• Title/Summary/Keyword: Pilot point

Search Result 254, Processing Time 0.028 seconds

A Study on the Ignition Distance from a Leakage Point of the LP Gas Pipe (LP 가스 배관의 누출부로부터 점화가능 거리에 관한 연구)

  • Ryou, Young-Don;Kim, Young-Gu;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.70-76
    • /
    • 2017
  • The standards related to the "Urban Gas Business Act" and the "Safety Control and Business Regulation of Liquefied Petroleum Gas Act" prescribe the separation distance between gas piping joint excluding welded joints and electric equipments(electric switch, watt meter, breaker, connector, etc). The "Korea Electro technical Regulation" also prescribes the distance between gas piping joints and electric equipments in accordance with the gas related standards. In case of the standards related to the "Urban Gas Business Act", the distance criteria stipulated in the standard of supplying facilities are different from those stipulated in the standard of using facilities. In this study, we have conducted pilot test on the possible ignition distance from the piping joint when LP gas is leaked from the point. We have also examined the adequacy of current standards on the separation distance between gas piping joint and electric equipments. As a result of the tests, we have found that ignition is able to occur at a distance of 30 cm as stipulated in the current standards or more when LP gas is leaked from the joint of the pipe. Therefore, we have made a decision that the criteria for separation distance between gas piping joint and electric equipment specified in the current standards related to the "Urban Gas Business Act" and the "Safety Control and Business Regulation of Liquefied Petroleum Gas Act" is appropriate.

A pilot study on measuring the human cortisol using an electronic device (전자소자를 이용한 인간 감성지표 코티졸 검출에 관한 기초연구)

  • Lee, Hee-Jo;Lee, Jung-Hyun;Hwang, Yoo-Sun;Jung, Hyo-Il
    • Science of Emotion and Sensibility
    • /
    • v.14 no.4
    • /
    • pp.531-536
    • /
    • 2011
  • The precise measurement of human emotion is of pivotal importance in the field of emotion science. Based on the perspective of psychoneuroimmunoendocrinology, human emotion is now considered to be measurable by body fluid. The biological molecule cortisol, which is known for the stress hormone, has been widely investigated to help researchers to estimate the stress loaded on human body. Until now, several measurement techniques such as High Performance Liquid Chromatography (HPLC), fluorometric assay, and reverse phase chromatography have been developed. However, since these measurements are expensive, take relatively long time for an operation, and they are not portable, they are not appropriate for POCT (point of care testing). In this paper we demonstrate the performance of a miniaturized-microwave resonant device in the measurement of cortisol. Our method has many advantages in that it requires a small volume of sample, has fast response time, is easy to operate and needs no labeling process. Besides, it will shed a light on the measurement techniques for emotion science.

  • PDF

Costing of a State-Wide Population Based Cancer Awareness and Early Detection Campaign in a 2.67 Million Population of Punjab State in Northern India

  • Thakur, JS;Prinja, Shankar;Jeet, Gursimer;Bhatnagar, Nidhi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.2
    • /
    • pp.791-797
    • /
    • 2016
  • Background: Punjab state is particularly reporting a rising burden of cancer. A 'door to door cancer awareness and early detection campaign' was therefore launched in the Punjab covering about 2.67 million population, wherein after initial training accredited social health activists (ASHAs) and other health staff conducted a survey for early detection of cancer cases based on a twelve point clinical algorithm. Objective: To ascertain unit cost for undertaking a population-based cancer awareness and early detection campaign. Materials and Methods: Data were collected using bottom-up costing methods. Full economic costs of implementing the campaign from the health system perspective were calculated. Options to meet the likely demand for project activities were further evaluated to examine their worth from the point of view of long-term sustainability. Results: The campaign covered 97% of the state population. A total of 24,659 cases were suspected to have cancer and were referred to health facilities. At the state level, incidence and prevalence of cancer were found to be 90 and 216 per 100,000, respectively. Full economic cost of implementing the campaign in pilot district was USD 117,524. However, the financial cost was approximately USD 6,301. Start-up phase of campaign was more resource intensive (63% of total) than the implementation phase. The economic cost per person contacted and suspected by clinical algorithm was found to be USD 0.20 and USD 40 respectively. Cost per confirmed case under the campaign was 7,043 USD. Conclusions: The campaign was able to screen a reasonably large population. High to high economic cost points towards the fact that the opportunity cost of campaign put a significant burden on health system and other programs. However, generating awareness and early detection strategy adopted in this campaign seems promising in light of fact that organized screening is not in place in India and in many developing countries.

A Pilot Study of Acupuncture Treatment for the Osteoarthritis of the Knee Joint on the EBM(Evidence Basement Medicine) (근거중심의학에 근거한 퇴행성 슬관절염에 관한 침치료 임상선행연구)

  • Lim, Jeong-A;Lee, Jong-Deok;Lee, Sang-Kwan;Lee, Sung-Young;Moon, Hyung-Cheol;Choi, Sun-Mi;Chung, Young-Hae;Kim, Sung-Chul
    • Journal of Acupuncture Research
    • /
    • v.23 no.1
    • /
    • pp.187-215
    • /
    • 2006
  • Objectives : To determine whether the pragmatic acupuncture treatment provides more effective pain relief than treatment using the same acupuncture point to the all patients. Methods : We randomly allocated participants to treatment group 1 and 2. The group 1 is the pragmatic treatment group and the group 2 is using the same acupuncture point to the all patients. Primary outcomes were measured by the Western Ontario and McMaster Universities Osteoarthritis index(WOMAC) pain and function scores at 4, 8, and 14 weeks. Secondary outcomes were measured by 100mm VAS(Visual Analog Scale), ROM(Range of Motion) using Goniometer, and pain threshold using pressure algometer. Results : When patients were extension of the knee, they were statistically significant in improvement of the ROM in 14 weeks. Whole body condition and pain rate through VAS measurement were improved significantly in 14 weeks. Also pain score and function score of WOMAC were improved significantly in 14 weeks. We could get difference in pain score of two acupuncture groups significantly in 14 weeks. But we could not get difference in whole score of two acupuncture groups significantly. Local temperature using T.C thermometer was changed significantly in 14 weeks. But we could not get difference in whole score of two acupuncture groups significantly. Excluding above item, DITI, pain threshold, and ROM of the knee flexion were no difference in before and after treatment.

  • PDF

Endoscopic Findings in a Mass Screening Program for Gastric Cancer in a High Risk Region - Guilan Province of Iran

  • Mansour-Ghanaei, Fariborz;Sokhanvar, Homayoon;Joukar, Farahnaz;Shafaghi, Afshin;Yousefi-Mashhour, Mahmud;Valeshabad, Ali Kord;Fakhrieh, Saba;Aminian, Keyvan;Ghorbani, Kambiz;Taherzadeh, Zahra;Sheykhian, Mohammad Reza;Rajpout, Yaghoub;Mehrvarz, Alireza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.4
    • /
    • pp.1407-1412
    • /
    • 2012
  • Background & Objectives: Gastric cancer is a leading cause of cancer-related deaths in both sexes in Iran. This study was designed to assess upper GI endoscopic findings among people > 50 years targeted in a mass screening program in a hot-point region. Methods: Based on the pilot results in Guilan Cancer Registry study (GCRS), one of the high point regions for GC-Lashtenesha- was selected. The target population was called mainly using two methods: in rural regions, by house-house direct referral and in urban areas using public media. Upper GI endoscopy was performed by trained endoscopists. All participants underwent biopsies for rapid urea test (RUT) from the antrum and also further biopsies from five defined points of stomach for detection of precancerous lesions. In cases of visible gross lesions, more diagnostic biopsies were taken and submitted for histopathologic evaluation. Results: Of 1,394 initial participants, finally 1,382 persons (702 women, 680 men) with a mean age of $61.7{\pm}9.0$ years (range: 50-87 years) underwent upper GI endoscopy. H. pylori infection based on the RUT was positive in 66.6%. Gastric adenocarcinoma and squamous cell carcinoma of esophagus were detected in seven (0.5%) and one (0.07%) persons, respectively. A remarkable proportion of studied participants were found to have esophageal hiatal hernia (38.4%). Asymptomatic gastric masses found in 1.1% (15) of cases which were mostly located in antrum (33.3%), cardia (20.0%) and prepyloric area (20.0%). Gastric and duodenal ulcers were found in 5.9% (82) and 6.9% (96) of the screened population. Conclusion: Upper endoscopy screening is an effective technique for early detection of GC especially in high risk populations. Further studies are required to evaluate cost effectiveness, cost benefit and mortality and morbidity of this method among high and moderate risk population before recommending this method for the GC surveillance program at the national level.

Development of a Sustainable First Flush Management System for Urban Stream Water Quality Management (도시 하천 수질 관리를 위한 지속가능 초기 강우 오염 관리 시스템의 개발)

  • Seo, Dongil;Lee, Tongeun;Kim, Jaeyoung;Koo, Youngmin
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.4
    • /
    • pp.247-255
    • /
    • 2016
  • Non-point pollutants from surface runoff during rainfall exert adverse effects on urban river water quality management. In particular, the first flush effect during the initial phase of rainfall can deliver significant amounts of pollutant loads to surface waters with extremely high concentrations. In this study, a sustainable first flush effect management system was developed by using settling and filtration that require no additional power or chemicals. A pilot scale experiment has shown that the removal of total suspended solid (TSS), total nitrogen (TN) and total phosphorus (TP) are in ranges of 84 - 95%, 31 - 46%, and 42 - 86%, respectively. An Integrated Stormwater Runoff Management System (ISTORMS) was also developed to efficiently manage the developed system by linking weather forecast, flow rate and water quality modeling of surface runoff and automatic monitoring systems in fields and in the system. This study can provide effective solutions for the management of urban river in terms of both quantity and quality.

The Relationship Between Self-Concept and Self-Care Activities of the Cerebral Palsied Adolescents (뇌성마비 청소년의 자아개념과 자가간호수행의 관계)

  • Hong, Hee-Sook;Lee, Myung-Hwa
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.4 no.1
    • /
    • pp.31-45
    • /
    • 2001
  • The purpose of this study was to investigate the relationship between self-concept and self-care activities of the cerebral palsied adolescents and to gain the baseline data for development of effective rehabilitation nursing intervention program of the cerebral palsied adolescents. The design of this study was a descriptive correlational study. The subjects of the study were 160 cerebral palsied adolescents attending at special schools located in Seoul and Kyonggi and rehabilitation centers located in Seoul, Kyonggi and Kyongnam province. The data was collected from May 20 to July 20, 2000. The instrument used for this study were the self-concept scale(50items 4point scale) and self-care activities scale(29items 4point scale). Self-Concept Scale had developed by Fitt(1965), which was standardized by Chung(1968) and modified by Kim(1984). Self-Care Activities Scale developed by the researcher through out the consulting of expert and pilot study on the basis of ADL check list developed by Kang(1984) and LDSQ-3(Lambeth Disability Screening Questionnair-3) developed by Na et al. (1995). The data was analyzed by the SPSS/PC+program using frequency, percentage, mean, standard deviation, t-test, ANOVA & Scheffe test and Pearson's correlation coefficient. The results of this study were as follows; 1. The mean score of self-concept was $138.55{\pm}17.20$(range: 50-100), which the item mean score was $2.77{\pm}0.34$(range: 1-4). The score of subarea of the self-concept was the highest score in family self ($3.01{\pm}0.54$) and the lowest score in physical self ($2.52{\pm}0.42$). 2. The mean score of self-care activities was $95.25{\pm}21.69$ (range: 29-116), which the item mean score was $3.28{\pm}0.75$ (range: 1-4). The score of subarea of the self-care activities was the highest score in feeding($3.75{\pm}0.59$) and the lowest score in walking($2.64{\pm}1.21$). 3. There were statistically significant difference in the score of self-concept according to the age (F=3.24, P=.04), the grads (F=4.36, P=.01), and types of cerebral palsy (F=2.42, P=.03). 4. There were statistically significant difference in the score of self-care activities according to the age (F=8.29, P=.00), the grads (F=16.05, P=.00), types of living place (F=6.46, P=.00), types of cerebral palsy (F=48.92, P=.00), whether or not receiving a rehabilitation therapy (t=-3.64, P=.00), whether or not receiving a vocational training (t=2.14, P=.03), and whether or not using a device (t=-7.42, P=.00). 5. There was not significant correlation between self-concept and self-care activities (r=.081, P=.311).

  • PDF

Detecting Peripheral Nerves in the Elbow using Three-Dimensional Diffusion-Weighted PSIF Sequences: a Feasibility Pilot Study

  • Na, Domin;Ryu, Jaeil;Hong, Suk-Joo;Hong, Sun Hwa;Yoon, Min A;Ahn, Kyung-Sik;Kang, Chang Ho;Kim, Baek Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.2
    • /
    • pp.81-87
    • /
    • 2016
  • Purpose: To analyze the feasibility of three-dimensional (3D) diffusion-weighted (DW) PSIF (reversed FISP [fast imaging with steady-state free precession]) sequence in order to evaluate peripheral nerves in the elbow. Materials and Methods: Ten normal, asymptomatic volunteers were enrolled (6 men, 4 women, mean age 27.9 years). The following sequences of magnetic resonance images (MRI) of the elbow were obtained using a 3.0-T machine: 3D DW PSIF, 3D T2 SPACE (sampling perfection with application optimized contrasts using different flip angle evolution) with SPAIR (spectral adiabatic inversion recovery) and 2D T2 TSE (turbo spin echo) with modified Dixon (m-Dixon) sequence. Two observers used a 5-point grading system to analyze the image quality of the ulnar, median, and radial nerves. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of each nerve were measured. We compared 3D DW PSIF images with other sequences using the Wilcoxon-signed rank test and Friedman test. Inter-observer agreement was measured using intraclass correlation coefficient (ICC) analysis. Results: The mean 5-point scores of radial, median, and ulnar nerves in 3D DW PSIF (3.9/4.2/4.5, respectively) were higher than those in 3D T2 SPACE SPAIR (1.9/2.8/2.8) and 2D T2 TSE m-Dixon (1.7/2.8/2.9) sequences (P < 0.05). The mean SNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR, but there was no difference between 3D DW PSIF and 2D T2 TSE m-Dixon in all of the three nerves. The mean CNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR and 2D T2 TSE m-Dixon in the median and ulnar nerves, but no difference among the three sequences in the radial nerve. Conclusion: The three-dimensional DW PSIF sequence may be feasible to evaluate the peripheral nerves around the elbow in MR imaging. However, further optimization of the image quality (SNR, CNR) is required.

Adjustable Ghajar Guide Technique for Accurate Placement of Ventricular Catheters : A Pilot Study

  • Yoon, Sang-Youl;Kwak, Youngseok;Park, Jaechan
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.604-609
    • /
    • 2017
  • Objective : An adjustable Ghajar guide is presented to improve the accuracy of the original Ghajar guide technique. The accuracy of the adjustable Ghajar guide technique is also investigated. Methods : The coronal adjustment angle from the orthogonal catheter trajectory at Kocher's point is determined based on coronal head images using an electronic picture archiving and communication system. For the adjustable Ghajar guide, a protractor is mounted on a C-shaped basal plate that is placed in contact with the margin of a burrhole, keeping the central $0^{\circ}$ line of the protractor orthogonal to the calvarial surface. A catheter guide, which is moved along the protractor and fixed at the pre-determined adjustment angle, is then used to guide the ventricular catheter into the frontal horn adjacent to the foramen of Monro. The adjustable Ghajar guide technique was applied to 20 patients, while a freehand technique based on the surface anatomy of the head was applied to another 47 patients. The accuracy of the ventricular catheter placement was then evaluated using postoperative computed tomography scans. Results : For the adjustable Ghajar guide technique (AGT) patients, the bicaudate index ranged from 0.23 to 0.33 ($mean{\pm}standard$ deviation [SD] : $0.27{\pm}0.03$) and the adjustment angle ranged from $0^{\circ}$ to $10^{\circ}$ ($mean{\pm}SD:5.2^{\circ}{\pm}3.2^{\circ}$). All the AGT patients experienced successful cerebrospinal fluid diversion with only one pass of the catheter. Optimal placement of the ventricular catheter in the ipsilateral frontal horn approximating the foramen of Monro (grade 1) was achieved in 19 patients (95.0%), while a suboptimal trajectory into a lateral corner of the frontal horn passing along a lateral wall of the frontal horn (grade 3) occurred in 1 patient (5.0%). Thus, the AGT patients experienced a significantly higher incidence of optimal catheter placement than the freehand catheterized patients (95.0% vs. 68.3%, p=0.024). Moreover, none of the AGT patients experienced any tract hemorrhages along the catheter or procedure-related complications. Conclusion : The proposed adjustable Ghajar guide technique, using angular adjustment in the coronal plane from the orthogonal trajectory at Kocher's point, facilitates accurate freehand placement of a ventricular catheter for hydrocephalic patients.

Development of Standard Work Type to Utilize Drone at Expressway Construction Sites (고속도로 건설현장에서 드론 활용을 위한 표준공종 개발)

  • Lee, Suk Bae;Jeong, Min;Auh, Su Chang;Kim, Jong Jeon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.461-468
    • /
    • 2021
  • The role of drones is increasing day by day in smart construction that manages construction sites with 3D data in every life cycles. This is because both the digital surface model (DSM) and the orthoimage obtained for the construction site through the drone are made of point cloud data. This study aims to develop standard work types for drone use in order to systematically utilize drones in expressway construction sites. For the study, two expressway construction sites in Korea were set as test beds, and construction types applicable to drones were derived and verified through a pilot project. As a result of the study, three construction work types were developed for road planning, road design and maintenance, respectively, and in road construction, twenty-one detailed construction types were developed for five construction work types. It is expected that drones can be used more systematically not only at expressway construction sites, but also at other road construction sites by utilizing the "standard work type at expressway construction site for drone use" developed in this study.