Kyoung-A;Kim, Ja-Yeong;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.207-214
    • /
    • 2015
  • Due to the limitations of conventional removable partial denture prostheses to treat a cleft lip & palate patient who shows scar tissue on upper lip, excessive absorption of the maxillary residual alveolar ridge, and class III malocclusion with narrow palate and undergrowth of the maxilla, 4 implants were placed on the maxillary edentulous region and a maxillary removable implant-supported partial denture was planned using a CAD/CAM milled titanium bar. Unlike metal or gold casting technique which has shrinkage after the molding, CAD/CAM milled titanium bar is highly-precise, economical and lightweight. In practice, however, it is very hard to obtain accurate friction-fit from the milled bar and reduction in retention can occur due to repetitive insertion and removal of the denture. Various auxiliary retention systems (e.g. $ERA^{(R)}$, $CEKA^{(R)}$, magnetics, $Locator^{(R)}$ attachment), in order to deal with these problems, can be used to obtain additional retention, cost-effectiveness and ease of replacement. Out of diverse auxiliary attachments, $Locator^{(R)}$ has characteristics that are dual retentive, minimal in vertical height and convenient of attachment replacement. Drill and tapping method is simple and the replacement of the metal female part of $Locator^{(R)}$ attachment is convenient. In this case, the $Locator^{(R)}$ attachment is connected to the milled titanium bar fabricated by CAD/CAM, using the drill and tapping technique. Afterward, screw holes were formed and 3 $Locator^{(R)}$ attachments were secured with 20 Ncm holding force for additional retention. Following this procedure, satisfactory results were obtained in terms of aesthetic facial form, masticatory function and denture retention, and I hereby report this case.