• 제목/요약/키워드: Pilot Valve

검색결과 87건 처리시간 0.027초

건설기계용 유압실린더 위치 제어시스템의 성능개선에 관한 연구 (A study on performance improvement of position control system in hydraulic cylinder for heavy construction machinery)

  • 한석재;박성환;이진걸
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1450-1454
    • /
    • 1996
  • Even though digital control type high speed solenoid valve is a little inferior to analog control type servo valve and proportional control valve in performance, it is cheap and has secure performance against pollutant and simple control circuit. But high speed solenoid valve is hardly used for heavy machinery instead of servo valve or proportional control valve that is used in severe condition because the valve itself is small capacity and it shows wide dead zone during on-off control and chattering of hydraulic cylinder by chattering of pressure. It is desirable to use low-priced and strong pollutant resistant high speed solenoid valve for obtaining reliability of operation from severe working condition because it isn't necessary to acquire response characteristic of high frequency when we consider the characteristic of heavy machinery operation. In this study, PWM control algorithm for pilot pressure control of large capacity pilot operating valve will be used for precision position control of heavy machinery hydraulic cylinder. Not only cost reduction of main control valve but also high reliability of heavy machinery in severe condition can be obtained by using this pilot operating spool valve with high speed solenoid valve.

  • PDF

밸브 입구 압력 변화에 따른 연소기 산화제 개폐밸브 열림 특성 (Opening Characteristics of a Main Oxidizer Shut-off Valve at Different Valve Inlet Pressures)

  • 홍문근
    • 한국항공우주학회지
    • /
    • 제48권10호
    • /
    • pp.801-807
    • /
    • 2020
  • 밸브 입구 압력 변화에 따른 액체로켓엔진용 연소기 산화제 개폐밸브의 개방 특성에 대해 시험을 통한 연구를 수행하였다. 연소기 산화제 개폐밸브의 포핏 방식 밸브 특성에 의해 밸브 입구 압력이 상승함에 따라 밸브 개방에 필요한 구동압력은 선형적으로 증가하며, 밸브 행정 시간은 감소하게 된다. 하지만 밸브 입구 압력 상승으로 밸브 개방 구동압력 도달까지의 시간이 길어져 전체적인 밸브 개방 시간이 증가하는 것으로 나타났다. 결국 밸브 입구 압력이 증가할수록 밸브 행정 시간의 감소량은 미미해지며 밸브 개방에 필요한 구동압력에 도달하는데 필요한 시간이 밸브 개방 시간을 좌우한다는 것을 확인하였다. 따라서 밸브 구동부에 대한 설계를 통해 밸브 개방 시점의 밸브 입구 압력과 연소기로의 순간적인 산화제 공급량을 조정할 수 있다.

파이로트 구동용 압력제어밸브의 특성 해석 (Characteristics Analysis of Pilot Operated Pressure Control Valve)

  • 윤소남;최영호;함영복;김광영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.725-728
    • /
    • 2002
  • In this Paper, a mathematical model describing the dynamics of pilot operated pressure control valve was derived. A attempt to analyze the Parameters(seat diameter, cone angle, spring stiffness, control volume) which relate to the performance of the object valve was carried out. Simulation using AMESim as a simulation tool was operated, and verified the validity of our simulation by means of comparison our simulation results with an experimental results of the pilot operated pressure control valve.

  • PDF

파일럿 스풀이 주 스풀에 동심 내장된 2단 방향제어밸브의 기초적 특성 (Basic Characteristics of a Two Stage Directional Control Valve with Pilot Spool Assembled in Main Spool Coaxially)

  • 이일영;손제목
    • 동력기계공학회지
    • /
    • 제14권6호
    • /
    • pp.102-108
    • /
    • 2010
  • In this study, the authors investigate the basic characteristics of a two stage directional control valve with pilot spool assembled in main spool coaxially. The step response characteristics and effects of major design parameters' values on valve performances arc clarified through numerical simulations. In addition, the authors examined the possibility of applying the object valve for this study as a proportional control valve. Based on the numerical simulation results, new design values for the reformed design as a proportional control valve were suggested.

전자 유압식 비례 교축 제어 밸브의 특성 (Static and Dynamic Characteristics of Electro - hydraulic Proportional Throttle Control Valve)

  • 오인호;이일영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권4호
    • /
    • pp.87-99
    • /
    • 1993
  • Nowadays, the cartridge valve can be controlled proportionally in remote place by adopting proportional solenoid and it becomes widely used as control component in hydraulic systems. Especially, multi stage proportional valve is attractive because it consumes less input power though its characteristics might slightly be defected. But, the system parameter should be carefully chosen to obtain optimistic characteristics. This study concerning three stage proportional throttle control valve is purposed to examine the influences of paameters to the dynamic characteristics. The typical transient and frequency responses of proportional throttle control valve were inspected through the experiments and compared to those derived from the theoritical analyses. And it was confirmed that the analyses are appropriate. Then the influences of various system parameters to the dynamic characteristics were examined by means of simulations. For the analyses, the basic equations derived from lumped model were linearized and the linearized equations were transformed to the transfer functions between inputs and outputs. Then the transient responses and frequency responses were obtained from transfer functions. 1. It is appropriate to estimate the dynamic characteristics of valve which has relatively sophisticated structure by means of system analyses using linearized equations. 2. Though the valve has two pilot stages, fairly good characteristics can be obtained by carefully choosing system parameters. 3. Main valve very quickly follows the movement of second pilot valve when the parameters of main valve(the oil supply passage and discharge passage fpr second pilot valve) are appropriately chosen.

  • PDF

Low-Band Type 능동형 현가제어를 위한 직동식 전자비례 감압밸브의 개발 (Development of a Direct-Operated Proportional Pressure Reducing Valve for Low-Band Type Active Suspension Control)

  • 홍예선;류시복;김영식
    • 한국자동차공학회논문집
    • /
    • 제2권3호
    • /
    • pp.75-84
    • /
    • 1994
  • In general direct-operated pressure reducing valves have been gardly applied to a dynamic control system such as active suspension control because of their poor control stability. But they are more robust than pilot-operated type and do not need pilot control flow. In this paper development of a new direct-operated proportional pressure reducing valve for low-band type active suspension control is reported. By means of a special damper directly linked to the valve spool, the control stability could be effectively improved without drawback in response time. The linearity error was less than $\pm$3.5%. Applied to an experimental active suspension system the new valve showed the $-90^{\circ}$ phase delay at 4Hz with 20% sinusoidal signal input and could control the suspension system with almost same performance as that with a pilot-operated type valve.

  • PDF

유압 전자 파일럿밸브를 이용한 섬유송출기 속도제어에 관한 연구 (A Study on Speed Control of Textiles Let off Using Hydraulic Solenoid Pilot Valve)

  • 이재구;김도태;김성동
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.225-230
    • /
    • 2002
  • Machine of textiles let off is equipment supplying constantly fabrics. Nowdays, as it is replaced band - brake type with hydraulic motor driven type, we looked into characteristic of hydraulic solenoid pilot direction valve(SPDV) for controlling acceleration performance of hydraulic motor. This study deals with controlling the initial speed of textiles let off machine. Finally, to control the initial speed of hydraulic motor, we controlled the adjustment screw of SPDV by a hand. Test which was carried out in the laboratory shows that initial speed of textiles let off could be improved by controlling adjustment screw of SPDV. Also, the results of experiment work were compared with dynamic characteristic of other on/off solenoid direction valve(SDV).

  • PDF

방향제어 조직밸브의 동특성에 관한 연구 (A Study on Dynamic Characteristics of Directional Control Logic Valve)

  • 이일영;오세경
    • 수산해양기술연구
    • /
    • 제24권4호
    • /
    • pp.172-179
    • /
    • 1988
  • A cartridge type hydraulic logic valve consists of simple two port valve whose poppet is closed or opened by means of pressure signal of a pilot line. Accordingly, the logic valve can be used not only for direction, flow and pressure control purpose but also for versatile function valve which enables all above mentioned functions. In addition, the valve has little internal leakage and pressure loss, superior response characteristics and easiness in making small block type valve. The above mentioned good performances being recognized recently, the logic valve has been used widely in the large scale hydraulic system such as a hydraulic press system, for the performance requirements of high speed operation and precise control characteristics. However, there are scarce reports until now, except for a few ones from Aachen Institute of Technology in West Germany, so it is necessary to be studied on development and investigation for practical application. This paper showed that the static and dynamic characteristics of a logic valve when the logic valve is used for directional control, to investigate the relations between the valve operating characteristics and the valve design conditions. From the above mentioned procedure, it was ascertained that the valve operation characteristics obtained by numerical analysis showed good agreements with experimental results. The representative results obtained are as follows; 1. During the valve is closing, the poppet velocity is almost constant in the logic valve. 2. The pilot pressure P sub(3) and the resistance R in the pilot line have much influences on the valve operation time. 3. Spring strength have not such a severe influence on the valve operating time. 4. The operation characteristics of the logic valve can be estimated with good accuracy comparatively by numerical analysis with the equations describing poppet motion.

  • PDF