• 제목/요약/키워드: Pilot plant test

검색결과 157건 처리시간 0.027초

생물활성탄접촉조의 성능과 조작 (Performance and Operation of Biological Activated Carbon)

  • 이강춘;윤태경
    • 한국물환경학회지
    • /
    • 제22권1호
    • /
    • pp.83-90
    • /
    • 2006
  • Performance and operation of BAC in ozone-BAC advanced water treatment process were investigated using the pilot scale test plant built in D water purification plant. The performance was evaluated by the removal efficiencies of DOC, BDOC, ammonia nitrogen and THMs. The effect of EBCT on DOC removal was experimented for an effective operating condition, and the amount of attached biofilm was analyzed in various water temperatures and position of BAC. Two removal mechanisms, adsorption and biological decomposition by attached biofilm, were predominant to decrease the concentration of various contaminants. DOC was removed 40%, and the removal rate was decreased in winter time due to the lowered activity of attached biofilm. BDOC was effectively removed. THMs and ammonia nitrogen were mainly removed not in ozonation process but in BAC. Water temperature deeply influenced in removal efficiency of ammonia nitrogen. The amount of attached biofilm depended on water temperature and height of packed activated carbon column. Considering DOC removal efficiency and design EBCT of commercial BAC plant, the proper EBCT was 12.5 minutes.

공정 모사를 통한 하수처리장 내 은나노물질 제거 평가 (Assessment of Removal of Silver Nanoparticle in Sewage Treatment Plant Waste Using Process Simulation)

  • 오승윤;김영훈
    • 청정기술
    • /
    • 제20권2호
    • /
    • pp.160-165
    • /
    • 2014
  • 지난 수년간 나노기술의 혁신성과 다양한 나노소비제의 적용으로 수많은 나노물질들이 제조되었다. 아울러 나노물질과 나노소비재의 연간 생산량이 증가하고 있어서, 의도하지 않은 환경 노출이 야기되고 있다. 그러나 나노물질을 함유한 폐수는 기존 하폐수처리 시설을 이용하고 있는 실정이다. 국내는 지금까지 실제 하폐수처리장내 나노물질 제거효율을 평가한 사례가 없다. 이에 현장 노출평가에 앞서 파일럿 규모의 하수처리장치를 설계하고자, 설계인자 도출을 위한 슬러지내 나노물질 제거 모델식과 상용 공정 시뮬레이션을 이용하였다.

컴팩트 석탄 가스화기 개발을 위한 이중선회버너 운전 평가 (Performance test of double swirl burner for the development of pilot scale compact gasifier)

  • 강석환;류재홍;정석우;정우현;유상오;이도연;윤용승;이진욱;김규태;이민회
    • 에너지공학
    • /
    • 제22권2호
    • /
    • pp.96-104
    • /
    • 2013
  • 석탄가스화 기술은 청정석탄에너지 기술 중에서 아주 중요한 대안으로 인식되고 있으며, 이에 전 세계적으로 차세대 석탄가스화기라고 할 수 있는 고효율 저비용 석탄가스화기를 개발하고 있다. 본 연구에서도 이러한 목적의 달성을 위하여 저비용으로 구현이 가능한 컴팩트 석탄가스화기를 개발하고 있으며, 다수개의 공급부로 이루어진 일체형 이중선회형 버너를 개발하였다. 개발된 버너의 가스화 운전조건을 확보하기 위하여 미분탄 분배기와 함께 기존의 석탄가스화기 몸체에 설치하여 가스화 실험을 수행하였다. 인도네시아산 아역청탄인 ABK 탄을 사용하여 1.5톤/일의 파일럿 규모로 $6.4{\sim}7.2kg/cm^2$, $1170{\sim}1300^{\circ}C$ 조건에서 운전을 수행하였다. 우선 성능평가보다는 안정적인 가스화기 운전조건을 확보하는데 중점을 두었다. 그 결과, 안정적인 운전조건에서 탄소전환율은 84.0%, 냉가스 효율 52.1%를 확보할 수 있었다.

섬진강 수계에서 막여과 정수처리 공정 적용성 평가 (Application of Water Treatment with Membrane in Seomjin River)

  • 김종두;박경욱;박철휘
    • 멤브레인
    • /
    • 제23권1호
    • /
    • pp.12-23
    • /
    • 2013
  • 섬진강 수계의 복류수를 대상으로 막여과 정수처리 공정 현장 적용성 평가를 위해 여과막의 공경에 따른 막오염도 예측 및 최적 응집제 주입농도 선정을 통해 파일롯플랜트 규모의 검증실험을 실시하였다. 막공경에 따른 막오염도 평가를 위한 여과저항 평가실험 결과, $0.1{\mu}m$$0.01{\mu}m$ 여과막의 비가역적 여과저항 증가율은 각각 $0.44{\times}10^{12}/m^2$, $0.42{\times}10^{12}/m^2$로 나타났으며, Flux-test 실험결과, 적정응집제 주입농도는 Jar-Test 실험결과에 비해 낮게 나타났다. 현장 적용성 평가를 위해 6개월 동안의 파일롯플랜트 운영을 수행하였다. 응집을 실시하지 않은 막여과공정은 여과유속 $1.0{\sim}1.5m^3/m^2{\cdot}day$, 응집을 실시한 막여과 공정은 여과유속 $1.0{\sim}2.0m^3/m^2{\cdot}day$의 조건에서 운전한 결과 두 조건 모두 6개월 이상 막차압이 안정되게 유지되었다. 따라서 섬진강 수계의 복류수를 이용한 막여과 공정 운영에 있어 적정 여과유속으로 운전 시 응집제 사용 없이 안정적인 운전이 가능함을 알 수 있었다.

Development of the Pilot System for Radioactive Laundry Waste Treatment Using UV Photo-Oxidation Process and Reverse Osmosis Membrane

  • Park, Se-Moon;Park, Jong-Kil;Kim, Jong-Bin;Shin, Sang-Woon;Lee, Myung-Chan
    • Nuclear Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.506-511
    • /
    • 1999
  • The pilot system for radioactive liquid laundry waste was developed with treatment capacity, 1ton/hr and set up in the Yong Kwang unit #4. The system is composed of tank module, RO systems and a UV/$H_2O$$_2$photo-oxidation unit. The RO system consists of the BW unit (low-pressure RO for brackish water desalination) and the SW unit (high-pressure RO for seawater desalination). The BW unit possesses 4 RO membranes and it can reduce the feed water volume down to 1/10. This concentrated feed water can be reduced again up to 1/10 in its volume in the SW unit composed of 4 RO membranes. The UV/$H_2O$$_2$ photo-oxidation process unit was used for the detergent degradation. The operation of the pilot system was carried out and verified in its capability through the continuous operation and concentration operation using the actual liquid waste from the power plant. The design criteria and data for industrialization were yielded. The efficiency of the UV/$H_2O$$_2$ photo-oxidation process and the optimum operational procedure were evaluated. The decontamination factors for radioactive cobalt and cesium were measured. This on-site test showed the experimental result in the DF$\geq$300 and volume reduction factor$\geq$100.

  • PDF

부영양화 인공호소의 수질관리를 위한 초고속응집침전(URC)공정의 적용 (The Application of URC Process for Water Quality Management of An Artificial Eutrophicated Lake)

  • 윤태광;윤태일;김창균;박세진
    • 대한환경공학회지
    • /
    • 제22권11호
    • /
    • pp.2025-2036
    • /
    • 2000
  • 부영양화 호소의 수질관리를 위한 물리화학적 처리공정-초고속응집침전(URC) 공정의 적용가능성을 확인하기 위해 인하대학교내에 있는 위락용 소형호소인 인경호를 대상으로 pilot plant 규모의 실험이 수행되었다. URC 공정은 부영양화를 억제할 수 있는 주요인자인 총인을 95%이상 제거할 수 있도록 특별하게 설계되어졌다. 실험기간 중 총인과 클로로필-a를 기준으로 하는 Carlson의 호소영양상태지수는 운전 전 각각 70과 73에서 운전 후 약 55로 개선되었다. 또한 응집처리에 의해 유출수내에 존재할 수 있는 잔류 알루미늄과 추가적으로 주입되는 가중응집제와 고분지응집제에 의한 Photobacterium phosphoreum의 잠재적인 독성영향이 명가되었으며 실험결과 응집 유출수는 형광 미생물에게 어떠한 영향($EC_{50}$-15min)도 미치지 않음을 확인할 수 있었다. URC 공정의 운전 이후 인경호는 국내 호소 수질환경기준 II등급으로 투명도를 회복할 수 있었으며, 보다 큰 호소의 수질관리를 위한 URC 공정의 적용이 기대된다.

  • PDF

The pilot study on reclamation of incineration ashes of municipal waste in the demonstrative factory

  • Chang Hui-Lan;Liaw Chin-Tson;Leu Ching-Huoh
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.573-580
    • /
    • 2003
  • In Taiwan there are 21 Municipal Solid Waste Incinerators (MSWI) built to treat 80% of the MSW nationwide. Approximately 2,000 tons of incineration ashes of municipal waste contain reaction ash and fly ash (3:1 by weight)will be produced daily, and this may cause a serious waste problem. According to EPA regulations, reaction ash and fly ash produced after incineration should be properly treated. Landfill capacity barely meets the general demands. More efficient actions should be planned and taken. The study found 'reclamation' should be the optimal solution to this problem. Only limited research and previous successful experiences are available among other countries. An incinerator in Northern Taiwan is chosen for this study to make environmental bricks from the reaction ash and fly ash. From the previous tests, the results of strength test were measured. From the previous test results, the fly ash products have not reached the desired strength; hence, reaction ash is chosen for further pilot study. In the experiment, incineration ashes, cement and gravel are mixed in the ratio of 1:1:1(by weight), to ground concretization aggregate and pelletization aggregate, the concrete products made from the aggregates were of the strength of 108 $kgf/cm^2$ and 142 $kgf/cm^2$ individually. For the purpose of making nonstructural walls which met the State Building Standards. In the study, 50 tons of concrete products was yielded from aggregate and environmental bricks. Further observation and supervision are recommended to ascertain the resource recycling and reclamation. EPA has planned to build three 'Recycling Plants' in northern, middle and southern Taiwan to develop efficient techniques to produce concrete products, sub-base course, soundproofing wall, gravel, artificial fishing reefs, tiles, drainage, bricks and etc. This experiment of the demonstrative plant solves the problem of the incineration ashes and opens another opportunity to reclaim them.

  • PDF

냉연공장 폐수재이용을 위한 3단 역삼투시스템에서 각 단별 투과특성 연구 (Permeation Property of Each Stage in Three Stage Reverse Osmosis System for Cold-mill Wastewater Reuse)

  • 박영규
    • 멤브레인
    • /
    • 제9권4호
    • /
    • pp.209-214
    • /
    • 1999
  • 본 연구의 목적은 냉연공장 폐수재이용을 위해 3단 역삼투시스템 사용시 각단에서의 투과특성을 조사하는 것이다 판틀형 모듈 7개를 사용하여 회수율이 75% 가 되도록 3단 (배열 : 4+2+1) 으로 구성하여 장기간에 걸친 pilot test를 통해 막오염 진행에 따른 각 단에서의 유량 및 수질변화를 조사하였다 실험결과 각 단 모듈 1개당 평균 투과수량은 운전초기에는 1단, 2단, 3단의 순서로 많았으나 운전시간이 경과하며 막오염이 진행됨에 따라 1단은 감소하는 반면 2단은 거의 변화가 없고 3단의 투과수량은 증가하였다 즉 막오염은 주로 1단에서 발생하며 점차 2단. 3단으로 진행되는 것을 확인할수 있었다. 한편 투과수 수질은 예상한 것과 같이 1단이 가장 우수하였고 다음으로는 2단, 3단의 순서였으며 막오염에 영향을 받지않았다.

  • PDF

CFD모사 기법을 이용한 관내 혼화장치내 흐름 특성 평가 (Evaluation of Flow Characteristics within In-Line Mixer for Water Treatment using CFD Technique)

  • 박대진;박영오;박노석;김성수;왕창근
    • 상하수도학회지
    • /
    • 제22권3호
    • /
    • pp.351-358
    • /
    • 2008
  • The modified in-line mixer which was suggested in this study for small water treatment facilities was evaluated on the performance of coagulation. For the objectives of this research, computational fluid dynamics(CFD) simulation was applied for analysis of flow characteristics within the modified in-line mixer. For verifying the results of CFD simulation, wet tests for the pilot plant were conducted. The wet test was to measure the actual coagulant dispersion distribution on the overall cross-section at a distance of 5.5D from the chemical injection point. From the results of CFD simulation and wet test, it was shown that the coagulant dispersion within the modified in-line mixer was occurred more uniformly than within the existing PDM(Pump diffusion Mixer). The results have confirmed the modified in-line mixer had several advantages compared with the existing PDM in terms of dispersion efficiency.

畜産廢水處理시스템의 最適說計要因 導出 (Optimum Design of Animal Wastewater Treatment System)

  • 오인환;박정현;김범석;이상락;맹원재
    • 한국축산시설환경학회지
    • /
    • 제1권1호
    • /
    • pp.47-53
    • /
    • 1995
  • An efficient Treatment of animal wastewater is one of the hot issues for preventing the environmental pollution. It should be established the design parameter in order to purify the animal wastewater. A test is carried on in the pilot plant as a simplified activated sludge process. A vibration sieve separator is deviced to keep the pollution load constant by means of separation of solid matter. The BOD removal efficiency of the vibration sieve showed over 50%. As the test results, the BOD contents of the influent was in average of 3,000 mg/I and that of the effluent 85 mg/I. So, the BOD removal rate showed 97% in average. The SS-contents in the primary chamber was about 3,300 mg/I and that of effluent 92 mg/I. The SS removal efficiency showed 97%. The removal rate of total nitrogen and phosphore were in average of 82% respectively. Carrying out in winter season, it showed relatively good results; The design parameter approved in this test can be applied to the full-time farmers.

  • PDF