• 제목/요약/키워드: Pilot flame

검색결과 59건 처리시간 0.027초

연소실 압력변동에 따른 화염 진동현상의 관찰 (Observation of flame oscillation with changing combustor pressure)

  • 김종률;최경민;김덕줄
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2005년도 제31회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.275-280
    • /
    • 2005
  • At previous study, nitrogen oxide emission was decreased with decreasing pressure index. This tendency was explained by the flame oscillation with changing combustor pressure. In this study, the characteristics of flame oscillation with changing combustor pressure were investigated. It can be found that flame length is extended and flame width is narrowed by decreasing combustor pressure. It can be observed that pilot flame and the surrounding air converge on the inner flame in the $P^{\ast}{\geqq}1$ conditions and that surrounding air and flow pattern was widely dispersed in the $P^{\ast}<1$ conditions. In the respect of average flame length, low fluctuation was shown in the $P^{\ast}<1$ conditions. On the other hands, large fluctuation was shown in the $P^{\ast}<1$ conditions. Flame oscillation are observed from $P^{\ast}=$ 0.98 in the condition of $P^{\ast}<1$ and the amplitude of flame oscillation becomes larger when $P^{\ast}$ is lowered. These results demonstrate that low NOx phenomenon was caused by flame oscillation with changing combustor pressure.

  • PDF

관내 희박 예혼합 프로판/공기와 메탄/공기 화염의 거동에 관한 실험적 연구 (Experimental Study on the Behaviors of Lean Premixed Flame of Propane/Air and Methane/Air in a Tube)

  • 곽영태;오광철;신현동
    • 한국연소학회지
    • /
    • 제10권2호
    • /
    • pp.35-41
    • /
    • 2005
  • Behaviors of lean premixed flame of propane/air and methane/air flame anchored by a pilot flame in a tube were investigated experimentally varying the mean velocity from 10 to 140 cm/s and the equivalence ratio from 0.45 to 0.8. Behaviors of both flames are divided into five regions of stable, flash-back, tail-out, flickering and vibrating. General characteristics of each region and Le number effect are investigated. Two main instabilities, flickering and vibration, are both unstable but the instability mechanism, the frequency and the amplitude of pressure fluctuation are different. In the edge of the vibrating region, pressure fluctuation repeats generation and extinction. Repeated growth and decrease of the amplitude of pressure fluctuation are explained by Rayleigh#s index.

  • PDF

희박 예혼합 가스터빈 연소기 3 차원 전산 해석 및 화학반응기 네트워크에 의한 NOx 예측 (3D RANS Simulation and the Prediction by CRN Regarding NOx in a Lean Premixed Combustion in a Gas Turbine Combustor)

  • 이재복;정대로;허강열;진재민;박정규;이민철
    • 대한기계학회논문집B
    • /
    • 제35권12호
    • /
    • pp.1257-1264
    • /
    • 2011
  • 희박예혼합 가스터빈 연소기에 대한 3 차원 RANS 해석을 수행하였으며 PCFM(Partially Premixed Coherent Flame Model) 화염면적밀도 생성항 상수의 보정을 통하여 희박연소조건을 모사하였다. PCFM 에서 계산된 화염면적밀도에 의해 층류 예혼합 화염의 전파를 예측하고 불균일하게 분포한 기연 가스의 물성을 평형 가정에 따라 예측하였다. 복사와 대류 열전달을 모사하기 위해 냉각 조건으로서 실험과의 비교를 통해 결정된 열유속을 적용하였다. 이러한 3 차원 해석 결과를 바탕으로 파일럿 노즐과 메인 노즐에 분배되는 연료량 비에 대한 민감도 조사를 수행하였으며 CRN(Chemical Reactor Network)을 구성하여 NOx 배출량을 예측하고 측정값과 비교 분석하였다.

마이크로 가스터빈용 하이브리드/이중 선회제트 연소기 개발 (Part II: 비반응 유동에 관한 수치해석) (Development of Hybrid/Dual Swirl Jet Combustor for a MGT (Part II: Numerical Study on Isothermal Flow))

  • 문선여;황철홍;이기만
    • 한국추진공학회지
    • /
    • 제17권5호
    • /
    • pp.70-79
    • /
    • 2013
  • 마이크로 가스터빈용 하이브리드/이중 선회제트 연소기의 비반응 유동 및 혼합특성에 관한 수치해석 연구가 수행되었다. 고정된 열부하에서 pilot 버너의 위치, 선회 각 및 방향이 주요 변수로 검토되었다. 결과로서, pilot 버너의 위치, 선회 각 및 방향의 변화는 버너 출구 근처의 난류 유동장, 특히 중앙 재순환영역 및 난류강도의 큰 변화를 초래하며, 화염안정성 및 배기성능의 큰 변화를 동반하게 된다. 실험결과와의 비교를 통해, 하이브리드/이중 선회제트 연소기의 개발을 위하여 화염안정성 및 배기의 측면에서 pilot 버너의 최적 위치, 선회각$45^{\circ}$ 그리고 정방향 선회유동 조건들이 선택되었다.

다단 연소기를 이용한 LNG 화염의 NOx 발생에 관한 실험적 연구 (An Experimental Study on the NOx Formation of LNG Flame in Fuel Staged Combustor)

  • 정진도;한지웅;안국영
    • 대한기계학회논문집B
    • /
    • 제28권4호
    • /
    • pp.389-394
    • /
    • 2004
  • An experimental study on the NOx formation of LNG flame in fuel staged combustor has been studied. The design concept of multi fuel/air staged combustor is creation of two separate flame, a primary flame is a act as a pilot flame for the secondary combustion stage combustion zone, where most of fuel bums. Experiments were performed on a semi-industrial scale (thermal input 0.233 MW) in a laboratory furnace and Liquefied Natural Gas(LNG) was used as a primary and secondary fuels. This study included parametric study to identify the optimum operating conditions which are primary/secondary fuel ratio, and primary/secondary air ratio for reducing NOx emission with two types of nozzle. The test demonstrated that NOx emission can be reduced by >70% in accordance with operating conditions.

다단 연소기를 이용한 LNG 화염의 NOx 발생에 관한 실험적 연구 (An Experimental study on the NOx Formation of LNG Flame in Fuel Staged Combustor)

  • 한지웅;안국영;김한석;정진도;박경진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.161-166
    • /
    • 2001
  • An Experimental study on the NOx formation of LNG flame in fuel staged combustor has been studied. The design concept of multi fuel/air staged combustor is creation of two separate flame, a primary flame is act as a pilot flame for the secondary combustion stage combustion zone, where most of fuel burns. Experiments were performed on a semi-industrial scale (thermal input 0.233 MW) in a laboratory furnace and Liquefied Natural Gas(LNG) was used as primary and secondary fuels. The study included parametric study to identify the optimum operating conditions which are primary/secondary fuel ratio, and primary/secondary air ratio for reducing NOx emission with two types of nozzle. The test demonstrated that NOx emission can be reduced by >70% in accordance with operating conditions.

  • PDF

발전용 미분탄 보일러의 연소 상태 감시를 위한 화염 영상 처리 시스템 (Flame Image Processing System for Combustion Condition Monitoring of Pulverized Coal Firing Boilers in Thermal Power Plant)

  • 백운보;신진호
    • 제어로봇시스템학회논문지
    • /
    • 제12권11호
    • /
    • pp.1119-1123
    • /
    • 2006
  • The flame image processing and analysis system has been investigated for the optimal pulverized coal firing of thermal power plant, especially for lower nitrogen oxide generation and more safe operation. We aimed at gaining the relationship between burner flame image information and emissions of nitrogen oxide and unburned carbon in furnace utilizing the flame image processing methods, by which we quantitatively determine the condition of combustion on the individual humors. Its feasibility test was undertaken with a pilot furnace for coal firing, through which the system was observed to be effective for the monitoring of the combustion condition of pulverized coal firing boilers.

예혼합 희박연소 가스터빈 연소기의 저 NOx 특성 (The Low-NOx Characteristics of Premixed Lean-Burn Gas Turbine Combustor)

  • 배형수;안국영;박종일;안진혁;김용모
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1999년도 제19회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.201-207
    • /
    • 1999
  • The combustion characteristics for the low NOx 50 kW-class gas turbine combustor have been experimentally investigated. In order to achieve the premixing and the lean burn combustion, the geometries of the primary zone including premixed chamber were modified from conventional combustor. The centerline profiles of CO and NO concentration, and temperature were measured for the premixed combustors with or without dilution holes in the liner. The effects of the pilot fuel injection rate and air dilution on flame stabilization and pollutant (CO, NO) emission are discussed in detail.

  • PDF

관내 프로판/공기와 메탄/공기 화염의 펄럭임 현상에 대한 연구 (Study on the flickering behavior of propane/air and methane/air premixed flame confined in a tube)

  • 곽영태;이대근;오광철;신현동
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제32회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.26-31
    • /
    • 2006
  • Flickering behaviors of lean premixed flame of propane/air and methane/air flame anchored by a pilot flame in a tube were investigated. Unsteady behaviors of the flame were monitored by a high speed ICCD camera and the flickering frequency was defined as the number of flame curvatures passing a fixed spatial point in a second. Unlike previous studies in which flames are in open condition so that the flickering mechanism is an unstable interaction of hot buoyant products with the ambient air, flames in this study are surrounded by a tube which means they are not open to ambient air, so that there is no interaction between hot buoyant products and ambient air. Despite the fact, there exists flickering phenomena and the flickering frequency ranges from 10 Hz to 50 Hz which is wider compared to previous studies. We relate the flickering mechanism to flame-generated vorticity and analytic solution for locally approximated flow is used. As a result, the relationship between flickering wavelength and dimensionless vorticity is acquired and the cause of higher range of flickering frequency is explained.

  • PDF

화염감시 시스템 개발에 관한 연구 (A Study on the Flame Monitoring System Development)

  • 백운보;황이철;이승종
    • 한국정밀공학회지
    • /
    • 제21권2호
    • /
    • pp.60-66
    • /
    • 2004
  • Increased energy costs have placed demands for improved combustion efficiency, high equipment availability, low maintenance and safe operation. Simultaneously low NOx modification, installed due to stricter environmental legislations, require very careful combustion management. The flame diagnostics system has been developed specially to meet these requirements. We aimed at gaining the relationship between burner flame image and emissions such as NOx and unburned carbon in furnace by utilizing the image processing method. For the first step of development, its possibility test was undertaken with bench furnace. The test proceeded to the second step with pilot furnace, the system was observed to be effective for evaluating the combustion conditions.